Ilogo ye-MacroarraydxIlogo ye-Macroarraydx 1I-QUALITYXPLORER
UMYALELO WOKUSEBENZISA

UKUSETSHENZISWA OKUHLOSIWE

I-QualityXplorer iyisesekeli sokulawula inqubo yokuhlola ye-ALEX² Allergy Xplorer.
Idivayisi yezokwelapha iqukethe ingxubevange yamasosha omzimba asabela nezifo ezichaziwe ku-ALEX² Allergy Xplorer futhi isetshenziswa izisebenzi zaselabhorethri eziqeqeshiwe nochwepheshe bezokwelapha elabhorethri yezokwelapha.

DESCRIPTION

I-QualityXplorer izosetshenziswa njengokulawula ikhwalithi yokuqapha imikhawulo ecacisiwe (amashadi okulawula inqubo) ngokuhambisana nenqubo yokuhlola ye-ALEX².
Ulwazi olubalulekile lomsebenzisi!
Ukuze usebenzise kahle i-QualityXplorer, kuyadingeka ukuthi umsebenzisi afunde ngokucophelela futhi alandele le miyalo ukuze ayisebenzise. Umkhiqizi akanaso isikweletu nganoma yikuphi ukusetshenziswa kwalo mkhiqizo okungachazwanga kule dokhumenti noma ukuguqulwa komsebenzisi womkhiqizo.

UKUTHUMELA KANYE NESIGCINI

Ukuthunyelwa kwe-QualityXplorer kwenzeka ezimweni zokushisa ezizungezile.
Noma kunjalo, i-QualityXplorer kufanele igcinwe, ngemva kokuphothwa phansi koketshezi, isendaweni eqondile lapho ilethwa ku-2-8°C. Igcinwe kahle ingasetshenziswa kuze kube usuku olukhonjiwe lokuphelelwa yisikhathi.

Isithonjana sesixwayiso Ama-QualityXplorers enzelwe kuphela ukunqunywa okukodwa ngebhodlela ngayinye. Ngaphambi kokuvula, phenya kancane uketshezi olusezitsheni. Ngemuva kokuvula izitsha, kufanele zisetshenziselwe ukuhlaziya ngokushesha.
Isithonjana sesixwayiso Izingxenye zegazi lomuntu ezisetshenziswa ekwenziweni kwe-QualityXplorer zihloliwe futhi zatholakala zingenayo i-HBsAG, i-HCV kanye namasosha omzimba egciwane le-HI.

UKULAHLWA KWEMFUCUZA

Lahla i-QualityXplorer esetshenzisiweample nemfucuza yamakhemikhali aselabhorethri. Landela yonke imithetho kazwelonke, yesifunda, neyendawo mayelana nokuchithwa.

UHLU LWEZIMFANEKISO

I-Macroarraydx REF 31-0800-02 QualityXplorer Macro Array Diagnostics - isithonjana Inombolo yekhathalogi
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 1 Iqukethe okwanele izivivinyo
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 3 Ibonisa okokusebenza kokulawula okuhloselwe ukuqinisekisa imiphumela ebangeni eliphozithivu elilindelekile
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 4 Ungasebenzisi uma ukupakishwa konakele
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 5 Ikhodi yeqoqo
funda lo mhlahlandlela Bheka imiyalelo yokusetshenziswa
I-Espenstrasse Umkhiqizi
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 6 Ungaphinde usebenzise
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 7 Idethi yokusebenzisa
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 9 Umkhawulo wezinga lokushisa
I-Macroarraydx REF 31-0800-02 I-QualityXplorer Macro Array Diagnostics - isithonjana 10 Okokusetshenziswa Kocwaningo Kuphela
Isithonjana sesixwayiso Isexwayiso

AMA-REAGENTS KANYE NEMATERIAL

I-QualityXplorer ipakishwe ngokwehlukana. Idethi yokuphelelwa yisikhathi nezinga lokushisa lokulondoloza kubonisiwe kulebula. Ama-reagents akufanele asetshenziswe ngemuva kosuku lwawo lokuphelelwa yisikhathi.

Isithonjana sesixwayiso Ukusetshenziswa kwe-QualityXplorer akuncikile ku-batch ngakho-ke kungasetshenziswa ngaphandle kwenqwaba ye-ALEX² Kit esetshenzisiwe.
Into Ubuningi Izakhiwo
I-QualityXplorer
(REF 31-0800-02)
Izitsha eziyi-8 kuye ku-200 μl
I-Sodium Azide 0,05%
Ilungele ukusetshenziswa. Gcina ku-2-8°C kuze kube yidethi yokuphelelwa yisikhathi.

Ukwakheka kwe-QualityXplorer kanye nezikhawu ezihambisanayo zokwamukela amasosha omzimba alondolozwe ku-RAPTOR SERVER Analysis Software endaweni ngayinye ye-QualityXplorer. Ngokusebenzisa imojula ye-QC ku-RAPTOR SERVER Analysis Software, imiphumela yezilinganiso ze-QualityXplorer ingaboniswa ngendlela yethebula noma yesithombe.
Ngemva kwenani eliphansi lezilinganiso (isb. 20 izilinganiso), izikhawu eziqondene nensimbi ethile (ukuchezuka okujwayelekile okungu-2 no-3) kungaboniswa ngemojula ye-QC Ku-RAPTOR SERVER Analysis Software. Ngale ndlela, izikhawu eziqondene nelabhorethri ze-allergen ngayinye zinganqunywa ngokunembe kakhudlwana.

IZIXWAYISO NEZIQINISEKISO

  • Kunconywa ukuthi ugqoke isivikelo sezandla neso kanye namajazi elebhu futhi ulandele imikhuba emihle yaselabhorethri (GLP) lapho ulungiselela futhi uphatha ama-reagents kanye s.ampLes.
  • Ngokuhambisana nokusebenza okuhle kwelabhorethri, zonke izinto eziwumthombo womuntu kufanele zibhekwe njengezinamandla okuthelelanayo futhi zisingathwe ngezinyathelo zokuphepha ezifanayo nalezo zesiguli.ampLes. Izinto zokuqala zilungiswa ngokwengxenye emithonjeni yegazi lomuntu. I
    umkhiqizo wahlolelwa ukuthi awusebenzi ku-Hepatitis B Surface Antigen (HBsAg), amasosha omzimba ku-Hepatitis C (HCV) kanye namasosha omzimba e-HIV-1 ne-HIV-2.
  • Ama-reagents asetshenziselwa ukusetshenziswa kwe-in vitro kuphela futhi akufanele asetshenziselwe ukusetshenziswa kwangaphakathi noma kwangaphandle kubantu noma ezilwaneni.
  • Lapho ukulethwa, iziqukathi kufanele zibhekwe ukuthi azikho yini umonakalo. Uma noma iyiphi ingxenye yonakele (isb., isitsha sebhafa), sicela uthinte i-MADx (support@macroarraydx.com) noma umsabalalisi wangakini. Ungasebenzisi izingxenye zekhithi ezilimele, lokhu kungase kuthinte ukusebenza kwekhithi.
  • Ungasebenzisi izingxenye zekhithi eziphelelwe yisikhathi

IWARANTI

Idatha yokusebenza ethulwe lapha itholwe kusetshenziswa inqubo echazwe kule Miyalelo Yokusetshenziswa. Noma iluphi ushintsho noma ukuguqulwa enqubweni kungase kuthinte imiphumela futhi i-MacroArray Diagnostics iyazilahla zonke iziqinisekiso eziveziwe (okuhlanganisa newaranti eshiwo yokuthengiseka kanye nokufaneleka ukuze kusetshenziswe) kumcimbi onjalo. Ngenxa yalokho, i-MacroArray Diagnostics kanye nabasabalalisi bayo basendaweni ngeke babophezeleke ngomonakalo ongaqondile noma owumphumela kumcimbi onjalo.

© Copyright by MacroArray Diagnostics
I-MacroArray Diagnostics (MADx)
I-Lemböckgasse 59/Top 4
1230 Vienna, Austria
+43 (0)1 865 2573
www.macroarraydx.com
Inombolo yenguqulo: 31-IFU-02-EN-03
Ikhishwe: 01-2023
I-MacroArray Diagnostics
I-Lemböckgasse 59/Top 4
1230 Vienna
macroarraydx.com 
I-CRN 448974 g
www.macroarraydx.com