Autonics logo.

Remote I/O Boxes (PROFINET)
ADIO-PN
PRODUCT MANUAL Autonics ADIO-PN Remote Input-Output Boxes -

For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.

Features

  • The upper level communication protocol: PROFINET
  • The lower level communication protocol:10-1_41k ver. 1.1 (port class: Class A)
  • Housing m aterial: Zinc Die casting
  • Protection rating: IP67
  • The daisy chain allows tile power supply usingthe connection technology in a standardized 7/8” connector
  • The maximum output current of power supply: 2 A per port
  • I/O port settings and status monitoring (cable short/ disconnection, connection status, etc.)
  • Supports digital input filter

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • warning 2 symbol indicates caution due to special circumstances in which hazards may occur.
    warning 2 Warning Failure to follow instructions may result in serious injury or death.
  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss.(e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in personal injury, economic loss or fire.
  2. Do not use high humidity, unitcl? te in thetstlplace gt, radiant heat, flammable/explosive/corrosive ‘ay( ‘lays may be present. Failure to follow this instruction may result in explosion or fire.
  3. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in fire.
  4. Check ‘Connections’ before wiring. Failure to follow this instruction may result in fire.
  5. Do not disassemble or modify the unit Failure to follow this instruction may result in fire.
  6. Do not touch the product during operation or for a certain period of time after stopping.
    Failure to follow this instruction may result in bum.

warning 2 Caution Failure to follow instructions may result in injury or product damage.

  1. Use the unit within the rated specifications. Failure to follow this instruction may result in fi rear shortening the life cycle of the product.
  2. Use a dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in fire.
  3. Keep the product away from metal chip, dust, and wire residue which flow into the unit. Failure to follow this instruction may result in fireor product damage.
  4. Connect the cable correctly and prevent poor contact Failure to follow this instruction may result in fi re or product damage.
  5. Do not connect or cut off the wire of the cable while operating the unit Failure to follow this instruction may result in fire or product damage.

Cautions during Use

  • Follow instructions in ‘Cautions during Use: Otherwise, it may cause unexpected accidents.
  • The LA power (actuator power) and US power (sensor power) should be insulated by the individually isolated power device.
  • Power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  • Use the rated standard cables and connectors. Do not apply excessive pogger when connecting or disconnecting the connectors of the product.
  • Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter orvaristor at power line and shielded wire at input signal fine. For stable operation, use shield wire and ferrite core, when wiring communication wire, power wire, or signal wire.
  • Do not use near the equipment which generates strong magnetic force or high frequency noise.
  • Do not connect, or remove this unit while connected to a power source.
  • This unit may be used in the following environments.
    – Indoors (in the environment condition fated in ‘Specifications’)
    -Altitude max. 2,000m
  • Pollution degree 2
    – Installation category II

Configuration of ADIO-PN
The figure below shows the PROFINET network and the devices that compose it.
For proper use of the product, refer to the manuals and be sure to follow the safety considerations in the manuals.
Download the manuals from the Autonics website.

Autonics ADIO-PN Remote Input-Output Boxes - Autonics

Autonics ADIO-PN Remote Input-Output Boxes - tabile

01) The project planning software of the upper level communication system may be different depending on the user’s environment.
For more information, refer to the manufacturer’s manual.

■ The supported parameters

Operation mode Safe State 01) Validation Data Storage Input Filter 01) Vendor ID Device ID Cycle Time
Digital Input
Digital Output
10-Link Input
10-Link Output
10-Link Input/Output

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.

Autonics ADIO-PN Remote Input-Output Boxes - Autonics1

❶ I/O specification
N: NPN
P: PNP

Product Components

  • Product (+ Protective cover for the rotary switches)
  • Name plates × 20
  • M4×10 screw with washer × 1
  • Instruction manual × 1
  • Waterproof cover × 4

Sold Separately

  • Name plates
  • Waterproof cover

Software
Download the installation file and the manuals from the Autonics website.

  • atIOLink
    atIOLink with purposes for setting, diagnosis, initialization and maintenance of IO-Link device via IODD file is provided as the dedicated Port and Device  onfiguration Tool (PDCT).

Connections

■ Ethernet port

M12 (Socket-Female), D-coded Pin Function Description
Autonics ADIO-PN Remote Input-Output Boxes - fig 1 1 TX + Transmit Data +
2 RX + Receive Data +
3 TX – Transmit Data –
4 RX – Receive Data –

■ Power supply port

OUT (7/8″, Socket- Female) IN (7/8″, Plug-Male) Pin Function Description
Autonics ADIO-PN Remote Input-Output Boxes - fig 2 Autonics ADIO-PN Remote Input-Output Boxes - fig 3 1, 2 0 V Sensor and actuator supply
3 F.G. Frame ground
4 +24 VDC Sensor supply
5 +24 VDC Actuator supply

■ PDCT port

i M12 (Socket-Female), A-coded Pin Function
Autonics ADIO-PN Remote Input-Output Boxes - fig 4 1 Not Connected (N.C.)
2 Data-
3 0 V
4 Not Connected (N.C.)
5 Data +

■ I/O port

M12 (Socket-Female), A-coded Pin Function
Autonics ADIO-PN Remote Input-Output Boxes - fig 14 1 +24 VDC
2 I/Q: Digital Input
3 0 V
4 C/Q: 10-Link, Digital Input/Output
5 Not Connected (N.C.)

Dimensions

  • Unit: mm, For the detailed dimensions of the product, follow the Autonics website.

Autonics ADIO-PN Remote Input-Output Boxes - fig 6

Unit Descriptions

Autonics ADIO-PN Remote Input-Output Boxes - Autonics6

01. Grounding hole
02. Mounting hole
03. Insertion part for the name plate
04. Ethernet port
05. Power supply port
06. PDCT port
07. I/O port
08. Rotary switches
09. Status indicator
10. I/O port indicator

Installation

■ Mounting

  1. Prepare a flat or metal panel in the enclosure.
  2. Drill a hole to mount and ground the product on the surface.
  3. Turn off all power.
  4. Fix the product using M4 screws in the mounting holes.
    Tightening torque: 1.5 N m

Autonics ADIO-PN Remote Input-Output Boxes - Autonics7

■ Grounding

warning 2 Be sure to use a cable with low impedance and as short as possible for connecting the housing to the product.

  1. Connect the grounding strap and M4×10 screw with washer.
  2. Fix the screw in the grounding hole.
    Tightening torque: 1.2 N m

Autonics ADIO-PN Remote Input-Output Boxes - fig 7

Device Name Settings
To connect to the PROFINET network, configure the PROFINET interface. The PROFINET device name can be configured using the following methods.

  • Rotary switches

warning 2 Be sure to place the seal of the protective cover firmly on the rotary switches after completing the settings.
The protection rating is not guaranteed when the protective cover is open.

Autonics ADIO-PN Remote Input-Output Boxes - fig 8

  1. Rotate the rotary switches to set the device name. The green LED of the US indicator flashes.
    Setting mode Rotary switches Description Value
    PROFINET Device Name 0 This device name is stored in the ADIO-PN’s EEPROM.
    Applying the device name configured on the PROFINET Master or DCP tools.
    PROFINET device name
    001 to 999 Establish the communication connection after setting the ADIO-PN’s device name. The value of rotary switches is displayed at the last of the device name. ADIO-PN-MA08A-ILM-
  2. Turn on the ADIO-PN again.
  3. Check that green LED of the US indicator is ON.
  4. The device name has been changed.
  5. Put the protective cover on the rotary switches.

■ atIOLink
The PROFINET device name configured by the atIOLink software is stored in the ADIO-PN’s EEPROM. For more information, refer to the atIOLink User Manual.

Port Connections

■ Port specifications

  • Be sure to check the port specifications below before connecting the device. Prepare a cable that complies with the protection rating IP67.
Ethernet port I/O port PDCT port Power supply port
Type M12 (Socket-Female), 4-pin, D-coded M12 (Socket-Female), 5-pin, A-coded M12 (Socket-Female), 5-pin, A-coded Input: 7/8″ (Plug-Male), 5-pin Output: 7/8″ (Socket-Female), 5-pin
Push-Pull YES YES YES N.A
Number of ports 2 8 1 2
Tightening torque 0.6 N m 0.6 N m 0.6 N m 1.5 N m
Supported function Daisy chain USB serial communication Daisy chain
  • The example of communication cable for the PDCT port
Connector 1 Connector 2 Wiring
Autonics ADIO-PN Remote Input-Output Boxes - fig 9M12 (Plug-Male), 5-pin Autonics ADIO-PN Remote Input-Output Boxes - fig 10USB Type A (Plug-Male) Autonics ADIO-PN Remote Input-Output Boxes - tabile 2
  1. Connect to the PROFINETAutonics ADIO-PN Remote Input-Output Boxes - fig 1101. Connect the M12 connector to the Ethernet port. See the connections below.Autonics ADIO-PN Remote Input-Output Boxes - fig 12
    1 TX + Transmit Data +
    2 RX + Receive Data +
    3 TX – Transmit Data –
    4 RX – Receive Data –

    02. Connect the connector to the PROFINET network.
    • Network device: PLC or PROFINET device supporting PROFINET protocol
    03. Put the waterproof cover on the unused port.

  2. Connect the IO-Link devices
    warning 2 The maximum output current is 2 A at each I/O port. Configure the device so that the total current of the I/O ports does not exceed 9 A.
    warning 2 Check the wiring information in the manual of the IO-Link device to be connected.Autonics ADIO-PN Remote Input-Output Boxes - fig 1301. Connect the M12 connector to the I/O port. See the connections below.Autonics ADIO-PN Remote Input-Output Boxes - fig 16
    1 +24 VDC
    2 I/Q: Digital Input
    3 0 V
    4 C/Q: 10-Link, Digital Input/Output
    5 Not Connected (N.C.)

    02. Put the waterproof cover on the unused port.

  3. Connect with the atIOLink
    warning 2 Do not use the PDCT port and the Ethernet port at the same time.Autonics ADIO-PN Remote Input-Output Boxes - fig 1501. Connect the M12 connector to the PDCT port. See the connections below.
    Autonics ADIO-PN Remote Input-Output Boxes - fig 5
    1 Not Connected (N.C.)
    2 Data –
    3 0 V
    4 Not Connected (N.C.)
    5 Data +

    02. Connect the connector to the network device.
    • Network device: PC/laptop that atIOLink software is installed
    03. Put the waterproof cover on the unused port.

  4. Connect the power supply to ADIO
    warning 2 Be sure not to exceed 9 A of the maximum supplying current to the sensor (US).Autonics ADIO-PN Remote Input-Output Boxes - fig 1701. Turn off all power.
    02. Connect the 7/8″ connector to the power supply port. See the connections below.

Autonics ADIO-PN Remote Input-Output Boxes - fig 18

1, 2 0 V Sensor and actuator supply
3 F.G. Frame ground
4 +24 VDC Sensor supply
5 +24 VDC Actuator supply

Indicators

■ Status indicator

Autonics ADIO-PN Remote Input-Output Boxes - fig 19

  1. The power supply of sensor
    Indicator LED color Status Description
    US  

    Green

    ON Applied voltage: normal
    Flashing (1 Hz) The settings of the rotary switches is changing.
    Red Flashing (1 Hz) Applied voltage: low (< 18 VDC)
  2. The power supply of actuator
    Indicator LED color Status Description
    UA Green ON Applied voltage: normal
    Red Flashing (1 Hz) Applied voltage: low (< 18 VDC), Error in the rotary switches
    ON Applied voltage: none (< 10 VDC)
  3. Product initialization
    Indicator LED color Status Description
    US, UA Red ON ADIO initialization failure
  4. System failure
    Indicator LED color Status Description
    SF Red OFF No error
    ON Watchdog timeout, system error
    Flashing DCP signal service is initiated via the bus.
  5. Bus failure
    Indicator LED color Status Description
    BF Red OFF No error
    ON Low speed of physical link or no physical link
    Flashing No data transmission or configuration settings
  6. Ethernet connection
    Indicator LED color Status Description
    L/A1 L/A2  

    Green

    OFF No Ethernet connection
    ON The Ethernet connection is established.
    Yellow Flashing Data transmission
  7. Transmission rate of the Ethernet
    Indicator LED color Status Description
    100 Green ON Transmission rate: 100 Mbps

■ I/O port indicator

Autonics ADIO-PN Remote Input-Output Boxes - fig 20

  1. Pin 4 (C/Q)
    Indicator LED color Status Description
    0  

    Yellow

    OFF DI/DO: pin 4 OFF
    ON DI/DO: pin 4 ON
     

    Green

    ON Port configuration: IO-Link
    Flashing (1 Hz) Port configuration: IO-Link, No IO-Link device found
    Red Flashing (2 Hz) IO-Link configuration error
    •  Validation failed, Invalid data length, Data Storage error
    ON •  NPN: Short circuit occurred on the output of pin 4 and pin 1
    •  PNP: Short circuit occurred on the output of pin 4 and pin 3
  2. Pin 2 (I/Q)
    Indicator LED color Status Description
    1 Yellow OFF DI: pin 2 OFF
    ON DI: pin 2 ON
  3. The power supply of the I/O port
    Indicator LED color Status Description
    0,1 Red Flashing (1 Hz) Short circuit occurred in the I/O supply power (pin 1, 3)

Specifications

■ Electrical/Mechanical specifications

Supply voltage 18 – 30 VDC
Rated voltage 24 VDC
Current consumption 2.4 W ( ≤ 216 W)
Supplying current per port ≤ 2 A/Port
Sensor current (US) ≤ 9 A
Dimensions W 66 × H 215 × D 38 mm
Material Zinc Die casting
Ethernet port M12 (Socket-Female), 4-pin, D-coded, Push-Pull Number of ports: 2 (IN/OUT)
Supported function: daisy chain
Power supply port Input: 7/8” (Plug-Male), 5-pin Output: 7/8” (Socket-Female), 5-pin Number of ports: 2 (IN/OUT) Supported function: daisy chain
PDCT port M12 (Socket-Female), 5-pin, A-coded, Push-Pull Number of ports: 1
Connection method: USB serial communication
I/O port M12 (Socket-Female), 5-pin, A-coded, Push-Pull Number of ports: 8
Mounting method Mounting hole: fixed with M4 screw
Grounding method Grounding hole: fixed with M4 screw
Unit weight (packaged) ≈ 700 g (≈ 900 g)

■ Mode specifications

Mode Digital Input
Number of channels 16-CH (I/Q: 8-CH, C/Q:8-CH)
I/O common NPN / PNP
Input current 5 mA
ON voltage/current Voltage: ≥ 15 VDC Current: ≥ 5 mA
OFF voltage ≤ 5 VDC

■ Mode specifications

Mode Digital Output
Number of channels 8-CH (C/Q)
I/O common NPN / PNP
Power supply 24 VDC (18 – 30 VDC ), Max. 300 mA
Leakage current ≤ 0.1 mA
Residual voltage ≤ 1.5 VDC
Short circuit protection YES

■ Mode specifications

Mode IO-Link
Input current 2 mA
 

ON voltage/current

Voltage: ≥ 15 VDC Current: ≥ 2 mA
OFF voltage ≤ 5 VDC

■ Environmental conditions

Ambient temperature 01) -5 to 70 °C, Storage: -25 to 70 °C (no freezing or condensation)
Ambient humidity 35 to 75%RH (no freezing or condensation)
Protection rating IP67 (IEC standard)

■ Approvals

Approval Autonics ADIO-PN Remote Input-Output Boxes - icon0
Association approval Autonics ADIO-PN Remote Input-Output Boxes - icon 01

Communication Interface

Ethernet

Ethernet standard 100BASE-TX
Cable spec. STP (Shielded Twisted Pair) Ethernet cable over Cat 5
Transmission rate 100 Mbps
Cable length ≤ 100 m
Protocol PROFINET
Address settings Rotary switches, DCP, atIOLink
GSDML file Download the GSDML file at the Autonics website.

IO-Link

Version 1.1
Transmission rate COM1 : 4.8 kbps / COM2 : 38.4 kbps / COM3 : 230.4 kbps
Port class Class A
Standard IO-Link Interface and System Specification Version 1.1.2 IO-Link Test Specification Version 1.1.2

18, Bansong-ro 5l3Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com I +82-2-2048-1577 I sales@autonics.com

Autonics ADIO-PN Remote Input-Output Boxes - icon

Documents / Resources

Autonics ADIO-PN Remote Input-Output Boxes [pdf] Owner's Manual
ADIO-PN Remote Input-Output Boxes, ADIO-PN, Remote Input-Output Boxes, Input-Output Boxes, Output Boxes, Boxes

References

Leave a comment

Your email address will not be published. Required fields are marked *