LINORTEK - logoFargo G2 and Koda User Manual
www.linortek.comLINORTEK Fargo G2 TCP IP Web Based Relay Controller-For Fargo G2, Koda
TCP/IP Web Baseret relæcontroller
Rev C 04/2022

Fargo G2 TCP/IP Web Baseret relæcontroller

Thank you for purchasing a Linortek Fargo G2 or Koda TCP/IP Controller. There are many devices that can be controlled by the FARGO/KODA Web Relay Controller. FARGO/KODA Web Controller can be used in such applications as (but not limited to): Lights, security, sprinkler systems, access control, industrial equipment, building automation, HVAC, and many more. Please refer to the Board Reference Layouts on page 29 for input and output specifications on your controller to verify they are suitable to your needs.

Denne manual dækker:

  • FARGO R8 G2
  • FARGO R4DI G2
  • FARGO R4ADI G2
  • KODA 100
  • KODA200

These will be referred to as SERVER hereafter. When there are differences or additional features they will be noted in the text.
For instruktionsvideoer, ofte stillede spørgsmål og kontaktoplysninger til vores tekniske supportteam, besøg venligst: https://www.linortek.com/technical-support

LINORTEK ET ÅRS BEGRÆNSET GARANTI

Consumer law: For consumers who are covered by consumer protection laws or regulations in their country of residence (“Consumer Law”), the benefits provided in this Linortek One-Year Limited Warranty (“Linortek Limited Warranty”) are in addition to and  not instead of the rights provided by Consumer Law and it does not exclude, limit or suspend your rights arising from Consumer Law. You should consult the proper authorities in your country of residence for further information about these rights
Linorteks garantiforpligtelser for dette hardwareprodukt ("Produkt") er begrænset til vilkårene angivet nedenfor:
Linor Technology, Inc. (“Linortek”) warrants this product against defects in materials and workmanship for a period of ONE (1) YEAR from the date of retail purchase by the original end-user purchaser (“Warranty Period”) when used in accordance with the  operating instructions. A copy of a retail receipt is required as proof of purchase. If a hardware defect arises and a valid claim is received within the Warranty Period, at its option and to the extent permitted by law, Linortek will either (1) repair the hardware defect at no charge, using new or refurbished replacement parts, (2) exchange the product with a product that is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product, or (3) refund the purchase price of the product. When a refund is given, the product for which the refund is provided must be returned to Linortek and becomes Linortek’s property.
Ovenstående garanti er underlagt Købers (i) hurtige skriftlige krav og (ii) rettidig levering til Linortek af en mulighed for at inspicere og teste det produkt, der hævdes at være defekt. En sådan inspektion kan foregå på Købers område, og/eller Linortek kan anmode om returnering af Produktet på Købers regning. Linortek er dog ikke ansvarlig for emballerings-, inspektions- eller arbejdsomkostninger i forbindelse med returnering af produktet. Intet produkt accepteres til garantiservice, der ikke er ledsaget af et returvareautorisationsnummer (RMA#) udstedt af Linortek.
EXKLUSIONER OG BEGRÆNSNINGER
Denne begrænsede garanti udelukker skader som følge af misbrug, misbrug, forsømmelse, brand eller andre ydre årsager, ulykker, modifikationer, reparationer eller andre årsager, der ikke er defekter i materialer og udførelse. Software distribueret af Linortek med eller uden Linortek-varenavnet inklusive, men ikke begrænset til systemsoftware ("Software") er ikke dækket af denne begrænsede garanti. Din brug og rettigheder forbundet med softwaren er underlagt Linortek slutbrugerlicensaftale, som du kan finde her: https://www.linortek.com/end-user-licenseagreement/. Linortek er ikke ansvarlig for skader, der opstår som følge af manglende overholdelse af instruktioner vedrørende produktets brug. For at sikre overensstemmelse med driftsbegrænsninger bør køber henvise til instruktionsmanualen [leveret med produktet]. Batterier er ikke inkluderet i garantien.
I DET MAKSIMALT TILLADTE OMFANG, ER DENNE BEGRÆNSEDE GARANTI OG DE RETSMIDLER, DER ER ANGIVET OVENFOR, EKSKLUSIVE OG I STEDET FOR ALLE ANDRE GARANTIER, RETSMIDLER OG BETINGELSER, OG LINORTEK ER SPECIFIKKE FRASKRIVELSER, DER ER IKKE ELLER STATUS. , GARANTIER FOR SALGBARHED, EGNETHED TIL ET BESTEMT FORMÅL, IKKE-KRÆNKELSE. FORSÅDET SÅDANNE GARANTIER IKKE KAN FRASKRIVES, SKAL ALLE SÅDANNE GARANTIER, I DET OMFANG LOVEN TILLADER, VÆRE BEGRÆNSET I VARIGHED TIL VARIGHEDEN AF DEN LINORTEK BEGRÆNSEDE GARANTI, OG RETTERINGEN SKAL BLIVER BEGRÆNSET, SOM ER BEGRÆNSET VED GENBEGRÆNSET. EFTER DET ENESTE SKØN. NOGLE STATER (LANDE OG PROVINSER) TILLADER IKKE BEGRÆNSNINGER I HVOR LÆNGE EN UNDERFORSTÅET GARANTI ELLER BETINGELSE KAN VARE, SÅ BEGRÆNSNINGERNE BESKRIVET OVENFOR GÆLDER MULIGVIS IKKE FOR DIG. DENNE GARANTI GIVER DIG SPECIFIKKE JURIDISKE RETTIGHEDER, OG DU KAN OGSÅ HAVE ANDRE RETTIGHEDER, DER VARIERER FRA STAT TIL STAT (ELLER EFTER LAND ELLER PROVINS). DENNE BEGRÆNSEDE GARANTI ER STYRET AF OG FORSTÅET UNDER LOVEN I USA.
Ansvarsfraskrivelser

  1. Læs instruktionerne – Læs alle sikkerheds- og betjeningsvejledningerne, før du bruger produktet.
  2. Gem instruktionerne – Gem sikkerheds- og betjeningsvejledningen til fremtidig reference.
  3. Vær opmærksom på advarsler – Overhold alle advarsler på produktet og i betjeningsvejledningen.
  4. Følg instruktionerne – Følg alle betjenings- og brugsanvisninger.
  5. Rengøring – Tag stikket ud af stikkontakten før rengøring. Brug ikke flydende rengøringsmidler eller aerosolrens. Brug annonceamp klud kun til rengøring af kabinettet.
  6. Vedhæftede filer – Brug ikke tilbehør, medmindre de specifikt er anbefalet af Linortek. Brug af inkompatible eller på anden måde uegnede vedhæftede filer kan være farligt.
  7. Tilbehør – Anbring ikke dette produkt på et ustabilt stativ, stativ, beslag eller beslag. Produktet kan falde ned og forårsage alvorlig personskade og alvorlig skade på produktet. Brug kun med et stativ, et stativ, et beslag eller et beslag, der anbefales af producenten eller sælges sammen med produktet. Følg producentens anvisninger ved montering af produktet, og brug kun monteringstilbehør anbefalet af producenten. Vær forsigtig, når du bruger en kombination af apparat og vogn. Hurtige stop, overdreven kraft og ujævne overflader kan få apparatet og vognen til at vælte.
  8.  Ventilation – Eventuelle åbninger i kabinettet er tilvejebragt for ventilation og for at sikre pålidelig drift af produktet og for at beskytte det mod overophedning. Bloker eller tildæk ikke disse åbninger. Anbring ikke dette produkt i en indbygget installation, medmindre der er sørget for korrekt ventilation, eller Linorteks instruktioner er blevet overholdt.
  9. Strømkilder – Betjen kun dette produkt fra den type strømkilde, der er angivet i brugsanvisningen eller på produktetiketten.
    Hvis du ikke er sikker på, hvilken type strømforsyning du planlægger at bruge, skal du kontakte din apparatforhandler eller det lokale elselskab – forudsat at brug af en anden type strømkilde end angivet i instruktionsmanualen eller mærkatet vil ugyldiggøre enhver garanti. For produkter beregnet til at drive fra batteristrøm eller andre kilder henvises til betjeningsvejledningen [inkluderet med produktet].
  10. Jordforbindelse eller polarisering – Dette produkt kan være udstyret med et polariseret vekselstrømsstik (et stik med det ene blad bredere end det andet). Dette stik passer kun i stikkontakten på én måde. Dette er en sikkerhedsfunktion. Hvis du ikke er i stand til at sætte stikket helt ind i stikkontakten, så prøv at vende stikket om. Hvis stikket stadig ikke passer, er det fordi din stikkontakt er inkompatibel med stikket. Kontakt din elektriker for at udskifte din stikkontakt med en, der er kompatibel. Tving ikke stikket til at passe ind i en inkompatibel stikkontakt eller på anden måde forsøge at omgå stikkets sikkerhedsformål. Alternativt kan dette produkt være udstyret med et 3-leders jordingsstik, et stik med et tredje (jordings)ben. Dette stik passer kun i en stikkontakt med jordforbindelse. Dette er en sikkerhedsfunktion. Tving ikke stikket til at passe ind i en inkompatibel stikkontakt eller på anden måde forsøge at omgå stikkets sikkerhedsformål. Hvis din stikkontakt ikke er kompatibel med stikket, skal du kontakte din elektriker for at udskifte din stikkontakt med en, der er kompatibel.
  11. Beskyttelse af netledninger – Før strømforsyningsledninger, så de ikke kan trædes på eller klemmes af genstande placeret på eller imod dem, og vær særlig opmærksom på ledninger og stik, stikkontakter og det sted, hvor ledningerne kommer ud af apparatet .
  12.  Elledninger – Anbring ikke et udendørs system nogen steder i nærheden af ​​luftledninger eller andet elektrisk lys eller strømkredsløb, eller hvor det kan falde ind i sådanne strømledninger eller kredsløb. Når du installerer et udendørs system, skal du være yderst forsigtig med at undgå at røre sådanne elledninger eller kredsløb, da kontakt med dem kan være livsfarlig.
  13. Overbelastning – Overbelast ikke stikkontakter og forlængerledninger, da dette kan forårsage brand eller elektrisk stød.
  14. Indtrængning af genstande og væsker – Skub aldrig genstande af nogen art ind i dette produkt gennem åbninger, da de kan røre ved farlig volumtage punkter eller kortslutte dele, som kan forårsage brand eller elektrisk stød. Spild aldrig væske af nogen art på produktet.
  15.  Service – Forsøg ikke selv at servicere dette produkt, da åbning eller fjernelse af dæksler kan udsætte dig for farlig volumtage eller andre farer. Henvis al servicering af produktet til Linortek.
  16. Skader, der kræver service – Tag produktets stik ud af stikkontakten, og henvis service til Linortek kundesupport under følgende forhold:
    en. Når strømforsyningens ledning eller stik er beskadiget.
    b. Hvis der er spildt væske, eller der er faldet genstande ned på produktet.
    c. Hvis produktet har været udsat for regn eller vand.
    d. Hvis produktet ikke fungerer normalt ved at følge betjeningsvejledningen [følger med produktet]. Juster kun de kontroller, der er dækket af betjeningsvejledningen, da en forkert justering af andre kontroller kan resultere i skader og ofte vil kræve omfattende arbejde af en kvalificeret tekniker for at genoprette produktet til dets normale funktion.
    e. Hvis produktet er faldet, eller kabinettet er blevet beskadiget.
    f. Hvis produktet udviser en markant ændring i ydeevnen.
  17. Udskiftningsdele – Hvis udskiftningsdele er nødvendige, skal du have en Low-Voltage Elektriker udskifter dem med kun dele, der er specificeret af producenten. Uautoriserede udskiftninger kan resultere i brand, elektrisk stød eller andre farer. Reservedele kan findes på https://www.linortek.com/store/
  18. Sikkerhedstjek – Efter afslutning af enhver service eller reparation af dette produkt, bede serviceteknikeren om at udføre sikkerhedstjek for at fastslå, at produktet er i korrekt driftstilstand.
  19.  Koaksialjording – Hvis et eksternt kabelsystem er tilsluttet produktet, skal du sørge for, at kabelsystemet er jordet. Kun amerikanske modeller – Afsnit 810 i National Electrical Code, ANSI/NFPA No.70-1981, giver oplysninger om korrekt jording af monteringen og den understøttende struktur, jording af koaksialet til et afladningsprodukt, størrelsen af ​​jordledere, placering af afladningsprodukt, tilslutning til jordingselektroder og krav til jordingselektroden.
  20.  Lyn – For yderligere beskyttelse af dette produkt under et tordenvejr, eller før du efterlader det uden opsyn og ubrugt i længere perioder, skal du trække det ud af stikkontakten og frakoble kabelsystemet. Dette vil forhindre skader på produktet på grund af lynnedslag og overspænding i strømforsyningen.
  21.  Udendørs brug - Dette produkt er ikke vandtæt og må ikke blive vådt. Udsæt ikke for regn eller andre typer væske.
    Efterlad ikke udendørs natten over, da der kan opstå kondens.
  22.  Når du skifter batterier, sikringer eller håndterer et produkt i niveau med kort, skal du være forsigtig med elektrostatisk afladning, som kan beskadige elektroniske enheder. Det er bedst at bruge en jordet elektronisk servicebænk. Hvis dette ikke er tilgængeligt, kan du aflade dig selv ved at røre ved et metalapparat eller et rør. Under udskiftning af batterier eller sikringer må du ikke røre i) andre ledninger end batteriledningerne og ii) printkortet.

BEGRÆNSNING AF ANSVAR
IN NO EVENT WILL LINOR TECHNOLOGY BE LIABLE, WHETHER IN CONTRACT, TORT, OR OTHERWISE, FOR ANY INCIDENTAL, SPECIAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES, INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, OR LOST PROFITS, SAVINGS, OR REVENUES TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. DISCLAIMER FOR CRITICAL APPLICATIONS
Dette produkt er ikke beregnet til eller godkendt til livsstøttende produkter eller til andre formål, hvor en fejl kan forårsage personskade eller død. Hvis du eller dine kunder bruger eller tillader brugen af ​​dette produkt til sådanne utilsigtede eller uautoriserede anvendelser, accepterer du fuldt ud at holde Linor Technology og dets tilknyttede selskaber og hver enkelts embedsmænd, medarbejdere og distributører skadesløs for alt ansvar relateret til sådan brug, inklusive advokatsalærer og omkostninger.
YDERLIGERE MEDDELELSE OM BEGRÆNSNING AF BRUG
Medmindre det er specifikt angivet, er vores produkter IKKE designet til at skifte linjevolumentage (110V og derover) enheder. Til at styre enhed, der fungerer ved linje voltages en kvalificeret elektriker SKAL installere en mellemliggende enhed såsom et relæ. Når du vælger enheder til styring, er det bedst at vælge lav voltage kontroller såsom en 24VAC solenoide til vand flow kontrol. Kun kvalificerede elektrikere må tilslutte en ledning voltage enhed. Derudover skal lokale regler følges, herunder men ikke begrænset til trådmålerstørrelse og passende hus. Linortek påtager sig intet ansvar for skade på brugeren eller tredjeparter for forkert brug af vores produkter. Dette ansvar forbliver hos brugeren. Linortek påtager sig intet ansvar for skader på enheden på grund af forkert brug af vores produkter.
RELÆ VOLTAGE SPECIFIKATIONER
Vær forsigtig, når du tilslutter enheder til elektriske kredsløb eller andet udstyr. Dette web controlleren er IKKE designet til at forbinde til nogen voltage greater than 48V. Utilizing this arrangement, should allow you to virtually control anything. It is important that  you use licensed electricians and comply with electrical codes that are applicable to your location. These codes exist for your safety, as well as the safety of others. Linortek assumes no responsibility for any harm or damage resulting from a failure adhere to local laws, ordinances or regulations or failure to follow specified instructions for installation and product usage.

Slutbrugerlicensaftale for Linortek Software og dokumentation

Denne slutbrugerlicensaftale ("EULA") er en juridisk aftale mellem DIG (en enkeltperson eller enkelt enhed) og Linor Technology, Inc. ("Linortek" eller "vi" eller "os"), der regulerer din brug af softwaren og dokumentation ("Software"), der er indlejret i eller forbundet med Fargo-, Koda-, Netbell-, IoTMeter- og iTrixx-serien af ​​produkter ("Linortek-produkter").
Denne slutbrugerlicensaftale regulerer ikke din brug af Linortek webwebstedet eller Linortek-produkterne (undtagen softwaren). Din brug af Linortek webwebstedet er styret af Linortek webwebstedets servicevilkår og Linortek's privatlivspolitik, som kan findes på:
http://www.linortek.com/terms-and-conditions [Dit køb af Linortek-produkter (undtagen softwaren) er underlagt Linortek's begrænsede garanti, som kan findes på https://www.linortek.com/linortek-one-year-limited-warranty/
This EULA governs your access and use of the Software. This EULA gives you specific legal rights, and you may also have other legal rights in addition, which vary from jurisdiction to jurisdiction. The disclaimers, exclusions, and limitations of liability under
this EULA will not apply to the extent prohibited or limited by applicable law. Some jurisdictions do not allow the exclusion of implied warranties or the exclusion or limitation of incidental or consequential damages or other rights, so those provisions of this EULA may not apply to you.
Ved at installere, få adgang til, kopiere og/eller bruge softwaren eller dokumentationen accepterer du at være bundet af vilkårene og betingelserne i denne EULA på vegne af dig selv eller den enhed, du repræsenterer i forbindelse med sådan installation, adgang, kopiering og/eller brug. Du repræsenterer og garanterer, at (i) du har ret, autoritet og kapacitet til at acceptere og acceptere vilkårene i denne slutbrugerlicensaftale på vegne af dig selv eller den enhed, du repræsenterer (ii) du er af tilstrækkelig lovlig alder i din bopælsjurisdiktion , (iii) du ikke befinder dig i et land, der er underlagt en embargo af den amerikanske regering, eller som er blevet udpeget af den amerikanske regering som et "terroriststøttende" land; og (ii) du ikke er opført på nogen amerikanske regerings liste over forbudte eller begrænsede parter.
Hvis du ikke ønsker at være bundet af vilkårene i denne EULA, må du ikke installere, få adgang til, kopiere eller bruge softwaren på nogen måde (uanset om den er forudinstalleret på en enhed, du har købt).

  1. Tilladt brug af software/softwarelicens.
    I henhold til vilkårene i denne EULA giver Linortek dig en begrænset, tilbagekaldelig, ikke-eksklusiv, ikke-underlicenserbar, ikke-overdragelig ret og licens til (a) at downloade, installere og udføre en kopi af softwaren i eksekverbar objektkodeform kun, udelukkende på Linortek-produktet, som du ejer eller kontrollerer, og til (b) at bruge softwaren udelukkende i forbindelse med Linortek-produktet i overensstemmelse med dets tilsigtede brug som beskrevet på Linortek webwebsted (hver af 1(a) og 1(b) en "Tilladt brug" og samlet "Tilladte anvendelser").
  2. Begrænsninger for din brug af softwaren.
    Du accepterer ikke og ikke at tillade andre at bruge softwaren til andre formål end de tilladte anvendelser beskrevet i afsnit 1 ovenfor. Det betyder blandt andet, at du ikke må:
    (a) redigere, ændre, ændre, tilpasse, oversætte, lave afledte værker af, adskille, reverse engineering eller reverse-kompilere nogen del af softwaren (undtagen i det omfang gældende love specielt forbyder en sådan begrænsning af hensyn til interoperabilitet, i hvilket tilfælde du accepterer først at kontakte Linortek og give Linortek mulighed for at skabe sådanne ændringer, som er nødvendige af hensyn til interoperabilitet);
    (b) licensere, tildele, distribuere, transmittere, sælge, udleje, hoste, outsource, offentliggøre eller på anden måde bruge softwaren til ethvert kommercielt formål eller gøre softwaren tilgængelig for en tredjepart;
    (c) tillade en tredjepart at bruge softwaren på vegne af eller til fordel for en tredjepart;
    (d) bruge enhver del af softwaren på enhver anden enhed eller computer end Linortek-produktet, som du ejer eller kontrollerer;
    (e) bruge softwaren på enhver måde, der overtræder enhver gældende lokal, national eller international lov; eller
    (f) remove or alter any labels, symbols, legends or proprietary notices, including but not limited to any copyright, trademark, logo in the Software. You may not disclose the results of any performance or functional evaluation of anyof the Software to any third party without the prior written consent of Linortek for each such release.
  3. Opdateringer.
    Linortek kan fra tid til anden udvikle opdateringer, opgraderinger, patches, fejlrettelser og andre ændringer ("Opdateringer") for at forbedre softwarens ydeevne. Medmindre andet er angivet på Linortek webwebsted, vil disse opdateringer blive leveret til dig gratis. Disse opdateringer kan blive installeret automatisk uden varsel til dig. Ved at bruge softwaren giver du også samtykke til automatiske opdateringer. Hvis du ikke accepterer dette, må du ikke installere, få adgang til, kopiere eller bruge softwaren på nogen måde.
  4. Ejendomsret.
    The Software is licensed to you and not sold. Linortek reserves all rights to the Software and any Updates not expressly granted herein. The Software and Linortek Products are protected by copyright, trademark and other intellectual property laws andtreaties. Linortek and its licensors own the title, copyright, trademarks and other intellectual property rights in the Software.
    You are not granted any rights to Linortek’s trademarks or service marks. There are no implied licenses in this EULA.
  5. Afslutning.
    This EULA is effective from the date you first use the Software and will continue for as long as you own the Linortek Product associated with it or until you or Linortek terminate this agreement under this section. You may terminate this EULA at any time upon written notice to Linortek at the address provided below. Linortek may terminate this EULA at any time if you fail to comply with any of the terms in this agreement. The license granted in this EULA terminates immediately when the agreement terminates. Upon termination, you must stop using the Linortek Product and the Software and you must delete all copies of the
    Software. The terms of Sections 2 will still remain in effect after the agreement terminates.
  6.  Ansvarsfraskrivelse for garanti.
    EXTENT PERMITTED BY APPLICABLE LAW, LINORTEK PROVIDES THE SOFTWARE “AS-IS” AND DISCLAIMS ALL WARRANTIES AND CONDITIONS, WHETHER EXPRESS, IMPLIED, OR STATUTORY, INCLUDING THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, QUIET ENJOYMENT, ACCURACY, AND NON-INFRINGEMENT OF THIRD-PARTY RIGHTS. LINORTEK DOES NOT GUARANTEE ANY SPECIFIC RESULTS FROM THE USE OF THE SOFTWARE. LINORTEK MAKES NO WARRANTY THAT THE SOFTWARE WILL BE UNINTERRUPTED, FREE OF VIRUSES OR OTHER HARMFUL CODE, TIMELY, SECURE, OR ERROR-FREE. YOU USE THE SOFTWARE AND THE LINORTEK PRODUCT AT YOUR OWN DISCRETION AND RISK. YOU WILL BE SOLELY RESPONSIBLE FOR (AND LINORTEK DISCLAIMS) ANY AND ALL LOSS, LIABILITY, OR DAMAGES RESULTING FROM YOUR USE OF THE SOFTWARE
    AND LINORTEK PRODUCT.
  7. Ansvarsbegrænsning.
    Intet i denne EULA og i særdeleshed i denne "Ansvarsbegrænsning"-klausul skal forsøge at udelukke ansvar, som ikke kan udelukkes i henhold til gældende lovgivning.
    I DET MAKSIMALTE OMFANG, DET ER TILLADT I HENHOLD TIL GÆLDENDE LOV, UDOVER OVENFOR GARANTIFRASKRIVELSER, ER LINORTEK UNDER INGEN OMSTÆNDIGHEDER (A) ANSVARLIG FOR NOGEN FØLGE-, EKSEMPEL-, SPECIELLE ELLER TILFÆLDIGE SKADER, INKLUSIVE SKADER, INKLUSIVE SKADER. FRA ELLER I FORBINDELSE MED PRODUKTERNE ELLER SOFTWAREN, SELVOM LINORTEK KENDTE ELLER BURDE HAVE KENDT TIL MULIGHEDEN FOR SÅDANNE SKADER OG (B) LINORTEKS SAMLEDE KUMULATIVE ANSVAR SOM OPSTÅR FRA DEN ELLER RELATEREDE PRODUKTER I HENHOLD TIL ANDET ELLER TILSÆTTEDE PRODUKTER. SKAL VÆRE BEGRÆNSET TIL ET BELØB, DER ALDRIG SKAL OVERstige DET BELØB, DER FAKTISK BETALTES AF DIG TIL LINORTEK OG LINORTEKS AUTORISEREDE DISTRIBUTØR ELLER SALGSREPRÆSENTANT FOR DE PÅGÆLDENDE PRODUKTER ELLER TJENESTER I DE FORUDSIDE 6 MÅNEDER. DENNE BEGRÆNSNING ER KUMULATIV OG VIL IKKE FORØGES VED TILSÆTTEN AF MERE END ÉN HÆNDELSE ELLER KRAV. LINORTEK FRASKRIVER SIG ALT ANSVAR FOR ENHVER FORM AF LINORTEKS LICENSGIVERE OG LEVERANDØRER.
  8. Overholdelse af eksportlovgivningen.
    Du anerkender, at softwaren og relateret teknologi er underlagt amerikanske eksportkontrollove. USAs eksportjurisdiktion og kan være underlagt eksport- eller importregler i andre lande. Du accepterer strengt at overholde alle gældende internationale og nationale love og regler, der gælder for softwaren, inklusive de amerikanske eksportadministrationsbestemmelser samt slutbruger-, slutbrugs- og destinationsrestriktioner udstedt af amerikanske og andre regeringer. Du anerkender, at du har ansvaret for at opnå tilladelse til at eksportere, reeksportere eller importere softwaren og relateret teknologi, alt efter hvad der er nødvendigt.
    Du vil holde Linortek skadesløs for ethvert krav, tab, ansvar, skader, bøder, bøder, omkostninger og udgifter (inklusive advokatsalærer), der opstår fra eller relaterer til enhver misligholdelse fra din side af dine forpligtelser i henhold til dette afsnit.
  9. Opgave.
    Du må ikke overdrage nogen af ​​dine rettigheder eller forpligtelser i henhold til denne EULA, og ethvert forsøg på at overdrage vil være ugyldigt og uden virkning.
  10. Meddelelser.
    Linortek kan give dig en hvilken som helst meddelelse i forbindelse med denne slutbrugerlicensaftale ved hjælp af den e-mail og adresse, som du har angivet, da du registrerede dig hos Linortek.
  11. Afkald
    For at være effektive skal enhver og alle dispensationer fra Linortek nedenfor være skriftlige og underskrevet af en autoriseret Linortek-repræsentant. Enhver anden undladelse fra Linortek til at håndhæve ethvert vilkår heri vil ikke blive betragtet som et frafald.
  12.  Uafhængighed.
    Enhver bestemmelse i denne slutbrugerlicensaftale, som ikke kan håndhæves, vil blive redigeret og fortolket for at opnå formålene med denne bestemmelse i videst muligt omfang under gældende lovgivning, og alle resterende bestemmelser forbliver i fuld kraft og virkning.
  13. Lovvalg; Mødested.
    You agree that this EULA, and any claim, dispute, action, cause of action, issue, or request for relief arising out of or relating to this EULA, will be governed by the laws of the state of North Carolina, U.S.A., without regard to conflicts of laws principles, provided that if you reside in a country that will not apply U.S. law to disputes related to these terms, then the laws of your country will apply. You also agree that the United Nations Convention on Contracts for the International Sale of Goods shall not
    apply. You agree that regardless of any statute or law to the contrary, any cause of action against us arising out of or related to the Linortek webwebstedet, softwaren eller Linortek-produkterne skal påbegyndes inden for et (1) år efter, at sagsårsagen er opstået, ellers skal en sådan sagsårsag være permanent spærret. Enhver sag eller procedure i forbindelse med denne slutbrugerlicensaftale skal anlægges ved en føderal eller statslig domstol i Raleigh, North Carolina, og hver part underkaster sig uigenkaldeligt jurisdiktionen og værnetinget for en sådan domstol i et sådant krav eller tvist, bortset fra at Linortek kan søge påbud fritagelse for enhver domstol, der har kompetence til at beskytte sin intellektuelle ejendom.
  14. Californiens forslag 65 advarsel.
    ADVARSEL: Dette produkt kan udsætte dig for kemikalier, herunder bly, som er kendt af staten Californien for at forårsage kræft. For mere information, gå til www.P65Warnings.ca.gov.

Kom godt i gang

The Fargo SERVER is what is called a “bare board” product and is supplied without a housing. It operates on low voltage; however you need to use simple handling precautions to prevent damage to the circuits. All electronics are susceptible to electrostatic discharge. This high voltage “shock” can permanently damage your device. Before handling the product, you should touch a surface such as a grounded workbench or table. It is also best to handle the device from its edges. If you notice that your chair or clothes often cause static discharges, you must exercise extra caution. The unit is supplied with four rubber feet which keeps the bottom of the board from coming into contact with the surface you put it on. Be careful not to let metal objects, such as screw drivers or hardware, come in contact with the bottom of this product. The board can be mounted on a panel using stand offs and #4 hardware. The mounting holes are connected to the GROUND signal. The SERVER unit is a self-contained web server configured with various input and output circuits. Although the relays are rated for higher voltages, dette produkt er ikke designet til brug på line voltages. You should never use voltages through the SERVER product exceeding 48 volts. IT IS NOT SAFE.
The KODA SERVER is a housed unit with a DIN rail mountable enclosure that can be snapped onto a DIN rail or attached to any flat surface such as a wall or under a counter. KODA 100 has two relays (48VAC@1A), KODA 200 has four relays which can drive 10V 50mA to external devices. The unit is supplied with a DIN Rail mountable enclosure with removable terminal connectors for easy installation. The KODA SERVER can be mounted on a panel or on the wall using the DIN rail mount clip. The removable wire terminal connectors simplify field installation and allow for easy troubleshooting and maintenance: the unit can be removed from the system without disturbing the system wiring.

Kabelføring til serveren
Note: For a diagram showing the location of all connectors on your SERVER referenced in this section, please see the section – Board Layout Reference.
Forsigtighed: Disse enheder er jordisolerede. Tilslut altid, så strømsløjfen kun er tilsluttet SERVER-enheden.
Brug IKKE eksterne jordforbindelser. Hvis du gør det, kan det beskadige SERVER- eller POE-enheden.

  1. Place the unit on a table or bench being careful not to let any metal objects come into contact with the bottom of the circuit board (Fargo Only).
  2. Connect the 12VDC power supply to a suitable AC outlet and plug the barrel connector into the SERVER at the location labelled “12VDC/POWER”. Alternatively, you may also use POE. At this point the GREEN/Boot LED should come on and start flashing indicating the SERVER is operating and is in the “Bootload Mode”. This mode allows the user to update the server software that is used on the unit. After about 5 seconds, the GREEN LED will go off and the RED LED will start blinking once per second indicating the SERVER is operating in “Server Mode” and is accessible on a network utilizing TCP/IP protocols.
    FORSIGTIGHED: NÅR DU BRUGER POE NETVÆRKSKONTAKT, MÅ DU IKKE BRUGE 12VDC STRØMFORSYNING TIL AT FORSTYRE SERVEREN PÅ SAMME TID, VIL DET SKADE KORTET.
  3. Plug an Ethernet cable into the RJ45/NET connector. The “Connection” LED will come on if a 100MHz network is available, otherwise it will remain off and the “Activity” LED should start blinking indicating network activity. Fargo G2 Relay Connections
    There are 8 relays on the FARGO R8 and 4 on the FARGO R4. These are dry contact relays. These units are designed for only low voltage kontrol og bør ikke have en voltage applied to the relay greater than 48 volts. This is for your safety as well as to stay within the parameters of the parts and circuit board design. The relays have 3 terminals labelled NO, C and NC which stand for Normally Open, Common and Normally Closed. When activated, the relay moves the connection from CNC to CNO. If you want to make a connection when the relay is activated, connect your wires between C and NO. When the relay is activated C and NO will be connected together. If you want to break a circuit when the relay is activated, make your connections to C and NC. When the relay is activated the circuit will be broken (or open)
    Koda Relay Connection
    There are 2 relays on the KODA 100. The KODA 100 has 2 removable 2 position connectors (1 for each relay) and are simply numbered “1” and “2”. These relays are normally open.
    There are 4 relays on the KODA 200. The KODA 200 has 1 removable 8 position connector. Each relay has a “+” connection and a numbered connection. The relays may be set to supply about 10VDC by selecting “+V” on the setting switch (see Board Layout Reference page 29) or set to dry contact DC on the switch. If “+V” is selected then the voltage will be present on the “+” terminal and the numbered terminal is the return. Otherwise, a normally open dry contact exists across the “+” and numbered connection. KODA 100/200 is designed for only low voltage kontrol og bør ikke have en voltage påført relæet mere end 48 volt. Dette er for din sikkerhed såvel som for at holde dig inden for parametrene for dele og printkortdesign.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Koda Relay Connection

advarsel - 1 LINOR TEKNOLOGI VIL UNDER INGEN OMSTÆNDIGHEDER VÆRE ANSVARLIG, HENST I KONTRAKT, TORT ELLER ANDEN MÅDE, FOR NOGEN TILFÆLDIGE, SÆRLIGE, INDIREKTE, FØLGESKADER ELLER STRAFSKADER, INKLUSIVE, MEN IKKE BEGRÆNSET TIL, SKADER I UDEN TID, UDEN TIDS, , KOMMERCIELT TAB ELLER MISTET FORTJENESTE, OPSPARINGER ELLER INDTÆGTER I FULD OMFANG, SÅDAN KAN FRASKRIVES AF LOVEN.

YDERLIGERE MEDDELELSE OM BEGRÆNSNING AF BRUG
Medmindre det er specifikt angivet, er dette produkt IKKE designet til at skifte linjevolumentage enheder. Denne begrænsning omfatter alle FARGO OG KODA produkter. Til at styre enhed, der fungerer ved linje voltages brugeren SKAL installere og mellemliggende enhed såsom et relæ.
Ved ledning af en ledning voltagEn enhed, der bruger mellemliggende enhed, SKAL enten være en kvalificeret elektriker eller bruge en kvalificeret elektriker. Derudover skal lokale forskrifter følges, herunder, men ikke begrænset til, trådmålerstørrelse og passende hus.
Linortek cannot assume any responsibility for harm to the user or third parties for improperly using our Fargo/Koda products. This liability remains with the user. Linortek cannot assume any responsibility for damage to the device for improperly using our SERVER product.
For relay specifications, please see Board Reference Layout page 29
Digital Input Connections (Fargo R4 and Koda)
The digital inputs allow the SERVER to detect an external on/off state of a sensor. With this information the SERVER can display whether an input is on or off, count events in a resettable or non-resettable counter, and calculate the frequency (such as for use as a tachometer) or the period of the input. There are two modes of operation for the digital inputs – PULL UP and ISOLATED.
a) PULL UP mode connects a 1K resistor to an internal voltage, så du kan bruge en simpel kontakt (såsom en magnetisk dørkontakt) på tværs af klemme 1 og 2. Dette, når kontakten aktiveres, sendes et signal til indgangen.
b) ISOLATED mode allows you to directly drive the SERVER’s optoisolator with an external voltagdog en intern 1K modstand. Denne bindtage kan være i området fra 5V til 24V, der leverer minimum 2mA eller maksimalt 30mA til optoisolatordioden. Der er ingen anden intern forbindelse til denne bindtage so it is an isolated input. Please note, when connecting a 12VDC-¬24VDC circuit to the input, an external resistor (can be provided at request, 2.2k ohm 0.5watt) must be used.
These modes are selected by the switch on the SERVER (see Board Layout Reference page 29) marked ISO and PU for isolated and pull up respectively. These are set at the factory to ISO by default.
Wiring a push button: For distances up to 500 feet, a 20 AWG shielded wire is suitable for wiring a push button. If the distance between the push button and the controller extends up to 5,000 feet, use a 16 AWG shielded cable instead. Keep in mind that longer cable runs are more susceptible to signal interference.
Forsigtighed: If you intend to use isolated mode, verify that the input switch is set to ISO before applying an external voltage. Hvis du gør andet, kan det beskadige SERVER- eller POE-enheden.
Analog Input Connections (Fargo R4ADI)
The analog inputs allow the SERVER to read the value of external equipment. There are 2 analog inputs.
For AC current monitoring, use one of the two 3.5mm stereo inputs to interface with a current sensor.
De 2 analoge indgangsklemmer er forbundet til ikke-isolerede 0-5V strømsensorer, som kan tilsluttes en række forskellige enheder såsom temperatur- eller tryksensorer. SERVEREN giver en jord- og strømforbindelse, så målinger kan foretages uden ekstern voltage references. You should use a sensor that is isolated so that that it makes no connection to a remote ground. See drawing under Board Reference Layout page 29.
Accessing your SERVER
Når din SERVER er tændt og tilsluttet netværket, vil den automatisk få en IP-adresse via DHCP, så længe din router er konfigureret til at gøre det. For at oprette forbindelse skal du indtaste IP-adressen i din web browser. This will take you to your SERVER’s landing page. To log in, click the Log In button on the top right of the page. Your browser will prompt you to enter your username and password. By default, these credentials are both set to admin. To find your SERVER’s IP address, see below.
Find din IP-adresse med Linortek Discoverer
Discoverer-programmet vil automatisk finde din SERVER. Discoverer er et Java-program og kræver, at Java Runtime er installeret for at bruge denne funktion. Java kan findes her: http://java.com/en/download/index.jsp.
For at downloade Discover-programmet skal du gå til: https://www.linortek.com/downloads/supportprogramming/
Brug af Chrome- og Firefox-browsere anbefales. Bemærk venligst: Hvis du foretrækker at bruge Internet Explorer, gemmer Internet Explorer Linortek Discoverer som en Zip file som standard. For at bruge Discoverer skal du vælge Gem som og omdøbe file som Linortek Discoverer.jar, når du downloader.
Når du downloader Discover-programmet, vil du nogle gange se en popup-advarselsmeddelelse afhængigt af din browsers sikkerhedsindstillinger, der spørger, om du vil beholde eller kassere denne file, please click the Keep button as this is a Java program, and it won’t harm your computer.
Når Discoverer har fundet din enhed, vil den vise:

  1. IP-adresse
  2. Værtsnavn
  3.  MAC-adresse
  4. Andre oplysninger:
    en. Blå LED (hvis tændt)
    b. produktnavn
    c. Revision af serversoftware
    d. Portnummer (hvis porteret)

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- IP Address

Klik på den enhed, du vil bruge, vist på Discoverer-programmet for at starte SERVEREN web pages in your browser. Click the Login button on the homepage. The default username/password is: admin/admin. You may change these as you desire or disable this feature in the settings menu.
Connecting your SERVER Directly to Your PC
You can also plug your SERVER directly to your PC if there is no network connection available. If you plug your SERVER into your PC’s Ethernet port it will use the default IP address: 169.254.1.1 unless you have previously configured your SERVER to use a static IP. Enter 169.254.1.1 into your web browser to connect. No internet connection is required. Once configured, you can then install your SERVER where you desired.

Serverkonfiguration
Log ind
Once you have entered the IP address and port number, if set, the Login page will open. This page shows the name of this server which you may change in Configure/Network Config.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Logging In

This page is static with no background activity and is a useful place to park if you are not using the SERVER and do not want to close the connection.
By pressing LOGIN, you will be asked for your username and password. These credentials will be retained by the browser until the browser is closed. You can disable the password requirement in Settings page. See section page 21.
Hjemmeside
Når dine loginoplysninger er indtastet, vil du blive omdirigeret til applikationens hovedside. Hjemme- eller indekssiden viser nogle af systemoplysningerne og giver mulighed for at lokalisere den fysiske enhed, hvis den er i et område med andre. Se listen nedenfor for beskrivelse.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Home Page

  • TIME – Displayed along with the day of the week. This time may be set to be in a 12 hour format with AM/PM indicator or 24 hour format.
  • DATO – Nuværende dato vises her.
  • VOLTS – Voltage på tavlen vises. Dette kan være nyttigt, hvis SERVEREN drives sammen med andet udstyr, voltage variance can be noted. Fargo and Koda servers have an input voltage range of 1248vDC.
  • TEMPERATURE – Temperature on the board is displayed. This display may be either °C or °F. This temperature will be affected by the heat generated by SERVER itself so it will always be slightly higher than ambient temperature.
  • LED'er – Der vises 3 LED'er. Den RØDE LED er systemets puls. Dette bør blinke cirka en gang i sekundet, så længe serveren kører. Den GRØNNE LED bruges til bootloader-indstillinger og er generelt ikke synlig på webwebsted. Den BLÅ LED er klikbar, og du kan tænde og slukke den fra denne web side. Dette er nyttigt til at lokalisere enheden fysisk, hvis den skal bruges sammen med andre lignende enheder, da den vil lyse på den enhed, som denne web browseren er tilsluttet. Discoverer-programmet vil også notere, om den BLÅ LED er tændt. Dette omtales ofte som en "Find"-funktion.

Tjenester
Fanen Tjenester er dynamisk og vil ændre sig afhængigt af konfigurationen af ​​din server. Det er her, du kan styre indgange, udgange, sensorer og andre specialstyringer.
In/Out or Relays Page
Depending on which SERVER you are using, the first page on the SERVICES tab will be either In/Out or Relays.
In/Out has the relay controls and the input controls on one page, while Relays only has the relay controls.
Relæ kontrol
An In/Out page is displayed below. Some relay control pages have 2, 4 or 8 relays displayed. Each relay has a number, in this case 1 to 4.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Home Page1

The State LED shows whether the relay is on or off indicated by GREEN and RED respectively. This icon is clickable to manually control the corresponding relay. Each relay can have a Name as well as identifiers for the Normally Open, Common and Normally Closed connections.
Der er fire status-LED'er, der viser:

  1. Email – If an email is to be sent when this relay is switched on/off
  2. Puls – Hvis dette relæ er indstillet med en pulsbredde og pulsbredde multiplikator (varighed) – se næste afsnit for mere information
  3.  Sched. – If there is a schedule created in the Tasks page (see page 15) set to automatically trigger this relay.
  4.  Tidsindstillet – Hvis pulsen er indstillet, og dette relæ er aktiveret, vil den tidsindstillede LED blive rød, hvilket viser, at relæet i øjeblikket kører på en timer.

Click the Edit Icon to edit the controls for the corresponding relay. This will take you to the Set Relay page (see page 11).
Indgange
The In/Out or Inputs page (depending on your SERVER) will display information from each input. The SERVERs have a combination of inputs. The Fargo R4DI has four digital inputs, The R4ADI has, four digital inputs, four analog inputs. The KODA SERVER has two digital inputs.
At the top of each input is a label (ex: DIN 1, AIN 2) specifying whether it is a digital input (DIN) or analog input (AIN) as well as the input number. This label will turn green when the input is enabled. Inside the box will be any display configured from the Set Input page (see page 12 for digital input, page 14 for analog input). A red dot in the lower-left corner indicating the state of a linked relay (if any), will turn green when the linked relay is activated.
Finally, an Edit icon in the lower-right corner of the box to edit the corresponding input. This will take you to the Set Digital Input or Set Analog Input page (page 12 or page 14).
Set Relay Page
Siden SET RELAY giver dig mulighed for at indstille forskellige egenskaber, der vedrører relæet.

  1. Relay Select – The Relay that you are editing (identified by the line on which you clicked the Edit icon on the RELAY page).
  2. Name – Enter a 15-character Relay Name. This and the following 3 fields may be used for any identifying information desired.
  3. NO Name – Enter a 7-character name for the Normally Open (NO) connection.
  4. Com Name – Enter a 7-character name for the Common (COM) connection.
  5. NC Name – Enter a 7-character name for the Normally Closed (NC) connection.
  6. Pulse Width – When you control the relay it turns on or off. You may control it for a timed turned on period by entering a Pulse Width when 0 means there is no timed event and a number represents duration of the pulse. The maximum number you can enter here is 4 digits, ie. 1234.
  7. Pulsbredde-multiplikator – For yderligere at definere pulslængden vælg en pulsbredde-multiplikator for yderligere at definere pulsbredden. Du kan vælge:
    • Ingen
    • mS (Millisecond, 1/1000 second)
    • Sec (Seconds)
    • Min (Minutes)
  8. Relætype – SERVEREN kan få adgang til relæer fysisk på SERVEREN eller ved hjælp af andre midler. Du kan vælge:
    • Normal – relay physically on the SERVER
    • Latched – not currently supported
    • Remote – a relay on another SERVER accessed over the network
    • Zigbee – a relay at a remote device accessed over an RF system
    • Normal and Remote – both relays activated
    • Normal and Zigbee – both relays activated
  9. Lokations-id – dette er et nummer, der identificerer en fjernplacering
  10. Relæ på lokationen – et tal, der repræsenterer relæet eller enheden på lokationen
  11. Send e-mail – SERVEREN kan programmeres til at sende en e-mail, hvis relæet er tændt eller slukket.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- set

Indstil digital inputside
De digitale indgange kan indstilles til at give forskellige udlæsninger ved brug af en række skærmtyper. Ud over at vise inputdataene kan du navngive displayet samt knytte et relæ til det. Dette relæ vil skifte fra grønt til RØD, efterhånden som det går fra on til off samt er klikbart for at styre det. Ved at klikke på rediger blyantikonet kan du redigere indstillingerne for dette input:

  1. Digital Input Selected – The Digital Input that you are editing (identified by the line on which you clicked the Edit icon).
  2. Navn – Du kan indstille et navn på 15 tegn for denne indgang. Dette navn vises i bjælken øverst på skærmen.
  3. Etiket – Indstil en etiket på 7 tegn, som vises på det faktiske aktive display.
  4. Korrektor – Ved at bruge dette felt kan du addere, subtrahere, gange eller dividere en værdi, før værdien vises på displaysiden. Dette er en korrektor med 2 værdier, hvor hver er adskilt af et enkelt mellemrumstegn. (dvs. "+2, -2, *3, /3")
  5. BRUG – Indstiller denne indgang til aktiv. Drejer indtastningsnummerindikatoren til grøn. Det skal bemærkes, at inputtet, når det er i brug, bruger CPU-tid og andre ressourcer afhængigt af dets type. Selvom alle indgange kan være aktive på samme tid, anbefales det kun at tænde dem, du vil bruge.
  6.  Type – Inputdataene kan bruges til at beregne en række resultater. Du kan vælge:
    • State – This is useful for knowing if an input is on or off, like a door switch being on or off.
    • CounterNR – This is a non-resettable counter.
    • CounterR – This is a resettable counter.
    • Frequency – Counts the frequency of an input in KHz (kilo hertz or1/1000 seconds). This could be useful in displaying a tachometer where 60Hz = 1 R.P.M.
    • Period – in 1/1000 seconds an input in kHz (milliseconds or1/1000 seconds). This would be useful for measuring timed events.
  7.  Display – Dette valg lader dig ændre den anvendte displaytype. Du kan vælge:
    • Dot – A single dot with the value in the middle. This can be used for State. You can make a dumb indicator by changing the color of the Dot based on the value. The label is under the Dot.
    • Values – Displays the Corrected Value with the Label in a box directly below it.
    • Meter – This Meter has configurable scale based on the Min/Max values and arcs can be colored per the Color ranges. The Label is displayed within the Meter.
    • VBar – Also based on the Min/Max values for the scale and the bar changes color based on the values in the Color ranges.
  8. Relay L/T – Enter a Relay number here. If it is a local relay it will show GREEN or RED depending if it is on or off. By clicking on it the relay will turn on and off. The name comes from the relay settings page. This may be useful if you want to turn the subject of a display on and off. Any relay can be used on any input and each may be reused for any other input. Adding an L after the relay number (ex: 2L) will link the state of the input to the state of the relay. This is an easy and immediate way to have an input follow the relay. Adding a T after the relay number will trigger the relay to the state of the input. This is an easy and immediate way to have a relay follow the input.
  9.  Command Z/N/I – This field is used for issuing various commands to the Digital Input controller: Z Zero the resettable counter. N Leave the input as Normal. I Invert the input.
  10. Value – These are Min/Max values used for the display. This is useful for preventing a Meter from going past its end or setting the value of a VBar. This is the Value after the Corrector. The system cannot display a value past Max, so be sure this is at least set to 1.
  11. Gul/Rød/Grøn – Der er tre farver, der kan bruges til yderligere at definere et display. Indstil intervallet for disse farver for at definere en farve til displayværdien. Dette er Værdien efter Corrector. Bemærk, at hvis du bruger en tilstandstype, vil du måske tildele RØD = Fra 0 til 0, GRØN = Fra 1 til 1 og GUL = Fra 2 til 2. Da en tilstand altid er enten 1 eller 0, vil dette forhindre tvetydig information og forhindrer den GUL farve i at blive brugt. Du kan vælge en hvilken som helst to farver, du kan lide for en tilstandstype.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- set1

Set Analog Input Page
De analoge indgange kan indstilles til at give forskellige udlæsninger ved brug af en række skærmtyper. Ud over at vise inputdataene kan du navngive displayet samt knytte et relæ til det. Dette relæ vil skifte fra grønt til RØD, efterhånden som det går fra on til off samt er klikbart for at styre det.

  1. Analog Input Selected – The Analog Input that you are editing (identified by the line on which you clicked the Edit icon).
  2.  Navn – Du kan indstille et navn på 15 tegn for denne indgang. Dette navn vises i bjælken øverst på skærmen.
  3. Etiket – Indstil en etiket på 7 tegn, som vises på det faktiske aktive display.
  4. Korrektor – Ved at bruge dette felt kan du addere, subtrahere, gange eller dividere en værdi, før værdien vises på displaysiden. Dette er en korrektor med 2 værdier, hvor hver er adskilt af et enkelt mellemrumstegn. (dvs. "+2, -2, *3, /3")
  5. USE – Sets this input to active. Turns the input number indicator to GREEN. It should be noted that when in use the input consumes CPU time and other resources depending on its type. Although all inputs may be active at the same time, it is recommended to turn on only those you want to use.
  6. Type – Inputdataene kan bruges til at beregne en række resultater. Du kan vælge:
    • Analog 1 – Analog 1 input from a SERVER with an input such as found on a R4ADI.
    • Analog 2 – Analog 2 input from a SERVER with an input such as found on a R4ADI.
    • AC Current 1 – AC current sensor 1 input from a SERVER with an input such as found on a R4ADI.
    • AC Current 2 – AC current sensor 2 input from a SERVER with an input such as found on a R4ADI.
    • AC Current 3 – Not used
    • Volts – The measurement of the voltage powering the SERVER.
    • Current – On “S” models, this is the current consumed by the SERVER.
    • Int. Temp – Temperature from the board mounted sensor.
    • Ext. Temp – Temperature from the “S” model SERVER.
    • R. Humidity – % Relative Humidity from the “S” model SERVER.
    • MMA X – The X axis accelerometer data from the “S” model SERVER.
    • MMA Y – The Y axis accelerometer data from the “S” model SERVER.
    • MMA Z – The Z axis accelerometer data from the “S” model SERVER.
  7. Display – Dette valg lader dig ændre den anvendte displaytype. Du kan vælge:
    1. Dot – A single dot with the value in the middle. This can be used for State. You can make a dumb indicator by changing the color of the Dot based on the value. The label is under the Dot.
    2. Values – Displays the Corrected Value with the Label in a box directly below it.
    3. Meter – This Meter has configurable scale based on the Min/Max values and arcs can be colored per the Color ranges. The Label is displayed within the Meter.
    4. VBar – Also based on the Min/Max values for the scale and the bar changes color based on the values in the Color ranges.
  8. Relay – Enter a Relay number here. If it is a local relay it will show Green or RED depending if it is on or off.
    By clicking on it the relay will turn on and off. The name comes from the relay settings page. This may be useful if you want to turn the subject of a display on and off. Any relay can be used on any input and each may be reused for any other input.
  9. Værdi – Disse er Min/Max-værdier, der bruges til displayet. Dette er nyttigt til at forhindre en måler i at gå forbi dens ende eller indstille værdien af ​​en VBar. Dette er Værdien efter Corrector. Systemet kan ikke vise en værdi over Max, så sørg for, at denne som minimum er indstillet til 1.
  10.  Gul/Rød/Grøn – Der er tre farver, der kan bruges til yderligere at definere et display. Indstil intervallet for disse farver for at definere en farve til displayværdien. Dette er Værdien efter Corrector. Bemærk, at hvis du bruger en tilstandstype, vil du måske tildele RØD = Fra 0 til 0, GRØN = Fra 1 til 1 og GUL = Fra 2 til 2. Da en tilstand altid er enten 1 eller 0, vil dette forhindre tvetydig information og forhindrer den GUL farve i at blive brugt. Du kan vælge en hvilken som helst to farver, du kan lide for en tilstandstype.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- set2

Tasks Page
The TASKS page displays the automatic events that can be programmed into the SERVER. You can schedule up to 16 events in the SERVER. These are constructed as IF … THEN statements. In addition, the IF term can have 2 elements (IF a, AND/OR/NOT b … THEN c). This provides a simple to program and powerful way to take advantage of the data acquired by the SERVER. The Tasks page shows you an overview of configured tasks. You can click the dot in the State column to turn a task on or off indicated by a green dot for ON, and a red dot for OFF. To edit or create a task, click the Edit icon to the right of the task line. This will take you to the Set Schedule page detailed in the next section.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- schedules

Set Schedule Page
The SET SCHEDULE page allows you to create time and logic-based events that will occur automatically if the conditions are met.

  1. Schedule Select – Determined by clicking on a schedule line from the previous page.
  2.  Schedule Name – Enter a 15-character Schedule Name.
  3. USE – In order for a Schedule line to be active you must select the USE button. If there is an error detected in entering Schedule data, the USE box will automatically uncheck.
  4. LOG – Vælg log for at dette element skal vises i systemloggen, hver gang det udføres.
  5. Email – Click Email to automatically send an email when this schedule is executed.
  6. Device A – Select Device A for the first term in the IF statement from the drop box.
  7.  Data A – Select Data A for the above device. Depending on the device selected, the Data used for testing may have special properties. See the list below for Data that may be entered. If an error is detected indata entry when the “Save” button is pushed, the USE box will uncheck and the Data box containing the error will be highlighted.
    • Minute – Enter: mm
    • Hour – Enter: hh (use 24-hour system)
    • Day – Enter: dd
    • DayofWeek – Enter: Sunday = 1, Monday = 2, Tuesday = 3, Wednesday = 4, Thursday = 5, Friday = 6, Saturday = 7, Weekday = 8, Weekend = 9
    • Time – Enter: hh:mm (use leading zeros, seconds are ignored) (use 24 hour system) ex:07:30 or 14:05
    • Date – Enter: yy/mm/dd (use leading zeros) ex: 20/01/10 for January 10, 2020
    • Relay – Enter: Relay number and (+ or -), ex: 01+ for Relay 1 ON or 01- for Relay 1 OFF
    • Button – Enter: + or – (for ON or OFF respectively)
    • Flag – Enter: Flag number(opt.+), or Flag number (for ON or OFF respectively)
    • Temp – Enter: >, = or < value; example: >40 (altid grader C)
    • Volts – Enter: >, = or < value; example: <10
    • Analog – Analog input. Enter an input number and >, = or < and value. Example: 3<123 (This value is raw data value prior to any Corrector used by the input display page.)
    • Digital – Digital input. Enter Input Number, Type, >, =, or < and value; example: 1F>7500 (This value is the raw data value prior to any Corrector used on the display page). Type can be (case sensitive):
    • S State (On/Off)
    • C Non-resettable counter
    • c Resettable counter (lower case ‘c’)
    • F Frequency in 1/1000 seconds
    • P Period in 1/1000 seconds
  8. Logik – Opsæt en logisk sammenligning mellem enhed A og enhed B.
    • AND – True if: Device A is true AND Device B is true
    • OR – True if: Device A is true OR Device B is true
    • NOT – True if: Device A is true and Device B is NOT true
  9.  Device B – Select Device B for testing from the drop box.
  10. Data B – Vælg Data B for ovennævnte enhed. Afhængigt af den valgte enhed kan de data, der bruges til testning, have særlige egenskaber. Se ovenstående liste.
  11.  Enhed C – er det, der skal kontrolleres.
  12. Data C – Indstil egenskab for enhed C. Syntaks bruges som følger:
    • RELAY – These are relays on this SERVER. You can set up to four per schedule. Enter separated by commas, for example "1,2,3,4"
    • FLAG – This is a storage flag that can be used to make more complex schedules. There are 8 flags that can be turned on or off.
    • REMOTE – Refers to a remote SERVER unit. When these conditions are met, this SERVER will send a command to control a remote SERVER. The Data field for a remote unit should be in the format,
    “REMOTE UNIT NUMBER, REMOTE UNIT RELAY”. For example, "3,5". Disse eksterne SERVERE skal identificeres på siden Konfigurer/Konfiguration af fjernenhed.
    • COUNTER – Adds count to digital input counter – set as 1 or 2 depending on which digital input is counting
    • BLUE LED – No data.
    • eMAIL – Will send eMail, no data.
    • NOTIFY – Will send notification to Kodalert, set 1- 8 for Settings/Alarm Notification number. (Not Implemented)
  13.  Handling – Hvad skal man gøre med Enhed C. Valgmulighederne er:
    • ON – Turns device ON
    • OFF – Turns device OFF
    • TGL – Toggles state of Device C
    • RESET – Resets CounterR

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Turns device

Logside
The Logs tab displays over 10,000 entries from actions taken by the SERVER or by users themselves. This feature allows several actions for the convenience of displaying and collecting data from the SERVER.

  1. The checkboxes above the date allow the user to filter logs from different sources. To filter out logs you do not wish to see from a certain source simply uncheck the box.
  2. Each log has a reference number and a time and date attached in a “yyyy/mm/dd” and “hh:mm:ss” format. Afterwards is the event displayed.
  3. To scroll through the logs, use the arrows to the right-hand side, where the horizonal line and arrow brings you to the start or end, the double arrow moves up or down a page, and the single arrow moves up or down a single log.
  4. To refresh the logs manually click the REFRESH button below the Log Details.
  5. To download the Log Details, click the DOWNLOAD button below the Log Details, this allows you to save the logs as a separate file.

Bruger- og administratorlegitimationsside
Brug denne side fra rullemenuen Indstillinger. Her kan du oprette op til 3 brugere til dit SERVER-system. Som standard er kun Bruger 1 aktiv. Her kan du:

  1. User Name and Password – Each user has their own credentials. As a default these are set toadmin/admin, user2/user2 and user3/user3 for Users 1, 2 and 3 respectively. The passwords are never displayed. Note: when you reset the password, it must be less than 13-character.
  2. Aktiv – Skal være markeret for at denne bruger kan logge på, du kan ikke deaktivere bruger 1.
  3. Admin – Kun admin kan gemme data på de fleste sider. Dette beskytter din SERVER mod at blive ændret af en uautoriseret person.
  4. Timeout – Ikke aktiveret på nuværende tidspunkt.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Admin

Tid/dato side
Brug denne side fra rullemenuen Indstillinger. Denne side giver dig mulighed for at opsætte klokkeslæt- og datosystemet.

  1. Time – Set time using an hh:mm:ss format.
  2. Dato – Indstil dato ved hjælp af formatet åå/mm/dd.
  3. Time Zone – Set desired time zone 5 for EST, 8 for PST, you can now add a :mm for setting part hour, for example, 5:30 er en tidszone på 5 timer og 30 minutter.
  4. Brug sommertid – Vælg for automatisk at justere dit systemtid på sommertid. (Ikke nøjagtig i alle tidszoner.)
  5. Brug MIL-tid – Vælg for at bruge 24-timers format.
  6. Use NTP Update – Select to synchronize SERVER time with NTP server
  7.  NTP Web Site – Dette er den valgte NTP-server til opdateringer.
  8. NTP-interval – Tidsinterval mellem opdateringer i minutter.
  9.  Log NTP Event – Normally NTP exceptions will be logged, select this option to Log every NTP event. (May be useful in debugging.)

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- logged

Indstillinger side

Access this page from the Settings dropdown menu. Select these settings to enable various features in the SERVER

  1. Use Active Main – No longer used. (Select PAUSE to go inactive.)
  2.  Kræv login – Hvis ikke valgt, tillader SERVEREN al adgang uden legitimationsoplysninger.
  3. Use IP Ranges – Not Implemented.
  4. Use RESTFUL IP Ranges – Not implemented.
  5. Use Remote IP Ranges – Not implemented.
  6. Brug RESTful Authentication – Kræv brugernavn og adgangskode til RESTful.
  7. Udvid relærækkevidde – Aktiverer 8 relæer.
  8. Brug relæradioknapper – Hvis det er indstillet, slukkes alle andre, når et relæ er tændt.
  9. SSL Port No. – Not supported – For future use.
  10.  Brug system-e-mails – Aktiverer yderligere e-mail-beskeder.
  11. Brug Fahrenheit – Vælger Celsius eller Fahrenheit.
  12. PGM Dynamic Relays – Changes properties of relays in task schedule.
  13.  CLR PGMs on Start – Reinitialize tasks on start up.
  14.  RTC Temperature Compensation – All Koda boards can add Temperature and Humidity sensor.
  15.  Brug AM2302 – Brug AM2302 temperatur- og fugtsensor (sælges separat).
  16.  Java Report – Send data to HourCollector app over ethernet (only for IoTMeter)
  17.  Use Metric – Not supported – For future use.
  18.  UART Usage – Enter “Audio” for Netbell-NTG, “Clock” for Netbell clock.
  19.  Switch Bypass (1/2) – Ignores physical inputs if set. For example, in a Koda 200 board, you want to ignore input 1 switch, check Switch Bypass 1
  20.  Setting 19 – Not supported – For future use
  21. Brug lyd File System – Activate SD Card reader for Netbell-NTG
  22.  WiFi Report – Enable data transfer over WiFi (WiFi IoTMeter only)
  23.  Active Landing Page – Not supported – For future use.
  24. . Invert Relay Control – The relay is set to NO by default. By checking this box the relay will be inverted to NC.
  25.  Setting 24 – Not supported – For future use.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Settings Page

Dynamisk DNS-side
Access this page from the Configure dropdown menu. From this page you can assign dynamic DNS settings. This page, along with proper port forwarding through the router, can enable global access to a device behind a NAT router or firewall. You will need to assign a static IP address and port number (see Network Config Page on page 25) and port the IP address on your router (refer to your router’s user manual). An internet IP address will have to be hosted in order to access your SERVER from the internet. Currently the only IP hosting service supported is provided by DynDNS (https://dyn.com)

  1. Brug DDNS – Aktiverer denne tjeneste.
  2. DDNS-tjeneste – Vælg en tjeneste fra drop-boksen. I øjeblikket er den eneste understøttede tjeneste DynDNS
  3.  Brugernavn – Dette refererer til den konto, der er oprettet på DDNS-tjenesten.
  4. Adgangskode – Adgangskode til adgang til DDNS-tjenesten.
  5. Host – This is the IP name registered at the DDNS service for rerouting to this SERVER

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Settings Page1

E-mail opsætningsside
Konfigurer en e-mail-konto, som SERVEREN skal bruge til at sende e-mail-beskeder fra forskellige moduler. Få adgang til denne side fra fanen Konfigurer.
Note: This unit is NOT compatible with SSL/TLS, there are 3rd party SMTP delivery servers which do not require SSL and can be used. For instructions on how to use a 3rd party SMTP delivery service, please refer to Appendix 1 at the end of this manual).

  1. SMTP-server – Indtast den udgående mailserver, du vil bruge.
  2. Port – Dette er porten på den server. Du kan slå din posttjeneste op online for disse oplysninger såvel som de andre opsætningsfelter.
  3. Brug SSL – Lad det være umarkeret, når du bruger 3. parts SMTP-server.
  4. Brugernavn – Dit e-mail-kontonavn.
  5. Adgangskode – Adgangskode til e-mailkonto.
  6. To Address – Enter up to 3 address for this email set up. An addressee, a CC and a BC.
  7.  Emne – Emnelinje i e-mail-headeren.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Email Setup Page

Netværkskonfigurationsside
Access this page from the Configure dropdown menu. This page allows the configuration of the SERVER’s network settings.
FORSIGTIGHED: Incorrect settings may cause the board to lose network connectivity. In order to access a device in your network remotely you must PORT the device. This tells your router that information coming in should be sent to a specific device on your network.

  1. MAC Address – This is a unique MAC address that is assigned to this product at time of assembly. It cannot be altered.
  2. Værtsnavn – Dette er et Netbios-navn, som denne enhed kan adresseres til i nogle netværk. Det kan også vises i din routers leasing-mappe. Det er et nyttigt sted at navngive din SERVER og vises på startsiden og på Discoverer.
  3. Portnummer – Dette bliver en del af IP-adressen og er nødvendigt for internetadgang. Hvis dette ikke er indstillet, vil SERVEREN som standard have et portnummer på 80.
  4. IP Address – Typically you only change the last group of numbers. If you change this IP address make sure to reserve this IP on your router and no other devices are using this IP address or you may not be able to reach this SERVER. If this happens you may need to Restore Defaults using the push button method.
  5.  Gateway – Typisk en router på dit TCP/IP-netværk, der fungerer som et adgangspunkt til din internetudbyder.
  6. Undernetmaske – Et 32-bit tal, der maskerer en IP-adresse og opdeler IP-adressen i netværksadresse og værtsadresse. Bare lad det stå på 255.255.255.0
  7. Primær DNS – En primær DNS.
  8. Sekundær DNS – En sekundær DNS.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Network Configuration Page

IP-områdekonfigurationsside
Access this page from the Configure dropdown menu. Use these security settings to select a range of IP address that will be allowed to access the SERVER.CAUTION: Incorrect settings may cause the board to lose network connectivity. Not implemented on this SERVER.
Side med eksterne enheder
Access this page from the Configure dropdown menu. These settings allow the SERVER to remotely control the relays on another SERVER. This is done by selecting the Remote Device in the Schedule program or by setting up a relay as a REMOTE. There are 8 possible REMOTE locations.
FORSIGTIGHED: Forkerte indstillinger vil få kortet til at miste sine fjernforbindelser.

  1. Enhedsnavn – Indtast et tekstnavn for denne enhed til fremtidig reference.
  2. IP-adresse – IP-adressen på fjernenheden inklusive et portnummer.
  3.  Brugernavn – Bruges i grundlæggende godkendelse.
  4. Password – Used in Basic Authentication.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- remote

Kodalert Page
Not Yet Implemented. Access this page from the Configure dropdown menu. Kodalert provides an interface for alerts of Internet connected devices. Kodalert is a cloud based, open platform monitoring and alert system for the Internet of Things in your physical world. Any Thing that can send an email or TCP messages including our SERVERS, other manufactures devices and people using email can use Kodalert. It can work for multiple remote locations, alert multiple users instantly using the rules you setup by text, email, smart phone Apps push notification or audible alarm instantly when something happens.

  1. Advarselsnummer
  2. Prøve
  3. Bruge
  4.  Herske

In the Alarm Notification page, you can change the state (on/off) of the relay by clicking the green circle in the state column. Push the EDIT icon to change the Alarm’s settings.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- kodalert

Specifikationer

FARGO R8G2

  • 10M/100M RJ45 Internet interface with connection and activity LEDs
  • 8 Relay outputs, 1FORMC 48 Volt Max (24VAC/DC 3A)
  • Status LEDs (pulse, bootloader, and locate)
  • Ethernet Bootloader (for server hardware code upgrade)
  • PoE or 12VDC @500mA (nominal)
  • Web interface w/basic authentication
  • On board temperature sensor and voltagog sensor
    Reset /Locate pushbutton (blue LED)
  • Working Temperature from 0 to +70 Celsius
  • Storage Temperature from 40 to +125 Celsius
  • Humidity from 10% to 80% noncondensing
  • Dimensions 74mm x 100mm x 20mm, mounting holes 64mm x 92mm Ф 3.2mm 4 places
  • Understøttede protokoller: HTTP/SMTP/SNTP

FARGO R4G2

  • 10M/100M RJ45 Internet interface with connection and activity LEDs
  • 4 1FormC relays 48 Volt Max (24VAC/DC 3A)
  • 2 optically isolated digital inputs, 12V 1mA or pulldown switch selectable, 2 conductor screw terminal connectors for each.
  • 2 Analog 0-5VDC Inputs 30mA 3.3VDC power source PTC protected. 3 conductor screw terminal connectors for each (3.3VDC, input, ground) (R4ADI only)
  • 2 Current sensor inputs. 3.5mm stereo jack connector for each (R4ADI only)
  • Status LEDs (pulse, bootloader, and locate)
  • Ethernet Bootloader (for server hardware code upgrade
  • POE or 12VDC @500mA (nominal)
  • Web interface w/basic authentication
  • On board temperature sensor and voltagog sensor
  • Reset/Locate pushbutton
  • Working Temperature from 0 to +70 Celsius
  • Storage Temperature from 40 to +125 Celsius
  • Humidity from 10% to 80% noncondensing
  • Dimensions 74mm x 100mm x 20mm, mounting holes 64mm x 92mm Ф 3.2mm 4 places
  • Understøttede protokoller: HTTP/SMTP/SNTP

KODA100

  • 10M/100M RJ45 Internet interface with connection and activity LEDs
  • 2 1-Form-A relay 48VAC@8A Max
  • 2 optically isolated digital inputs, 12V 1mA or pulldown switch selectable
  • Status LEDs (pulse, bootloader, and locate)
  • Ethernet Bootloader (for server hardware code upgrade)
  • POE or 12VDC @500mA (nominal)
  • Web interface w/basic authentication
  •  On board temperature sensor and voltagog sensor
  • Reset/Locate pushbutton (blue LED)
  • Working temperature from 0 to +70 Celsius
  • Storage temperature from 40 to +125 Celsius
  • Humidity from 10% to 80% noncondensing
  • Mål: 70mm x 100mm x 25mm
  • Understøttede protokoller: HTTP/SMTP/SNTP

KOD200

  • 10M/100M RJ45 Internet interface with connection and activity LEDs
  • 4 1FormA relays 48 Volt Max 1A dry contact or drive 10V ±10% 50mA to external devices
  • 2 optically isolated digital inputs, 12V 1mA or pulldown switch selectable
  • Status LEDs (pulse, bootloader, and locate)
  • Ethernet Bootloader (for server hardware code upgrade)
  • POE or 12VDC @500mA (nominal)
  • Web interface w/basic authentication
  • On board temperature sensor and voltagog sensor
  • Reset/Locate pushbutton (blue LED)
  • Working Temperature from 0 to +70 Celsius
  • Storage Temperature from 40 to +125 Celsius
  • Humidity from 10% to 80% noncondensing
  • Mål: 70mm x 100mm x 25mm
  •  Understøttede protokoller: HTTP/SMTP/SNTP

Board Reference Layout

Fargo R8

  1. 8 Relay outputs, 1FORMC 48 Volt Max (24VAC/DC 3A)
  2. Rj45 stik
  3. Strømstik (12VDC)
  4. Nulstil knap
  5. Find knap

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Layout

Fargo R4

  1. 3.5mm Inputs for AC Current Sensor (R4ADI Only)
  2. Analog Inputs (R4ADI Only)
  3. 4 Relay outputs, 1FORMC 48 Volt Max (24VAC/DC 3A)
  4. Digitale indgange
  5. Digital Input Switches (Input 1 on right.
    Up: Pullup, Down: Isolated)
  6.  Rj45 stik
  7. Nulstil knap
  8. Find knap
  9.  Strømstik (12VDC)

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Sensor

Koda 100

  1. Digital Inputs (#1 on the left) 5VDC-48VDC (12VDC-48VDC must use the external resistor)
  2. Relay Outputs (#1 is on the right) 8A@48VAC Max
  3. Digital Input Switches (IN 1 on left. UP: Isolated, Down: Pullup)
  4. Nulstil knap
  5. Genindlæs knap (tænder blå LED - identificerer på Discoverer)
  6. Rj45 stik
  7. Strømstik (12VDC)
  8. USB-ministik til temperatur-/fugtighedssensor (sælges separat)

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Power Connector

Koda 200

  1. Digital Inputs (#1 on the left) 5VDC-48VDC (12VDC-48VDC must use the external resistor)
  2. Relay Outputs (#1 is on left) 48 Volt Max 1A dry contact or drive 10V ±10% 50mA
  3. Digital Input Switches (IN 1 on left. UP: Isolated, Down: Pullup)
  4.  Relay Switches (Up for dry contact, down for 10V/50mA)
  5. Nulstil knap
  6.  Genindlæs knap (tænder blå LED - identificerer på Discoverer)
  7. Rj45 stik
  8.  Strømstik (12VDC)
  9. USB-ministik til temperatur-/fugtighedssensor (sælges separat)

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Power Connector1

Fabriksindstilling
To perform a factory Reset, push the Reset button. When the green LED turns on, push and hold the Reload button until the flashing red LED turns off and then turns on solid. Refer to Board Reference Layout section for the button locations on your device.

This user-manual supplements the documentation for the following Linortek products:

  • Netbell-2
  • Netbell-8
  • Netbell-K (and variants)
  • iTrixx-NHM

For more information, documentation and how-to videos, visit https://www.linortek.com/downloads/
Dette dokument kan findes på www.linortek.com/downloads/documentations/
Hvis du har brug for hjælp til din enhed, kan du besøge www.linortek.com/technical-support
Linor Technology, Inc.
Oplysninger kan ændres uden varsel.

Bilag 1

Sådan sender du SSL-e-mails ved hjælp af en tredjeparts SMTP-tjeneste til Linortek Fargo og Koda-enheder
Som standard bruger Koda/Fargo-enheder ikke-SSL SMTP-e-mail-servere. Men de fleste e-mail-servere i dag er skiftet til SSL-sikkerhedsprotokol, der er 3. parts SMTP-leveringsservere, som ikke kræver SSL og kan bruges. Der er mange SMTP-e-mail-udbydere på markedet. Vi bruger SMTP2GO som eksample for at demonstrere opsætningsprocessen. SMTP2GO er gratis at bruge med op til 1000 e-mails/måned. For at bruge SMTP2GO, besøg venligst: https://www.smtp2go.com/ .
Trin 1. Opret SMTP2GO-kontoen.
For at oprette en konto skal du blot klikke på "Tilmeld", vælg "1K e-mails" på skalaen og vælg "Gratis plan" (Hvis du har brug for at sende mere end 1000 e-mails om måneden, skal du vælge den plan, der opfylder dine krav).

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Create

For at oprette en konto på SMTP2GO kræves en virksomheds-e-mailadresse. Gratis e-mail-tjenester såsom Gmail eller Yahoo vil ikke lade dig fortsætte. Når du har aktiveret din SMTP2GO-konto, skal du tilføje en bruger.
Trin 2. Tilføj en bruger.
Den bruger, du opretter på SMTP2GO, vil være den udgående e-mail-server, når du konfigurerer Fargo/Koda-enheden til at sende e-mail-rapporter, sørg venligst for, at din virksomheds e-mail-server ikke blokerer e-mails, hvis du bruger gratis e-mail-konto såsom Yahoo eller Gmail til at tilføje en bruger her.
Log ind på din SMTP2GO-konto, vælg "Indstillinger" > "SMTP-brugere" i venstre sidemenu, klik på "Tilføj SMTP-bruger" og udfyld formularen.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- add smtpEfter at brugeren er føjet til din SMTP2GO-konto, vil den vise de oplysninger, du skal bruge for at konfigurere e-mail-meddelelsen på dine Fargo/Koda-enheder.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- add smtp1

Trin 3. Konfigurer Linortek-enheden.
Når du har oprettet en konto og tilføjet en bruger, skal du logge ind på din Linortek-enhed, navigere til Konfigurer – E-mail-opsætningsside for at konfigurere e-mail-besked:

  • SMTP-server – Indtast den udgående mailserver, du vil bruge, det er mail.smtp2go.com i vores eks.ample.
  • Port – Dette er porten på den server. SMTP-porten er 2525 i vores eksample.
  • Brug SSL – Lad det være umarkeret, når du bruger 3. parts SMTP-server.
  • Brugernavn – Brugernavnet fra SMTP2GO, da vi oprettede en bruger i forrige trin.
  • Adgangskode – Brugerens adgangskode fra SMTP2GO, da vi oprettede en bruger i forrige trin.
  • Til adresse – Indtast op til 3 adresser for denne e-mail-opsætning. En adressat, en CC og en BC.
  • Emne – Emnelinje i e-mail-headeren.
    LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Inbox folder

Så snart du trykker på "Gem/Test", sender enheden automatisk test-e-mailen. Tjek venligst mappen Uønsket/Andet for at finde den, hvis den ikke er i mappen Indbakke.
Trin 4. Indstil opgaven til automatiske e-mail-meddelelser.
You should be able to receive email notifications for various events from the Fargo/Koda boards at this point. If you need to receive condition logic notification, you can use our condition logic configuration to setup such report. To setup the logic condition report notification, go to Tasks page on your Fargo/Koda device, click the Edit icon of a Schedule. For details of how to create a logic-based event, please refer to the Set Schedule Page on the Fargo/Koda User Manual, which can be downloaded here:
https://www.linortek.com/download/fargo%20g2_koda%20downloads/fargo%20g2_koda%20documentation/Fargo-G2-and-Koda-User-Manual.pdf
I dette sample Vi vil bruge Network Hour Meter-enheden som en example for, hvordan du modtager e-mail-rapporter hver dag kl. 11:52.

LINORTEK Fargo G2 TCP IP Web Based Relay Controller- Inbox folder1

Så snart alle betingelser for opgaven er opfyldt, får du følgende e-mail:

Hour Reading Report
LINORTEK Fargo G2 TCP IP Web Based Relay Controller- icon support@linortek.com
Mon 4/11/2022 11:52 AM
To: Liyu Nalven
HM 1, my machine, is at 000242.01 hrs.
Reply Forward