COOPER-LOGO

Datgodiwr DMX COOPER CLS Rheolydd Golau DMX

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-PRODUCT

Manylebau

  • Brand: CLS-DMX-DATGODYDD
  • Mewnbwn: 12 – 24VDC
  • Allbwn: 12 – 24VDC
  • Llwyth Uchaf: 4CH x 5A, 4CH x 192W (24V)

Cyfarwyddiadau Defnydd Cynnyrch

Diogelwch a Rhybuddion

  1. Install in accordance with national and local electrical code.
  2. Make sure power is OFF before starting installation or maintenance.
  3. Handle the fixture with care due to sharp edges.
  4. Do not install the fixture in spaces where impacts from objects can occur.

Cyfarwyddiadau Gosod

  1. Diffoddwch y pŵer wrth y torrwr cylched cyn ei osod.
  2. Determine the location to install components by referring to system diagrams.
  3. Pennwch y parthau rheoli yn unol â chanllaw'r system.
  4. Connect the decoder to the DMX controller following the wiring diagram.

RHYBUDD

  • Risg o Dân, Sioc Drydanol, Toriadau neu Beryglon Anafiadau Eraill - Rhaid i drydanwr cymwysedig berfformio gosod a chynnal a chadw'r cynnyrch hwn. Rhaid i'r cynnyrch hwn gael ei osod yn unol â'r cod gosod cymwys gan berson sy'n gyfarwydd ag adeiladu a gweithredu'r cynnyrch a'r peryglon dan sylw.
  • Perygl Sioc Tân a Thrydan - Sicrhewch fod pŵer penodol wedi'i ddiffodd cyn dechrau ei osod neu geisio unrhyw waith cynnal a chadw. Datgysylltwch y pŵer wrth y ffiws neu'r torrwr cylched.
  • Risg o Dân - Dargludyddion cyflenwi o leiaf 90°C.
  • Risg o Llosgi - Datgysylltwch bŵer a gadewch i'r gosodiadau oeri cyn eu trin neu eu gwasanaethu.
  • Risg o Anaf Personol - Oherwydd ymylon miniog, triniwch â gofal.
  • Risg o Anaf Personol - Gosodiad na fwriedir ei osod mewn campfa neu fan arall lle gall effeithiau gwrthrychau ddigwydd.
  • Gall methu â chydymffurfio â'r cyfarwyddiadau hyn arwain at farwolaeth, anaf corfforol difrifol a difrod i eiddo.

YMWADIAD O ATEBOLRWYDD: Nid yw Cooper Lighting Solutions yn cymryd unrhyw gyfrifoldeb am iawndal neu golledion o unrhyw fath a allai ddeillio o osod, trin neu ddefnyddio'r defnydd amhriodol, diofal neu esgeulus hwn.

PWYSIG: Darllenwch yn ofalus cyn gosod gosodiad. Ei gadw er gwybodaeth yn y dyfodol.

HYSBYSIAD: Sgriw tir gwyrdd wedi'i ddarparu mewn lleoliad priodol. Peidiwch ag adleoli.

HYSBYSIAD: Gall gosodiadau gael eu difrodi a/neu fod yn ansefydlog os na chânt eu gosod yn iawn.

Nodyn: Gall manylebau a dimensiynau newid heb rybudd.

SYLW Receiving Department: Note actual fixture description of any shortage neu ddifrod amlwg ar dderbynneb danfon. File hawliad am gludwr cyffredin (LTL) yn uniongyrchol gyda'r cludwr. Rhaid i geisiadau am ddifrod cudd gael eu ffeilio o fewn 15 diwrnod i'w danfon. Rhaid cadw'r holl ddeunydd sydd wedi'i ddifrodi, ynghyd â phacio gwreiddiol.

DIOGELWCH A RHYBUDDION

  1. Gosod yn unol â rheoliadau cod trydanol cenedlaethol a lleol.
  2. Bwriedir i'r cynnyrch hwn gael ei osod a'i wasanaethu gan drydanwr trwyddedig cymwys.
  3. PEIDIWCH â chysylltu'n uniongyrchol â chyfaint ucheltage pŵer.
    Install with a compatible Class 2 constant voltage gyrrwr LED (cyflenwad pŵer).
  4. Mae'r cynnyrch hwn wedi'i raddio ar gyfer gosod dan do ac nid yw wedi'i ddiogelu rhag lleithder.
  5. Install appropriately rated wire between driver,decoder, and fixture. When choosing wire, factor in voltage gollwng, amperage rating, and type (in-wall rated, etc.) Inadequate wire installation may cause fire.
  6. Peidiwch ag addasu neu ddadosod cynnyrch y tu hwnt i gyfarwyddiadau neu bydd gwarant yn ddi-rym.

UCHAFSWM DECODYDD DMX GADWYN DAETH
A maximum of 10x DMX Decoders may be connected together via RJ45 DMX Connection Ports. DMX signal may be extended further by installing a DMX 8-Way Splitter after the 10th DMX Decoder.

MANYLEBAU / MODELAU CYFLYM

  Mewnbwn Allbwn Llwyth Uchaf
CLS-DMX-Decoder 12 – 24VDC 12 – 24VDC 4CH x 5A

4CH x 192W (24V)

  • Cymorth RDM: Ydw
  • Output PWM Frequency: 2KHz
  • DMX Splitter Compatible: Yes
  • Environment: Indoor Location

Troi Pŵer i ffwrdd yn Circuit Breaker

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (1)

Determine Location To Install Components
Cyfeiriwch at y DIAGRAMAU SYSTEM.

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (2)

Determine Control Zones
Determine and group fixtures to be controlled together and one (1) decoder per run is necessary.

Connect Decoder To Dmx Controller.
DMX Decoder to DMX Controller (see diagram above and wiring diagram).

Install Additional Components, Verify
Connections, Turn Main Power On At Breaker.

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (3)

GWEITHREDU

ARDDANGOS SIANEL DECHRAU DMX

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (4)

GOSOD

GOSOD Y CYFEIRIAD DMX

USE THE 3 BUTTONS OF THE DMX START CHANNEL TO ADJUST THE VALUES OF THE DMX ADDRESS. THE DECODER WILL CONTROL UP TO 512 CHANNELS.

  • I osod y cyfeiriad DMX, pwyswch a dal 'botwm 1' am 2 eiliad nes bod y rhifau'n fflachio i'w gweld.
  • Dewiswch gyfeiriad yn seiliedig ar ymarferoldeb y Rheolydd DMX sylfaenol (gweler y canllaw gosod wal / teclyn rheoli o bell). Unwaith y bydd cyfeiriad wedi'i ddewis, bydd y 3 sianel sy'n weddill yn cael eu defnyddio'n ddigidol. Am gynample, if the decoder is addressed to 001 on the display then CH1 – 001, CH2 – 002, СН3 – 003, CН4 – 004. (see diagram on page 5 – System Diagram with DMX Wall Controller)
  • Unwaith y bydd arddangos yn stopio fflachio, cyfeiriad DMX yn cael ei osod.
  • Daliwch 'botwm 1″ am 3 eiliad i gadarnhau'r gosodiad
  • Indicator light will light red when data signal is confirmed

Cooper Lighting Solutions strongly recommends only professional DMX installers utilize the following settings. All standard DMX applications specified by Cooper Lighting Solutions do not require these settings to be adjusted.

GOSOD SIANELAU DMX.
The DMX channels can be adjusted, which allows the user to conserve DMX addresses that may be wasted when programming a large DMX universe!
The factory default is 4 channels and is most commonly used: 4 channels (address 001 – 004) as highlighted in the chart below.

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (5)

I newid gosodiad sianel:

  • Press and hold ‘button 2 and 3’ simultaneously for 2 seconds until ‘cH’ flashes on display (Fig. 2).
  • Pwyswch 'botwm 1' i ddewis allbynnau 1, 2, 3, neu 4 sianel (Ffig. 3).
  • Pwyswch a dal unrhyw fotwm am >2 eiliad i osod allbwn sianel.
  • Daliwch 'botwm 1' am 3 eiliad i gadarnhau'r gosodiad

AMRYWIAETH PWM
Yr amledd PWM diofyn yw PF2 (2KHz)

GOSOD GWERTH GAMMA CURVE PYGU
The dimming curve gamma value can be adjusted for special applications. Default dimming curve is g1.0 (Gamma 1.0)

I newid gosodiad sianel:

  • Press and hold ‘buttons 1, 2, and 3’ simultaneously for 3 seconds until ‘g1.0’ flashes on display (Fig. 5).
  • Pwyswch 'botwm 2' a 'botwm 3' i newid gwerth gama.
  • Daliwch 'botwm 1' am 3 eiliad i gadarnhau'r gosodiad

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (6)

DIAGRAM SYSTEM

Darperir y diagram canlynol fel example system design. Shielded CAT (RJ45 connections) data cables are the most cost-effective solution for transmitting DMX-512 signals. Shielded XLR-3 cables are recommended for minimal EMI and require an additional adapter for connecting to DMX decoders.

Nodyn: Shielded cables with RJ45 connections are provided by others.

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (7)

HYDAU RHEDEG MWYAF

MMG Hyd Rhedeg Uchaf y Goleuadau
STD Gyrrwr ND Gyrrwr
W/ft 90W 60W 96W 60W
03W 30 troedfedd 20 troedfedd 32 troedfedd 20 troedfedd
05W 18 troedfedd 12 troedfedd 19 troedfedd 12 troedfedd
06W 14 troedfedd 9 troedfedd
08W 11 troedfedd 7 troedfedd 12 troedfedd 7 troedfedd

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (8)

** Gosod cyfrol cyson Dosbarth 2 cydnawstage driver. It is recommended to load the driver no more than 80% its labeled rating for maximum longevity.
‡ Refer to driver specifications for a compatible junction box

TRWYTHU

Symptomau Achos Cyffredin
Gosodiad yn ymateb yn anghywir a/neu fflachio •   Incorrect wiring. Reversing Data + and Data -will cause lights to flicker.

•   Ensure compatible constant voltage gyrrwr wedi'i osod.

•   Check connections of additional components.

Methu newid cyfeiriad DMX •   Hold in button ‘0-5’ for 3 seconds until display flashes continuously, then set address and confirm setting.

UCHAFSWM DECODYDD DMX GADWYN DAETH

A maximum of 10x DMX Decoders may be connected together via RJ45 DMX Connection Ports. DMX signal may be extended further by installing a DMX Splitter after the 10th DMX Decoder.
Consult factory for components.

VOLTAGE SIARTIAU GALWEDIG

Ar gyfer y perfformiad gorau a'r allbwn lumen, sicrhewch fod y mesurydd gwifren cywir wedi'i osod i wneud iawn am gyftage gostyngiad o isel voltage cylchedau.

Example: 24V Cyftage Drop & Wire Length Chart

COOPER-CLS-DMX-Decoder-DMX-Light-Controller-FIG- (9)

24V Cyftage Drop & Wire Length Chart

Gwifren Mesurydd 10 Gw

.42 A.

20 Gw

.83 A.

30 Gw

1.3 A

40 Gw

1.7 A

50 Gw

2.1 A

60 Gw

2.5 A

70 Gw

2.9 A

80 Gw

3.3 A

100 Gw

4. 2 A

18 AWG 134 tr. 68 tr. 45 tr. 33 tr. 27 tr. 22 tr. 19 tr. 17 tr. 14 tr.
16 AWG 215 tr. 109 tr. 72 tr. 54 tr. 43 tr. 36 tr. 31 tr. 27 tr. 22 tr.
14 AWG 345 tr. 174 tr. 115 tr. 86 tr. 69 tr. 57 tr. 49 tr. 43 tr. 36 tr.
12 AWG 539 tr. 272 tr. 181 tr. 135 tr. 108 tr. 90 tr. 77 tr. 68 tr. 56 tr.
10 AWG 784 tr. 397 tr. 263 tr. 197 tr. 158 tr. 131 tr. 112 tr. 98 tr. 82 tr.

GWELER CLS-DMX-DECODER - TAFLEN MANYLEB DECODYDD 4-SIANEL DMX
Ar gyfer manylebau llawn.

Gwarantau a Chyfyngiad Atebolrwydd
Cyfeiriwch at www.cooperlighting.com/Warranty am ein telerau ac amodau.

Datganiad Cyngor Sir y Fflint

Mae'r ddyfais hon yn cydymffurfio â Rhan 15 o Reolau Cyngor Sir y Fflint.

Mae gweithrediad yn amodol ar y ddau amod canlynol:

  1. Efallai na fydd y ddyfais hon yn achosi ymyrraeth niweidiol.
  2. Rhaid i'r ddyfais hon dderbyn unrhyw ymyrraeth a dderbynnir, gan gynnwys ymyrraeth a allai achosi gweithrediad annymunol.
    Nodyn: Nid yw'r grantî yn gyfrifol am unrhyw newidiadau neu addasiadau nad ydynt wedi'u cymeradwyo'n benodol gan y parti sy'n gyfrifol am gydymffurfio. Gallai addasiadau o'r fath ddirymu awdurdod y defnyddiwr i weithredu'r offer.
    Nodyn: The equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off an on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Ailgyfeirio neu adleoli'r antena sy'n derbyn.
  • Cynyddu'r gwahaniad rhwng yr offer a'r derbynnydd.
  • Cysylltwch yr offer ag allfa ar gylched sy'n wahanol i'r un y mae'r derbynnydd wedi'i gysylltu ag ef.
  • Cysylltwch â'r deliwr neu dechnegydd radio/teledu profiadol am gymorth.

Mae'r ddyfais hon yn cydymffurfio â therfynau amlygiad ymbelydredd Cyngor Sir y Fflint a osodwyd ar gyfer amgylchedd heb ei reoli. Rhaid gosod a defnyddio'r offer hwn yn unol â'r cyfarwyddiadau a ddarperir a rhaid gosod yr antena(au) a ddefnyddir ar gyfer y trosglwyddydd hwn i ddarparu pellter gwahanu o 20 cm o leiaf oddi wrth bawb.

Datrysiadau Goleuadau Cooper
18001 East Colfax Ave

Aurora, CO 80011
1-800-760-1317
www.cooperlighting.com

Ar gyfer gwasanaeth neu gymorth technegol:
1-800-553-3879

Gwerthiant Canada
281 Ffordd Hillmount
Markham, ON L6C 253
1-800-863-1354

© 2023 Datrysiadau Goleuadau Cooper

Cedwir Pob Hawl
Product availability, specifications,and compliances are subject to change without notice.

FAQ

C: Beth ddylwn i ei wneud os byddaf yn sylwi ar unrhyw fyrdertage neu ddifrod wrth ddanfon?
A: Note the description of any shortage or noticeable damage on the delivery receipt and file a claim with the carrier. Claims for concealed damage must be filed o fewn 15 diwrnod i'w ddanfon.

C: A ellir ymestyn y signal DMX ymhellach o'r porthladdoedd cysylltiad RJ45 DMX?
A: Yes, the DMX signal may be extended further from the RJ45 DMX connection ports.

C: A yw'r dadgodwr DMX yn gydnaws â holltwyr DMX?
A: Yes, the DMX decoder is compatible with DMX splitters.

Dogfennau / Adnoddau

Datgodiwr DMX COOPER CLS Rheolydd Golau DMX [pdfCanllaw Gosod
Datgodiwr DMX CLS Rheolydd Golau DMX, Datgodiwr Rheolydd Golau DMX, Rheolydd Golau DMX, Rheolydd Golau

Cyfeiriadau

Gadael sylw

Ni fydd eich cyfeiriad e-bost yn cael ei gyhoeddi. Mae meysydd gofynnol wedi'u marcio *