GENIE KP2 Universal Intellicode faifan

GENIE KP2 Universal Intellicode faifan

GARGADI

Alama GARGADI

Alamomi

MULKIN KOFAR ZAI IYA KAWO MUMMUNAR RAUNI KO MUTUWA.
  • KADA KA shigar da mai aikawa (faifan maɓalli) sai dai idan na'urar tsaron ma'aikacin ƙofar tana aiki kamar yadda jagorar mai ƙofar ke buƙata.
  • Bangon Console dole ne a saka shi a gaban kofa, aƙalla ƙafa 5 sama da bene da kuma share sassan kofa masu motsi.
  • Ka kiyaye mutane daga buɗewa yayin da ƙofar ke motsawa.
  • KADA KA BAR yara suyi wasa tare da mai watsawa ko mai aiki ƙofar.
    Idan juyawa lafiya baya aiki yadda yakamata:
  • Rufe ƙofar sannan cire haɗin mabudin ta amfani da hannun sakin littafin.
  • KADA KA yi amfani da watsawa ko afaretan kofa.
  • Duba littafin Manufofin Mai Door da Ƙofafi kafin ƙoƙarin yin gyara.

KA SAN KAFIN KA FARA

  • ‘Opener’ refers to the device mounted on the ceiling or wall near the garage door’s spring bar.
  • Complete programming before mounting keypad.
  • Keypad remains lit and active for 15 seconds after a successful PIN entry. Any button press will activate the opener during this time.
  • Press the 7 & 9 keys at the same time to immediately end a sequence and turn the backlighting off.
  • Model GK2-R holds 3 PINs total. Model GK2-P holds 6 PINs total.

PIN SHIRIN ZUWA BUDE

  1. Remove battery tab from battery compartment.
  2. ON OPENER: Find button pad to begin programming mode.
    • If you have a program (PRGM) or SET button (1), press and hold down until the LED turns blue, then release. The purple LED begins flashing.
    • If you have a LEARN CODE button (2), press and hold down until the red LED begins flashing, then release.
      NOTE: Programming window times out at 30 seconds.
      Program Pin To Opener
  3. ON KEYPAD: Press and hold (STAR key) until green LED lights (@ 5 sec or less), then release. LED begins flashing.
  4. ON KEYPAD: Enter desired PIN (3-8 digits) and, with keypad at arms length away from opener, press UP/DOWN key once every two seconds until the opener operates. (Program window ends 15 seconds after last button press).
  5. Once backlighting turns OFF, TEST your PIN to complete setup.
    • Programming a single garage door opener is complete. For additional openers, repeat above steps for each.

BABBAN AIKI

  1. Enter current PIN of selected door.
  2. Press and release UP/DOWN key. Opener will operate.

HAWAN KYAUTA

Keypad MUST be mounted within sight of the garage door (s) at least 5 feet above floor and clear of any moving door parts.

  1. Cire murfin batir da batura.
    Mounting The Keypad
  2. Haƙa rami matukin jirgi 3/32 ”don saman dunƙule.
  3. Shigar da dunƙule cikin ramin matukin jirgi, yana barin rata 1/8 ”tsakanin kan dunƙule da bango.
  4. Maƙala dutsen da aka rataye a bayan faifan maɓalli akan dunƙulewa.
    Mounting The Keypad
  5. Alama da haƙa rami matukin jirgi 3/32 ”don dunƙule ƙasa da amintaccen faifan maɓalli ga bango. (Kada a yi takura sosai).
  6. Sake shigar da batura.
    Mounting The Keypad

KARIN SIFFOFI & TSIRAI

Canja PIN ɗin da ke akwai:

  1. Enter current PIN of selected door.
  2. Press and hold (STAR key) until red LED flashes (@ 5 sec), then release.
  3. Enter NEW PIN for selected door (3-8 digits).
  4. Press and release (STAR key) one time. LED flashes two times to confirm.
    • PIN has been changed and previous PIN will no longer operate the opener.

Saita PIN na ɗan lokaci:

  1. Enter current PIN of selected door.
  2. Press and hold the (STAR key) until green LED turns SOLID (@ 10 sec), then release.
  3. Enter TEMPORARY PIN (3-8 digits).
  4. Press and release (STAR key) one time. LED flashes two times to confirm.
    • Temporary PIN is active until the existing PIN is used again.

Share PIN guda ɗaya a lokaci guda:

  1. Press and hold (STAR key) until red LED flashes (@ 10 sec), then release.
  2. Enter the PIN you want to delete.
  3. Press and release (STAR key) one time. LED flashes two times to confirm.
    • This PIN has been cleared from the keypad.

Share duk PINS da saituna:

  1. Press and hold (STAR key) until red LED turns SOLID (@ 20 sec), then release. LED flashes two times to confirm.
    • Keypad is reset to factory default.

1-Maɓallin rufewa:

This feature works on openers made July 2025 or later. If UP/DOWN key is pressed when keypad backlights are off, any door that is not already at its down limit WILL CLOSE. Default setting is ON.

To turn feature ON/OFF for ALL doors, repeat this process:

  1. Press and hold the 1 & 9 keys at the same time until the blue LED flashes.
    • If the LED flashes 4 times, the feature is off.
    • If the LED flashes 2 times, the feature is on.

To turn ON/OFF BY PIN, repeat this process:

  1. Enter PIN, then press and release (STAR key) two times.
    • If the LED flashes 4 times, the feature is off.
    • If the LED flashes 2 times, the feature is on.

Siffar kullewa:

After 10 wrong PIN attempts in a row, the keypad locks for 5 minutes. To restore function, wait 5 minutes or remove and reinsert the batteries. Default setting is OFF.

To turn ON/OFF, repeat this process:

  1. Enter valid (non-temporary) PIN, then press and release the (STAR key) one time. Press and hold the 5 & 9 keys at the same time until blue LED flashes, then release.
    • If the LED flashes 4 times, the feature is off.
    • If the LED flashes 2 times, the feature is on.

KARANCIN BATIRI/MAYAR DA BATIRI

A single red LED (or no backlighting) indicates batteries need to be replaced.
Shirye-shiryen ba za a rasa ba yayin canjin baturi.

  • Remove (2) AAA batteries and replace with new batteries of same type.
    Check for proper direction of (+) and (-) terminals. Rechargeable batteries are NOT recommended.
  • Change batteries on a yearly basis for best performance.
    Low Battery/battery Replacement

Yi amfani da batura masu inganci. Kar a haxa tsofaffi da sababbin batura. Kada a haɗa alkaline, daidaitaccen (carbon-zinc), ko batura masu caji (nickel-acmium).

Bayanin FCC/IC

This equipment contains licence-exempt transmitter(s)/receiver(s) that comply with Part 15 of the FCC Rules, ICES-003 Class B specifications, and ISED Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. wannan na'urar bazai haifar da tsangwama mai cutarwa ba, kuma.
  2. dole ne wannan na'urar ta karɓi duk wani tsangwama da aka samu, gami da tsangwama wanda zai iya haifar da aiki maras so.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment complies with the RF exposure limits established by the FCC and ISED for an uncontrolled environment. Compliance with SAR requirements has been demonstrated through calculations, confirming that the RF exposure remains below the applicable threshold for use with 0 mm separation from the body.

GOYON BAYAN KWASTOM

faifan maɓalli na Intellicode®

Don taimako, tuntuɓi ta waya ko website
Taɗi: 1-800-354-3643
www.geniecompany.com

©2025 Kamfanin Genie
One Door Drive, Mt. Hope, OH 44660, USA
1-year warranty, visit www.geniecompany.com don cikakkun bayanai.
Pat www.geniecompany.com

Logo

Takardu / Albarkatu

GENIE KP2 Universal Intellicode faifan [pdf] Littafin Mai shi
KP2, KP2 Universal Intellicode Keypad, Universal Intellicode Keypad, Intellicode Keypad, Keypad

Magana

Bar sharhi

Ba za a buga adireshin imel ɗin ku ba. Ana yiwa filayen da ake buƙata alama *