Isishwankathelo soTshintsho
Olu papasho luqulathe olu lwazi lulandelayo olutsha okanye oluhlaziyiweyo. Olu luhlu lubandakanya uhlaziyo olubambekayo kuphela kwaye alujoliswanga ukubonisa lonke utshintsho. Iinguqulelo eziguquliweyo azisoloko zifumaneka kuhlaziyo ngalunye.
Umxholo | Iphepha |
itemplate ehlaziyiweyo | Ngalo lonke ixesha |
Okusingqongileyo okuHlaziyiweyo kunye nendawo ebiyelweyo | 2 |
Uqwalaselo oluhlaziyiweyo | 3 |
Kongezwe isilawuli se-Micro870 kwi-Overview | 4 |
IiNgcaciso zokuSingqongileyo eziHlaziyiweyo | 9 |
Izatifikethi ezihlaziyiweyo | 9 |
Indalo kunye neNdawo
QAPHELA: Esi sixhobo senzelwe ukusetyenziswa kwindawo yemveliso yePollution Degree 2, kwi-overvoltage Uluhlu lwezicelo ze-II (njengoko kuchaziwe kwi-EN / IEC 60664-1), kwiindawo eziphakamileyo ukuya kwi-2000 m (6562 ft) ngaphandle kokunciphisa. Esi sixhobo asenzelwanga ukusetyenziswa kwindawo yokuhlala kwaye asinakubonelela ngokhuseleko olululo kwiinkonzo zonxibelelwano lukanomathotholo kwiindawo ezinjalo. Esi sixhobo sinikezelwa njengezixhobo ezivulekileyo zokusetyenziswa ngaphakathi. Kufuneka ixhonywe ngaphakathi kwendawo ebiyelweyo eyilelwe ngokufanelekileyo ezo meko zokusingqongileyo ezikhethekileyo eziya kubakho kwaye ziyilelwe ngokufanelekileyo ukuthintela ukwenzakala komntu ngenxa yokufikeleleka kwiindawo eziphilayo. Indawo ebiyelweyo kufuneka ibe neendawo ezifanelekileyo zokunqanda amadangatye ukuthintela okanye ukunciphisa ukusasazeka kwedangatye, ukuthobela umlinganiselo wokusasazeka komlilo we-5VA okanye uvunyiwe kwisicelo ukuba awukho ngentsimbi. Ingaphakathi le-enclosure kufuneka ifikeleleke kuphela ngokusetyenziswa kwesixhobo. Amacandelo alandelayo olu papasho anokuthi aqulathe ulwazi oluthe kratya malunga nohlobo oluthile lokulinganisa olufunekayo ukuthobela iziqinisekiso ezithile zokhuseleko lwemveliso.
Ukongeza kolu papasho, bona oku kulandelayo:
- I-Industrial Automation Wiring and Grounding Guidelines, ukupapashwa kwe-1770-4.1, ngakumbi
iimfuno zofakelo. - Umgangatho we-NEMA we-250 kunye ne-EN/IEC 60529, njengoko kufanelekile, kwiinkcazo zeedigri zokukhusela ezibonelelwa ngee-enclosures.
Thintela ukukhutshwa kwe-Electrostatic

- Chukumisa into esekelwe phantsi ukuze ukhuphe into engatshintshiyo.
- Nxiba umtya osezantsi ovunyiweyo.
- Musa ukubamba izihlanganisi okanye izikhonkwane kwiibhodi zamacandelo.
- Musa ukubamba amacandelo esekethe ngaphakathi kwesixhobo.
- Sebenzisa indawo yokusebenza emileyo-ekhuselekileyo, ukuba ikhona.
- Gcina izixhobo kwipakethe efanelekileyo engatshintshiyo xa ingasetyenziswa
Imvume yaseMntla Melika yendawo enobungozi
Olu lwazi lulandelayo lusebenza xa usebenzisa esi sixhobo kwiindawo eziyingozi:
Iimveliso eziphawulwe "CL I, DIV 2, GP A, B, C, D" zifanelekile ukusetyenziswa kwiKlasi I Division 2 Amaqela A, B, C, D, Iindawo ezinobungozi kunye neendawo ezingenabungozi kuphela. Imveliso nganye ineziphawulo kwi-nameplate yokukala ebonisa ikhowudi yobushushu bendawo enobungozi. Xa udibanisa iimveliso ngaphakathi kwenkqubo, ikhowudi yeqondo lokushisa elibi kakhulu (inombolo ephantsi "i-T") ingasetyenziselwa ukukunceda ukucacisa ikhowudi yeqondo lokushisa jikelele. Ukudityaniswa kwezixhobo kwisixokelelwano sakho kuxhomekeke kuphando nguGunyaziwe wengingqi Onolawulo ngexesha lofakelo.
ISILUMKISO: INGOZI YODUMBO
- Musa ukuqhawula izixhobo ngaphandle kokuba umbane ususiwe okanye indawo yaziwa njengengenabungozi.
Musa ukuqhawula uqhagamshelo kwesi sixhobo ngaphandle kokuba umbane ususiwe okanye indawo yaziwa njengengenabungozi. Khusela naluphi na uqhagamshelo lwangaphandle oludibana nesi sixhobo ngokusebenzisa izikrufu, iiletshi zokutyibilika, izihlanganisi ezinemisonto, okanye ezinye iindlela ezibonelelwe ngale mveliso. - Ukutshintshwa kwamacandelo kunokuphazamisa ukufaneleka kweKlasi I, iCandelo 2.
QAPHELA
- Le mveliso isekelwe kwi-DIN kaloliwe ukuya kumhlaba we-chassis. Sebenzisa i-zinc-plated chromatepassivated steel DIN kaloliwe ukuqinisekisa umgangatho ofanelekileyo. Ukusetyenziswa kwezinye izixhobo zikaloliwe zeDIN (umzekeloample, i-aluminiyam okanye iplastiki) ezinokugqwesa, i-oxidize, okanye i-conductors engalunganga, inokubangela ukumisa okungafanelekanga okanye okwethutyana. Khusela isiporo se-DIN kwindawo yokunyusela malunga ne-200 mm nganye (7.8 in.) kwaye usebenzise iiankile zokuphela ngokufanelekileyo. Qinisekisa ukuba umisa isiporo seDIN ngokufanelekileyo. Bhekisela kwi-Industrial Automation Wiring kunye neziKhokelo zokuGcisa, ukupapashwa kweRockwell Automation 1770-4.1, ngolwazi olungakumbi.
Ukuthobela izithintelo ze-UL, esi sixhobo kufuneka sinikwe amandla ukusuka kumthombo ohambelana noku kulandelayo: Udidi 2 okanye iVol encincitage/Yangoku. - Ukuthobela i-CE Low Voltage Directive (LVD), yonke i-I/O edityanisiweyo kufuneka inikwe amandla ukusuka kumthombo ohambelana noku kulandelayo: Ukhuseleko oloNgezelelweyo lweVoltage (SELV) okanye iVol eKhuselweyo ePhantsi kakhulutage (PELV).
- Ukungaphumeleli ukudibanisa imodyuli ye-terminator yebhasi ukuya kwimodyuli yokugqibela yokwandisa i-I / O kuya kubangela umlawuli onzima.
- Musa ukufakela ii-conductors ezingaphezu kwe-2 kuyo nayiphi na i-terminal
ISILUMKISO
- Xa uqhagamshela okanye uqhawula iBhlokhi yeSitena esiSukayo (RTB) usebenzisa umbane wecala lentsimi, i-arc yombane inokwenzeka. Oku kunokubangela ugqabhuko-dubulo kwindawo enobungozi kufakelo. Qinisekisa ukuba umbane ususiwe okanye indawo ayinabungozi phambi kokuba uqhubeke.
- Ukuba uqhagamshela okanye uqhawula iingcingo ngelixa umbane wecala lentsimi uvuliwe, i-arc yombane ingenzeka. Oku kunokubangela uqhushumbo kufakelo oluyingozi kwindawo. Qinisekisa ukuba umbane ususiwe okanye indawo ayinabungozi phambi kokuba uqhubeke.
- Ukuba ufaka okanye ususa imodyuli ngelixa amandla e-backplane evuliwe, i-arc yombane ingenzeka. Oku kunokubangela uqhushumbo kufakelo oluyingozi kwindawo. Imodyuli ayixhasi "Ukususwa kunye nokufakwa phantsi kwamandla" (RIUP) amandla. Musa ukudibanisa okanye ukukhupha imodyuli ngelixa kusetyenziswa amandla. Qinisekisa ukuba amandla asusiwe phambi kokuba uqhubeke.
- Musa ukukhulula i-RTB yokubamba izikrufu kwaye ususe i-RTB ngelixa umbane uvuliwe. Oku kunokubangela uqhushumbo kufakelo oluyingozi kwindawo. Qinisekisa ukuba amandla asusiwe phambi kokuba uqhubeke.
- Musa ukudibanisa ngqo kumgca voltage. Umgca voltagkufuneka ibonelelwe ngesiguquli sokwahlula esifanelekileyo, esivunyiweyo okanye unikezelo lombane olunomthamo wesekethe emfutshane ongagqithiyo kwi-100 VA ubuninzi okanye obulingana nalo.
- Xa isetyenziswe kwiKlasi yoku-I, iCandelo 2, indawo enobungozi, esi sixhobo kufuneka sifakwe kwi-enclosure efanelekileyo kunye nendlela yocingo efanelekileyo ehambelana neekhowudi zombane ezilawulayo.
Izibonelelo ezongezelelweyo
Umthombo | Inkcazo |
I-Micro830, i-Micro850, kunye ne-Micro870 ye-Programmable Controllers Manual User, ushicilelo 2080-UM002 | Inkcazo eneenkcukacha ngakumbi yendlela yokufaka nokusebenzisa iMicro830, iMicro850, kunye neMicro870 abalawuli abanokucwangciswa. |
Imiyalelo yokuFakelo lwe-Micro800 ye-Bus Terminator, ukupapashwa kwe-2085-IN002 | Ulwazi ngokufakela imodyuli yesimisi sebhasi. |
I-Industrial Automation Wiring and Grounding Guidelines, ukupapashwa kwe-1770-4.1 | Ulwazi oluthe kratya malunga ne-wiring efanelekileyo kunye nobuchule bomhlaba. |
Ngaphezuluview
Ukwandiswa kwe-Micro800™ i-I/O yimodyuli ye-I/O encedisayo kwaye yandisa amandla e-Micro850® kunye ne-Micro870® abalawuli. Ezi modyuli zolwandiso lwe-I/O lujongana nabalawuli abasebenzisa i-I/O yokwandisa izibuko.
Imodyuli Ngaphezuluview
Ngaphambili view
Ngaphambili view
Ekunene phezulu view
2085-IF8, 2085-IF8K
Ngaphambili view
Ekunene phezulu view
Inkcazo yemodyuli
Inkcazo | Inkcazo | ||
1 | Umngxunya we-screw onyukayo / unyawo lokunyuka | 4 | Ilatshi yoqhagamshelo lwemodyuli |
2 | Ibhlokhi yesiGaba esisuswayo (RTB) | 5 | Ilatshi yokufaka i-DIN kaloliwe |
3 | I-RTB yokubamba izikrufu | 6 | I/O isalathisi sesimo |

Nyusa iModyuli
Ukufumana ulwazi oluthe kratya malunga nezikhokelo ezifanelekileyo zokumisa, bona i-Industrial Automation Wiring kunye ne-Grounding
Izikhokelo, ukupapashwa kwe-1770-4.1.
iSithuba kwimodyuli
Gcina isithuba kwizinto ezifana neendonga ezivaliweyo, iintambo zocingo, kunye nezixhobo ezikufutshane. Vumela 50.8 mm (2 ngaphakathi.)
indawo kumacala onke ukuze kubekho umoya owaneleyo, njengoko kubonisiwe.
Ukunyuka kwemilinganiselo kunye ne-DIN kaloliwe yokunyuka
Imilinganiselo yokunyuka ayibandakanyi iinyawo zokukhwela okanye iiletshi zikaloliwe zeDIN.
Ukunyuka kwe-DIN Rail
Imodyuli inokunyuswa ngokusebenzisa iileyili ze-DIN ezilandelayo: 35 x 7.5 x 1 mm (EN 50022 - 35 x 7.5).
Kwiindawo ezingqongileyo ezinokungcangcazela okukhulu kunye neenkxalabo zokothuka, sebenzisa indlela yokunyusela ipaneli, endaweni yokunyuswa kukaloliwe weDIN.
Ngaphambi kokuba unyuse imodyuli kumzila we-DIN, sebenzisa i-screwdriver e-flat-blade kwi-latch ye-DIN kaloliwe kwaye uyikrole ezantsi de ibe kwindawo engafakwanga.
- Huka umphezulu wendawo yokunyusela kaloliwe ye-DIN yesilawuli kwi-DIN kaloliwe, kwaye emva koko ucinezele ezantsi de isilawuli sichwechwele kwisiporo seDIN.
- Tyhiliza iletshi kaloliwe ye-DIN ibuyele kwindawo eqhotyoshelweyo.
Sebenzisa i-DIN ii-ankile zokuphela komzila kaloliwe (i-Allen-Bradley® inxalenye yenombolo 1492-EA35 okanye 1492-EAHJ35) ukwenzela ukungcangcazela okanye ukothuka kwemekobume.
Ukunyuka kwePaneli
Indlela yokunyusa ekhethwayo kukusebenzisa iiM4 ezimbini (#8) kwimodyuli nganye. Ukunyamezela isithuba semingxuma: ± 0.4 mm (0.016 kwi.).
Ukunyuka kwemilinganiselo, jonga iMicro830®, Micro850, kunye neMicro870 Programmable Controllers Manual User Manual, ushicilelo 2080-UM002.
Landela la manyathelo ukufaka imodyuli yakho usebenzisa izikrufu zokunyusela.
- Beka imodyuli ecaleni komlawuli ngokuchasene nendawo yolawulo apho uyixhoma khona. Qinisekisa ukuba isilawuli kunye nemodyuli zibekwe ngokufanelekileyo.
- Phawula imingxuma yokugrumba kwimingxunya yescrew yokunyuka kunye neenyawo ezinyukayo uze ususe imodyuli.
- Gqoka imingxuma kwiimpawu, emva koko ubuyisele imodyuli kwaye uyifake. Shiya umtya wenkunkuma okhuselayo endaweni de ube ugqibile ukufaka iintambo kwimodyuli kunye naziphi na ezinye izixhobo.
INdibano yeNkqubo
Imodyuli ye-Micro800 yokwandiswa kwe-I / O iqhotyoshelwe kumlawuli okanye enye imodyuli ye-I / O ngokusebenzisa i-latches edibeneyo kunye neekhonkco, kunye ne-connector yebhasi. Umlawuli kunye neemodyuli ze-I / O zokwandisa kufuneka zipheliswe nge-modyuli ye-2085-ECR ye-Bus Terminator. Qinisekisa ukutshixa iiletshi zoqhagamshelo lwemodyuli kwaye uqinise i-RTB ubambe izikrufu phambi kokufaka amandla kwimodyuli.
Ukufakwa kwemodyuli ye-2085-ECR, jonga iMicro800 Bus Terminator Installation Instructions, ushicilelo 2085-IN002.
Udibaniso lweeNcingo zeNdawo
Kwiinkqubo zolawulo oluluqilima, ukumisa umhlaba kunye nendlela yocingo kunceda ukunciphisa imiphumo yengxolo ngenxa yokuphazamiseka kwe-electromagnetic interference (EMI).
Ucingo lweModyuli
Ibandakanyiwe kunye ne-2085-IF4 yakho, i-2085-OF4, okanye i-2085-OF4K imodyuli yi-12-pin enye yeebhloko ze-Terminal Removable (RTB). Ibandakanywe nemodyuli yakho ye-2085-IF8 okanye i-2085-IF8K zimbini ze-12-pin RTB. Ucingo olusisiseko lwemodyuli yakho luboniswe ngezantsi.
Ucingo olusisiseko kwiModyuli
2085-OF4, 2085-OF4K
2085-IF8, 2085-IF8K
Iinkcukacha
Iinkcukacha ngokuBanzi
Uphawu lophawu | 2085-IF4 | 2085-OF4, 2085-OF4K | 2085-IF8, 2085-IF8K |
Inani le-I/O | 4 | 8 | |
Imilinganiselo HxWxD | 28 x 90 x 87 mm (1.1 x 3.54 x 3.42 kwi.) | 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 ngaphakathi.) | |
Ubunzima bokuthumela, malunga. | 140 g (4.93 oz) | 200 g (7.05 oz) | 270 g (9.52 oz) |
Umzobo webhasi ngoku, max | 5V DC, 100 mA24V DC, 50 mA | 5V DC, 160 mA24V DC, 120 mA | 5V DC, 110 mA24V DC, 50 mA |
Ubungakanani bocingo | |||
Udidi lweeNcingo (1) | I-2 - kwiizibuko zemiqondiso | ||
Uhlobo locingo | Ikhuselwe | ||
I-torque ye-Screw yetheminali | 0.5…0.6 N•m (4.4…5.3 lb•in)(2) | ||
Ukutshatyalaliswa kwamandla, ngokupheleleyo | 1.7 W | 3.7 W | 1.75 W |
Ukalisho lohlobo lwesivalo | Akukho (isimbo esivulekileyo) | ||
Iimpawu zobume | 1 isalathisi sempilo eluhlaza 4 isalathisi sempazamo ebomvu | 1 isalathisi sempilo eluhlaza | 1 isalathisi sempilo eluhlaza 8 izibonakaliso zempazamo ezibomvu |
Ukuzahlula voltage | I-50V (eqhubekayo), Uhlobo lwe-Insulation eQinisiweyo, ishaneli kwisistim. Uhlobo luvavanyiwe @ 720V DC kwi-60 s | ||
Ikhowudi yeTempile yaseMntla Melika | T4A | T5 |
- Sebenzisa olu lwazi lweCandelo loMqhubi ukucwangcisa umzila womqhubi. Jonga i-Industrial Automation Wiring kunye neziKhokelo zokuGrounding, ukupapashwa kwe-1770-4.1.
- I-RTB yokubambela izikrufu kufuneka ziqiniswe ngesandla. Akufunekanga ziqiniswe kusetyenziswa isixhobo sombane.
IiNgcaciso zeNgeniso
Uphawu lophawu | 2085-IF4 | 2085-IF8, 2085-IF8K |
Inani lamagalelo | 4 | 8 |
IsiGqibo Voltage yangoku | amasuntswana ali-14 (amasuntswana ali-13 kunye nophawu)1.28 mV/cnt unipolar; 1.28 mV/cnt bipolar1.28 µA/cnt | |
Ifomathi yedatha | Ekhohlo kufanelekile, 16 bit 2 s umphelelisi | |
Uhlobo loguqulo | I-SAR | |
Ireyithi yokuhlaziya | <2 ms ngejelo ngalinye elivuliweyo ngaphandle kokukhatywa kwe-50 Hz/60 Hz, <8 ms kulo lonke itshaneli 8 ms kunye no-50 Hz/60 Hz ukulahlwa | |
Ixesha lokuphendula inyathelo ukuya kuthi ga kwi-63% | 4…60 ms ngaphandle kokukhatywa kwe-50Hz/60 Hz – kuxhomekeke kwinani letshaneli evuliweyo kunye noseto lokucoca i-600 ms kunye nokwaliwa kwe-50 Hz/60 Hz | |
I-terminal yegalelo langoku, umsebenzisi uqwalaselwe | 4…20 mA (ehlala ikho) 0…20 mA | |
Igalelo voltagi-terminal, yomsebenzisi eqwalaselweyo | ±10V 0…10V | |
I-impedance yokufaka | Umqulutage iterminal >1 MΩ Itheminali yangoku <100 Ω | |
Ukuchaneka ngokupheleleyo | ±0.10% Isikali esiPheleleyo @ 25 °C | |
Ukuchaneka kokuhamba kunye neTemp | Umqulutagi-terminal – 0.00428 % Isikali esiPheleleyo/ °C Itheminali yangoku – 0.00407 % Isikali esiPheleleyo/ °C |
Iinkcukacha ngegalelo (Iyaqhutywa)
Uphawu lophawu | 2085-IF4 | 2085-IF8, 2085-IF8K |
Ulungelelwaniso luyafuneka | Umzi-mveliso ulinganisiwe. Akukho lulinganiso lwabathengi oluxhaswayo. | |
Ukulayisha ngaphezulu, max | I-30V eqhubekayo okanye i-32 mA eqhubekayo, itshaneli enye ngexesha. | |
Uxilongo lwejelo | Ngaphezulu naphantsi koluhlu okanye imeko yesekethe evulekileyo ngokubika kancinci |
IiNgcaciso zeZiphumo
Uphawu lophawu | 2085-OF4, 2085-OF4K |
Inani leziphumo | 4 |
IsiGqibo Voltage yangoku | 12 bits unipolar; amasuntswana ali-11 kunye nophawu lwe-bipolar2.56 mV/cnt unipolar; 5.13 mV/cnt bipolar5.13 µA/cnt |
Ifomathi yedatha | Ekhohlo kufanelekile, 16-bit 2 s umphelelisi |
Ixesha lokuphendula inyathelo ukuya kuthi ga kwi-63% | 2 ms |
Izinga loguqulo, max | 2 ms ngetshaneli nganye |
Isiphumo sesiphelo sendlela yangoku, umsebenzisi uqwalaselwe | Imveliso ye-0 mA de imodyuli iqwalaselwe 4…20 mA (ehlala ikho)0…20 mA |
Iziphumo voltagi-terminal, yomsebenzisi eqwalaselweyo | ±10V 0…10V |
Umthwalo wangoku kwi-voltagimveliso, max | 3 mA |
Ukuchaneka ngokupheleleyo Voltage terminal Itheminali yangoku | 0.133% Isikali esipheleleyo @ 25 °C okanye ngcono0.425 % Isikali esipheleleyo @ 25 °C okanye ngcono |
Ukuchaneka kokuhamba kunye neTemp | Umqulutage-terminal – 0.0045% Isikali esiPheleleyo/ °C Itheminali yangoku – 0.0069% Isikali esiPheleleyo/ °C |
Umthwalo oxhathisayo kwimveliso ye-mA | 15…500 Ω @ 24V DC |
Iinkcukacha zokusingqongileyo
Uphawu lophawu | Ixabiso |
Ubushushu, ukusebenza | IEC 60068-2-1 (Isibhengezo soVavanyo, Ukusebenza okubandayo),IEC 60068-2-2 (I-Bd yoVavanyo, i-Operating Dry Heat), i-IEC 60068-2-14 (Uvavanyo lwe-Nb, i-Operating Thermal Shock):-20…+65 ° C (-4…+149 °F) |
Iqondo lobushushu, umoya oyingqongileyo, max | 65 °C (149 °F) |
Ubushushu, ukungasebenzi | IEC 60068-2-1 (uVavanyo lwe-Ab, uVavanyo lwe-Ab olungapakishwanga oluNgapakishwanga oluNgapakishwanga lubandayo),IEC 60068-2-2 (uVavanyo lwe-Bb, uVavanyo lwe-Bb olungapakishwanga oluNgapakishwanga oluNgapakishwayo oluNgapakishwayo oluNgapakishwayo oluNgapakishwayo noBushushu oBomileyo),IEC 60068-2-14 (uVavanyo lweNa, olungapakishwanga olungapakishwanga lwe-Nonoperating Thermal Shock):-40 +85 °C (-40…+185 °F) |
Ubuntu bezizalwane | IEC 60068-2-30 (Uvavanyo lwe-Db, olungapakishwanga Damp Ubushushu): 5…95% ukunganyusi |
Ukungcangcazela | IEC 60068-2-6 (Vavanya i-Fc, i-Operating): 2 g @ 10…500 Hz |
Ukothuka, ukusebenza | IEC 60068-2-27 (Vavanya i-Ea, Umothuko ongapakishwanga): 25 g |
Umothuko, awusebenzi | IEC 60068-2-27 (I-Ea yoVavanyo, Umothuko ongapakishwanga): 25 g – ye-DIN kaloliwe yokukhwela i-35 g – ukwenzela ukunyuswa kwephaneli |
Izinto ezikhutshwayo | IEC 61000-6-4 |
Ukungakhuseleki kwe-ESD | IEC 61000-4-2: 6 kV ukukhutshwa koqhagamshelwano 8 kV ukukhutshwa komoya |
Iinkcukacha zokusingqongileyo (Iyaqhutywa)
Uphawu lophawu | Ixabiso |
I-radiated RF immunity | IEC 61000-4-3:10V/m ene-1 kHz sine-wave 80% AM ukusuka kwi80…6000 MHz |
EFT/B ukunganyangeki | IEC 61000-4-4:±2 kV @ 5 kHz kwizibuko zemiqondiso±2 kV @ 100 kHz kumazibuko omqondiso |
I-immunity engapheliyo | IEC 61000-4-5: ± 1 kV umgca womgca (DM) kunye ± 2 kV umgca-umhlaba (CM) kumazibuko omqondiso |
Kuqhutywe i-RF immunity | IEC 61000-4-6:10V iirms ezine-1 kHz sine-wave 80% AM ukusuka kwi-150 kHz…80 MHz |
Iziqinisekiso
Isiqinisekiso (xa imveliso i iphawulwe)(1) | Ixabiso |
c-UL-us | Izixhobo zoLawulo lwezoShishino lwe-UL, eziqinisekisiweyo zase-US naseKhanada. Jonga uUL File E322657.UL Uluhlu lweKlasi yoku-I, iCandelo le-2 Iqela A, B, C, D Iindawo ezinobungozi, eziqinisekisiweyo ze-US kunye neKhanada. Jonga uUL File E334470 |
CE | I-European Union 2014/30/EU EMC Directive, ihambelana ne: EN 61326-1; IiMeas./Control/Lab., IiMfuno zoShishino EN 61000-6-2; Ukhuselo loShishino EN 61000-6-4; Ukukhutshwa kwamashishiniEN 61131-2; Abalawuli abaCwangcisiweyo (Isiqendu 8, uMmandla A & B) I-European Union 2011/65/EU RoHS, ihambelana ne: EN IEC 63000; Amaxwebhu obugcisa |
RCM ulwandiso | UMthetho woNxibelelwano ngeRadiyo waseAustralia, ohambelana ne: EN 61000-6-4; Ukukhutshwa kwamashishini |
KC | UBhaliso lwaseKorea lweZixhobo zoSasazo kunye noNxibelelwano, oluthobela: Inqaku lama-58-2 loMthetho wamaza eRadio, iGatya lesi-3 |
I-EAC | I-Russian Customs Union TR CU 020/2011 EMC Technical Regulation Russian Customs Union TR CU 004/2011 LV Technical Regulation |
Morokho | Arrêté ministériel n ° 6404-15 du 29 ramadan 1436 |
UKCA | 2016 No.. 1091 – Electromagnetic Compatibility Regulations 2016 No. 1101 – Electrical Equipment (Safety) Regulations2012 No. 3032 – Unyino lokuSetyenziswa kwezinto ezithile ezinobungozi kwiMithetho yoMbane kunye ne-Electronic Equipment Regulations |
Inkxaso yeRockwell Automation
Sebenzisa ezi zixhobo ukufikelela kulwazi lwenkxaso.
Iziko leNkxaso yobuGcisa | Fumana uncedo malunga neevidiyo, ii-FAQ, incoko, iiforam zabasebenzisi, kunye nohlaziyo lwesaziso semveliso. | rok.auto/support |
Okubelelwe elwazini | Fikelela kumanqaku esiseko soLwazi. | rok.auto/knowledgebase |
Iinombolo zeFowuni zeNkxaso yobuGcisa beNgingqi | Khangela inombolo yefowuni yelizwe lakho. | rok.auto/phonesupport |
Ithala leencwadi | Fumana imiyalelo yokufakela, iimanyuwali, iincwadana, kunye noshicilelo lwedatha yobugcisa. | rok.auto/literature |
Ukuhambelana kweMveliso kunye neZiko lokuKhuphela (PCDC) | Khuphela i-firmware, ehambelana nayo files (ezifana ne-AOP, EDS, kunye ne-DTM), kunye nokufikelela kumanqaku okukhutshwa kwemveliso. | rok.auto/pcdc |
Ingxelo yoxwebhu
izimvo zethu zisinceda ukuba sikhonze iimfuno zakho zamaxwebhu ngcono. Ukuba unazo naziphi na iingcebiso malunga nendlela yokuphucula
umxholo wethu, gcwalisa ifom kwi-rok.auto/docfeedback.
Inkunkuma yoMbane kunye neZixhobo zoMbane (WEEE)
Ekupheleni kobomi, esi sixhobo kufuneka siqokelelwe ngokwahlukileyo kuyo nayiphi na inkunkuma kamasipala engalungiswanga.
I-Rockwell Automation igcina ulwazi lwangoku lokuthotyelwa kwemveliso yendalo kuyo webindawo kwi rok.auto/pec.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Umnxeba: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Qhagamshelana nathi.
Inkxaso kubathengi
U-Allen-Bradley, ukwandisa amathuba omntu, i-FactoryTalk, i-Micro800, i-Micro830, i-Micro850, i-Micro870, i-Rockwell Automation, kunye ne-TechConnect ziimpawu zorhwebo ze-Rockwell Automation, Inc. Iimpawu zorhwebo ezingezizo ze-Rockwell Automation ziyipropati yeenkampani zabo.
Ukupapashwa 2085-IN006E-EN-P - Agasti 2022 | I-Supersedes Publication 2085-IN006D-EN-P-Disemba 2019
Ilungelo lokushicilela © 2022 Rockwell Automation, Inc. Onke amalungelo agciniwe. Ishicilelwe eSingapore.
Amaxwebhu / Izibonelelo
![]() |
Allen-Bradley 2085-IF4 Micro800 4-Channel kunye 8-Channel Analog Vol.tagI-e-iNgeniso yangoku kunye neeModyuli zokuPhuma [pdf] Incwadi Yomyalelo 2085-IF4, 2085-IF8, 2085-IF8K, 2085-OF4, 2085-OF4K, 2085-IF4 Micro800 4-Channel kunye 8-Channel Analog Vol.tagI-e-Yangoku yokuNgena kunye neeModyuli zokuPhuma, i-2085-IF4, i-Micro800 i-4-Channel kunye ne-8-Channel Analog Vol.tagIimodyuli zangoku zeNgeniso kunye neZiphumo, VoltagI-e-yangoku yokuNgena kunye neeModyuli zokuPhuma, iiModyuli zokuNgenisa kunye neZiPhumo, iimodyuli, iVol ye-AnalogtagI-e-iNgeniso yangoku kunye neeModyuli zokuPhuma |