CITADEL MESH
MIDI TOWER CASE
用户手册
配件包内容
面板拆卸
前/侧面板拆卸
- Take off the front panel by pulling carefully from the bottom of the panel
- Remove the left side panel by pulling on the pull tab & swinging the door outwards, then lift off the hinges at the back of the case.
- Remove the right side pane by removing the two rear thrum screws and sliding the panel backwards
MOTHERBOARD INSTALLA
主板安装
- Align your motherboard with the chassis to locate where the stand-offs should be installed Once done, remove the motherboard and fasten stand-offs accordingly
- Insert your motherboard I/O plate into the cutout at the rear of the case
- Place your motherboard into the chassis, making sure the rear ports fit into the I/O plate
- Use the provided motherboard screws to attach your motherboard to the chassis
电源安装
电源安装
- Place PSU in the bottom rear of the case, within the PSU shroud
- 对齐孔并用螺丝固定
显卡/PCI-E 卡安装
显卡/PCI-E 卡安装
- 必要时卸下后 PCI-E 插槽盖(取决于卡的插槽大小)
- Carefully position and slide your PCI-E card into place, then secure with the add-on card screws supplied If mounting vertically, attach the vertical GPU mount to the PSU shroud, attach the Klink PCI-E Riser Cable (Sold separately). remove the rear PCI-E slot covers and put the card into place, mounting to the PCI-E Riser cable mount securely
- Remember to attach the other end of the PCI-E Riser cable to your motherboards PCI-E 16x slot
2.5″ SDD INSTALLATION (F)
2.5英寸SSD安装(正面)
- Align your drive over the screw holes and secure with screws from the rear
2.5 英寸 SDD 安装 (R)
2.5 英寸 SSD 安装(背面)
Place your SSD on top of the HDD bracket and secure with screws
3.5英寸硬盘安装
3.5英寸硬盘安装
- Slide the drive into/onto the 3,5″ bay at the rear of the case
- Secure the drive on the both sides using the provided screws and hand tighten
顶部风扇安装
顶部风扇安装
- Remove the dust filter from the top of the case
- Align your fan(s) to the screw holes on the top of the chassis and secure with screws
- Replace your dust filter once secured
前/后风扇安装
前/后风扇安装
- Align your fan to the screw holes on the chassis and secure with screws
水冷散热器安装
水冷散热器安装
- 将风扇固定在散热器上,然后从外部用螺丝固定将散热器固定在机箱内
输入输出面板安装
输入输出面板安装
Carefully check the labelling of each connector from the 1/0 panel to identify their function
Cross reference with the motherboard manual to locate where each wire should be installed, then secure one at a time, Please ensure they are installed in the correct polarity to avoid non-function or damage
文件/资源
![]() |
KOLINK ANL-INT Citadel Mesh Midi 塔式机箱 [pdf] 用户手册 ANL-INT、ANL-INT Citadel Mesh Midi 塔式机箱、Citadel Mesh Midi 塔式机箱、Mesh Midi 塔式机箱、Midi 塔式机箱、塔式机箱 |