CITADEL MESH
MIDI TOWER CASE
INCWADI YOKUSEBENZISA
I-ACESSORY PACK IZIQULATHO
UKUSUSWA KWEPANELI
UKUSUSWA KWEPANELI ANGAPHAMBI / Ecaleni
- Take off the front panel by pulling carefully from the bottom of the panel
- Remove the left side panel by pulling on the pull tab & swinging the door outwards, then lift off the hinges at the back of the case.
- Remove the right side pane by removing the two rear thrum screws and sliding the panel backwards
MOTHERBOARD INSTALLA
UKUFAKWA KWEBHODI YOMAMA
- Align your motherboard with the chassis to locate where the stand-offs should be installed Once done, remove the motherboard and fasten stand-offs accordingly
- Insert your motherboard I/O plate into the cutout at the rear of the case
- Place your motherboard into the chassis, making sure the rear ports fit into the I/O plate
- Use the provided motherboard screws to attach your motherboard to the chassis
UKUFAKELWA KOMNIKELO WAMANDLA
UKUFAKELWA KOMNIKELO WAMANDLA
- Place PSU in the bottom rear of the case, within the PSU shroud
- Ukulungelelanisa imingxuma kwaye ukhusele ngezikrufu
IKHADI LEMIZOBO/I-PCI-E UKUFAKELWA KWEKHADI
IKHADI LEMIZOBO/I-PCI-E UKUFAKELWA KWEKHADI
- Susa ngasemva PCI-E amagqubu slot njengoko kuyimfuneko (kuxhomekeke slot ubukhulu ikhadi lakho)
- Carefully position and slide your PCI-E card into place, then secure with the add-on card screws supplied If mounting vertically, attach the vertical GPU mount to the PSU shroud, attach the Klink PCI-E Riser Cable (Sold separately). remove the rear PCI-E slot covers and put the card into place, mounting to the PCI-E Riser cable mount securely
- Remember to attach the other end of the PCI-E Riser cable to your motherboards PCI-E 16x slot
2.5″ SDD INSTALLATION (F)
2.5″ UKUFAKWA kwe-SSD (PHAMBI)
- Align your drive over the screw holes and secure with screws from the rear
2.5″ UKUFAKWA kwe-SDD (R)
2.5″ UKUFAKWA kwe-SSD (NGEMVA)
Place your SSD on top of the HDD bracket and secure with screws
3.5″ UKUFAKELWA kweHDD
3.5″ UKUFAKELWA kweHDD
- Slide the drive into/onto the 3,5″ bay at the rear of the case
- Secure the drive on the both sides using the provided screws and hand tighten
UKUFAKWA KWEFAN OKUPHEZULU
UKUFAKWA KWEFAN OKUPHEZULU
- Remove the dust filter from the top of the case
- Align your fan(s) to the screw holes on the top of the chassis and secure with screws
- Replace your dust filter once secured
UKUFAKELWA KWEFANI NGAPHAMBI/NGANGAMVA
UKUFAKELWA KWEFANI NGAPHAMBI/NGANGAMVA
- Align your fan to the screw holes on the chassis and secure with screws
UKUFAKWA KWERADIATOR YOKUXOLISA AMANZI
UKUFAKWA KWERADIATOR YOKUXOLISA AMANZI
- Khusela iifeni kwiradiyetha, emva koko uqinise irediyetha ngaphakathi kwi-chassis ngokukhusela ngezikrufu ezisuka ngaphandle.
I/O UKUFAKWA KWEPHANSI
I/O UKUFAKWA KWEPHANSI
Carefully check the labelling of each connector from the 1/0 panel to identify their function
Cross reference with the motherboard manual to locate where each wire should be installed, then secure one at a time, Please ensure they are installed in the correct polarity to avoid non-function or damage
Amaxwebhu / Izibonelelo
![]() |
KOLINK ANL-INT Citadel Mesh Midi Tower Case [pdf] Incwadi yokusebenzisa ANL-INT, ANL-INT Citadel Mesh Midi Tower Case, Citadel Mesh Midi Tower Case, Mesh Midi Tower Case, Midi Tower Case, Tower Case |