CITADEL MESH
MIDI TOWER CASE

KOLINK ANL-INT Citadel Mesh Midi Tower Case

USER MANUAL

ACCESSORY PACK CONTENTS

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 1

PANEL REMOVAL

FRONT/SIDE PANEL REMOVAL

  • Take off the front panel by pulling carefully from the bottom of the panel
  • Remove the left side panel by pulling on the pull tab & swinging the door outwards, then lift off the hinges at the back of the case.
  • Remove the right side pane by removing the two rear thrum screws and sliding the panel backwards

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 2

MOTHERBOARD INSTALLA

MOTHERBOARD INSTALLATION

  • Align your motherboard with the chassis to locate where the stand-offs should be installed Once done, remove the motherboard and fasten stand-offs accordingly
  • Insert your motherboard I/O plate into the cutout at the rear of the case
  • Place your motherboard into the chassis, making sure the rear ports fit into the I/O plate
  • Use the provided motherboard screws to attach your motherboard to the chassis

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 3

POWER SUPPLY INSTALLATION

POWER SUPPLY INSTALLATION

  • Place PSU in the bottom rear of the case, within the PSU shroud
  • Align the holes and secure with screws

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 4

GRAPHICS CARD/PCI-E CARD INSTALLATION

GRAPHICS CARD/PCI-E CARD INSTALLATION

  • Remove the rear PCI-E slot covers as necessary (depending on the slot size of your card)
  • Carefully position and slide your PCI-E card into place, then secure with the add-on card screws supplied If mounting vertically, attach the vertical GPU mount to the PSU shroud, attach the Klink PCI-E Riser Cable (Sold separately). remove the rear PCI-E slot covers and put the card into place, mounting to the PCI-E Riser cable mount securely
  • Remember to attach the other end of the PCI-E Riser cable to your motherboards PCI-E 16x slot

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 5

2.5″ SDD INSTALLATION (F)

2.5″ SSD INSTALLATION (FRONT)

  • Align your drive over the screw holes and secure with screws from the rear

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 6

2.5″ SDD INSTALLATION (R)

2.5″ SSD INSTALLATION (REAR)
Place your SSD on top of the HDD bracket and secure with screws

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 7

3.5″ HDD INSTALLATION

3.5″ HDD INSTALLATION

  • Slide the drive into/onto the 3,5″ bay at the rear of the case
  • Secure the drive on the both sides using the provided screws and hand tighten

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 8

TOP FAN INSTALLATION

TOP FAN INSTALLATION

  • Remove the dust filter from the top of the case
  • Align your fan(s) to the screw holes on the top of the chassis and secure with screws
  • Replace your dust filter once secured

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 9

FRONT/REAR FAN INSTALLATION

FRONT/REAR FAN INSTALLATION

  • Align your fan to the screw holes on the chassis and secure with screws

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 10

WATERCOOLING RADIATOR INSTALLATION

WATERCOOLING RADIATOR INSTALLATION

  • Secure the fans to the radiator, then fasten the radiator inside the chassis by securing with screws from the outside

I/O PANEL INSTALLATION

I/O PANEL INSTALLATION
Carefully check the labelling of each connector from the 1/0 panel to identify their function
Cross reference with the motherboard manual to locate where each wire should be installed, then secure one at a time, Please ensure they are installed in the correct polarity to avoid non-function or damage