Coolgear-LOGO

Adaptor Ethernet cu 1 port la magistrală CAN Coolgear pentru programare CAN

Coolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-PRODUCT

Specificații

Informații despre produs

The CAN Programming Guide by Coolgear Inc. provides a detailed guide on programming the Controller Area Network (CAN) devices using their application programming interface.

Instalare

  • Pentru a instala DLL-ul, LIB-ul și antetul files, copy them to your application project directory. The specific locations may vary depending on your programming language and compiler configurations.
  • Refer to your programming environment documentation for guidance.

Types and Structures

  • The guide provides details on various types and structures used in CAN programming, like CAN_HANDLE, CAN_ERRORS, CAN_STATUS, and CAN_MSG.

ExampCodul

  • Ghidul include example code snippets to help you understand how to implement the functions in your application.

Istoricul revizuirilor

Revizuire Data Comentarii
1.0 04/25/2024             First Release

Introducere

  • Thank you for purchasing Coolgear’s 1 Port Serial RS232 to CAN Bus Adapter. A Controller Area Network (CAN) is a high-integrity asynchronous serial bus system for networking intelligent devices. It is often used in automotive and industrial systems.
  • The CG-1P232CAN is designed to provide a fast, simple way to communicate with CAN bus devices. Connected to a serial port on your computer, the CG-1P232CAN instantly adds an industrial CAN bus channel to your host system.
  • The CG-1P232CAN provides a cost-effective solution for customers to enable communication with CAN bus devices.
  • The solution designed by the ARM Cortex-M0 32-bit microcontroller makes it very flexible in handling small bursts of CAN frames at a high speed.
  • Plugging the CG-1P232CAN into the serial port, the CG-1P232CAN adapter provides instant connectivity to CAN bus devices.
  • The CG-1P232CAN provides an industrial solution for applications of CAN bus multi-drop communications over short and long distances.
  • The CG-1P232CAN provides DC +5V/+12V 500mA power for external devices and is powered from an external DC 12V power supply.

Caracteristici:

  • Adds a CAN bus port on your computer by connecting to the RS-232 serial port
  • One DB9 female connector (serial port)
  • One DB9 male connector (CAN bus port)
  • Includes one serial cable. Cable length: 100cm
  • Powered by an external DC 12V power adapter
  • Provides DC +5V/+12V 500mA power for external devices
  • LEDs indicate initialization and CAN bus status
  • CAN bus speed up to 1 Mbps
  • Supports CAN 2.0A and CAN 2.0B protocols
  • Supported CAN modes
  • Standard mode: normal operation on the CAN bus
  • Listen mode: passive receiving of CAN frames
  • Echo mode: transmitter also receives sent frames (for testing purposes)
  • CG-1P232CAN can be controlled over a serial port using simple ASCII commands
  • Wide ambient temperature operation 0°C to 60°C (32°F to 140°F)
  • Aprobare CE, FCC
  • Designed by the ARM Cortex-M0 32-bit microcontroller
  • Drivers are provided for Windows and Linux OS
  • Supports SocketCAN (slcan driver) since kernel 2.6.38+

DIAGRAM OF CG-1P232CAN

Coolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-1

DISPOSARE PCBCoolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-2

DIAGRAMĂ BLOCCoolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-3

PIN-OUT INFORMATION

The following is the pin-out of the connector for RS-232 serial port signals.Coolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-4

RS-232 Serial Port Pin-out for DB9 Female Connector

Numărul PIN Semnale Descriere
1 DCD Detectare purtător de date
2 RxD Receive Serial Data
3 TxD Transmit Serial Data
4 Rezervat
5 GND Pământ de semnal
6 DSR Set de date gata
7 RTS Solicitare de trimitere
8 CTS Ștergeți pentru a trimite
9 Rezervat
  • The following are the pin-out of the DB-9 male connector and the terminal block for CAN bus signals.Coolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-5

CAN Bus Pin-out for DB9 Male Connector

Numărul PIN Semnale Descriere
1 CAN_V + Provides +DC 5V or 12V power (optional)
2 POT SĂ CAN_L bus line (dominant level is low)
3 CAN_GND Semnal de teren
4 Rezervat
5 Rezervat
6 CAN_GND Semnal de teren
7 CAN_H CAN_H bus line (dominant level is high)
8 Rezervat
9 CAN_V + Provides +DC 5V or 12V power (optional)

Coolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-6

CAN Bus Pin-out for 5-pin Terminal Block

Numărul PIN Semnale Descriere
1 CAN_GND Semnal de teren
2 CAN_H CAN_H bus line (dominant level is high)
3 POT SĂ CAN_L bus line (dominant level is low)
4 -CAN_V+ Provides +DC 5V or 12V power (optional)
5 CAN_GND Semnal de teren

Enabling the DC +5V or DC +12V Power for External Devices

Outside the unit, there is a 3-pin DIP switch (SW) which are settings used for enabling 5V or 12V (500mA max.) power for external devices.

SW FUNCŢIE
PIN 1 ON Enable DB9 pin 1 to provide 5V or 12V power for external devices
OFF Disable the 5V or 12V power on pin 1
PIN 2 ON Enable DB9 pin 9 to provide 5V or 12V power for external devices
OFF Disable the 5V or 12V power on pin 9
PIN 3 ON Enable terminal block pin 4 to provide 5V or 12V power for external devices
OFF Disable the 5V or 12V power on terminal block pin 4
  • Inside the unit, there are three 3-pin header blocks (J1, J2, J3), which are jumpers for selecting 5V or 12V power for external devices.Coolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-7
JUMPER FUNCŢIE
J1 pin 1, 2 short Select DB9 pin 1 to provide 5V power for external devices
J1 pin 2, 3 short Select DB9 pin 1 to provide 12V power for external devices
J2 pin 1, 2 short Select DB9 pin 9 to provide 5V power for external devices
J2 pin 2, 3 short Select DB9 pin 9 to provide 12V power for external devices
J3 pin 1, 2 short Select terminal block pin 4 to provide 5V power for external devices
J3 pin 2, 3 short Select terminal block pin 4 to provide 12V power for external devices

Rezistențe de terminare

  • The serial-to-CAN adapter does not provide CAN bus termination resistors. A CAN bus network requires 120Ω termination resistors at each end.
  • Generally, this must be done in the cabling. Since this depends on the installation of connections, please check your CAN bus cable specification for proper impedance matching.Coolgear-CAN-Programming-1-Port-Ethernet-To-CAN-Bus-Adapter-FIG-8

DESCRIEREA FUNCȚIEI

Indicatoare LED

  • The CG-1P232CANadapter has three LEDs (red LED, green LED, yellow LED) to indicate power and CAN bus statuses.
  • The red LED indicates CG-1P232CAN adapter power; the green LED indicates CAN bus data activity, and the yellow LED indicates a CAN bus error.
  • The following are the definition of different LED combinations.

A: Power up (device initialized)

  • After CG-1P232CAN powers up (device initialized), the red LED turns on and the green & yellow LEDs flash four times to indicate that the CG-1P232CANadapter has been initialized.

B: CAN bus channel open/close

  • When CAN bus channel opens, the green LED will turn on to indicate that the CAN bus channel is open; When CAN bus channel closes, the green LED will turn off to indicate that the CAN bus channel is closed.

C: CAN Bus Data Activity

  • When a CAN data frame is sent or received, the green LED flashes continuously to indicate CAN bus data I/O activity.

D: CAN Bus Error

  • When an error occurs on the CAN bus, the yellow LED flashes continuously to indicate a CAN bus error.

Set de comenzi ASCII

  • With simple ASCII commands the CG-1P232CAN adapter can be controlled over the serial port. Users can send/receive commands from any simple serial terminal program.
  • Examppe: Set bitrate to 500 Kbps, open CAN channel, send CAN frame (ID = 002h, DLC = 3, Data = 11 22 33), close CAN.
Comanda Răspuns Funcţie
S6[CR] [CR] Set the bitrate of the CG-1P232CAN adapter to 500 Kbps
O[CR] [CR] Open CAN channel
t0023112233[CR] z[CR] Send CAN message (ID = 002h, DLC = 3, Data = 11 22 33)
C[CR] [CR] Close the CAN channel

Lista de comenzi

  • The commands are line-based and terminated with the newline character CR (0xD). On error, the response will be 0x7 (BELL).
  • The “help” command (‘H’, ‘h’, or ‘?’) will list supported commands.
Comanda Răspuns Funcţie
H[CR] [CR] List all supported commands
h[CR] [CR]
?[CR] z[CR]
  • Examppe: H[CR]

Cod de returnare

List of Supported Commands:

  • 'SAU’ – Open the channel in Normal mode
  • „L” – Open the channel in Listen Only mode
  • „Y” – Open the channel in Loopback mode
  • „C” – Close CAN Channel
  • „S” – Set standard CAN bitrate
  • 's' – Set non-standard CAN bitrate
  • 't' – Transmit a standard frame
  • „T” – Transmit an extended frame
  • 'r' – Transmit a standard remote request frame
  • „R” – Transmit an extended remote request frame
  • „Z” – Set timestamp pornit/oprit
  • ‘m – Set acceptance mask
  • 'M' – Set acceptance filter
  • 'F' – Read status flag
  • „V” – Check software version
  • 'N' – Check serial number
  • ‘m – Set acceptance mask
  • 'M’ – Set acceptance filter
  • „RST’ – Reset CG-1P232CAN Adapter
  • ‘H’, ‘h’, or ‘?’ – List supported commands

Opening the CAN Bus Channel

  • The CAN bus channel will be opened with the command O[CR], L[CR], or Y[CR].
  • The command O[CR] will open the CAN bus channel in normal operation mode, and the command L[CR] will open the CAN bus channel in listen-only mode, in which no bus interaction will be done from the controller.
  • The command Y[CR] will open the CAN bus channel in a loop-back mode, in which the CG-1P232CAN adapter will also receive the frames that it sends. Before you use one of the commands, you should set a bitrate with the commands S or s.
Comanda Răspuns Funcţie
O[CR] [CR] Open the channel in Normal mode
L[CR] [CR] Open the channel in Listen Only mode
Y[CR] [CR] Open the channel in Loopback mode

Closing the CAN Bus Channel

The CAN bus channel will be closed with the command C[CR]. The command can only be used if the CAN bus channel is open.

Comanda Răspuns Funcţie
C[CR] [CR] Close the CAN channel if it is open

Setting CAN Bitrate (Standard)

  • The CAN bus bitrate can be set with the command SX[CR]. The command can only be used if the CAN bus channel is closed.
Comanda Răspuns Funcţie
S6[CR] S00[CR] [CR] Set the bitrate of the CG-1P232CAN adapter to 500 Kbps
S0[CR] [CR] Open CAN channel
S1[CR] S2[CR] [CR] Send CAN message (ID = 002h, DLC = 3, Data = 11 22 33)
S3[CR] [CR] Close the CAN channel
S4[CR] [CR]  
S5[CR] [CR]  
S6[CR] [CR]  
S7[CR] [CR]  
S8[CR] [CR] Set the CAN bus bitrate to 1M

Specificații

General

Port serial Bosch C_CAN module
Can Bus Supports CAN 2.0A and CAN 2.0B
Chipset ARM Cortex-M0 32-bit microcontroller

Can Bus

Numărul de porturi 1
Conector Conector tată DB9
CAN Bus Speed CAN 2.0A / 2.0B 5kbps to 1Mbps for transmit & receive
Semnale CAN_H, CAN_L, CAN_GND, CAN_V+
CAN Bus Controller Bosch C_CAN module
LED Power, CAN bus data activity, CAN bus error
CAN Bus Mode Standard mode: normal operation on the CAN bus. Listen mode: passive receiving of CAN Frames

Echo mode: transmitter also receives sent frames (for testing purposes)

Protecţie +/-16 KV ESD protection for CAN signals

Caracteristici software

API Library Supports C/C++, C#, VB.NET and LabVIEW
Utilitate On-board firmware update utility
Instrumente de monitorizare Supported by CANHacker, the Titan CAN test program

Cerința de putere

Intrare de putere DC 12V external power adapter
Consumul de energie Max. 80mA@12VDC (no external devices)

Mecanic

Carcasa SECC sheet metal (1mm)
Dimensiuni 81 mm x 81 mm x 24 mm (L x l x înălțime)
Greutate 175 g

de mediu

Temperatura de operare 0°C până la 55°C (32°F până la 131°F)
Temperatura de depozitare -20°C până la 75°C (-4°F până la 167°F)
Umiditatea de funcționare 5% până la 95% RH
Aprobari de siguranta CE, FCC

Contactaţi-ne:

  • Coolgear Inc.
  • 5120 110th Avenue North
  • Clearwater, Florida 33760 SUA
  • Taxă Gratuit: 18886882188
  • Local: 17272091300
  • Fax: 17272091302

Siguranţă

  • Read the entire Installation Guide before implementing this product for your application. This guide contains important information about electrical connections that must be followed for safe and proper operation.
  • Inspectați cu atenție produsul pentru defecte vizuale înainte de a-l folosi.
  • Keep away from areas where moisture builds, This product contains electrical components that can be damaged by moisture buildup, which can adversely affect your equipment connected to it.
  • Nu dezasamblați produsul. Manipularea componentelor interne ale produsului îl poate expune la pericole ESD (descărcări electrostatice) care pot afecta funcționarea dispozitivului.
  • Dacă acest produs nu funcționează corect, trimiteți un e-mail echipei noastre de asistență la support@coolgear.com.

EXPERȚI ÎN ÎNCĂRCARE ȘI CONECTIVITATE USB

În cadrul fiecărei mașini grozave

  • For over 20 years, our rugged, off-the-shelf USB hubs, chargers, and serial products are ready to go for your next project.
  • Based in the US, Coolgear has successfully engineered and deployed millions of connectivity solutions into industrial, medical, automotive, commercial, and aerospace industries.
  • Înțelegem importanța fiabilității, a calității construcției și considerăm toate aplicațiile clienților noștri ca fiind critice, dorind să asigurăm integrări de lungă durată fără evenimente.

Declarație de conformitate

  • View conformitatea în fișa de date tehnice a produsului respectiv, care se găsește pe lista online a produsului.

Suport tehnic

  • When you reach out to Coolgear support, you’ll find yourself in the hands of a solution-oriented and knowledgeable expert ready to answer whatever question you throw at them.
  • If you ever need help with your product, visit coolgear.com/support for support tickets, downloads, and other support resources. For the latest drivers, please visit coolgear.com/download.

garanție

Garanția standard a produsului

  • One (1) Year Warranty from Date of Purchase Invoice. Coolgear will repair or replace any Product determined to be defective and which has been returned, at your risk and expense, to Coolgear. Where Coolgear determines in its sole judgment that repair or replacement of such Product is not reasonable, Coolgear will keep the non-conforming Product and refund to you the amount you paid for such Product. Returned Products shall be subject to the balance of the Warranty Period otherwise applicable.
  • Any reconditioned parts used by Coolgear shall be subject to all the same provisions as otherwise applicable to new parts.
  • THE FOREGOING DESCRIBES COOLGEAR’S SOLE LIABILITY, AND YOUR SOLE REMEDY, FOR ANY BREACH OF WARRANTY.
  • IF YOU DO NOT AGREE WITH THE TERMS OF THIS LIMITED WARRANTY, YOU MUST RETURN THE PRODUCTS UNUSED AND IN THEIR ORIGINAL CONTAINERS TO YOUR ORIGIN OF PURCHASE.

Limitarea răspunderii

  • This Limited Warranty does not cover: (i) defects or damages resulting from natural causes, casualty, accident, misuse or abuse, neglect, alterations, service or repair by other than Coolgear, including without limitation by you; (ii) improper installation or de-installation, operation or maintenance, improper connections with peripherals or other causes not arising out of defects in the materials or workmanship of Products; (iii) any Product for which the warranty sticker has been removed, modified or defaced; (iv) normal wear and tear; (v) damage to or loss of repaired or replaced Products during shipping by Coolgear except when such damage or loss is caused by poor or inadequate packaging by Coolgear; or (vi) Products purchased outside the United States. UNDER
  • NO CIRCUMSTANCES WILL COOLGEAR BE LIABLE FOR ANY LOSS OF USE, INTERRUPTION OF BUSINESS OR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING LOST PROFITS) REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT PRODUCT LIABILITY OR OTHERWISE, EVEN IF COOLGEAR HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
  • IN NO EVENT SHALL THE TOTAL LIABILITY OF COOLGEAR HEREUNDER EXCEED THE GREATER OF $50.00 OR THE AMOUNT YOU ACTUALLY PAID FOR THE PRODUCT GIVING RISE TO SUCH LIABILITY, REGARDLESS OF THE CAUSE OF ACTION, IN CONTRACT, TORT, STRICT LIABILITY, OR OTHERWISE. NOT ALL JURISDICTIONS ALLOW SUCH LIMITATIONS OF DAMAGES, SO THE FOREGOING LIMITATIONS MAY NOT APPLY TO YOU.
    © 2024 Coolgear, Inc. All Rights Reserved. All products and accompanying digital documentation, including images, are the property and/or trademarks of Coolgear Inc. Coolgear Inc. is continuously improving upon its products.
  • Specificațiile produsului pot fi modificate fără notificare prealabilă.
  • Nevoie de ajutor? Vizita: coolgear.com/support
  • Coolgear, Inc.
  • Versiune: 1.0
  • Data: 04/25/2024

Întrebări frecvente

  • Î: Există un program de instalare specific pentru DLL?
    • A: No, there is no specific DLL installer provided. You need to manually copy the DLL, LIB, and Header files to your application project directory.
  • Î: Care sunt valorile implicite pentru acceptance_code și acceptance_mask?
    • A: The default values are set to allow passing all frames – Acceptance Filter = 0x7FF for standard messages and 0x1FFFFFFF for extended messages.