Manual do usuario da cuña de posicionamento reutilizable da serie HOVERTECH FPW-R-15S

Cuña de posicionamento reutilizable da serie FPW-R-15S

Especificacións

Produto: Cuña de posicionamento reutilizable
Material de cuberta: Dartex (top portion), PVC
Non-Skid
Construción: Sonic Welding (top cover Dartex to
Dartex seams), Sewn (Dartex to non-slip seams)
Lonxitudes dispoñibles: FPW-R-15S (15 inches / 38 cm),
FPW-R-20S (20 inches / 51 cm), FPW-RB-26S (26 inches / 66 cm)
Anchos dispoñibles: FPW-R-15S (11 inches / 28 cm),
FPW-R-20S (11 inches / 28 cm), FPW-RB-26S (12 inches / 30 cm)
Alturas dispoñibles: FPW-R-15S (7 inches / 18 cm),
FPW-R-20S (7 inches / 18 cm), FPW-RB-26S (8 inches / 20 cm)
Números de modelo: FPW-R-15S, FPW-R-20S,
FPW-RB-26S
Características adicionais: Free of Forever Chemicals
(PFAS)

Instrucións de uso do produto

  1. Center the patient on the HoverMatt or HoverSling with link
    strap(s) unconnected. Ensure the bed is flat.
  2. Place the air supply next to the caregiver on the opposite side
    of the turn direction. Insert the hose into the foot-end of the
    mattress and start the airflow by selecting the appropriate
    botón.
  3. Once fully inflated, slide the patient in the opposite
    direction of the turn, positioning them close to the edge of the
    bed for central alignment.
  4. Position the wedge between the HoverMatt or HoverSling and the
    bed surface with arrows facing up. Place one wedge below the sacrum
    and another one hand’s width above to support the upper body.
  5. Lower the patient onto the wedges, ensuring straps are not
    underneath the HoverMatt or HoverSling. Confirm sacrum is not
    touching the bed, adjust bed head if needed, and raise siderails
    per protocol.

Preguntas frecuentes

1. Can the Reusable Positioning Wedge be laundered?

No, it is recommended not to launder the wedge to maintain its
non-slip benefit.

2. Are replacement covers available for the wedges?

Yes, replacement covers can be purchased separately for the
Reusable Positioning Wedges.

"'

Reusable Wedge Manual
30-Degree Foam Positioning Wedge

Manual de usuario
Visita www.HoverTechInternational.com para outros idiomas

ÍNDICE
Symbol Reference ………………………………………………….2 Intended Use and Precautions………………………………….3 Part Identification – Reusable Wedge…………………………4 Reusable Wedge Product Specifications…………………….4 Instructions for Use ………………………………………………..5 Cleaning and Preventive Maintenance ………………………6 Returns and Repairs………………………………………………..7

Reusable Positioning Wedge User Manual
Referencia de símbolos

CAUTION / WARNING DISPOSAL OPERATING INSTRUCTIONS LATEX FREE LOT NUMBER MANUFACTURER

DATE OF MANUFACTURE MEDICAL DEVICE SERIAL NUMBER DO NOT LAUNDER UNIQUE DEVICE IDENTIFIER

2 | HoverTech

ReusableWedgeManual, Rev. A

Reusable Positioning Wedge User Manual

Uso previsto e precaucións
USO PREVISTO
The HoverTech Reusable Positioning Wedge assists caregivers with patient positioning. Patient turning and wedge placement relieves pressure on bony prominences aiding Q2 compliance. The wedge delivers a 30-degree turning angle for patients at risk for pressure injuries. The anti-slip material keeps the wedge properly placed under the patient and in place with the bed to reduce patient sliding. The wedge may be used with any HoverMatt® Single Patient Use Mattress or HoverSling® Repositioning Sheet.
I N D I C AT I O N S
· Patients that need Q2 turning for pressure off-loading of bony prominences.
· Patients with compromised skin breakdown.
CONTRAINDICACIÓNS
· Do not use with patients whose medical condition contraindicates turning.

CONFIGURACIÓNS DE ATENCIÓN PREVISTAS
· Hospitals, long-term or extended care facilities.
PRECAUTIONS ­ REUSABLE POSITIONING WEDGE
· For in-bed positioning tasks, more than one caregiver may need to be used.
· Use this product only for its intended purpose as described in this manual.
Os carriles laterais deben levantarse cun único coidador.
Do not place the Reusable Positioning Wedge into a pillowcase in order to maintain the non-slip benefit.

ReusableWedgeManual, Rev. A

www.HoverTechInternational.com | 3

Reusable Positioning Wedge User Manual
Part Identification ­ Reusable Positioning Wedge

30-degree angle supports proper off-loading.

Heat sealed seams available on Dartex® cover.

Extra-firm core topped with extra-plush memory foam for enhanced comfort & pressure redistribution.

FPW-R-15S

Reusable 30° Positioning Wedge

Waterfall Flap covers the top half of the zipper enclosure.
Non-slip cover reduces sliding and secures the wedge in place.

Wipeable material -compatible with hospital disinfectants.

Especificacións do produto
REUSABLE POSITIONING WEDGE

Cover Material: Dartex, (top portion), PVC Non-Skid

Construción:

Sonic Welding, (top cover Dartex to Dartex seams) Sewn, (Dartex to non-slip seams)

Length: Width: Height

FPW-R-15S 15″ (38 cm) FPW-R-20S 20″ (51 cm) FPW-RB-26S 26″ (66 cm)
FPW-R-15S 11″ (28 cm) FPW-R-20S 11″ (28 cm) FPW-RB-26S 12″ (30 cm)
FPW-R-15S 7″ (18 cm) FPW-R-20S 7″ (18 cm) FPW-RB-26S 8″ (20 cm)

Model #s: FPW-R-15S FPW-R-20S FPW-RB-26S

Free of Forever Chemicals, (PFAS)

4 | HoverTech

ReusableWedgeManual, Rev. A

Reusable Positioning Wedge User Manual

Instructions for Use with HoverMatt® PROSTM, HoverMatt®, or HoverSling®

WEDGE PL ACEMENT WITH AIR-ASSISTED MATTRESSES ­ PUSH DOWN METHOD (2 CAREGIVERS)

1. Center patient on the HoverMatt or HoverSling, with link strap(s) unconnected. The bed should be in a flat position.
2. Place the air supply next to the caregiver on the opposite side of the turn direction. Insert the hose into the foot-end of the mattress and initiate air flow by selecting the appropriate button for the size of the product being used.
3. Once fully inflated, slide the patient in the opposite direction of the turn, slide them as close to the edge of the bed as possible to ensure that when the patient is repositioned they will be centered on the bed.
4. To turn the patient on their side, the caregiver on the side patient will turn towards will gently push down on the HoverMatt or HoverSling at the patient’s shoulder and hip, while the turning caregiver gently pulls up on the handles. Once the patient is turned on their side, the caregiver the patient is turned towards will stay with the patient while the turning caregiver presses the STANDBY button to stop air flow. The caregiver supporting the patient may hold the handles of the HoverMatt or HoverSling while the other caregiver places the wedges.

5. Place the wedge between the HoverMatt or HoverSling and the bed surface with the arrows facing up. Clinical judgment should be used when positioning wedges. Locate the sacrum and place one wedge below the sacrum. Position the other wedge, one hand’s width above the lower wedge to support the patient’s upper body.
6. Lower the patient onto the wedges, ensure straps are not underneath the HoverMatt or HoverSling. Check wedge placement by placing your hand between the wedges, confirming the sacrum is not touching the bed. Raise the head of the bed as desired and recheck the sacrum. Raise the siderails or follow your facility’s protocol.

WEDGE PL ACEMENT WITH A CEILING OR PORTABLE LIFT (SINGLE CAREGIVER)

1. For use with any HoverMatt or HoverSling products, a ceiling or portable lift can be utilized for patient turns to place the wedge.
2. Raise the siderails on the opposite side of the bed the patient will be turned toward. Ensure the patient is centered, with link strap(s) unconnected, and slide the patient in the opposite direction of the turn using either a supine lift (see the HoverSling User Manual) technique or air-assisted technique as detailed above. This will allow the patient to be centered on the bed when repositioned on the wedges.
3. Attach the shoulder and hip loop straps (HoverSling) or the shoulder and hip handles (HoverMatt) to the hanger bar which should be parallel to the bed. Raise the lift to initiate the turn.

4. Place the wedge between the HoverMatt or HoverSling and the bed surface with the patient side facing up. Clinical judgment should be used when positioning wedges. Locate the sacrum and place one wedge below the sacrum. Position the other wedge, one hand’s width above the lower wedge, to support the patient’s upper body.
5. Lower the patient onto the wedges, ensure straps are not underneath the HoverMatt or HoverSling. Check wedge placement by placing your hand between the wedges, confirming the sacrum is not touching the bed. Raise the head of the bed as desired and recheck the sacrum. Raise the siderails or follow your facility’s protocol.

WEDGE PLACEMENT ­ NON-AIR (2 CAREGIVERS)
1. For use with the non-air HoverMatt® PROSTM or HoverMatt® PROSTM Sling, ensure patient is centered, with link strap(s) unconnected, and slide the patient in the opposite direction of the turn to ensure there is room for the turn with the patient centered in the bed when repositioned. Using good ergonomic stature, manually turn the patient using the turning handles or the sling straps.
2. Place the wedge between the HoverMatt PROS or HoverMatt PROS Sling and the bed surface with the patient side facing up. Clinical judgment should be used when positioning wedges. Locate the sacrum and place one wedge below the sacrum. Position the other wedge, one hand’s width above the lower wedge, to support the upper body of the patient.

3. Lower the patient onto the wedges. Check wedge placement by placing your hand between the wedges, confirming the sacrum is not touching the bed. Raise the head of the bed as desired and recheck the sacrum. Raise the siderails or follow your facility’s protocol.

ReusableWedgeManual, Rev. A

www.HoverTechInternational.com | 5

Reusable Positioning Wedge User Manual

Limpeza e Mantemento Preventivo
REUSABLE POSITIONING WEDGE CLEANING INSTRUCTIONS
In between patient uses, the reusable wedge should be wiped down with a cleaning solution used by your hospital for medical equipment disinfection. A 10:1 bleach solution (10 parts water: one part bleach) or disinfectant wipes can also be used. NOTE: Cleaning with bleach solution may discolor fabric. First remove any visible soil, then clean the area according to the cleaning product manufacturer’s recommended dwell time and level of saturation. Allow to air dry before using.
Do not launder or place it in a dryer.

MANTEMENTO PREVENTIVO
Prior to use, a visual inspection should be performed on the wedge to ensure that there is no visible damage that would render it unusable. If any damage is found that would cause the wedge not to function as intended, the wedge should be removed from use and discarded.
CONTROL DE INFECCIÓNS
If the Reusable Wedge is used for an isolation patient, the hospital should employ the same protocols/procedures it utilizes for the bed mattress and/ or for linens in that patient room.
Cando un produto chega ao final da súa vida útil, debe separarse por tipo de material para que as pezas poidan ser recicladas ou eliminadas adecuadamente de acordo cos requisitos locais.

Transporte e almacenamento
Este produto non require condicións especiais de almacenamento.

6 | HoverTech

ReusableWedgeManual, Rev. A

Reusable Positioning Wedge User Manual
Devolucións e Reparacións
Todos os produtos que se devolvan a HoverTech deben ter un número de autorización de devolución de mercadorías (RGA) emitido pola empresa. Por favor, chame 800-471-2776 e pregunta por un membro do Equipo RGA que che emitirá un número RGA. Calquera produto devolto sen un número RGA provocará un atraso no tempo de reparación. Os produtos devoltos deben enviarse a:
HoverTech Attn: RGA # ___________ 4482 Innovation Way Allentown, PA 18109
Para obter garantías dos produtos, visite o noso websitio web: https://hovertechinternational.com/standard-product-warranty/
HoverTech 4482 Innovation Way Allentown, PA 18109 www.HovertechInternational.com Info@HovertechInternational.com These products comply with the standards applicable for Class 1 products in the Medical Device Regulation (EU) 2017/745 on medical devices.

ReusableWedgeManual, Rev. A

www.HoverTechInternational.com | 7

4482 Innovation Way Allentown, PA 18109
800.471.2776 Fax 610.694.9601
HoverTechInternational.com Info@HoverTechInternational.com