GOODWE - logoAparèy Sauvegarde Otomatik Seri MPD
Gid enstalasyon

GOODWE MPD Series Automatic Backup Device

ENSTRIKSYON SEKIRITE ENPÒTAN

SOVE ENSTRIKSYON SA YO
You shall follow all the safety precautions mentioned in this manual when working on the device.
Ikòn avètisman AVÈTISMAN
The product is designed and tested to strictly comply with related safety rules. Read and follow all the safety instructions and cautions before any operations. Improper operations might cause personal injury or property damage as the device is electrical equipment.
1.1 Hazard Level Definition
Yo defini diferan nivo mesaj avètisman nan manyèl sa a jan sa a:
Ikòn avètisman DANJE
Endike yon gwo danje ki, si yo pa evite, sa pral lakòz lanmò oswa blesi grav.
Ikòn avètisman AVÈTISMAN
Endike yon danje nan nivo mwayen ki, si yo pa evite, ka lakòz lanmò oswa blesi grav.
Ikòn avètisman ATANSYON
Endike yon danje ki ba-nivo ki, si yo pa evite, ta ka lakòz blesi minè oswa modere.
AVI
Highlights key information and supplements other text. It may include skills and methods to solve product-related problems.
1.2 Sekirite jeneral
AVI

  • The information in this manual is subject to change due to product updates or other reasons. This guide cannot replace the product labels or other safety precautions unless otherwise specified. All descriptions here are for guidance only.
  • Before installation, read through this manual to learn about the product and the precautions.
  • Tout operasyon yo ta dwe fèt pa teknisyen ki resevwa fòmasyon ak konesans ki abitye ak estanda lokal yo ak règleman sekirite yo.
  • Use insulating tools and wear personal protective equipment when operating the device to ensure personal safety. Wear anti-static gloves, cloths, and wrist strips when touching electronic devices to protect the device from damage.
  • Strictly follow the installation, operation, and configuration instructions in this manual. The manufacturer shall not be liable for device damage or personal injury if you do not follow the instructions. Visit https://en.goodwe.com to get more information about product warranty.

1.3 Sekirite Aparèy
Ikòn avètisman AVÈTISMAN
Vol latage ak frekans nan pwen an koneksyon ta dwe satisfè kondisyon yo sou-griyaj.
Make sure that the current rating of this product’s main breaker meets the specifications of the household power distribution unit.
The PE (equipment grounding) cable of the device must be connected firmly (1.6N·m).
For AC circuit connections, copper (CU) conductors are recommended.
Ikòn avètisman DANJE
All labels and warning marks should be visible after the installation. Do not scrawl on, damage, or cover any label on the device.
Unauthorized dismantling or modification may damage the equipment. Such action may damage the equipment and is not covered under the warranty. Warning labels on the device are as follows.

Icône Avètisman elektrik DANGER High voltage danje. Dekonekte tout pouvwa k ap rantre epi fèmen pwodwi a anvan ou travay sou li.
LG LW6024R Smart Wi Fi aktive èkondisyone fenèt - senbòl 4 Li nan manyèl itilizatè a anvan ou travay sou aparèy sa a.
AVTech BATR3CWWW Battery Light - Icon 3 Danje nan tanperati ki wo. Pa manyen pwodwi a anba operasyon pou evite boule.
WEE-Disposal-icon.png Do not dispose of the device as household waste. Discard the product in compliance with local laws and regulations, or send it back to the manufacturer.
GOODWE MPD Series Automatic Backup Device - icon Egzeyat reta. Rete tann 5 minit apre pouvwa koupe jiskaske eleman yo konplètman egzeyate.
avètisman - 1 Risk potansyèl egziste. Mete bon PPE anvan nenpòt operasyon.
HITACHI RAK-QJ18PCBST èkondisyone chanm - senbòl 1 Pwen baz.
GOODWE MPD Series Automatic Backup Device - icon 1 SGS certification mark.

1.4 Kondisyon Pèsonèl
AVI

  • Personnel who install or maintain the device must be strictly trained, learn about safety precautions and correct operations.
  • Se sèlman pwofesyonèl kalifye oswa pèsonèl ki resevwa fòmasyon ki gen dwa enstale, opere, kenbe ak ranplase aparèy la oswa pati yo.

Entwodiksyon pwodwi

2.1 Entwodiksyon pwodwi
Deskripsyon Fonksyon
The device transfers between on-grid mode and backup mode with an integrated switch.
The device connects the main panel, the utility grid, and the AC output of the inverter to form an on-grid system when the utility grid works normally. Once the utility grid fails, the device will connect loads and the AC output of the inverter only to form a backup system.
The ABD supports one inverter and the MPD supports up to three inverters. Model Description
This manual covers listed device below:
ABD Series

  • ABD200-40-US10
  • ABD200-63-US10
  • ABD100-40-US10
  • ABD100-63-US10

Seri MPD

  • MPD200-40-US10
  • MPD200-63-US10

Eksplikasyon Modèl
GOODWE MPD Series Automatic Backup Device - Model Explanation

Non. Siyifikasyon Deskripsyon
1 Pwodwi ABD: Automatic Backup Device MPD: Multi-inverter Parallel Device
2 Main breaker rating 200: Applies to the main service panel whose main breaker rating is smaller than or equal to 200A and larger than 100A.
100: Applies to the main service panel whose main breaker rating is smaller than or equal to 100A.
3 Protection current of the inverter breaker 40/63: The protection current of the inverter breaker is 40A or 63A, which matches with the following inverters:
Hybrid inverters: GW5000/6000/7600/9600/11K-ES-US20 AC-coupled inverters: GW5000/6000/7600/9600/11K-SBP-U520
4 Kòd rejyon an US: the U.S.
5 Generation code 10: generation 1.0

Supported Grid Type
The inverter supports 120/240V split phase grid type.GOODWE MPD Series Automatic Backup Device - Grid Type2.2 Senaryo aplikasyon
Add an ABD (Automatic Backup Device) in the system to realize the whole home backup. Once the utility grid fails, the ABD will disconnect the main service panel from the utility grid, and the inverter will switch to off-grid working mode to supply power to the loads.
2.2.1 Application Scenarios – ABD
• Whole Home Backup SystemGOODWE MPD Series Automatic Backup Device - Backup System

Microgrid SystemGOODWE MPD Series Automatic Backup Device - Microgrid System2.2.2 Application Scenarios – MPD

GOODWE MPD Series Automatic Backup Device - Application Scenarios - MPD2.3 Dyagram elektrik
2.3.1 Electrical Diagram – ABDGOODWE MPD Series Automatic Backup Device - Electrical Diagram2.3.2 Electrical Diagram – MPDGOODWE MPD Series Automatic Backup Device - Electrical Diagram - MPD2.4 Aparans
2.4.1 PatiGOODWE MPD Series Automatic Backup Device - Electrical Diagram - Appearance

Non. Pati Deskripsyon
1 Endikatè ki ap dirije Indicates the working status of the device.
2 Fèmen To lock the device’s door (key included).
3 Pandye bracket Hangs the device on the mounting support.
4 Smart mèt Contact after-sales service for support or replacement.
5 Izolasyon tablo Ensures personal safety and protects the device.
6 Brekè varyateur Provides overcurrent protection for the inverter.
Recommended specifications: 40A or 63A (or 60A when the ALT of the installation site is less than 2000m) Breaker, UL489 certified. ABD: 1 x inverter breaker. MPD: 3 x inverter breakers.
Aktyèl pwodwi ka varye.
7 Breaker prensipal This breaker is optional when the main panel is also equipped with a breaker. Provides overcurrent protection from utility grid.

2.4.2 DimansyonGOODWE MPD Series Automatic Backup Device - Dimensions2.4.3 Endikatè

Endikatè Estati Eksplikasyon
GOODWE MPD Series Automatic Backup Device - icon 2 GOODWE MPD Series Automatic Backup Device - icon 4 ON= The grid is abnormal and the system is in Back-up mode.
GOODWE MPD Series Automatic Backup Device - icon 5 BLINK = The grid is normal and the system is in On-grid mode.
GOODWE MPD Series Automatic Backup Device - icon 6 OFF = With no input source, the system is in waiting mode.
GOODWE MPD Series Automatic Backup Device - icon 3 GOODWE MPD Series Automatic Backup Device - icon 7 ON = The communication with the inverter is normal, and the 12V power supply from the inverter is normal.
GOODWE MPD Series Automatic Backup Device - icon 8 BLINK 1= The communication with the inverter is normal, and the 12V power supply from the inverter is abnormal.
GOODWE MPD Series Automatic Backup Device - icon 9 BLINK 2= The communication with the inverter is abnormal, and the 12V power supply from the inverter is normal.
GOODWE MPD Series Automatic Backup Device - icon 6 Off = The communication with the inverter is abnormal, and the 12V power supply from the inverter is abnormal.
avètisman 2 GOODWE MPD Series Automatic Backup Device - icon 10 On = Fault has occurred.
GOODWE MPD Series Automatic Backup Device - icon 6 Off = No fault.

2.5 Pwodwi yoGOODWE MPD Series Automatic Backup Device - DeliverablesAVI

  • N = Quantity depends on the device model.
  • The number of pin terminals and communication terminal are various depending on different devices. The actual accessories may differ.
  • The communication cable for parallel connection is only for MPD.

Enstalasyon

3.1 Kondisyon pou enstalasyon
Kondisyon anviwònman enstalasyonGOODWE MPD Series Automatic Backup Device - Installation RequirementsKondisyon ang enstalasyonGOODWE MPD Series Automatic Backup Device - 1

3.2 Enstalasyon aparèy
AVI

  • Evite tiyo dlo yo ak câbles antere nan miray la lè perçage twou.
  • Mete linèt ak yon mask pousyè pou anpeche pousyè a respire oswa kontakte je lè w ap fè twou.

Step 1 Put the mounting bracket on the wall or the support horizontally and mark positions for drilling holes.
Step 2 Drill holes to a depth of 80mm(3.15in) using the hammer drill. The diameter of the drill bit should be 10mm(0.39in).
Step 3 Secure the mounting bracket using the expansion bolts.
Step 4 Install the device on the mounting bracket.
Step 5 Screw to secure the device and the mounting bracket.GOODWE MPD Series Automatic Backup Device - mounting bracket

Koneksyon elektrik

4.1 Prekosyon Sekirite

avètisman 2 DANJE
ENSTRIKSYON KI KONSÈNÈ AK RISK POU DIFE OSWA CHÒK ELEKTRIK

  • Perform electrical connections, including operations, cables, and component specifications in compliance with local laws and regulations ANSI/NFPA 70.
  • The input and output circuits are isolated from the enclosure and that system grounding, if required by the National Electric Code, ANSI/NFPA 70, is the responsibility of the installer.
  • Power off the device before any electrical connections. Otherwise, an electric shock may occur.
  • Mare câbles yo nan menm kalite ansanm, epi mete câbles diferan kalite apa. Pa mete câbles yo anmele oswa kwaze.
  • If the tension is too large, the cable may be poorly connected. You have to reserve a certain length of the cable before connecting it to the device cable port. • Make sure that the cable conductor is in full contact with the terminal and the cable insulation part is not crimped with the terminal when crimping the terminal. Otherwise, the device may not be able to work properly, or the connection may be unreliable during working, which may cause terminal block damage, etc.

AVI

  • Koulè kab nan dokiman sa a se pou referans sèlman. Espesifikasyon kab yo dwe satisfè lwa ak règleman lokal yo.

4.2 Preparing Conductor Conduit & Fittings
4.2.1 Conduit Holes
AVÈTISMAN

  • Wiring conduits are additionally required, not included in the scope of delivery. The conduit must be UL514B listed and meet the specifications of the waterproof nut.
  • To avoid influencing the protection class or damaging the equipment, check the wiring conduit to make sure that the conduit is installed properly and the holes are sealed.

GOODWE MPD Series Automatic Backup Device - Conduit Holes

Conduit Hole Deskripsyon Konduit
AC Grid Install the wiring conduit and run Grid-L1, Grid-L2, and Neutral wire through the cable hole. 2 inch conduit
AC chaj Install the wiring conduit and run Load-L1, Load-L2, Neutral wire, and PE through the cable hole. 2 inch conduit
Inverter Install the wiring conduit and run Inverter-L1,
Inverter-L2, Neutral wire, PE cable, and communication cable through the cable hole.
1 inch conduit

4.2.2 Espesifikasyon fil elektrik

GOODWE MPD Series Automatic Backup Device - Wiring Specifications

Non. Pati Etikèt Deskripsyon
1. Inverter communication terminal Inverter COM •    Terminal for connecting the communication cable of the inverter.
•    Recommended specification: RJ45 cable, 24AWG, CAT5e or better.
2. CT terminal for solar inverter •    Terminal for connecting the CT for the solar inverter.
3. CT
4. Tèminal varyateur Inverter A-L1 / L2, Inverter B-L1 / L2, Inverter C-L1 / L2, Inverter-N •    Terminal for connecting the AC conductor of the inverter.
•    Inverter B and Inverter C are only for MPD series products.
•    Recommended specification: 6-8AWG, copper conductor, 90℃.
5. AC Grid terminal Grid-L1, Grid-L2, Grid-N •    Terminal for connecting the Grid conductor.
•    Recommended specification:
•  4/0AWG, copper conductor, 90℃ for ABD200- 40-US10, ABD200-63-US10, MPD200-40-US10, and MPD200-63-US10.
•  3AWG, copper conductor, 90℃ for ABD100-40- US10 and ABD100-63-US10.
6. AC Loads terminal Load-L1, Load-L2, Load-N •    Terminal for connecting the AC conductor of the load.
•    Recommended specification:
•  4/0AWG, copper conductor, 90℃ for ABD200- 40-US10, ABD200-63-US10, MPD200-40-US10, and MPD200-63-US10.
•  3AWG, copper conductor, 90℃ for ABD100-40- US10 and ABD100-63-US10.
7. Bay otobis la tè •    Busbar for connecting the PE cable.
•    Recommended specification:
•  Load-PE: 4-6AWG, copper conductor, 90℃.
•  Inverter-PE: 10AWG, copper conductor, 90℃.

4.3 Opening the Cabinet Door
Step 1 Unlock the cabinet door using the included key.
Step 2 Remove the six screws fixing the insulation board(torque: 0.8Nm).
Step 3 Remove the insulation board.GOODWE MPD Series Automatic Backup Device - Cabinet Door4.4 Connecting the Conductors
avètisman 2 AVÈTISMAN

  • Connect the conductors to the right terminals like L1, L2, and N. The device may be damaged if the conductors are connected inappropriately.
  • Make sure that the whole conductors are inserted into the terminal holes. No part of the conductor can be exposed.
  • Make sure that the conductors are connected securely. Otherwise, the terminal may get too hot and damage the device.

4.4.1 Connecting the AC Conductors (Grid)
avètisman 2 AVÈTISMAN
The ac output (neutral) is not bonded to ground.
Step 1 Strip the conductor wiring.
Step 2 Remove the waterproof cover using the included cap removal tool.
Step 3 Insert the desired conduit and corresponding adaptors, fittings, and bushings.
Step 4 Insert the conductors into the device and tighten the conduit.GOODWE MPD Series Automatic Backup Device - Conductors4.4.2 Connecting the AC Conductors (Load)
Step 1 Strip the conductor wiring.
Step 2 Remove the waterproof cover using the included cap removal tool.
Step 3 Insert the desired conduit and corresponding adaptors, fittings, and bushings.
Step 4 Insert the conductors into the device and tighten the conduit.GOODWE MPD Series Automatic Backup Device - Conductors 14.4.3 Connecting the AC Conductors (Inverter)
Step 1 Strip the conductor wiring, crimp the conductor with appropriate wire connector.
Step 2 Remove the waterproof cover using the included cap removal tool.
Step 3 Insert the desired conduit and corresponding adaptors, fittings, and bushings.
Step 4 Insert the conductors into the device and tighten the conduit.GOODWE MPD Series Automatic Backup Device - AC Conductors4.4.4 Konekte kab kominikasyon an
Step 1 Prepare a RJ45 network cable and insert it into the terminal.
Step 2 Run the cable through the cable clip and the conduit.GOODWE MPD Series Automatic Backup Device - Communication Cable4.4.5 Connecting the CT Cable (Optional)
AVI

  • Only for AC coupled inverters.

Etap 1 Clamp the CT around the cable to be measured.
Step 2 Insert the CT cable into the terminal block.
Kalite 1GOODWE MPD Series Automatic Backup Device - Type 1Kalite 2GOODWE MPD Series Automatic Backup Device - Type 24.5 Closing the Cabinet Door
Step 1 Install the insulation board.
Step 2 Tighten the six screws fix the insulation board (torque: 0.8Nm).
Step 3 Optional. Lock up the device using the cabinet key. Keep the key properly for future use.GOODWE MPD Series Automatic Backup Device - Cabinet Door

Ekipman komisyonin

5.1 Tcheke anvan limen

Non. Tcheke atik
1 The product is firmly installed at a clean place that is well-ventilated and easy-to- operate.
2 The PE, power, and communication cables are connected correctly and securely.
3 Lyen kab yo entak, wout byen ak respire.
4 Unused ports and terminals are fitted using the waterproof caps.
5 The insulation board is installed properly.
6 Vol latage and frequency at the connection point meet the grid connection requirements.
7 Twou kondit elektrik yo sele.

5.2 Power ON the Device
Step 1 Turn on the main breaker of the device.
Step 2 Turn on the inverter breaker of the device.

Antretyen

6.1 Power OFF the Device
avètisman 2 DANJE
ENSTRIKSYON KI KONSÈNÈ AK RISK POU DIFE OSWA CHÒK ELEKTRIK

  • Power off the device before operations and maintenance. Otherwise, the device may be damaged or electric shocks may occur.
  • Delayed discharge. Wait until the components are discharged and the LED indicators are off after power off.

Step 1 Turn off the main breaker of the device.
Step 2 Turn off the inverter breaker of the device.
Step 3 Turn off the breaker of the main panel.
Step 4 Power off the inverter.

6.2 Replacing the Inverter Breaker
avètisman 2 AVÈTISMAN

  • Make sure that the device is powered off.
  • Wear proper personal protective equipment before any operations.

Step 1 Loosen the screws and cables of the breaker.
Step 2 Pull the plastic slot under the breaker.
Step 3 Replace the breaker with a new one, the new breaker shall be AC40A or 63A(60A) and UL489 certified.
Step 4 Place the breaker properly and push the plastic slot. Make sure that the breaker is securely installed.
Step 5 Tighten the cables.

Paramèt teknik

7.1 ABD Series Technical Parameters

Done teknik ABD200- 40-US10 ABD200- 63-US10 ABD100- 40-US10 ABD100- 63-US10
Done elektrik
Nominal Sòti Voltage (V) 240
Sòti Voltage Range (V) 211 ~ 264
Feed-in Type Faz Split
Nominal AC Voltage of Line Conductor (V) 120/240
Frekans AC nominal (Hz) 60
AC Frequency Range (Hz) 58.5 ~ 61.2
Current Rating (From Grid)(A) 200
Max. Continuous Current From Inverter (A) 32 47.5 32 47.5
Maximum Overcurrent Protection of Main Breaker (A)*1 200 100
Maximum Overcurrent Protection of Circuit Breaker of Inverter (A) 40 63 40 63
Done Jeneral
Operating Temperature Range (℉) -13℉~+140℉ (-25℃~+60℃)*2
Max. Operating Altitude (ft) 9842 pye (3000m)
Metòd refwadisman Konveksyon natirèl
Kominikasyon ak varyateur RS485
Pwa (lb) 26lb (12kg)
Dimension (W×H×D in) 17.7 × 24 × 5.9 pous (450 × 610 × 150 mm)
Metòd aliye Mi monte
Evalyasyon Pwoteksyon Ingress Type 3R, IP44
Sètifikasyon
Règleman sekirite UL1741, CSA 22.2 No. 107-01
EMC FCC part15 CLASS B
*1: The main breaker is optional.
*2: Derating temperature: 113℉(45℃).

7.2 MPD Series Technical Parameters

Done teknik MPD200-40-US10 MPD200-63-US10
Done elektrik
Nominal Sòti Voltage (V) 240
Sòti Voltage Range (V) 211 ~ 264
Feed-in Type Faz Split
Nominal AC Voltage of Line Conductor (V) 120/240
Frekans AC nominal (Hz) 60
AC Frequency Range (Hz) 58.5 ~ 61.2
Current Rating (From Grid)(A) 200
Max. Continuous Current From Inverter (A) 32 47.5
Max. Amount of Inverters in Parallel 3
Maximum Overcurrent Protection of Main Breaker (A)*1 200
Maximum Overcurrent Protection of Circuit Breaker of Inverter (A) 40 63
Done Jeneral
Operating Temperature Range (℉) -13℉~+140℉ (-25℃~+60℃)*2
Max. Operating Altitude (ft) 9842 pye (3000m)
Metòd refwadisman Konveksyon natirèl
Kominikasyon ak varyateur RS485
Pwa (lb) 30lb (13.5kg)
Dimension (W×H×D in) 17.7 × 24 × 5.9 pous (450 × 610 × 150 mm)
Metòd aliye Mi monte
Evalyasyon Pwoteksyon Ingress Type 3R, IP44
Sètifikasyon
Règleman sekirite UL1741, CSA 22.2 No. 107-01
EMC FCC part15 CLASS B
*1: The main breaker is optional.
*2: Derating temperature: 113℉(45℃).

GOODWE MPD Series Automatic Backup Device - qr codehttps://en.goodwe.com/GOODWE MPD Series Automatic Backup Device - qr code 1https://en.goodwe.com/contact-us.aspGOODWE MPD Series Automatic Backup Device - qr code 2340-00797-04

GoodWe teknoloji co, Ltd.
GOODWE MPD Series Automatic Backup Device - icon 5 No 90 Zijin Rd., New District, Suzhou, 215011, Lachin
TVONE 1RK SPDR PWR Spider Power Modil - Icon 2 www.goodwe.com
TVONE 1RK SPDR PWR Spider Power Modil - Icon 3 service@goodwe.com

Dokiman / Resous

GOODWE MPD Series Automatic Backup Device [pdfGid Enstalasyon
ABD200-40-US10, ABD200-63-US10, ABD100-40-US10, ABD100-63-US10, MPD200-40-US10, MPD200-63-US10, MPD Series Automatic Backup Device, MPD Series, Automatic Backup Device, Backup Device

Referans

Kite yon kòmantè

Adrès imel ou p ap pibliye. Jaden obligatwa yo make *