- Specifications are subject to change without notice. The information in this document supersedes all previously supplied information before the effective date listed below. TMB has confidence in the accuracy of the document information herein but assumes no responsibility or liability for any loss occurring as a direct or indirect result of errors or exclusions whether by accident or any other cause.
The ProPlex CodeBridge is a member of our LTC Device system which is designed to generate, distribute and monitor timecode. Our rugged, compact mini-enclosure design is perfect for desktop programmers to throw in bag while also being flexible enough to install in a rack with an optional RackMount Kit. Drop a CodeBridge anywhere you need to share a fully synchronized timecode stream between multiple departments and other TMB LTC devices on the network.
CARATTERISTICHE PRINCIPALI
- Theoretically unlimited number of CodeBridges possible on the same network
- OLED control panel with intuitive user interface and LTC clock, oscilloscope, and level display
- Remote access and configuration via ProPlex Software GUI* or built-in web pagina
- Interface options include the ability to name and select between multiple CodeBridge sources*
- Two transformer-isolated XLR3 LTC outputs. Adjustable output level (-18dBu to +6dBu)
- Front panel status LEDs for Ethernet, MIDI and LTC
- Compact, lightweight, rugged, reliable. Backpack friendly
- Available rackmount kit options
- Redundant power – USB-C and PoE
*RTP MIDI, ProPlex Software functionality and naming and selecting of sources will be added in future firmware updates
CODICI ORDINE
PART NUMERI | PROUDCT NAME |
PPCODEBLME | PROPLEX CODEBRIDGE |
PP1RMKITSS | 1U RACKMOUNT KIT, SMALL, SINGLE |
PP1RMKITSD | 1U RACKMOUNT KIT, SMALL, DUAL |
PP1RMKITS+MD | PROPLEX 1U DUAL COMBINATION SMALL + MEDIUM |
MODEL OVERVIEW
FULL DIMENSIONAL WIREFRAME DRAWINGS
ISTITUISCI
Precauzioni di sicurità
Leghjite attentamente queste istruzioni.
This user guide contains important information about the installation, usage, and maintenance of this product
- Ensure the device is connected to proper voltage, è quella linea voltage is not higher than that stated in the device specifications
- Assicuratevi chì ùn ci sia micca materiali infiammabili vicinu à l'unità mentre travaglia
- Always use a safety cable when hanging fixture overhead
- Always disconnect from the power source before servicing or fuse replacement (if applicable)
- Maximum ambient temperature (Ta) is 40°C (104°F). Do not operate unit at temperatures above this rating
- In the event of a serious operating problem, stop using the unit immediately. Repairs must be carried out by trained, authorized personnel. Contact the nearest authorized technical assistance center. Only OEM spare parts should be used
- Do not connect the device to a dimmer pack
- Make sure power cord is never crimped or damaged
- Never disconnect power cord by pulling or tugging on the cord
ATTENZIONE! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please see the limited warranty information at the end of this document
DEBACKING
Upon receipt of the unit, carefully unpack the carton and check the contents to ensure that all parts are present and in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of mishandling. Save the carton and all packing materials. If a unit must be returned to the factory, it is important that it be returned in the original factory box and packing.
Ciò chì hè inclusu
- ProPlex CodeBridge
- Cavu USB-C
- Fermacavu clamp
- QR Code downloads card
REQUISITI POWER
The ProPlex CodeBridge has redundant power connections.
- Power the device via a USB-C cable connected to any standard 5 VDC wall charger or computer USB port
- Supply Power over Ethernet (PoE) by connecting the CodeBridge Ethernet port to any PoE enabled switch or injector.
In some cases, you may want to utilize both connections. Units powered via PoE allow access to the web browser via any computer connected to the same network. Additionally, all connected CodeBridge devices will share stream data via Ethernet. USB-C connections allow for MTC data communication as well as power-IN.
INSTALLAZIONE
The ProPlex CodeClock enclosure was designed with the touring programmer in mind. We wanted these devices to be lightweight, packable and stackable – so we fitted them with oversized rubber feet to keep them stationary on most surfaces These units are also compatible with Small RackMount Kits should they need to be semi-permanently mounted for touring applications
RACKMOUNT INSTALLATION INSTRUCTIONS
ProPlex RackMount Kits are available for both Single-Unit and Dual-Unit mounting configurations To fasten the rack ears or joiners to the ProPlex PortableMount chassis, you must remove the two chassis screws on each side at the front of the chassis. These same screws are used to securely fasten the RackMount ears and joiners to the chassis For dual-unit configurations, both sets of front and rear chassis screws will be used
IMPORTANTE : Be sure to reinsert the screws into the unit after ears have been removed. Store RackMount Kit in a safe location until needed again. Spare screws are available from TMB if needed
RACKMOUNT INSTALLATION INSTRUCTIONS
The Single-Unit Small RackMount Kit is comprised of two rack ears, ONE long and ONE short. The diagram below depicts the completed installation of the RackMount Kit. These rack ears are designed to be symmetrical, so that the short and long ears can be interchangeable
The Dual-Unit Small RackMount Kit has TWO short rack ears plus TWO joiners. The diagram below depicts the completed installation of the RackMount Kit. This configuration requires the TWO center joiners attached at both front and rear
INSTALLING THE DUAL JOINERS
The Dual-Unit Small RackMount Kit includes FOUR joining links and FOUR countersunk flat head screws. These links are designed to nest into each other and are secured with the included screws and threaded holes. Each link piece is identical. Simply rotate the joining link and line up the installation holes to install on either the left or right side of the corresponding unit.
OPERAZIONE
The ProPlex CodeBride can be easily configured with the onboard OLED Display and navigation buttons on the front of the unit
SCREEN HOME
The CodeBridge has 3 separate HOME SCREENS that display different parameters of incoming timecode streams. Cycle between these screens by pressing either the buttone
- Scherma di casa 1
The incoming LTC IN stream is displayed at the top of the screen while the bottom area shows oscillogram and voltage level bar to indicate signal level from the LTC source only
Note: Ideally the LTC IN steam should resemble a square wave with high output level. If level is too low, try increasing the volume at the source to improve the signal - Scherma di casa 2
This screen displays all sources of timecode that the CodeBridge can detect
The topmost source is the current active source which is retransmitted further from output connections. Whichever source is active will be highlighted with a blinking background
Scherma di casa 3
The third screen displays format information on all detected streams Like Home Screen 2, the top-most source is the current active source which is retransmitted further from output connections. Whichever source is active will be highlighted with a blinking background
Menu principale
The Main Menu can be accessed by pressing the button and majority of options can be exited via the button Scroll with the
button and confirm selection with the
buttone.
Nota: Not all menus will fit on the device screen so you will need to scroll to access some menus. The right side of most menu screens will will display a scroll bar which will help indicate the depth of scroll navigation
Generatore di Timecode
The CodeBridge can generate clean, high output LTC out of the two isolated XLR3 ports (located on the rear of each unit)
Aduprà u button, then confirm selection with the
button to cycle between the various generator options
- Format: Select between different industry standard FPS rates 23.976, 24, 25, 29.97ND, 29.97DF, and 30 FPS. If the selected format is compatible with MTC or Art-Net timecode, it will also be transmitted through that respective interface port (MIDI OUT or Ethernet ports)
- Start Time: Specify a start time of HH:MM:SS:FF using navigation buttons
- User Data: Specify user data in 0x00000000 hex format
- Play, Pause, Rewind: User playback controls for generated timecode.
Nota: you must remain on this screen to continuously use the LTC generator. If you exit this screen, the generator will stop automatically, and the current source will change over to the next active source
Livellu di output
Boost or cut the output level from +6 dBu to -12 dBu. Everything outputting via the two isolated XLR3 ports is affected by this level change.
Questu include:
- A pruduzzioni di u generatore
- Re-transmitted timecode formats from other inputs
Aduprà ubutton, then confirm selection with the
button to cycle between the various output levels. The asterisk indicator will denote the currently selected output level
Pre-roll Frames
- Pre-roll is the number of valid frames needed to consider the timecode source to be valid and begin forwarding it to the outputs
- Aduprà
the button to highlight the Pre-roll value, then press
button to edit
- Aduprà u
button to set the Pre-roll frames (1-30) and to save the value
Nota: The active stream display will always show incoming LTC stream starting from the 1st received frame regardless of Pre-roll settings
Post-roll Frames
- Post-roll frames help correct erroneous or dropped frames in a timecode source
- When a stream is stopped for any reason, the transmission will continue until a count equivalent to the Post-roll frames setting is reached
- If an erratic source issue resolved within the Post-roll window, the device will continue streaming timecode without interruption
- Use the button to highlight the Post-roll value, then press button to edit. Use to select a value place in HH:MM:SS:FF format
- Press button to edit each value as needed, using or to change the count. Press after editing to save each value and repeat to edit the next.
Indirizzu IP
- View
set the IP Address and Netmask of the unit
Note: This is the address used to access the CodeBridge Web Browser. This is mainly used to monitor and update each unit with future firmware releases - Use the button to highlight, then press
button to edit either IP Address or Netmask
- Aduprà
to select a value in x.x.x.x format. Press to edit, using
to change each value and again to save. Repeat to edit each octet
Nome di u dispusitivu
Create a custom name for the device
Backspace
Change to UPPERCASE
Move u cursore
- 123 Number editor
- – Add a space
- Aduprà
to select and highlight an editing tool or a letter, then press
per cunfirmà a selezzione
- Highlight the 123 menu and press
to input a numerical character.
- Aduprà
to select 0-9 and press
again to confirm selection and type the character in the name field
- When name editing is complete, highlight OK and press
per salvà è surtite
Informazioni di u dispusitivu
Device Info displays status information of the unit. The information displayed is:
- Nome di u dispusitivu
- Indirizzu IP
- NetMask
- Indirizzu MAC
Press per esce
L'infurmazione di u firmware
Firmware Info displays status information of the unit. The information displayed is
- Numero di versione
- Data di custruzzione
- Custruì u tempu
Press
per esce
MAPPA MENU
INDICATORI DI STATU LED
MIDl IN:
Receives timecode
Receives data which is not timecode
MIDl OUT:
Transmits timecode from source
Transmits timecode, postroll is running
Transmits data which is not timecode
LTC IN:
Receives timecode, but 1 second has not passed without errors or jumps in timecode
Receives timecode without jumps or errors for more than 1 second
Timecode was received, but is not received at the moment
LTC OUT:
Transmits timecode, postroll is running
Transmits timecode, internal generator is running
Transmits timecode for more than 1 second
Transmits timecode, but 1 second has not passed from start of transmission
WEB Navigatore
Any networked computer can access the CodeBridge Web Browser
Locate the IP address of the unit (instructions above) then type the IP address into the address bar of your favorite browser. You should be presented with the following landing page:
Note: computer or laptop should be in the same network range – 2.X.X.X
AGGIORNAMENTI FIRMWARE
Occasionally we will release firmware updates that contain new features or bug fixes. Firmware for all ProPlex units is available via the TMB Cloud
A link to TMB Cloud is under the Resources menu on our main websitu https://tmb.com/
To update, download the new firmware.bin file to your desktop. Then upload through the “Firmware Upgrade” menu via the Web Browser
PULIZIA E MANUTENZIONE
Dust build-up in connector ports can cause performance issues and can potentially lead to further damage during normal wear and tear CodeClock devices need occasional cleaning to maintain best performance, especially units used in harsher environmental conditions
THE FOLLOWING ARE GENERAL CLEANING GUIDELINES:
- Always disconnect from power before attempting any cleaning
- Wait until unit has cooled and discharged completely before cleaning
- Use vacuum or dry compressed air to remove dust/debris in and around connectors
- Use a soft towel or brush to wipe and buff the chassis body
- To clean the navigation screen, apply isopropyl alcohol with a soft lens cleaning tissue or lint free cotton
- Alcohol pads and q-tips may help remove any grime and residue from navigation buttons
IMPORTANTE:
Be sure all surfaces are dry before attempting to power on again
SPECIFICAZIONI TECNICHE
Part Number | PPCODEBLME |
Connettore di putenza | USB-C |
Ethernet (& PoE in) Connector | Neutrik EtherCON™ RJ45 |
MIDI Input Connector | DIN 5-Pin Female |
MIDI Output Connector | DIN 5-Pin Female |
LTC Input Connector | Neutrik™ Combination 3-Pin XLR and 1/4” TRS female |
LTC Output Connectors | Neutrik™ 3-Pin XLR Male |
Voltage | 5 VDC USB-C or 48 VDC PoE |
Cunsumu d'energia | TBA |
Température d'opération. | TBA |
Dimensioni (HxLxP) | 1.72 x 7.22 x 4.42 in [43.7 x 183.5 x 112.3 mm] |
Pesu | 1.2 lbs. [0.54 kg] |
Pesu di spedizione | 1.4 lbs. [0.64 kg] |
INFORMAZIONI SULLA GARANTIA LIMITATA
I Dispositivi di Distribuzione di Dati ProPlex sò garantiti da TMB contr'à i materiali difettusi o a manuvra per un periudu di dui (2) anni da a data di vendita originale da TMB. La garantie de TMB sera limitée à la réparation ou au remplacement de toute pièce qui s'avère défectueuse et pour laquelle une réclamation est soumise à TMB avant l'expiration des périodes de garantie applicables.
Questa Garanzia Limitata hè nulla se i difetti di u Produttu sò u risultatu di:
- Apertura di a carcassa, a riparazione o l'aghjustamentu da una persona diversa da TMB o persone specificamente autorizate da TMB
- Accident, abusu fisicu, mishandling, o misapplication di u pruduttu.
- Dannu per fulmini, terremoti, inundazioni, terrurismu, guerra o attu di Diu.
TMB will not assume responsibility for any labor expended, or materials used, to replace and/or repair the Product without TMB’s prior written authorization. Any repair of the Product in the field, and any associated labor charges, must be authorized in advance by TMB. Freight costs on warranty repairs are split 50/50: Customer pays to ship defective product to TMB; TMB pays to ship repaired product, ground freight, back to Customer. This warranty does not cover consequential damages or costs of any kind.
A Return Merchandise Authorization (RMA) Number must be obtained from TMB prior to return of any defective merchandise for warranty or non-warranty repair. For repair enquiries, please contact TMB via email at TechSupport@tmb.com or phone at either of our locations below:
TMB US
- 527 Park Ave.
- San Fernando, CA 91340
- Stati Uniti
- Tel: +1 818.899.8818
- TMB UK
- 21 Armstrong Way
- Southall, UB2 4SD
Inghilterra
- Tel: +44 (0)20.8574.9700
- You may also contact TMB directly via
- email à TechSupport@tmb.com
PROCEDURA DI RITORNU
Please contact TMB and request a repair ticket and Return Merchandise Authorization Number prior to shipping items for repair. Be prepared to provide the model number, serial number, and a brief description of the cause for the return as well as the return shipping address and contact information. Once a repair ticket has been processed, the RMA # and return instructions will be sent via email to the contact on file.
Clearly label any shipping package(s) with ATTN: RMA#. Please return equipment prepaid and in the original packaging whenever possible. DO NOT include cables or accessories (unless advised otherwise). If original packaging is not available, be sure to properly pack and protect any equipment. TMB is not liable for any shipping damage resulting from inadequate packaging by the sender. Freight call tags will not be issued for shipping repairs to TMB, but TMB will pay the freight for return to the customer if the repair qualifies for warranty service. Non-warranty repairs will undergo a quotation process by the technician assigned to the repair. All associated costs for parts, labor and return shipping must be authorized in writing before any work can be completed. TMB reserves the right to use its own discretion to repair or replace product(s) and determine the warranty status of any equipment.
INFORMAZIONI DI CONTATTO
SEDE DI LOS ANGELES
527 Park Avenue | San Fernando, CA 91340, USA
- Tel: +1 818.899.8818
- Fax: + 1 818.899.8813 sales@tmb.com
- TMB SUPPORT TECH 24/7
- Stati Uniti / Canada: +1.818.794.1286
- Toll Free: 1.877.862.3833 (1.877.TMB.DUDE)
- UK: +44 (0)20.8574.9739
- Toll Free: 0800.652.5418 techsupport@tmb.com
- TMB SUPPORT TECH 24/7
Stati Uniti / Canada: +1.818.794.1286
Toll Free: 1.877.862.3833 (1.877.TMB.DUDE) - UK: +44 (0)20.8574.9739
- Toll Free: 0800.652.5418
- techsupport@tmb.com
Una sucietà di serviziu cumpletu chì furnisce supportu tecnicu, serviziu à i clienti è seguitu.
Providing products and services for the industrial, entertainment, architectural, installation, defense, broadcast, research, telecommunications, and signage industries. Los Angeles, London, New York, Toronto, Riga and Beijing.
Effective 11 July 2025. © Copyright 2025, TMB. All rights reserved
FAQ
Q: Are spare screws available for the RackMount Kit?
A: Yes, spare screws are available from TMB if needed. Contact customer support for assistance with spare parts.
Documenti / Risorse
![]() |
ProPlex CodeBridge TimeCode Or Midi Over Ethernet [pdfManuale d'usu CodeBridge TimeCode Or Midi Over Ethernet, CodeBridge, TimeCode Or Midi Over Ethernet, Midi Over Ethernet, Over Ethernet, Ethernet |