daviteq LogoLevel Indicating
Controller LFC128-2
FA'A'OA'OGA FA'A'OA'O MO LE VAEGA FA'A'OA'O LE PULE LFC128-2
LFC128-2-MN-EN-01 JUN-2020

LFC128-2 Fa'atonu Fa'aaliga Tulaga Maualuga

O lenei pepa e fa'aoga mo oloa nei

SKU LFC128-2 HW Ver. 1.0 FW Ver. 1.1
Fa'ailoga o mea LFC128-2 Pule Fa'ailoga La'asaga, 4AI/DI, 4DI, 4xRelay, 1xPulse Output, 2 x RS485/ModbusRTU-Slave Feso'otaiga

Galuega Suiga Log

HW Ver. FW Ver. Aso Fa'asalalau Galuega Suiga
1.0 1.1 IUNI-2020

Folasaga

LFC128-2 o se faʻaaliga maualuga maualuga faʻaalia. O le oloa e tuʻufaʻatasia le Modbus RTU faʻaoga e fesoasoani ai i le PLC / SCADA / BMS ma soʻo se IoT port e mafai ona faʻafesoʻotaʻi e mataʻituina. LFC128-2 o loʻo i ai se mamanu faigofie ae mamana ma 4 AI / DI, 4 DI, 4 Relays, 1 Pulse pulse output, 2 RS485 Slave ModbusRTU faʻatagaina i latou e faʻafesoʻotaʻi ma le tele o masini faigofie. Faʻatasi ai ma tekonolosi faʻapitoa e maua ai le mautu maualuga ma le faʻamaoni, tele o galuega, faʻapipiʻi faigofie ma le paʻi paʻi ma le faʻafeiloaʻiga faʻafeiloaʻi fesoasoani vaʻaia mataʻituina tulaga.

daviteq LFC128 2 Advanced Level Display Controller

Fa'amatalaga

Fa'afuainumera Fa'aulu 04 x Ports, opto-coupler, 4.7 kohms input resisrtance, 5000V rms isolation, Logic 0 (0-1VDC), Logic 1 (5-24VDC), Functions: logic status 0/1 or Pulse counting (32 bit counter with max 4kHz pulse)
Faʻaaigoa Faʻamatalaga 04 x Ports, select between 0-10VDC input or 0-20mA input, 12 bit Resolution, can be configured as Digital input by DIP switch (max 10VDC input) The AI1 port is a 0-10 VDC / 4-20 mA level sensor connection port
Fa'asologa o Galuega 04 x Ports, electro-mechanical Relays, SPDT, contact rating 24VDC/2A or 250VAC/5A, LED indicators
Uaua Galuega Faatino 01 x Ports, open-collector, opto-isolation, max 10mA and 80VDC, On/off control, Pulser (max 2.5Khz, max 65535 Pulses) or PWM (max 2.5Khz)
Fesootaiga 02 x ModbusRTU-Slave, RS485, saoasaoa 9600 poʻo le 19200, faʻailoga LED
Toe seti faamau For resetting 02 x RS485 Slave port to default setting (9600, None parity, 8 bit)
Ituaiga mata Pa'i lau
Paoa sapalai 9..36VDC
Fa'atauga 200mA @ 24VDC sapalai
Ituaiga fa'apipi'i Mauga laupapa
Tigaina poloka pitch 5.0mm, fua faatatau 300VAC, tele uaea 12-24AWG
Galulue vevela/sūsū 0..60 degC / 95%RH e le fa'asa'o
Fua H93xW138xD45
mamafa mama 390 kalama

Ata o oloa

daviteq LFC128 2 Advanced Level Display Controller  - Picturesdaviteq LFC128 2 Advanced Level Display Controller  - Pictures 1

Fa'atinoga Fa'avae

daviteq LFC128 2 Advanced Level Display Controller  - Pictures 2

5.1 fesoʻotaʻiga Modbus

daviteq LFC128 2 Advanced Level Display Controller  - communication

02 x RS485/ModbusRTU-Slave
Maliega: Modbus RTU
tuatusi: 1 – 247, 0 is the Broadcast address
Fuafuaga o le Baud: 9600, 19200
Tutusa: leai se tasi, ese, tutusa

  • LED fa'ailoga tulaga:
  • Led on: modbus communication OK
  • Led blinking: received data but modbus communication incorrect, due to wrong Modbus configuration: address, baudrate
  • Led off: LFC128-2 received no data, check the connection

Memmap resitala
FAITAU faʻaaoga le poloaiga 03, TUSI faʻaaoga le poloaiga 16
Fa'atonuga masani:

  • Tuatusi: 1
  • Baudrate slave 1: 9600
  • Parity slave 1: none
  • Baudrate slave 2: 9600
  • Parity slave 2: none
Modbus Resitala Hex adr # of registersdaviteq LFC128 2 Advanced Level Display Controller  - Icon Fa'amatalaga Avanoa Fa'atonu Fa'asologa Meatotino Faamatalaga
0 0 2 fa'amatalaga masini LFC1 manoa Faitau
8 8 1 DI1       DI2: digital status 0-1 uint8 Faitau H_byte: DI1 L_byte: DI2
9 9 1 DI3       DI4: digital status 0-1 uint8 Faitau H_byte: DI3 L_byte: DI4
10 A 1 AI1      AI2: digital status 0-1 uint8 Faitau H_byte: AI1 L_byte: AI2
11 B 1 AI3      AI4: digital status 0-1 uint8 Faitau H_byte: AI3 L_byte: AI4
12 C 1 AI1: tau analog uint16 Faitau
13 D 1 AI2: tau analog uint16 Faitau
14 E 1 AI3: tau analog uint16 Faitau
15 F 1 AI4: tau analog uint16 Faitau
16 10 2 AI1: fua fa'atatau opeopea Faitau
18 12 2 AI2: fua fa'atatau opeopea Faitau
20 14 2 AI3: fua fa'atatau opeopea Faitau
22 16 2 AI4: fua fa'atatau opeopea Faitau
24 18 1 ta'avale 1 0-1 uint16 Faitau
25 19 1 ta'avale 2 0-1 uint16 Faitau
26 1A 1 ta'avale 3 0-1 uint16 Faitau
27 1B 1 ta'avale 4 0-1 uint16 Faitau
28 1C 1 tatala le aoina ctrl 0-3 uint16 Faitau/Tusi 0: pa'u 1: luga 2: pwm, fa'aauau pea 3: pa'u, pe a lava le numera o fatu, ctrl = 0
30 1E 2 counter DI1 uint32 Faitau/Tusi e mafai ona tusi, tapeina
32 20 2 counter DI2 uint32 Faitau/Tusi e mafai ona tusi, tapeina
34 22 2 counter DI3 uint32 Faitau/Tusi e mafai ona tusi, tapeina
36 24 2 counter DI4 uint32 Faitau/Tusi e mafai ona tusi, tapeina
38 26 2 fa'atau AI1 uint32 Faitau/Tusi counter writable, erasable, max frequency 10Hz
40 28 2 fa'atau AI2 uint32 Faitau/Tusi counter writable, erasable, max frequency 10Hz
42 2A 2 fa'atau AI3 uint32 Faitau/Tusi counter writable, erasable, max frequency 10Hz
44 2C 2 fa'atau AI4 uint32 Faitau/Tusi counter writable, erasable, max frequency 10Hz
46 2E 2 DI1: time on uint32 Faitau/Tusi sec
48 30 2 DI2: time on uint32 Faitau/Tusi sec
50 32 2 DI3: time on uint32 Faitau/Tusi sec
52 34 2 DI4: time on uint32 Faitau/Tusi sec
54 36 2 AI1: time on uint32 Faitau/Tusi sec
56 38 2 AI2: time on uint32 Faitau/Tusi sec
58 3A 2 AI3: time on uint32 Faitau/Tusi sec
60 3C 2 AI4: time on uint32 Faitau/Tusi sec
62 3E 2 DI1: time off uint32 Faitau/Tusi sec
64 40 2 DI2: time off uint32 Faitau/Tusi sec
66 42 2 DI3: time off uint32 Faitau/Tusi sec
68 44 2 DI4: time off uint32 Faitau/Tusi sec
70 46 2 AI1: time off uint32 Faitau/Tusi sec
72 48 2 AI2: time off uint32 Faitau/Tusi sec
74 4A 2 AI3: time off uint32 Faitau/Tusi sec
76 4C 2 AI4: time off uint32 Faitau/Tusi sec
128 80 2 counter DI1 uint32 Faitau e le mafai ona tusi, tape
130 82 2 counter DI2 uint32 Faitau e le mafai ona tusi, tape
132 84 2 counter DI3 uint32 Faitau e le mafai ona tusi, tape
134 86 2 counter DI4 uint32 Faitau e le mafai ona tusi, tape
136 88 2 fa'atau AI1 uint32 Faitau e le mafai e le fata ona tusi, tape; maualuga ole taimi ole 10Hz
138 8A 2 fa'atau AI2 uint32 Faitau e le mafai e le fata ona tusi, tape; maualuga ole taimi ole 10Hz
140 8C 2 fa'atau AI3 uint32 Faitau e le mafai e le fata ona tusi, tape; maualuga ole taimi ole 10Hz
142 8E 2 fa'atau AI4 uint32 Faitau e le mafai e le fata ona tusi, tape; maualuga ole taimi ole 10Hz
256 100 1 modbus tuatusi pologa 1-247 1 uint16 Faitau/Tusidaviteq LFC128 2 Advanced Level Display Controller  - Icon
257 101 1 modbus baudrate pologa 1 0-1 0 uint16 Faitau/Tusidaviteq LFC128 2 Advanced Level Display Controller  - Icon 0: 9600, 1: 19200
258 102 1 modbus parity pologa 1 0-2 0 uint16 Faitau/Tusidaviteq LFC128 2 Advanced Level Display Controller  - Icon 0: leai, 1: ese, 2: tutusa

5.2 Toe Seti Ki
When holding the reset button for 4 seconds, LFC 128-2 will reset the default configuration to 02 x RS485 / Modbus
RTU-Slave.
Fa'atonuga ole Modbus RTU:

  • Tuatusi: 1
  • Fua Faatatau: 9600
  • Parity: leai

5.3 Masini faʻaaogaina

daviteq LFC128 2 Advanced Level Display Controller  - Digital Input

Fa'amatalaga:

  • 04 channels DI, isolated
  • Input Resistance: 4.7 kΏ
  • Tuʻua Voltagu: 5000Vrms
  • Logic level 0: 0-1V
  • Logic level 1: 5-24V
  • Galuega:
  • Read logic 0/1
  • Pusa Fa'atau

5.3.1 Faitau le tulaga talafeagai 0/1
Taua fa'atatau ile Modbus Memory Map: 0-1
Lesitala e teu ai mea taua i le Modbus Memory Map:

  • DI1__DI2: digital status: stores the logical state of channel 1 and channel 2.
    H_byte: DI1
    L_byte: DI2
  • DI3__DI4: digital status: store the logical state of channel 3 and channel 4.
    H_byte: DI3
    L_byte: DI4

5.3.2 Fa'atauta'i Pusa
Counter value i Modbus Memory Map, pe a faʻaopoopo le numera e sili atu i le faʻailoga, o le a otometi lava ona toe foʻi mai: 0 4294967295 (32bits)
E le mafai ona tapeina le tusi resitala o lo'o teuina le tau o le Counter i le Modbus Memory Map:

  • Counter DI1: teu le tulaga o le ala 1
  • Counter DI2: teu le tulaga o le ala 2
  • Counter DI3: store the logic state of channel 3
  • Counter DI4: teu le tulaga o le ala 4
    E le mafai ona tapeina le tusi resitala o lo'o teuina le tau o le Counter i le Modbus Memory Map:
  • None reset counter DI1: stores the logic state of channel 1
  • None reset counter DI2: stores the logic state of channel 2
  • None reset counter DI3: stores the logic state of channel 3
  • None reset counter DI4: stores the logic state of channel 4

Pulse Counter Mode:
Low-speed pulse count less than 10Hz with filter, anti-jamming:

  • Set register “counter DI1: filter time” = 500-2000: Channel 1 counts pulses less than 10Hz
  • Set register “counter DI2: filter time” = 500-2000: Channel 2 counts pulses less than 10Hz
  • Set register “counter DI3: filter time” = 500-2000: Channel 3 counts pulses less than 10Hz
  • Set register “counter DI4: filter time” = 500-2000: Channel 4 counts pulses less than 10Hz
  • High-speed pulse count with max 2KHz frequency without filter:
  • Set register “counter DI1: filter time” = 1: channel 1 counts pulses with Fmax = 2kHz
  • Set register “counter DI2: filter time” = 1: channel 2 counts pulses with Fmax = 2kHz
  • Set register “counter DI3: filter time” = 1: channel 3 counts pulses with Fmax = 2kHz
  • Set register “counter DI4: filter time” = 1: channel 4 counts pulses with Fmax = 2kHz

5.4 Tulaga Fa'atusa

daviteq LFC128 2 Advanced Level Display Controller  - Analog Input

04 AI alalaupapa, leai se fa'aesea (AI1 o se 4-20mA / 0-5 VDC / 0-10 VDC tulaga fa'aoga masini)

daviteq LFC128 2 Advanced Level Display Controller  - Analog Input 1

Fa'aaoga le DIP SW e fa'atulaga le fa'aoga Analog: 0-10V, 0-20mA

daviteq LFC128 2 Advanced Level Display Controller  - Analog Input 2

Taua Type of AI
0 0-10 V
1 0-20 mA

Ituaiga fa'aofi:

  • Fua voltagu: 0-10V
  • Measure current: 0-20mA
  • The configuration for AI reads the same logical state as DI, but it is not isolated with a pulse range of 0-24V

Fa'alavelave fa'aoga:

  • Fua voltage: 320 kΏ
  • Measure the current: 499 Ώ

5.4.1 Faitau le tau Analog
I'uga 12 bits
Le fa'asologa: 0.1%
Tau fa'atusa ile Modbus Memory Map: 0-3900
Lesitala tau tutusa i le Modbus Memory Map:

  • AI1 analog value: store the Analog value of channel 1
  • AI2 analog value: stores the Analog value of channel 2
  • AI3 analog value: store the Analog value of channel 3
  • AI4 analog value: store the Analog value of channel 4

5.4.2 AI fa'atulagaina e galue e pei o le DI
Leai se faaesea
AI Fa'atonu AI e faitau le tulaga tutusa e pei o le DI ma le pulupulu ampeletise mai le 0-24V
E i ai le 2 fa'asagatau fa'ata'ita'iga AIx: fa'aigoa fa'atatau 0 ma fa'asaga AIx: fa'ailoga fa'ailoga 1 i le laulau modbus: 0-4095

  • Analog Analog value of AI <counter AIx: threshold logic 0: is considered Logic 0 status of AI
  • Analog Analog value of AI> counter AIx: threshold logic 1: is considered to be Logic 1 state of AI
  • Counter AIx: threshold logic 0 = <Analog value of AI <= counter AIx: threshold logic 1: is considered to be the constant logic state

Logic Fa'atatau tulaga talafeagai o AI i Modbus Memory Map laulau: 0-1
O le tusi resitala o lo'o teuina fa'atatau i le Modbus Memory Map:

  • AI1___AI2: digital status: stores the logical state of channel 1 and channel 2.
    H_byte: AI1
    L_byte: AI2
  • AI3___AI4: digital status: stores the logical state of channel 1 and channel 2.
    H_byte: AI3
    L_byte: AI4

5.4.3 Fa'ataula'i Pusa AI max 10Hz
Counter value i Modbus Memory Map, pe a faʻaopoopo le numera i tua atu o le faitotoʻa, o le a otometi lava ona toe foʻi mai: 0 4294967295 (32bits)
E le mafai ona tapeina le tusi resitala o lo'o teuina le tau o le Counter i le Modbus Memory Map:

  • Counter AI1: stores the logic state of channel 1
  • Counter AI2: save logic state of channel 2
  • Counter AI3: save logic state of channel 3
  • Counter AI4: save logic state of channel 4
    E le mafai ona tapeina le tusi resitala o lo'o teuina le tau o le Counter i le Modbus Memory Map:
  • None reset counter AI1: stores the logic state of channel 1
  • None reset counter AI2: stores the logic state of channel 2
  • None reset counter AI3: stores the logic state of channel 3
  • None reset counter AI4: save logic state of channel 4

5.5 Fa'auiga

daviteq LFC128 2 Advanced Level Display Controller  - Relay

04 channel Relay SPDT NO / NC
Contact rating: 2A / 24VDC, 0.5A / 220VAC
There are status LEDs:

  • Led on: Close Contact
  • Led off: Open Contact
Tusi Resitala Relay Fa'aletonu Status of relays when resetting power supplies
3 Operate according to the Alarm configuration

Fa'ailoga Fa'ailoga:

  • HIHI : Relay 4 On
  • HI : Relay 3 On
  • LO : Relay 2 On
  • LOLO: Relay 1 On

5.6 Pusa Fa'aoso

daviteq LFC128 2 Advanced Level Display Controller  - Output

01 isolated open-collector channel
Opto-coupler: Source current Imax = 10mA, Vceo = 80V
Galuega: On / Off, pulse generator, PWM
5.6.1 Fa'aola/Ofo Galuega
Set the Open-collector register in the Modbus Memory Map table:

  • Set Open-collector register: 1 => Pulse Output ON
  • Set Open-collector register: 0 => Pulse Output OFF

5.6.2 Pulse generator
Fa'atosina fa'aulu fa'asalalauina le maualuga ole 65535 pulus, fa'atasi ai ma le Fmax 2.5kHz
Fa'atulaga tusi resitala nei i le Modbus Memory Map table:

  • Set register “open collector: pulse number”: 0-65535 => Pulse Number = 65535: broadcast 65535 pulses
  • Set register “open collector: time cycle”: (0-65535) x0.1ms => Time Cycle = 4: Fmax 2.5kHz
  • Set register “open collector: time on”: (0-65535) x0.1ms => Time On: is the logic time 1 of the pulse
  • Set the register “open collector ctrl” = 3 => configure the Pulse Output to generate a pulse and start to pulse, generate a sufficient number of pulses in the “open collector: pulse number” register => stop pulse generator and register ” open collector ctrl ”= 0

5.6.3 PWM
Ole tele ole taimi ole 2.5kHz
Fa'atulaga tusi resitala nei i le Modbus Memory Map table:

  • Set the register “open collector ctrl” = 2 => configure Pulse Output PWM function
  • Set register “open collector: time cycle”: (0-65535) x0.1ms => Time Cycle = 4: Fmax 2.5kHz
  • Set register “open collector: time on”: (0-65535) x0.1ms => Time On: is the logic time 1 of the pulse

Fa'apipi'i

6.1 Fa'apipi'i auala

daviteq LFC128 2 Advanced Level Display Controller  - method6.2 Uaea fa'atasi ai ma le Fa'aigoa Tulaga

daviteq LFC128 2 Advanced Level Display Controller  - method 1

Fa'atonuga

7.1 Fale o le Fale

daviteq LFC128 2 Advanced Level Display Controller  - Home Screen

VAILA: Switch to 2nd screen with more detailed information
AALAGI: Show Level Alert
FALE: Toe fo'i i le mata'ifale
CONFIG. (Default Password: a): Go to Setting Screen
7.2 Fa'atulaga le lau (Fa'amatalaga Fa'asinomaga: a)
7.2.1 Ata 1

daviteq LFC128 2 Advanced Level Display Controller  - Home Screen 1] '

ADCs: Raw signal value of channel AI1
Level (Unit): The level corresponds to the ADC signal after configuration
Decimal Places Level:Decimal number of digits after the dot of Level 0-3 (00000, 1111.1, 222.22, 33.333)
Unit level: level units, 0-3 (0: mm, 1: cm, 2: m, 3: inch)
I le 1: Enter the ADC value after putting 4 mA / 0 VDC into AI1 for calibration at 0 level
Fua 1: The level value displayed corresponds to the value entered in In 1 (usually 0)
I le 2: Enter the ADC value after putting 20 mA / 10 VDC into AI1 for calibration at Full level
Fua 2: The level value displayed corresponds to the value entered in In 2
Span Level: Maximum value of Level (Span Level ≥ Scale 2)
Decimal Places Volume: Decimal number of digits after the dot of Volume 0-3 (00000, 1111.1, 222.22, 33.333)
Unit Volume: units of volume 0-3 (0: lit, 1: cm, 2: m3, 3:%)
7.2.2 Ata 2

daviteq LFC128 2 Advanced Level Display Controller  - Home Screen 2

Level Hi Hi Set point (Unit): High High level of Alarm Level
Level Hi Hi Hys (Unit): High High level hysteresis of Alarm Level
Level Hi Set point (Unit): High level of Alarm Level
Level Hi Hys (Unit): High level hysteresis of Alarm Level
Level Lo Set point (Unit): Low level of Alarm Level
Level Lo Hys (Unit): Low level hysteresis of Alarm Level
Level Lo Lo Set point (Unit): Low Low level of Alarm Level
Level Lo Lo Hys (Unit): Low Low level hysteresis of Alarm Level
Ala atuatuvale: 0: Level, 1: Volume
Span Volume(Unit): Maximum value of the volume
7.2.3 Ata 3

daviteq LFC128 2 Advanced Level Display Controller  - Home Screen 3

Volume Hi Hi Set point (Unit): High High volume of Alarm Volume
Volume Hi Hi Hys (Unit): High High volume hysteresis of Alarm Volume
Volume Hi Set point (Unit): High volume of Alarm Volume
Volume Hi Hys (Unit): High volume hysteresis of Alarm Volume
Volume Lo Set point (Unit): Low volume of Alarm Volume
Volume Lo Hys (Unit): Low volume hysteresis of Alarm Volume
Volume Lo Lo Set point (Unit): Low Low volume of Alarm Volume
Volume Lo Lo Hys (Unit): Low Low volume hysteresis of Alarm Volume
Run Total: Run the total function. 0-1 (0: No 1: Yes)
7.2.4 Ata 4

daviteq LFC128 2 Advanced Level Display Controller  - Home Screen 4

Filling (Unit): Total function: total put into tank
Consumption (Unit): Total function: total consumption of the tank
Decimal Places Total: Decimal number of parameters Filling, Consumption, NRT Filling, NRT Consumption on display page (not the setting page)
Delta Total (Unit): Hysteresis level of the total function
Tuatusi Modbus: Modbus address of LFC128-2, 1-247
Modbus Baurate S1: 0-1 (0 : 9600 , 1 : 19200)
Modbus Parity S1: 0-2 (0: none, 1: odd, 2: even)
Modbus Baurate S2: 0-1 (0 : 9600 , 1 : 19200)
Modbus Parity S2: 0-2 (0: none, 1: odd, 2: even)
Num of Points: Number of points in the table to convert from level to volume, 1-166
7.2.5 Ata 5

daviteq LFC128 2 Advanced Level Display Controller  - Home Screen 5

Point 1 Level (Level Unit): Level at Point 1
Point 1 Volume (Volume Unit): The corresponding volume at Point 1
Point 166 Level (Level Unit): Fuel level at Point 166
Point 166 Volume (Volume Unit): The corresponding volume at Point 166
7.2.6 Ata 6

daviteq LFC128 2 Advanced Level Display Controller  - Home Screen 6

Numera e le iloa e sesi: Password to enter the Setting page, 8 ASCII characters
Tank Name: Tank name displayed on the main screen

Fa'afitauli

Leai. Fa'ailoga Mafuaaga Tali
1 Modbus ua le mafai ona fesootai Modbus LED Status: LED is off: received no data LED is blinking: the Modbus configuration is not the correct Siaki le fesoʻotaʻiga Siaki le faʻatulagaina o Modbus: tuatusi, Baud Rate, Parity
2 Taimi taimi Modbus Ua aliali mai le pisa i luga o le laina Fa'atulaga le Baudrate 9600 ma fa'aoga se uaea fa'alua fa'alua fa'atasi ai ma le puipuiga o le fa'alavelave
3 Ua motusia le masini Sensor ma LFC128 leiloa feso'ota'iga Checking connection Check sensor type (LFC128-2 only connects to 0-10VDC / 4- 20mA analog sensor type) Check the switch to see if it is turned on correctly Check that the sensor connector is correct AI1
4 Sese laulau laina laina Sese o le laulau liliu mai le tulaga i le voluma Siaki le faʻatulagaina o le laulau liliu mai le maualuga i le voluma

Lagolago feso'ota'iga

Tufuga
Daviteq Technologies Inc
No.11 Street 2G, Nam Hung Vuong Res., An Lac Ward, Binh Tan Dist., Ho Chi Minh City, Vietnam.
Tel: +84-28-6268.2523/4 (ext.122)
imeli: info@daviteq.com
www.daviteq.com

Pepa / Punaoa

daviteq LFC128-2 Faʻatonu Faʻaaliga Maualuga Maualuga [pdf] Tusi Taiala
LFC128-2, LFC128-2 Fa'atonu Fa'aaliga Fa'apitoa, Fa'atonu Fa'aaliga Fa'apitoa, Pule Fa'aaliga Fa'aaliga, Pule Fa'aaliga

Fa'asinomaga

Tuu se faamatalaga

E le fa'asalalauina lau tuatusi imeli. Fa'ailogaina fanua mana'omia *