ENGO EFAN-24 PWM желдеткич ылдамдыгын көзөмөлдөйт
Техникалык шарттар
- Протокол: MODBUS RTU
- Контроллердин модели: EFAN-24
- Байланыш интерфейси: RS485
- Дарек диапазону: 1-247
- Маалыматтын көлөмү: 32-бит
Продукт колдонуу нускамалары
- Configuration of the EFAN-24 controller must be carried out by a qualified person with appropriate authorization and technical knowledge, following country and EU standards and regulations.
- Failure to adhere to instructions may void the manufacturer’s responsibility.
- The controller can operate as a slave in a MODBUS RTU network with specific features and communication requirements. Ensure proper wiring configuration to avoid data corruption.
- Network Connection: RS-485 serial interface
- Data Configuration: Address, speed, and format are determined by hardware
- Data Access: Full access to the controller’s ladder program data
- Маалыматтын көлөмү: MODBUS маалымат реестрине 2 байт
- Before connecting the controller to the RS-485 network, ensure proper configuration of communication settings, including address, baud rate, parity, and stop bits.
- Unconfigured controllers should not be connected to the network to avoid operational issues.
Жалпы маалымат
MODBUS RTU жөнүндө жалпы маалымат
The MODBUS RTU structure uses a master-slave system to exchange messages. It allows a maximum of 247 slaves, but only one master. The master controls the operation of the network, and only it sends the request. Slaves do not undertake transmissions on their own. Each communication begins with the master requesting the Slave, which responds to the master with what it has been asked. The master (computer) communicates with slaves (controllers) in two-wire RS-485 mode. This uses data lines A+ and B- for data exchange, which MUST be one twisted pair.
Ар бир терминалга экиден ашык зымдарды туташтырууга болбойт, бул “Ромашка чынжырчасы” (сериялуу) же “түз сызык” (түз) конфигурациясын колдонууну камсыз кылат. Жылдыз же тармакка (ачык) туташуу сунушталбайт, анткени кабелдин ичиндеги чагылуулар маалыматтардын бузулушуна алып келиши мүмкүн.
Конфигурация
- Configuration must be carried out by a qualified person with the appropriate authorization and technical knowledge, following the standards and regulations of the country and the EU.
- The manufacturer will not be held responsible for any conduct not following the instructions.
КӨҢҮЛ:
There may be additional protection requirements for the entire installation and configuration, which the installer/programmer is responsible for maintaining.
MODBUS RTU тармагынын иштеши – Кул режими
Engo’s MODBUS controller has the following features when operating as a slave in a MODBUS RTU network:
- Network connection via RS-485 serial interface.
- Address, communication speed, and byte format are determined by hardware configuration.
- Баарына кирүү мүмкүнчүлүгүн берет tags and data used in the controller’s ladder program.
- 8 биттик кул дареги
- 32-бит маалымат өлчөмү (1 дарек = 32-бит маалымат кайтаруу)
- Each MODBUS data register has a size of 2 bytes.
КӨҢҮЛ:
- Before the controller is connected to the RS-485 network, it must first be properly configured.
- The communication settings are configured in the service parameters of the regulator (device).
КӨҢҮЛ:
- Connecting unconfigured controllers to the RS-485 network will result in improper operation.
- Автордук укук - Бул документ Engo Controls компаниясынын ачык уруксаты менен гана кайра чыгарылат жана таратылышы мүмкүн жана талап кылынган техникалык экспертизага ээ болгон ыйгарым укуктуу адамдарга же компанияларга гана берилиши мүмкүн.
байланыш орнотуулары
RS-485 байланыш орнотуулары
Pxx | Функция | Нарк | Description | Демейки баалуулук |
дар | MODBUS Slave түзмөгүнүн дареги (ID). | 1 – 247 | MODBUS Slave түзмөгүнүн дареги (ID). | 1 |
BAUD |
Бауд |
4800 |
Бит ылдамдыгы (Baud) |
9600 |
9600 | ||||
19200 | ||||
38400 | ||||
ПАРИ |
Паритет бит – каталарды аныктоо үчүн берилиштердин паритетин орнотот |
Жок | Жок |
Жок |
Ал тургай | Ал тургай | |||
Так | Так | |||
ТОКТОТ | StopBit | 1 | 1 аялдама бит | 1 |
2 | 2 аялдама бит |
Төмөнкү функция коддорун колдойт:
- 03 – reading n registers (Holding Registers)
- 04 – reading n registers (Input Registers)
- 06 – Write 1 register (Holding Register)
INPUT регистрлери – окуу үчүн гана
Дарек | Мүмкүнчүлүк | Description | Маани диапазону | билдирет | Демейки | |
декабрь | Hex | |||||
0 | 0x0000 | R (#03) | Engo MODBUS Model ID | 1-247 | MODBUS Slave (ID) | 1 |
1 | 0x0001 | R (#03) | Firmware-Version | 0x0001-0x9999 | 0x1110=1.1.10 (BCD коду) | |
2 |
0x0002 |
R (#03) |
Working-state |
0b00000010=Idle, switch OFF 0b00000000=Idle, room meet temperature 0b10000001=Heating 0b10001000=Cooling
0b00001000 = Idle, sensor error |
||
3 | 0x0003 | R (#03) | Интегралдык температура сенсорунун мааниси, °C | 50 – 500 | N-> температура = N/10 °C | |
5 |
0x0005 |
R (#03) |
Value of the External temperature sensor S1, °C |
50 – 500 |
0 = Open (sensor break)/ contact open
1 =Closed (sensor short circuit )/ contact closed N-> temp=N/10 °C |
|
6 |
0x0006 |
R (#03) |
Value of the External temperature sensor S2, °C |
50 – 500 |
0 = Open (sensor break)/ contact open
1 =Closed (sensor short circuit )/ contact closed N-> temp=N/10 °C |
|
7 |
0x0007 |
R (#03) |
Күйөрман абалы |
0b00000000 – 0b00001111 |
0b00000000= OFF
0b00000001= I Fan stage low 0b00000010= II Fan stage medium 0b00000100= III Fan state high 0b00001000= Auto – OFF 0b00001001= Auto – I low 0b00001010= Auto – II medium 0b00001100= Auto – III high |
|
8 | 0x0008 | R (#03) | Valve 1 stat | 0 – 1000 | 0 = OFF (valve closed)
1000 = ON / 100% (valve open) |
|
9 | 0x0009 | R (#03) | Valve 2 state | 0 – 1000 | 0 = OFF (valve closed)
1000 = ON / 100% (valve open) |
|
10 | 0x000A | R (#03) | Humidity measurement (with 5% indication accuracy) | 0 – 100 | N-> humidity=N % |
HOLDING регистрлери – окуу жана жазуу үчүн
Дарек | Мүмкүнчүлүк | Description | Маани диапазону | билдирет | Демейки | |
декабрь | Hex | |||||
0 | 0x0000 | R/W (#04) | Engo MODBUS Model ID | 1-247 | MODBUS Slave (ID) | 1 |
234 |
0x00EA |
R/W (#06) |
Fancoil түрү |
1 – 6 |
1 = 2 pipe – only heating 2 = 2 pipe – only cooling
3 = 2 pipe – heating & cooling 4 = 2 pipe – underfloor heating 5 = 4 pipe – heating & cooling 6 = 4 түтүк – полду жылытуу жана фанкойл менен муздатуу |
0 |
235 |
0x00EB |
R/W (#06) |
S1-COM киргизүү конфигурациясы (Орнотуучунун Параметрлери -P01) |
0 | Киргизүү жигердүү эмес. баскычтар менен жылытуу жана муздатуу ортосунда алмаштыруу. |
0 |
1 |
Input used to change heating/cooling via external contact connected to S1-COM:
– S1-COM open –> HEAT mode – S1-COM кыска –> COOL режими |
|||||
2 |
Input used to AUTOMATICALLY change heating/cooling based on PIPE TEMPERATURE in a 2-pipe system.
Контроллер жылытуу ортосунда которулат жана P17 жана P18 параметрлеринде белгиленген түтүктүн температурасына негизделген муздатуу режимдери. |
|||||
3 |
Allow fan operation dependent on the temperature measurement on the pipe. For example, if the temperature on the pipe is too low, and the controller is in heating mode
– The pipe sensor will not allow the fan to run. The change of heating/cooling is done manually, using the buttons. Values for fan control based on pipe temperature are set in parameters P17 and P18. |
|||||
4 | Полду жылытуу конфигурациясында полдун сенсорун активдештирүү. | |||||
236 |
0x00EC |
R/W (#06) |
S2-COM киргизүү конфигурациясы (Орнотуучунун Параметрлери -P02) |
0 | Киргизүү өчүрүлгөн |
0 |
1 | Ээлик сенсор (байланыштар ачылганда, ЭКО режимин иштетиңиз) | |||||
2 | Тышкы температура сенсору | |||||
237 |
0x00ED |
R/W (#06) |
Тандалган ЭКО режими (Орнотуучунун Параметрлери -P07) | 0 | NO – Disabled |
0 |
1 | YES – Active | |||||
238 | 0x00EE | R/W (#06) | ЭКО режиминин жылытуу температурасынын мааниси (Орнотуучунун параметрлери -P08) | 50 – 450 | N-> температура = N/10 °C | 150 |
239 | 0x00EF | R/W (#06) | Муздатуу үчүн ЭКО режиминин температурасынын мааниси (Орнотуучунун параметрлери -P09) | 50 – 450 | N-> температура = N/10 °C | 300 |
240 |
0x00F0 |
R/W (#06) |
ΔT of 0- 10V valve operation
This parameter is responsible for the modulated 0- 10V output of the valve. – In heating mode: If the room temperature drops, the valve opens proportionally to the delta size. – In cooling mode: If the room temperature increases, the valve opens in proportion to the size of the delta. The valve opening starts from the room set temperature. (Installer parameters -P17) |
1-20 |
N-> температура = N/10 °C |
10 |
241 |
0x00F1 |
R/W (#06) |
Жылытуу үчүн температура күйгүзүлгөн желдеткич
The fan will start working if the temperature in the room drops below the preset by the value of the parameter (Installer parameters -P15) |
0 – 50 |
N-> температура = N/10 °C |
50 |
Дарек | Мүмкүнчүлүк | Description | Маани диапазону | билдирет | Демейки | |||
декабрь | Hex | |||||||
242 |
0x00F2 |
R/W (#06) |
Башкаруу алгоритми
(TPI or hysteresis) for the heating valve (Installer parameters -P18) |
0 – 20 |
0 = TPI
1 = ±0,1C 2 = ±0,2C… N-> temp=N/10 °C (±0,1…±2C) |
5 |
||
243 |
0x00F3 |
R/W (#06) |
FAN delta algorithm for cooling
The parameter determines the width of the temperature range in which the fan operates in cooling mode. If the room temperature increases, then: 1. When a small value of Delta FAN, the faster the response of the fan to a change in temperature temperature – faster the increase in speed.
2. When large value of Delta FAN, the slower fan increases speed. (Орноткучтун параметрлери -P16) |
5 – 50 |
N-> температура = N/10 °C |
20 |
||
244 |
0x00F4 |
R/W (#06) |
Муздатуу үчүн температураны күйгүзүңүз.
The fan will start working if the temperature in the room rises above the setpoint by the value of the parameter. (Installer parameters -P19) |
0 – 50 |
N-> температура = N/10 °C |
50 |
||
245 | 0x00F5 | R/W (#06) | Муздатуу клапанынын гистерезис мааниси (Орнотуучунун параметрлери -P20) | 1 – 20 | N-> temp=N/10 °C (±0,1…±2C) | 5 | ||
246 |
0x00F6 |
R/W (#06) |
Жылытуу/муздатууну которуунун өлүк зонасы
In a 4-pipe system.The difference between the Set temperature and the room temperature, at which the controller will automatically change the heating/cooling operation mode. (Орноткучтун параметрлери -P21) |
5 – 50 |
N-> температура = N/10 °C |
20 |
||
247 |
0x00F7 |
R/W (#06) |
Жылытуудан муздатууга өтүүчү температуранын мааниси
– 2 түтүктүү система. In a 2-pipe system, below this value, the system switches to cooling mode and allows the fan to start. (Installer parameters -P22) |
270 – 400 |
N-> температура = N/10 °C |
300 |
||
248 |
0x00F8 |
R/W (#06) |
The value of the switching temperature from cooling to heating, 2-pipe system.
In a 2-pipe system, above this value, the system switches to heating mode and allows the fan to start. (Installer parameters -P23) |
100 – 250 |
N-> температура = N/10 °C |
100 |
||
249 |
0x00F9 |
R/W (#06) |
Муздатуу АЧУУ кечигүү.
A parameter used in 4-pipe systems with automatic switching between heating and cooling. This avoids too frequent switching between heating and cooling modes and oscillation of the room temperature. (Installer parameters -P24) |
0 – 15 мүн |
0 |
|||
250 |
0x00FA |
R/W (#06) |
Полдун максималдуу температурасы
To protect the floor, heating will be turned off when the floor sensor temperature rises above the maximum value. (Орноткучтун параметрлери -P25) |
50 – 450 |
N-> температура = N/10 °C |
350 |
||
251 |
0x00FB |
R/W (#06) |
Минималдуу полдун температурасы
To protect the floor, heating will be switched on, when the floor sensor temperature drops below the minimum value. (Installer parameters -P26) |
50 – 450 |
N-> температура = N/10 °C |
150 |
||
254 | 0x00FE | R/W (#06) | Орноткучтун жөндөөлөрү үчүн PIN код (Орнотуучунун Параметрлери -P28) | 0 – 1 | 0 = өчүрүлгөн
1 = PIN (First default code 0000) |
0 |
Дарек | Мүмкүнчүлүк | Description | Маани диапазону | билдирет | Демейки | |
декабрь | Hex | |||||
255 | 0x00FF | R/W (#06) | Requiring a PIN code to unlock the keys (Installer Parameters -P29) | 0 – 1 | 0 = NIE
1 = TAK |
0 |
256 |
0x0100 |
R/W (#06) |
Fan operation (Installer parameters -FAN) |
0 – 1 |
0 = NO – Inactive – output contacts for fan control are completely disabled
1 = Ооба |
1 |
257 | 0x0101 | R/W (#06) | Күйгүзүү/өчүрүү – жөнгө салгычты өчүрүү | 0,1 | 0 = ӨЧҮК
1 = ON |
1 |
258 |
0x0102 |
R/W (#06) |
Иштөө режими |
0,1,3 |
0=Manual 1=Schedule
3=FROST – anti-freeze mode |
0 |
260 |
0x0104 |
R/W (#06) |
Желдетүүчү ылдамдыкты жөндөө |
0b000000= OFF – fan off 0b00000001= I (low) fan gear 0b000010= II (medium) fan gear 0b00000100= III (high) fan gear
0b00001000= Automatic fan speed – OFF 0b00001001= Automatic fan speed – 1st gear 0b00001010= Automatic fan speed – 2nd gear 0b00001100= Automatic fan speed – 3rd gear |
||
262 | 0x0106 | R/W (#06) | ачкыч кулпу | 0,1 | 0=кулпусу ачылган 1=кулпуланган | 0 |
263 | 0x0107 | R/W (#06) | Дисплей жарыктыгы (Орнотуучунун Параметрлери -P27) | 0-100 | N-> Жарыктык =N% | 30 |
268 | 0x010C | R/W (#06) | Clock – minutes | 0-59 | Мүнөттөр | 0 |
269 | 0x010D | R/W (#06) | Clock – hours | 0-23 | Саат | 0 |
270 | 0x010E | R/W (#06) | Clock – Day of the week (1=Monday) | 1~7 | Аптанын күнү | 3 |
273 | 0x0111 | R/W (#06) | Set the temperature in schedule mode | 50-450 | N-> температура = N/10 °C | 210 |
274 | 0x0112 | R/W (#06) | Set temperature in manual mode | 50-450 | N-> температура = N/10 °C | 210 |
275 | 0x0113 | R/W (#06) | Set the temperature in FROST mode | 50 | N-> температура = N/10 °C | 50 |
279 | 0x0117 | R/W (#06) | Максималдуу коюлган температура | 50-450 | N-> температура = N/10 °C | 350 |
280 | 0x0118 | R/W (#06) | Минималдуу коюлган температура | 50-450 | N-> температура = N/10 °C | 50 |
284 | 0x011C | R/W (#06) | Accuracy of displayed temperature | 1, 5 | N-> температура = N/10 °C | 1 |
285 | 0x011D | R/W (#06) | Көрсөтүлгөн температураны оңдоо | -3.0… 3.0°C | in steps of 0.5 | 0 |
288 | 0x0120 | R/W (#06) | Selection of system type – heating/cooling (dependent on the setting of input S1) | 0,1 | 0 = Жылытуу
1 = Муздатуу |
0 |
291 | 0x0123 | R/W (#06) | Minimum fan speed (Installer Parameters-P10) | 0-100 | N-> ылдамдык = N % | 10 |
292 | 0x0124 | R/W (#06) | Maximum fan speed (Installer Parameters-P11) | 0-100 | N-> ылдамдык = N % | 90 |
293 | 0x0125 | R/W (#06) | Speed of fan 1st gear in manual mode (Installer parameters-P12) | 0-100 | N-> ылдамдык = N % | 30 |
294 | 0x0126 | R/W (#06) | Speed of fan 2nd gear in manual mode (Installer parameters-P13) | 0-100 | N-> ылдамдык = N % | 60 |
295 | 0x0127 | R/W (#06) | Speed of fan 3rd gear in manual mode (Installer parameters-P14) | 0-100 | N-> ылдамдык = N % | 90 |
Көп берилүүчү суроолор
- Q: What are the default communication settings for the EFAN-24 controller?
- A: The default settings include a slave device address of 1, the baud rate of 9600, no parity bit, and one stop bit.
- Q: How can I access different data registers in the MODBUS RTU network?
- A: Use the appropriate function codes such as #03 for reading holding registers or #06 for writing a single register. Each register has specific data values related to controller parameters.
Документтер / Ресурстар
![]() |
ENGO EFAN-24 PWM желдеткич ылдамдыгын көзөмөлдөйт [pdf] Instruction Manual EFAN-230B, EFAN-230W, EFAN-24 PWM желдеткич ылдамдыгын контроллери, EFAN-24, PWM желдеткич ылдамдыгын контроллер, желдеткич ылдамдыгын контроллер, ылдамдыкты контроллер |