AXIOMATIC AX020710 Single Sorti Valv Kontwolè Manyèl Itilizatè
AXIOMATIC AX020710 Single Sorti Valv Kontwolè

Kontni kache

SOUVIEW KONTWÒLÈ

Description of Universal Input to Proportional Valve Output NFC Controller
Manyèl Itilizatè sa a dekri achitekti ak fonksyonalite Inivèsèl Antre nan Kontwolè Valv Selibatè Sorti ak Near Field Communication (NFC). Tout antre ak blòk fonksyon lojik sou inite a se natirèlman endepandan youn ak lòt men yo ka konfigirasyon pou kominike youn ak lòt.

All parameters are configurable using the mobile E-Write NFC configuration tool available on the Google Play Store and Apple App Store. E-Write NFC allows the user to configure the module as well as to assign each of the AX020710 controllers a unique alias to easily distinguish between the controllers within a large system.

Teknoloji NFC kontwolè a bay itilizatè yo kapasite pou yo konfigirasyon kontwolè yo san yo pa bezwen limen. Karakteristik sa a pwouve itil espesyalman nan ka, pou egzanpample, nan ki inite a enstale nan yon sistèm ki mande akor epi li pa bezwen izole nan sistèm nan ak mache sou deyò pou fè akor la; olye de sa inite a ka configuré ak sistèm nan koupe.

The controller (1IN-1OUT-NFC) is designed for versatile control of a universal input and a proportional valve output. The hardware design allows for the controller to have a wide range of input and output types. The control algorithms/function blocks allow the user to configure the controller for a wide range of applications without the need for custom firmware. The various function blocks supported by the 1IN-1OUT-NFC are outlined in the following sectioris.

D' inivèsèl kapab être configuré pou li analòg siyal: Voltage, Kouran, ak Rezistans osi byen ke siyal dijital: Frekans / RPM, PWM, ak kalite dijital. Antre yo dekri an plis detay nan seksyon 1.2.

Menm jan an tou, pwodiksyon an ka configuré nan diferan kalite: Pwopòsyonèl aktyèl, Voltage, PWM, Hotshot Digital Current ak Digital (ON/OFF). Chak pwodiksyon konsiste de yon bò segondè chofè mwatye pon kapab sous jiska 3Amps ak fèmen pyès ki nan konpitè nan 4Amps. Yo dekri rezilta yo an plis detay nan seksyon 1.4.

Universal Input Function Block
Kontwolè a konsiste de yon sèl opinyon inivèsèl epi yo ka configuré pou mezire voltage, aktyèl, frekans / RPM, batman kè lajè modulation (PWM) ak siyal dijital. Sou-seksyon ki anba yo detaye karakteristik/fonksyonalite opinyon inivèsèl la.

Kalite Capteur Antre
Table 1 lists the supported input types by the controller. The Input Type parameter provides a dropdown list with the input types described in Table 1. Changing the Input Type affects other parameters within the same parameter group such as Minimum/Maximum Error/Range by refreshing them to new input type and thus should be changed first
Manyèl itilizatè UMAX020710 vèsyon 1.2

0 Non Itilize
1 Voltage -5V pou +5V
2 Voltage -10V pou +10V
3 Kouran 0 pou 20mA
4 Frekans 0.5 pou 50Hz
5 Frekans 10Hz pou 1kHz
6 Frekans 100Hz pou 10kHz
7 PWM Ba Frekans (<1kHz)
8 PWM Segondè Frekans (>100Hz)
9 Digital (Nòmal)
10 Digital (Inverse)
11 Digital (Latched)

Tablo 1 - Opsyon Kalite Capteur Antre Inivèsèl

Tout antre analòg yo manje dirèkteman nan yon konvètisè analòg-dijital (ADC) 12-bit nan mikrokontwolè a. Tout voltagAntre e yo se gwo enpedans pandan y ap antre aktyèl yo sèvi ak yon rezistans 2490 pou mezire siyal la.

Frequency/RPM, and Pulse Width Modulated (PWM) Kalite Antre are connected to the microcontroller timers. Puls pou chak Revolisyon parameter is only taken into consideration when the Kalite Antre selected is one of the frequency types as per Table 1. When Pulses per Revolution parameter is set to 0, the measurements taken will be in units of [Hz]. If Pulses per Revolution parameter is set to higher than 0, the measurements taken will be in units of [RPM].

Digital Kalite Antre offers three modes: Normal, Inverse, and Latched. The measurements taken with digital input types are 1 (ON) or 0 (OFF).

1.2.2. Opsyon Rezistans Pullup / Pulldown
Avèk Kalite Antre: Frekans/RPM, PWM, Digital, itilizatè a gen opsyon pou twa (3) opsyon diferan rale moute/rale desann jan yo endike nan Tablo 2.

0 Non Itilize
1 10kΩ Pullup
2 10kΩ deroulan

Tablo 2 - Opsyon Rezistans Pullup/Pulldown

These options can be enabled or disabled by adjust the parameter Pullup/Pulldown Resistor in
E-Write NFC

Minimum and Maximum Ranges

La Minimòm Range epi Maksimòm Range parameters are used to create the overall useful range of the inputs. For example, si Minimòm Range is set to 0.5V and Maksimòm Range is set to 4.5V, the overall useful range (0-100%) is between 0.5V to 4.5V. Anything below the Minimum Range will saturate at Minimum Range. Similarly, anything above the Maksimòm Range will saturate at Maximum Range.

Minimum and Maximum Errors
La Erè minimòm epi Maksimòm erè parameters are used when Deteksyon erè is True. When Deteksyon erè is enabled, any input measurement at or below/above the Minimum/Maximum Error parameters will create an input fault. When the input fault occurs, if the input is commanding the output, the output will shut off. The fault will be cleared as soon as the measured input is within Minimum Error+ or Maximum Error- the Error Hysteresis value. On the contrary, when Deteksyon erè se mete sou FALSE, no fault will occur and the Erè minimòm epi Maksimòm erè will not be taken into consideration.

Digital Debounce Tan
Paramèt sa a yo itilize nan Kalite Antre Digital (Nòmal), Digital (Envès) ak Digital (Latched). Li se tan an kontwolè a tann jiskaske pwosesis ak pwopagasyon eta a nan opinyon an lè yon kwen deklanche. Sa a ede filtre pouse-bouton oswa switch ki fè bwi yo nan lòd yo li yon siyal/eta pwòp.

Input Filter Types
Tout kalite opinyon eksepte Digital (Nòmal), Digital (Inverse), Digital (Latched) ka filtre lè l sèvi avèk Filter Type ak Filter Constant paramèt. Gen twa (3) kalite filtre ki disponib jan lis nan Tablo 3.

0 Non Itilize
1 K ap deplase Mwayèn
2 Repete Mwayèn

Tablo 3 - Kalite filtraj Antre

Premye opsyon filtre Pa gen filtraj, pa bay okenn filtraj done yo mezire. Kidonk done yo mezire yo pral dirèkteman itilize nan nenpòt blòk fonksyon ki sèvi ak done sa yo.

The second option, Moving Average, applies the ‘Equation 1’ below to measured input data, where Value N represents the current input measured data, while ValueN-1 represents the previous filtered data. The Filter Constant is the Input Filter Constant parameter.

Ekwasyon 1 – Fonksyon filtè an mwayèn k ap deplase:
Ekwasyon

The third option, Repeating Average, applies the ‘Equation 2’ below to measured input data, where N is the value of Input Filter Constant parameter. The filtered input, Value, is the average of all input measurements taken in N (Input Filter Constant) number of reads. When the average istaken, the filtered input will remain until the next average is ready.

Ekwasyon 2 – Repete Fonksyon Transfè Mwayèn:
Ekwasyon

Internal Function Block Control Sources
Kontwolè 1IN-1OUT-NFC a pèmèt sous entèn blòk fonksyon yo dwe chwazi nan lis la nan blòk fonksyon lojik yo sipòte pa kontwolè a. Kòm yon rezilta, nenpòt pwodiksyon nan yon blòk fonksyon ka chwazi kòm sous kontwòl pou yon lòt. Lis sous kontwòl yo montre nan Tablo 4.

Valè Siyifikasyon
0 Kontwòl Sous Non Itilize
2 Inivèsèl Antre Mezire
5 Chèche Tablo Fonksyon Blòk

Tablo 4 - Opsyon Sous Kontwòl

Anplis de yon sous, chak kontwòl tou gen yon nimewo ki koresponn ak sub-endèks blòk fonksyon an nan kesyon an. Tablo 5 prezante seri yo sipòte pou nimewo objè yo, tou depann de sous yo te chwazi a.

Kontwòl Sous Kontwòl Sous Nimewo
Control Source Not Used (Ignored) [0]
Inivèsèl Antre Mezire [1…1]
Lookup Table Function Block [1…1]

Tablo 5 – Opsyon Nimewo Sous Kontwòl

Analog source
Figi 1 - sous analogique D' Digital

Output Drive Function Blocks
Kontwolè a konsiste de yon sèl pwodiksyon pwopòsyonèl. Sòti a konsiste de yon bò segondè chofè mwatye pon ki kapab sous jiska 3Amps. Sòti yo konekte ak periferik revèy mikrokontwolè endepandan epi konsa yo ka konfigirasyon poukont yo soti nan 1Hz a 25kHz.

Paramèt Kalite Sòti a detèmine ki kalite siyal pwodiksyon an pwodui. Chanje paramèt sa a lakòz lòt paramèt nan gwoup la mete ajou pou matche ak kalite chwazi. Pou rezon sa a, premye paramèt ki ta dwe chanje anvan konfigirasyon lòt paramèt se paramèt Kalite Sòti a. Kalite pwodiksyon sipòte pa kontwolè a yo ki nan lis nan Tablo 6 anba a:

0 Andikape
1 Proportional Current
2 Digital Hotshot
3 Proportional Voltage (0-Vps)
4 PWM Duty Cycle
5 Digital (0-Vps)
There are two parameters that are associated to Proportional Current and Digital Hotshot Output Types that are not with others these are Dither Frequency and Dither Amplatitid. Se siyal la dither yo itilize nan mòd aktyèl pwopòsyonèl epi li se yon siyal frekans ba supèrpoz sou tèt siyal la frekans segondè (25kHz) kontwole aktyèl pwodiksyon an. De rezilta yo gen frekans dither endepandan ki ka ajiste nenpòt ki lè. Konbinezon an nan Dither AmpLitide ak Frekans Dither dwe byen chwazi pou asire repons rapid nan bobin nan ti chanjman nan entrées kontwòl yo men pa tèlman gwo kòm afekte presizyon oswa estabilite nan pwodiksyon an.
 Nan pwopòsyonèl Voltage type, the controller measures the Ves applied to the unit and based on this information, the controller will adjust the PWM duty cycle of the signal (0-Vps amplitude) so that the average signal is the commanded target value. Thus, the output signal is not an analog one. In order to create an analog signal, a simple low pass filter can be connected externally to the controller. Note: the output signal will saturate at Ves if the Output at Maximum Command is set higher than the supply voltage alimante kontwolè a.
 In PWM Duty Cycle Output Type, the controller outputs a signal (0-Ves amplitide) sou yon frekans pwodiksyon fiks ki tabli pa Frekans Sòti PWM ak varye Sik Devwa PWM ki baze sou opinyon kòmande. Depi tou de pwodiksyon yo konekte ak revèy endepandan, paramèt Frekans Sòti PWM a ka chanje nenpòt ki lè pou chak pwodiksyon san yo pa afekte lòt la.
 The Hotshot Digital type is different from Digital On/Off’ in that it still controls the current through the load. This type of output is used to turn on a coil then reduce the current so that the valve will remain open, as shown in Figure 3. Since less energy is used to keep the output engaged, this type of response is very useful to improve overall system efficiency. With this output type there are associated three parameters: Hold Current, Hotshot Current and Hotshot Time which are used to configure form of the output signal as shown in Figure 2.
Hotshot Digital Profile
Figure 2– Hotshot Digital Profile
 Pou pwodiksyon pwopòsyonèl siyal minimòm ak maksimòm valè yo configuré ak Sòti nan kòmand minimòm ak pèsistans yap ogmante jiska paramèt kòmand maksimòm. Ranje valè pou tou de paramèt yo limite pa Kalite Sòti yo chwazi.
Regardless of what type of control input is selected, the output will always respond in a linear fashion to changes in the input per ‘Equation 3’.
Ekwasyon
Ekwasyon 3 – Kalkil pant lineyè
Nan ka a nan blòk fonksyon lojik kontwòl pwodiksyon an, X ak Y yo defini kòm
Xmin = Kontwòl Antre Minimòm ; Ymin = Sòti nan lòd minimòm
Xmax = Kontwòl Antre Maksimòm; Ymax = Sòti nan kòmandman maksimòm
 In all cases, while X-axis has the constraint that Xmin Xmax, there is no such limitation on the Y-axis. Thus configuring Output At Minimum Command to be greater than Output At Maximum Command allows output to follow control signal inversely.
 Yo nan lòd yo anpeche chanjman toudenkou nan pwodiksyon an akòz chanjman toudenkou nan opinyon an lòd, itilizatè a ka chwazi yo sèvi ak endepandan leve oswa desann r.amps pou lise repons bobine a. Ramp Leve ak Ramp Paramèt desann yo an milisgond, epi yo pral detèmine gwosè etap chanjman pwodiksyon an lè w pran valè absoli seri pwodiksyon an epi divize li pa r la.amp tan.
 Paramèt Kontwòl Sous la ansanm ak paramèt Nimewo Kontwòl detèmine ki siyal yo itilize pou kondwi pwodiksyon an. Pou egzanpample, setting Control Source to Universal Input Measured and Control Number to (1) will connect signal measured from Universal Input1 to the output in question. The input signal is scaled per input type range between 0 and 1 to form control signal. Outputs respond in a linear fashion to changes in control signal. If a non-digital signal is selected lo drive digital output the command state will be 0 (OFF) at or below the “Output At Minimum Command, 1 (ON) at or above “Output At Maximum Command and will not change in between those points.
 Si yo detekte yon fay nan nenpòt nan opinyon aktif pwodiksyon an ap fèmen jiskaske opinyon an refè. Anplis defo yo antre fèmen pwodiksyon an, si yon anba-voltage/sou-voltage measurement occurs on Virs, the output will also shut down.
 The output is inherently protected against a short to GND or Virs by hardware. In case of a dead short, the hardware will automatically disable the output drive, regardless of what the processor is commanding for the output. When this happens, the processor detects output hardware shutdown and commands off the output in question. It will continue to drive non-shorted outputs normally and periodically try to re-engage the short load, if still commanded to do so. If the fault has gone away since the last time the output was engaged while shorted, the controller will automatically resume normal operation.
 Nan ka yon kous louvri, pa pral gen okenn entèripsyon nan kontwòl la pou nenpòt nan pwodiksyon yo. Processeur a ap kontinye eseye kondwi chaj la louvri.
 Blòk Fonksyon Tablo Lookup
Yo itilize Tablo Lookup la pou bay yon repons pwodiksyon ki rive jiska 5 pant. Gen de kalite repons Tablo Lookup ki baze sou Repons Tablo Lookup: Repons Done ak Repons Tan Seksyon 1.5.2 jiska 1.5.6 pral dekri de kalite Repons sa yo an plis detay.
 Lè Repons Tablo Rechèch la se Repons Done yo, valè pwen x aks X yo toujou an pousan.tage ki reflete percenttage nan Sous Kontwòl yo itilize nan Tablo Lookup la. Chanje Sous Kontwòl la pa pral chanje valè Pwen X-Axis x oswa Pwen X-Axis y.
 X-Axis, Input Data Response
Nan ka kote tip X-Axis = Done Repons, pwen yo sou X-Axis la reprezante done sous kontwòl la. Valè sa yo an pousantage (%) ak reprezante pousantage nan Sous Kontwòl yo chwazi a.
 Lè w ap chwazi valè done X-Axis, pa gen okenn kontrent sou valè ki ka antre nan nenpòt nan pwen X-Axis yo. Itilizatè a ta dwe antre valè nan ogmante lòd pou kapab itilize tout tab la. Se poutèt sa, lè w ap ajiste done X-Axis la, li rekòmande pou chanje X5 an premye, epi pi ba endèks yo nan lòd desandan pou kenbe sa ki anba a:
0% <= X_{0} <= X_{0} <= X_{1} <= X_{1} <= X_{2} <= X_{3} <= X_{4} <= X_{5} <= (100%)%
 Yo itilize tout pwen done yo. Si ou vle pa sèvi ak kèk nan pwen done yo, li rekòmande pou mete pwen done endezirab yo gen menm pousantaj.tage valè kòm dènye pwen done yo itilize.
 Y-Axis, Lookup Table Output
Aks Y a pa gen okenn kontrent sou done li reprezante yo. Sa vle di ke envès, oswa ogmante/diminye oswa lòt repons yo ka fasil etabli.
 Nan tout ka, kontwolè a gade tout seri done yo nan paramèt Y-Axis yo, epi li chwazi valè ki pi ba a kòm Ymin la ak valè ki pi wo a kòm Ymax la. Yo pase dirèkteman nan lòt blòk fonksyon kòm limit sou pwodiksyon Tab Lookup la. (sa vle di itilize kòm valè Xmin ak Xmax nan kalkil lineyè.)
 Default Configuration, Data Response
Pa defo, tab rechèch la enfim (Sous kontwòl tab rechèch la mete sou Kontwòl pa itilize). Ou ka itilize Tablo Lookup la pou kreye pro repons ou vle afiles. Lè yo itilize Antre Inivèsèl la kòm Sous Kontwòl, pwodiksyon Tablo Lookup la pral sa itilizatè a antre nan paramèt Y-Values.
 Sonje byen, nenpòt blòk fonksyon kontwole ki sèvi ak Tablo Lookup la kòm yon sous antre pral aplike tou yon linearizasyon nan done yo. Se poutèt sa, pou yon repons kontwòl 1:1, asire ke valè minimòm ak maksimòm pwodiksyon an koresponn ak valè minimòm ak maksimòm aks Y tab la.
 Pa default, done yo aks X ak Y yo konfigirasyon pou yon valè egal ant chak pwen soti nan minimòm nan maksimòm nan chak ka.
 Point To Point Response
Pa default, aks X ak Y yo konfigirasyon pou yon repons lineyè soti nan pwen (0,0) rive nan (5,5), kote pwodiksyon an pral itilize linearizasyon ant chak pwen. Figi 3 montre yon vèsyon pwolonje (10 pant) Tablo Lookup ki disponib nan 1IN-1OUT-NFC. Pou jwenn linearizasyon an, chak "Pwen N - Repons", kote N = 1 a 5, se konfigirasyon pou yon 'R.amp Pou' repons pwodiksyon.
Grafik
Figure 3- Lookup Table with “Ramp Pou” Done Repons
Alternatively, the user could select a ‘Jump To’ response for “Point N – Response”, where N = 1 to 5. In this case, the output of the Lookup Table will not change in between X-Axis Points rather it will only change when it is >X-Axis Point n and < X-Axis Point (n+1)
Yon konbinezon de Ramp Pou, Ale nan ak Ignore repons yo ka itilize yo kreye yon aplikasyon espesifik pwodiksyon profile.
X-Axis, Time Response
 As mentioned in Section 1.5, a Lookup Table can also be used to get a custom output response where the X-Axis Type is a ‘Time Response. When this is selected, the X-Axis now represents time, in units of milliseconds, while the Y-Axis still represents the output of the function block. There is also another parameter associated to the Lookup Table when configured to Time Response which is the Lookup Table Auto-Cycle parameter.
 Nan ka sa a, sous kontwòl la trete kòm yon opinyon dijital. Si siyal la se aktyèlman yon opinyon analòg, li entèprete tankou yon opinyon dijital pou chak Figi 1. Lè opinyon kontwòl la ON, pwodiksyon an pral chanje sou yon peryòd de tan ki baze sou pro a.file nan Tablo Lookup la. Gen de senaryo diferan sou fason tab rechèch la pral reyaji yon fwa pro afile fini. Opsyon nan premye se lè tab Auto-Cycle mete nan FALSE nan ka sa a, yon fwa pro afile te fini (sa vle di endèks 5), pwodiksyon an ap rete nan dènye pwodiksyon an nan fen pro afile jiskaske opinyon kontwòl la vire OFF. Dezyèm opsyon a se lè tab oto-sik mete sou VRE nan ka sa a, yon fwa pro afile fini (sa vle di endèks 5), Tablo Lookup la pral otomatikman retounen nan premye repons lan epi yo pral kontinye ap monte bisiklèt otomatikman pandan tout tan opinyon an rete nan eta ON.
 Lè opinyon kontwòl la OFF, pwodiksyon an toujou nan zewo. Lè opinyon an vini ON, pro afile TOUJOU starts at position (Xo, Yo) which is 0 output for Oms.
Nan yon repons tan, tan entèval ant chak pwen sou aks X la ka fikse nenpòt kote ant 1ms ak 1jou [86400 s]

Enstriksyon Enstalasyon

Dimansyon ak Pinout
Kontwolè 1IN-1OUT-NFC a se yon tablo PCB reyini ak yon gwo kouch konfòm pou pwoteksyon eleman kont vibrasyon ak lòt eleman. Asanble AX020710 la gen yon evalyasyon IP00, pandan y ap asanble AX020710-1.5M ak AX020710-PG9 yo genyen yon evalyasyon IP67.

WIREING TABLE
PIN# Koneksyon
1 Pouvwa
2 Pouvwa +
3 SOLENOID -
4 SOLENOID +
5 Antre +
6 Antre GND
7 Sòti oksilyè
8 +5V REFERENCE

Dimansyon Komisyon Konsèy
Dimansyon Komisyon Konsèy
Figure 4 – AX020710 Board Dimensions

WIREING TABLE
KOULÈ FIL FIL AWG KONEKSYON
NWA 18 POUVWA
WOUJ 18 POUVWA +
ORANGE/BLACK STRIPE 18 SOLENOID-
ORANGE/RED STRIPE 18 SOLENOID +
JÒN 24 Antre +
YELLOW/BLACK STRIPE 24 Antre GND
vyolèt 24 Sòti oksilyè
YELLOW/RED STRIPE 24 +5V REFERENCE

VALVE CONTROLLER
P/N: AX020710-1.5M
Tablo Inite

Dimansyon Komisyon Konsèy
Dimansyon Komisyon Konsèy

Figure 5 – AX020710-1.5M Board Dimensions

WIREING TABLE
PIN# Koneksyon
1 Pouvwa
2 Pouvwa +
3 SOLENOID -
4 SOLENOID +
5 Antre +
6 Antre GND
7 Sòti oksilyè
8 +5V REFERENCE

VALVE CONTROLLER
P/N: AX020710-PG9
Tablo Inite

Dimansyon Komisyon Konsèy
Dimansyon Komisyon Konsèy

Figure 6 – AX020710-PG9 Board Dimensions

Enstriksyon pou monte
Nòt ak Avètisman

  • Pa enstale tou pre high-voltage oswa segondè-aktyèl aparèy.
  • Note the operating temperature range. All field wiring must be suitable for that temperature range
  • Enstale inite a ak espas apwopriye ki disponib pou sèvis ak pou aksè adekwat ekipay fil (15 cm) ak soulajman souch (30 cm).
  • Do not connect or disconnect the unit while the circuit is live unless the area is known to be non-hazardous.

Montaj
Mounting holes are sized for #6 or M4 bolts. The bolt length will be determined by the end-user’s mounting plate thickness. The mounting flange of the controller is 0.062 inches (1.5 mm) thick

If the module is mounted without an enclosure, it should be mounted vertically with connectors faoing left or right to reduce likelihood of moisture entry.

Tout fil elektrik jaden yo ta dwe apwopriye pou ranje tanperati opere.

Install the unit with appropriate space available for servicing and for adequate wire hamess access.

Koneksyon

It recommended to use 14-16 AWG wire for connection to power and solenoid

Tips on Configuration with NFC

Kote ak seri antèn NFC diferan de smartphone ak smartphone. Pou akomode diferan ranje ak kote, antèn NFC kontwolè a aksesib apati bò anwo ak anba tablo a.

Tou depan de kote antèn NFC a ak/oswa seri smartphone android itilizatè a, li ka pi bon pou konfigirasyon kontwolè a soti nan yon bò oswa nan lòt la. Li rekòmande pou detèmine kote antèn NFC la sou smartphone la ak/oswa idantifye kote ak ranje ki pi byen adapte smartphone la.

The metal enclosure acts as a shield for the NFC communication thus for AX020710-1.5M or AX020710-PG9, the board needs to be removed from the housing prior to configuring it.

Paramèt Kontwolè Aksè ak E-Write NFC

Anpil paramèt yo te referans nan tout manyèl sa a. Seksyon sa a dekri epi montre chak paramèt, ansanm ak default yo ak chenn yo. Pou plis enfòmasyon sou fason 1IN-1OUT-NFC itilize chak paramèt, al gade nan seksyon ki enpòtan nan Manyèl Itilizatè a.

Enfòmasyon sou kontwolè
Enfòmasyon sou Kontwolè a bay enfòmasyon tankou vèsyon aktyèl firmwèr ak dat, nimewo seri, ansanm ak yon paramèt configurable pou pi byen idantifye divès kalite contrôleur 1IN-1OUT-NFC nan yon sistèm aplikasyon Controller Alias.
Enfòmasyon sou kontwolè
Ekran Capture nan Paramèt Enfòmasyon Kontwolè

Antre inivèsèl

Blòk fonksyon Inivèsèl la defini nan Seksyon 1.2. Tanpri gade nan seksyon sa a pou enfòmasyon detaye sou fason yo itilize paramèt sa yo.
Universal Input Parameters Universal Input Parameters
Kaptire Ekran nan Paramèt Antre Inivèsèl Default

Non Range Default Nòt
Input Type Drop List Voltage -5V to 5V Refer to Section 1.2.1
Error Detection Drop List Fo
Pulses per Revolution 0 a 60000 0 If set to 0, measurements are taken in Hz. If value is set greater than 0, mezi yo pran an RPM
Minimum Error Depends on Input Type 0.2 (V) Refer to Section 1.2.4
Minimum Range Depends on Input Type 0.5 (V) Refer to Section 1.2.3
Maximum Range Depends on Input Type 4.5 (V) Refer to Section 1.2.3
Maximum Error Depends on Input Type 4.8 (V) Refer to Section 1.2.4
Error Hysteresis Depends on 0.5 (V) Refer to Section 1.2.4
Input Type  
Digital Debounce Time 0 a 60000 10 (ms) Refer to Section 1.2.2
Pullup/Pulldown Resistor Drop List 0 - Pullup/down Off Refer to Section 1.2.2
Software Filter Type Drop List 0 - Non Filtre Refer to Section 1.2.5
Software Filter Constant 0 a 60000 1000 ms Refer to Section 1.2.5

Proportional Output Drive
The Universal Input function block is defined in Section 1.4. Please refer to that section for detailed
information on how these parameters are used.
Universal Input ParametersUniversal Input Parameters
Kaptire Ekran nan Paramèt Antre Inivèsèl Default

Non

Range

Default

Nòt

Control Source

Drop List

Universal Input

Refer to Section 1.3

Output Type

Drop List

Proportional Current

Refer to Section 1.3

Output at Minimum Command

Depends on Output Type

300 (mA)

Refer to Section 1.4

Output at Maximum

Depends on

1500 (mA)

Refer to Section 1.4

Kòmandman

Output Type

Ramp Up (Min to Max)

0-60000

1000 (ms)

Refer to Section 1.4

Ramp Down (Max to Min)

0-60000

1000 (ms)

Refer to Section 1.4

  PWM Output Frequency

  1 a 25000

  25000 (Hz)

User can change the output frequency in any Output Type selected. However, output accuracy will be affected inProportional Current Mode

Dither Frequency

50-500

250 (Hz)

Only used in Proportional Current and Hotshot Current Modes

Dither Amplitid

0 a 500

0 (mA)

Only used in Proportional Current and Hotshot Current Modes

Hotshot Time

0-60000

1000 (ms)

Hotshot Current

0-3000

1500 (mA)

Lookup Table Parameters

The Lookup Table function block is defined in Section 1.5. Please refer there for detailed
 information about how all these parameters are used.
Paramèt Paramèt
Ekran Capture nan Example Lookup Table Parameters

Non Range Default Nòt
Control Source Drop List Not Used Refer to Section 1.3
Repons Drop List Data Response Refer to Section 1.5.1
Oto-monte bisiklèt Drop List Fo Refer to Section 1.5.5
Point Response Push Option Ramp Refer to Section 1.5.4
X-Axis Point 0 0- X-AxisPoint 1 0 (%) X-Axis Points always in terms of percentage nan Kontwòl Sous selected. Refer to Section 1.5.1
X-Axis Point 1 X-Axis Point 0 to X-AxisPoint 2 20 (%) X-Axis Points always in terms of percentage nan Kontwòl Sous selected. Refer to Section 1.5.1
X-Axis Point 2 X-Axis Point 1 to X-AxisPoint 3 40 (%) X-Axis Points always in terms of percentage nan Kontwòl Sous selected. Refer to Section 1.5.1
X-Axis Point 3 X-Axis Point 2 to X-AxisPoint 4 60 (%) X-Axis Points always in terms of percentage nan Kontwòl Sous selected. Refer to Section 1.5.1
X-Axis Point 4 X-Axis Point 3 to X-AxisPoint 4 80 (%) X-Axis Points always in terms of percentage nan Kontwòl Sous selected. Refer to Section 1.5.1
X-Axis Point 5 X-Axis Point 4 to 100 100 (%) X-Axis Points always in terms of percentage nan Kontwòl Sous selected. Refer to Section 1.5.1
Y-Axis Point 0 0-3000 0 Refer to Section 1.5.2
Y-Axis Point 1 0-3000 250 Refer to Section 1.5.2
Y-Axis Point 2 0-3000 500 Refer to Section 1.5.2
Y-Axis Point 3 0-3000 750 Refer to Section 1.5.2
Y-Axis Point 4 0-3000 1000 Refer to Section 1.5.2
Y-Axis Point 5 0-3000 1250 Refer to Section 1.5.2

Espesifikasyon teknik

Espesifikasyon yo endike epi yo ka chanje. Pèfòmans aktyèl yo pral varye selon aplikasyon an ak kondisyon fonksyònman yo. Itilizatè yo ta dwe satisfè tèt yo ke pwodwi a apwopriye pou itilize nan aplikasyon an gen entansyon. Tout pwodwi nou yo pote yon garanti limite kont domaj nan materyèl ak atizan konn fè. Tanpri gade nan Garanti nou an, Apwobasyon Aplikasyon/Limitasyon ak Pwosesis Retounen Materyèl jan sa dekri nan
https://www.axiomatic.com/service/.

Pwovizyon pou pouvwa

Power Supply Input – Nominal 12 or 24Vdc nominal operating voltage9…36 Vdc power supply range for voltage transitoires OvervoltagYo bay pwoteksyon jiska 45V. Overvoltage (undervoltage) shutdown of the output load is provided.
Pwoteksyon kont surgman Bay
Reverse Polarity Protection Bay

Antre

Analog Input Functions Voltage Input or Current Input
Voltage Input -5V…+5V (Impedance 110 kOhm)-10V…+10V (Impedance 130 kOhm)
Current Input 0-20 mA (Impedance 249 Ohm)
Digital Input Functions Discrete Input, PWM Input or Frequency Input
Digital Input Level Up to VPS
PWM Input 0…100%10 Hz…1kHz 100Hz…10 kHz
Frequency Input 0.5Hz…50Hz10 Hz…1kHz 100Hz…10 kHz
Digital Input Active High (to + VPS), Active Low Amplitude: 0 to + VPSThreshold: Low < 1V; High < 2.2V
Enpedans Antre 10KOhm pull down, 10KOhm pull up to +6V
Input Accuracy <1%
Analog Input Resolution 12-bit ADC
Frequency / PWM Input Resolution 16-bit Timer

Sòti

Sòti Up to 3AHalf-bridge, High Side Sourcing, Current Sensing, Grounded Load High Frequency (25 kHz)The user can select the following options for output using E-Write NFC.· Output Disable· Output Current (PID loop, with current sensing) (0-3A)· Hotshot Digital· Proportional Output Voltage (up to VPS)· Output PWM Duty Cycle (0-100% Duty)· Digital On/Off (GND-VPS)
Output Accuracy Output Current mode <1% Output Voltage mode <5%Output PWM Duty Cycle mode <0.1%
Output Resolution Output Current mode 1 mA Output Voltage mode 0.1V Output PWM mode 0.1%
Pwoteksyon Over-Current and short circuit protection

Kominikasyon

NFC Forum Type 4 Near Field Communication Full-duplexData rate: 106 kbit/sComplies with ISO1443 (RF protocol), ISO13239, and ISO7816 Protected and secure configuration
User Interface E-WRITE NFC Application is available for a fee from Google Play for Android devices (https://play.google.com/store/apps/details?id=com.axiomatic.ewritenfc).E-WRITE NFC Application can be downloaded for a fee from Apple’s App Store for iOS devices (https://apps.apple.com/us/app/e-write-nfc/id6473560354).

Espesifikasyon jeneral

Mikwoprosesè STM32F205RET632-bit, 512 Kbit program flash
Quiescent Current Contact Axiomatic.
Dirije Endikatè Power, heartbeat and output fault indication
Response Time Contact Axiomatic.
Control Logic User programmable functionality using E-Write NFC
Kondisyon Fonksyònman -40 to 85 °C (-40 to 185 °F)
Pwoteksyon IP00 for AX020710IP67 for AX020710-1.5M and AX020710-PG9
Dimansyon PCB:63.5 mm x 63.5 mm x 20 mm (2.5 in x 2.5 in x 0.78 in) (L x W x H)Metal Box with gasket and PG9 strain relief:114 mm x 32 mm x 89 mm (4.5 in x 1.25 in x 3.5 in) (W x D x H excluding PG9 strain relief) Refer to the dimensional drawing.
Vibration MIL-STD-202G, Method 204D test condition C (Sine) and Method 214A, test condition B (Random)10 g peak (Sine)7.68 Grms peak (Random) Pending
Chòk MIL- STD-202G, Method 213B, test condition A 50g (half sine pulse, 9ms long, 8 per axis)Pending
Apwobasyon CE Marking Pending
Pwa AX020710 – 0.05 lb. (0.023 kg)AX020710-PG9 – 0.72 lb. (0.327 kg)AX020710-1.5M – 1.0 lb. (0.453 kg)
Electrical Connections Refer to Section 2 of User Manual
Montaj Mounting holes are sized for #6 or M4 bolts. The bolt length will be determined by the end-user’s mounting plate thickness. The mounting flange of the controller is 0.062 inches (1.5 mm) thick. If the module is mounted without an enclosure, it should be mounted vertically with connectors facing left or right to reduce likelihood of moisture entry. All field wiring should be suitable for the operating temperature range. Install the unit with appropriate space available for servicing and for adequate wire harness access.

ISTWA VÈSYON

Version Dat Otè Modifikasyon
1 May 8th, 2020 Gustavo Del Valle Initial Release
1.1 8 Out 2023 Kiril Mojsov Performed Legacy Updates
1.2 24 jiyè 2024 M Ejaz Added Android and iOS app links
 PWODWI NOU YO
  • AC/DC Power Supplies
  • Kontwòl/entèfas actuator
  • Entèfas Ethernet otomobil
  • Batri chajè
  • CAN Kontwòl, Routeurs, Repeater
  • CAN/WIFI, CAN/Bluetooth, Routers
  • Kouran / Voltage/PWM konvètisè
  • DC/DC Power Converters
  • Tanperati motè eskanè
  • Ethernet / CAN Convertisseurs, Gateways, Switch
  • Fan Drive Controllers
  • Passerelles, CAN/Modbus, RS-232
  • Jiroskop, Inclinometers
  • Kontwolè Valv idwolik
  • Inklinomètr, Triaxial
  • Kontwòl I/O
  • Konvètisè siyal LVDT
  • Kontwòl machin
  • Modbus, RS-422, RS-485 Kontwòl
  • Kontwòl motè, varyateur
  • Pwovizyon pou pouvwa, DC/DC, AC/DC
  • PWM siyal konvètisè/izolatè
  • Kondisyonè siyal rezolisyon
  • Zouti Sèvis
  • Kondisyonè siyal, konvètisè
  • Kontwòl kalib souch yo
  • Sipresyon vag

KONPAYI NOU

Axiomatic bay konpozan kontwòl machin elektwonik sou gran wout, machin komèsyal, machin elektrik, seri dèlko pouvwa, manyen materyèl, enèji renouvlab ak mache endistriyèl OEM. Nou inove ak enjenyè ak kontwòl machin ki pa nan etajè ki ajoute valè pou kliyan nou yo.

KALITE DESIGN AK MANIFAKTI

Nou gen yon ISO9001:2015 anrejistre konsepsyon / etablisman fabrikasyon nan Kanada.

GARANTI, Apwobasyon APLIKASYON/LIMITASYON

Axiomatic Technologies Corporation rezève dwa pou fè koreksyon, modifikasyon, amelyorasyon, amelyorasyon, ak lòt chanjman nan pwodwi ak sèvis li yo nenpòt ki lè epi sispann nenpòt pwodwi oswa sèvis san avètisman. Kliyan yo ta dwe jwenn dènye enfòmasyon enpòtan yo anvan yo mete lòd epi yo ta dwe verifye si enfòmasyon sa yo aktyèl e konplè. Itilizatè yo ta dwe satisfè tèt yo ke pwodwi a apwopriye pou itilize nan aplikasyon an gen entansyon. Tout pwodwi nou yo pote yon garanti limite kont domaj nan materyèl ak atizan konn fè. Tanpri gade nan Garanti nou an, Apwobasyon Aplikasyon/Limitasyon ak Pwosesis Retounen Materyèl nan  https://www.axiomatic.com/service/.

KONFÒMITE

Ou ka jwenn detay sou konfòmite pwodwi nan literati pwodwi a ak/oswa sou axiomatic.com. Nenpòt kesyon yo ta dwe voye bay sales@axiomatic.com.

ITILIZE SEKIRITE
Tout pwodwi yo ta dwe sèvis pa Axiomatic. Pa louvri pwodwi a epi fè sèvis la tèt ou.

Icône avètisman Pwodui sa a ka ekspoze ou nan pwodui chimik yo konnen nan Eta Kalifòni, USA pou lakòz kansè ak domaj repwodiktif. Pou plis enfòmasyon ale nan www.P65Warnings.ca.gov.

SÈVIS

Tout pwodwi yo dwe retounen nan Axiomatic mande pou yon Retounen Materyèl otorizasyon Nimewo (RMA#) soti nan rma@axiomatic.com. Tanpri bay enfòmasyon sa yo lè w ap mande yon nimewo RMA:

  • Nimewo seri, nimewo pati
  • Orè ègzekutabl, deskripsyon pwoblèm
  • Fil elektrik mete kanpe dyagram, aplikasyon ak lòt kòmantè jan sa nesesè

DISPOSITION
Pwodwi aksiomatik yo se fatra elektwonik. Tanpri swiv lwa, règleman ak règleman sou fatra anviwònman lokal ou a ak resiklaj pou jete oswa resiklaj dechè elektwonik yo san danje.

KONTAK

Axiomatic Technologies Corporation
1445 Courtneypark Drive E. Mississauga, ON
Kanada L5T 2E3
TEL: +1 905 602 9270
FAKS: +1 905 602 9279
www.axiomatic.com
sales@axiomatic.com

Axiomatic Technologies Oy
Höytämöntie 6 33880 Lempäälä
FINLAND
TEL: +358 103 375 750
www.axiomatic.com
salesfinland@axiomatic.com

AKSYOMATIC Logo

Dokiman / Resous

AXIOMATIC AX020710 Single Sorti Valv Kontwolè [pdfManyèl Itilizatè
AX020710, AX020710 Single Sorti Valv Kontwolè, Single Sorti Valv Kontwolè, Sòti Valv Kontwolè, Valv Kontwolè, Kontwolè

Referans

Kite yon kòmantè

Adrès imel ou p ap pibliye. Jaden obligatwa yo make *