TURCK logo b1

Your Global Automation Partner

LI-Q25L…E

Linear Position Sensors
with Analog Output

Instructions for Use

1 About these instructions

These instructions for use describe the structure, functions and the use of the product and will help you to operate the product as intended. Read these instructions carefully before using the product. This is to avoid possible damage to persons, property or the device. Retain the instructions for future use during the service life of the product. If the product is passed on, pass on these instructions as well.

1.1 Target groups

These instructions are aimed at qualified personal and must be carefully read by anyone mounting, commissioning, operating, maintaining, dismantling or disposing of the device.

1.2 Explanation of symbols used

The following symbols are used in these instructions:


LI-Q25L…E - CautionDANGER
DANGER indicates a dangerous situation with high risk of death or severe injury if not avoided.


LI-Q25L…E - CautionWARNING
WARNING indicates a dangerous situation with medium risk of death or severe injury if not avoided.


LI-Q25L…E - CautionCAUTION
CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided.


LI-Q25L…E - NoticeNOTICE
NOTICE indicates a situation which may lead to property damage if not avoided.


LI-Q25L…E - NoteNOTE
NOTE indicates tips, recommendations and useful information on specific actions and facts. The notes simplify your work and help you to avoid additional work.


LI-Q25L…E - CALL TO ACTIONCALL TO ACTION
This symbol denotes actions that the user must carry out.


LI-Q25L…E - RESULTS OF ACTIONRESULTS OF ACTION
This symbol denotes relevant results of actions.


1.3 Other documents

Besides this document, the following material can be found on the Internet at www.turck.com:
LI-Q25L…E - BulletData sheet

1.4 Feedback about these instructions

We make every effort to ensure that these instructions are as informative and as clear as possible. If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com.

2 Notes on the product
2.1 Product identification

LI-Q25L…E - Product identification 1

LI-Q25L…E - Product identification 2

  1. Inductive linear position sensor
  2. Housing style
  3. Electrical version
  4. Positioning element
    P0   No positioning element
    P1   P1-LI-Q25L
    P2   P2-LI-Q25L
    P3   P3-LI-Q25L
  5. Measuring range
    100   100…1000 mm, in 100 mm steps
    1250…2000 mm, in 250 mm steps
  6. Functional principle
    LI   Linear inductive
  7. Mounting element
    M0   No mounting element
    M1   M1-Q25L
    M2   M2-Q25L
    M4   M4-Q25L
  8. Housing style
    Q25L Rectangular, profile 25 × 35 mm
  9. Number of LEDs
    X3   3 × LED
  10. Output mode
    LIU5   Analog output
    4…20 mA/0…10 V
  11. Series
    E   Extended generation

LI-Q25L…E - Product identification 3

  1. Electrical connection
  2. Configuration
    1   Standard configuration
  3. Number of contacts
    5   5 pin, M12 × 1
  4. Connector
    1   Straight
  5. Connector
    H1   Male M12 × 1
2.2 Scope of delivery

The scope of delivery includes:

LI-Q25L…E - BulletLinear position sensor (without positioning element)
LI-Q25L…E - BulletOptional: Positioning element and mounting element

2.3 Turck service

Turck supports you with your projects, from initial analysis to the commissioning of your application. The Turck product database under www.turck.com contains software tools for programming, configuration or commissioning, data sheets and CAD files in numerous export formats.

The contact details of Turck subsidiaries worldwide can be found on p. [LI-Q25L…E - Bullet 2 26].

3 For your safety

The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.

3.1 Intended use

The inductive linear position sensors are used for contactless and wear-free linear position measuring.

The devices may only be used as described in these instructions. Any other use is not in accordance with the intended use. Turck accepts no liability for any resulting damage.

3.2 Obvious misuse

LI-Q25L…E - BulletThe devices are not safety components and must not be used for personal or property protection.

3.3 General safety notes

LI-Q25L…E - BulletThe device may only be assembled, installed, operated, parameterized and maintained by professionally-trained personnel.
LI-Q25L…E - BulletThe device may only be used in accordance with applicable national and international regulations, standards and laws.
LI-Q25L…E - BulletThe device meets the EMC requirements for industrial areas. When used in residential areas, take measures to avoid radio interference.

4 Product description

The inductive linear position sensors of the Li-Q25L product series consist of a sensor and a positioning element. The two components form a measuring system for measuring for converting the measured variable, length or position.

The sensors are supplied with a measuring length of 100…2000 mm: In the 100…1000-mm range, variants are available in 100-mm increments, in the 1000…2000-mm range in 250-mm increments. The maximum measuring range of the sensor is determined by its length. However, the start point of the measuring range can be individually adapted using a teach-in process.

The sensor is housed in a rectangular aluminum profile. The positioning element is available in different variants in a plastic housing (cf. accessories list in chapter 4.5). The sensor and positioning element fulfill the requirements of protection class IP67 and can withstand vibrations of moving machine parts as well as a range of other aggressive ambient conditions for long periods of time. The sensor and positioning element together enable contactless and wear-free measuring. The sensors operate in absolute mode. Power outages do not require renewed zero offset adjustment or recalibration. All position values are determined as absolute values. Homing movements after a voltage drop are unnecessary.

4.1 Device overview

LI-Q25L…E - Fig. 1

Fig. 1: Dimensions in mm – L = 29 mm + measuring length + 29 mm

LI-Q25L…E - Fig. 2

Fig. 2: Dimensions – device height

4.2 Properties and features

LI-Q25L…E - BulletMeasurement lengths from 100…2000 mm
LI-Q25L…E - BulletShock-proof up to 200 g
LI-Q25L…E - BulletMaintains linearity under shock load
LI-Q25L…E - BulletImmune to electromagnetic interference
LI-Q25L…E - Bullet5-kHz sampling rate
LI-Q25L…E - Bullet16-bit resolution

4.3 Operating principle

The Li-Q25L linear position sensors have contactless operation based on the inductive resonant circuit measuring principle. Measuring is immune to magnetic fields as the positioning element is not based on a magnet but on a coil system. Sensor and positioning element form an inductive measuring system. An induced voltage generates appropriate signals in the receiver coils of the sensor, depending on the location of the positioning element. The signals are evaluated in the internal 16-bit processor of the sensor and output as analog signals.

4.4 Functions and operating modes

The devices feature a current and voltage output. The device provides a current and voltage signal at the output proportional to the position of the positioning element.

LI-Q25L…E - Fig. 3

Fig. 3: Output characteristics

4.4.1 Output function

The measuring range of the sensor starts at 4 mA or 0 V and ends at 20 mA or 10 V. Current and voltage output can be used simultaneously. Current and voltage outputs can be used simultaneously for functions such as redundant signal evaluation. In addition, one display unit can receive a signal while the second signal is processed by a PLC.

In addition to the LEDs, the sensor offers an additional control function. If the positioning element is outside the detection range and the coupling between the sensor and the positioning element is interrupted, the analog output of the sensor outputs 24 mA or 11 V as a fault signal. This error can therefore be evaluated directly via the higher-level control.

4.5 Technical accessories

4.5.1 Mounting accessories

Dimension drawing Type ID Description
LI-Q25L…E - Dimension drawing 1
  1. reference point 
P1-LI-Q25L 6901041 Guided positioning element for LI- Q25L linear position sensors, inserted in the groove of the sensor
LI-Q25L…E - Dimension drawing 2
  1. reference point 
P2-LI-Q25L 6901042 Floating positioning element for LI-Q25L linear position sensors; the nominal distance to the sensor is 1.5 mm; pairing with the linear position sensor at a distance of up to 5 mm or a misalignment tolerance of up to 4 mm
LI-Q25L…E - Dimension drawing 3
  1. reference point 
P3-LI-Q25L 6901044 Floating positioning element for LI-Q25L linear position sensors; operational at an offset of 90°; the nominal distance to the sensor is 1.5 mm; pairing with the linear position sensor at a distance of up to 5 mm or a misalignment tolerance of up to 4 mm
LI-Q25L…E - Dimension drawing 4
  1. reference point 
P6-LI-Q25L 6901069 Floating positioning element for LI-Q25L linear position sensors; the nominal distance to the sensor is 1.5 mm; pairing with the linear position sensor at a distance of up to 5 mm or a misalignment tolerance of up to 4 mm
LI-Q25L…E - Dimension drawing 5
  1. reference point 
P7-LI-Q25L 6901087 Guided positioning element for LI- Q25L linear position sensors, without ball joint
LI-Q25L…E - Dimension drawing 6 M1-Q25L 6901045 Mounting foot for LI-Q25L linear position sensors; material: aluminum; 2 pcs. per bag
LI-Q25L…E - Dimension drawing 7 M2-Q25L 6901046 Mounting foot for LI-Q25L linear position sensors; material: aluminum; 2 pcs. per bag
LI-Q25L…E - Dimension drawing 8 M4-Q25L 6901048 Mounting bracket and sliding block for LI-Q25L linear position sensors; material: stainless steel; 2 pcs. per bag
LI-Q25L…E - Dimension drawing 9 MN-M4-Q25 6901025 Sliding block with M4 thread for the backside profile of the LI-Q25L linear position sensor; material: galvanized metal; 10 pcs. per bag
LI-Q25L…E - Dimension drawing 10 AB-M5 6901057 Axial joint for guided positioning element
LI-Q25L…E - Dimension drawing 11 ABVA-M5 6901058 Axial joint for guided positioning elements; material: stainless steel
LI-Q25L…E - Dimension drawing 12 RBVA-M5 6901059 Angle joint for guided positioning element; material: stainless steel

4.5.2 Connection accessories

Dimension drawing Type ID Description
LI-Q25L…E - Dimension drawing 13  TX1-Q20L60 6967114  Teach adapter
LI-Q25L…E - Dimension drawing 14 RKS4.5T-2/TXL 6626373 Connection cable, M12 female connector, straight, 5-pin, shielded: 2 m, jacket material: PUR, black; cULus approval; other cable lengths and versions available, see www.turck.com
5 Installing

LI-Q25L…E - NoteNOTE
Install positioning elements centrally above the sensor. Observe LED behavior (see chapter “Operation”).


LI-Q25L…E - CALL TO ACTIONInstall the linear position sensor in the system using the required mounting accessories.

LI-Q25L…E - Installing 1

LI-Q25L…E - Installing 2

Fig. 4: Example — installation with mounting foot or mounting bracket

Mounting element Recommended tightening torque
M1-Q25L 3 Nm
M2-Q25L 3 Nm
MN-M4-Q25L 2.2 Nm
Sensor type Recommended number of fixings
LI100…LI500 2
LI600…LI1000 4
LI1250…LI1500 6
LI1750…LI2000 8
5.1 Mounting free positioning elements

LI-Q25L…E - CALL TO ACTIONCenter the free positioning element above the sensor.
LI-Q25L…E - CALL TO ACTIONIf LED 1 lights up yellow, the positioning element is in the measuring range. Signal quality is degraded. Correct the alignment of the positioning element until LED 1 lights up green.
LI-Q25L…E - CALL TO ACTIONIf LED 1 flashes yellow, the positioning element is not in the measuring range. Correct the alignment of the positioning element until LED 1 lights up green.
LI-Q25L…E - RESULTS OF ACTIONLED 1 lights up green when the positioning element is in the measuring range.

LI-Q25L…E - Fig. 5

Fig. 5: Center the free positioning element

6 Connection

LI-Q25L…E - NoticeNOTICE
Incorrect female connector
Damage to the M12 male connector possible
LI-Q25L…E - CALL TO ACTIONEnsure correct connection.



LI-Q25L…E - NoteNOTE
Turck recommends the use of shielded connection cables.


LI-Q25L…E - CALL TO ACTIONDuring the electrical installation of the sensor, keep the entire system de-energized.
LI-Q25L…E - CALL TO ACTIONConnect the female connector of the connection cable to the male connector of the sensor.
LI-Q25L…E - CALL TO ACTIONConnect the open end of the connection cable to the power supply and/or processing units.

6.1 Wiring diagram

LI-Q25L…E - NoteNOTE
To prevent unintentional teaching, keep pin 5 potential-free or activate the teach lock.


LI-Q25L…E - Fig. 6

Fig. 6: M12 male connector — pin assignment

LI-Q25L…E - Fig. 7

Fig. 7: M12 male connector — wiring diagram

7 Commissioning

After connecting and switching on the power supply, the device is automatically ready for operation.

8 Operation
8.1 LED indications

LI-Q25L…E - Fig. 8

Fig. 8: LEDs 1 and 2

LED Display Meaning
LED 1 Green Positioning element within the measuring range
Yellow Positioning element within the measuring range with a reduced signal quality (e.g. distance to sensor too large)
Yellow flashing Positioning element not in detection range
Off Positioning element outside the set measuring range
LED 2 Green Power supply error-free
9 Setting

The sensor offers the following setting options:

LI-Q25L…E - BulletSet the start of the measuring range (zero point)
LI-Q25L…E - BulletSet the end of the measuring range (end point)
LI-Q25L…E - BulletReset measuring range to factory setting: largest possible measuring range
LI-Q25L…E - BulletReset measuring range to inverted factory setting: largest possible measuring range, output curve inverted
LI-Q25L…E - BulletActivate/deactivate teach lock

The measuring range can be set by manual bridging or with the TX1-Q20L60 teach adapter. The zero point and end point of the measuring range can be set in succession or separately.


LI-Q25L…E - NoteNOTE
To prevent unintentional teaching, keep pin 5 potential-free or activate the teach lock.


9.1 Setting via manual bridging

9.1.1 Setting the measuring range

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONPlace the positioning element at the desired zero point of the measuring range.
LI-Q25L…E - CALL TO ACTIONBridge pin 5 and pin 3 for 2 s.
LI-Q25L…E - RESULTS OF ACTIONLED 2 flashes green for 2 s during bridging.
LI-Q25L…E - RESULTS OF ACTIONThe zero point of the measuring range is stored.

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONPlace the positioning element at the desired end point of the measuring range.
LI-Q25L…E - CALL TO ACTIONBridge pin 5 and pin 1 for 2 s.
LI-Q25L…E - RESULTS OF ACTIONLED 2 flashes green for 2 s during bridging.
LI-Q25L…E - RESULTS OF ACTIONThe end point of the measuring range is stored

9.1.2 Reset the sensor to the factory settings

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONBridge pin 5 and pin 1 for 10 s.
LI-Q25L…E - RESULTS OF ACTIONLED 2 initially flashes green for 2 s, then lights up green continuously for 8 s and flashes green again (after a total of 10 s).
LI-Q25L…E - RESULTS OF ACTIONThe sensor is reset to its factory setting.

9.1.3 Reset the sensor to the inverted factory settings

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONBridge pin 5 and pin 3 for 10 s.
LI-Q25L…E - RESULTS OF ACTIONLED 2 initially flashes green for 2 s, then lights up green continuously for 8 s and flashes green again (after a total of 10 s).
LI-Q25L…E - RESULTS OF ACTIONThe sensor is reset to its inverted factory setting.

TURCK logo b1Setting
Setting via teach adapter

9.1.4 Activating the teach lock


LI-Q25L…E - NoteNOTE
The teach lock function is deactivated on delivery.


LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONBridge pin 5 and pin 1 for 30 s.
LI-Q25L…E - RESULTS OF ACTIONLED 2 initially flashes green for 2 s, then lights up green continuously for 8 s, flashes green again (after a total of 10 s) and flashes green (after a total of 30 s) at a higher frequency.
LI-Q25L…E - RESULTS OF ACTIONThe teach lock function of the sensor is activated.

9.1.5 Deactivating teach lock

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONBridge pin 5 and pin 1 for 30 s.
LI-Q25L…E - RESULTS OF ACTIONLED 2 lights up green continuously for 30 s (teach lock is still activated) and after 30 s flashes green at a higher frequency.
LI-Q25L…E - RESULTS OF ACTIONThe teach lock function of the sensor is deactivated.

9.2 Setting via teach adapter

9.2.1 Setting the measuring range

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONPlace the positioning element at the zero point of the measuring range.
LI-Q25L…E - CALL TO ACTIONTeach-in the pushbutton on the adapter for 2 s against GND.
LI-Q25L…E - RESULTS OF ACTIONLED 2 flashes green for 2 s and then lights up green continuously.
LI-Q25L…E - RESULTS OF ACTIONThe zero point of the measuring range is stored.

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONPlace the positioning element at the end point of the measuring range.
LI-Q25L…E - CALL TO ACTIONTeach-in the pushbutton on the adapter for 2 s against UB.
LI-Q25L…E - RESULTS OF ACTIONLED 2 flashes green for 2 s and then lights up green continuously.
LI-Q25L…E - RESULTS OF ACTIONThe zero point of the measuring range is stored.

9.2.2 Reset the sensor to the factory settings

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONTeach-in the pushbutton on the adapter for 10 s against UB.
LI-Q25L…E - RESULTS OF ACTIONLED 2 initially flashes green for 2 s, then lights up green continuously for 8 s and flashes green again (after a total of 10 s).
LI-Q25L…E - RESULTS OF ACTIONThe sensor is reset to the factory setting.

9.2.3 Reset the sensor to the inverted factory settings

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONTeach-in the pushbutton on the adapter for 10 s against GND.
LI-Q25L…E - RESULTS OF ACTIONLED 2 initially flashes green for 2 s, then lights up green continuously for 8 s and flashes green again (after a total of 10 s).
LI-Q25L…E - RESULTS OF ACTIONThe sensor is reset to the inverted factory setting.

9.2.4 Activating the teach lock


LI-Q25L…E - NoteNOTE
The teach lock function is deactivated on delivery.


LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONTeach-in the pushbutton on the adapter for 30 s against UB.
LI-Q25L…E - RESULTS OF ACTIONLED 2 initially flashes green for 2 s, then lights up green continuously for 8 s, flashes green again (after a total of 10 s) and flashes green (after a total of 30 s) at a higher frequency.
LI-Q25L…E - RESULTS OF ACTIONThe teach lock function of the sensor is activated.

9.2.5 Deactivating teach lock

LI-Q25L…E - CALL TO ACTIONSupply the device with voltage.
LI-Q25L…E - CALL TO ACTIONTeach-in the pushbutton on the adapter for 30 s against UB.
LI-Q25L…E - RESULTS OF ACTIONLED 2 lights up green continuously for 30 s (teach lock is still activated) and after 30 s flashes green at a higher frequency.
LI-Q25L…E - RESULTS OF ACTIONThe teach lock function of the sensor is deactivated.

10 Troubleshooting

The strength of the resonance coupling is indicated by an LED. Any faults are indicated via the LEDs.

If the device does not function as expected, first check whether ambient interference is present. If there is no ambient interference present, check the connections of the device for faults.

If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type.

11 Maintenance

Ensure that the plug connections and cables are always in good condition.

The devices are maintenance-free, clean dry if required.

12 Repair

The device must not be repaired by the user. The device must be decommissioned if it is faulty. Observe our return acceptance conditions when returning the device to Turck.

12.1 Returning devices

Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed. The decontamination declaration can be downloaded from https://www.turck.de/en/retoure-service-6079.php and must be completely filled in, and affixed securely and weather-proof to the outside of the packaging.

13 Disposal

LI-Q25L…E - DisposalThe devices must be disposed of correctly and must not be included in general household garbage.

14 Technical data
Technical data
Measuring range specifications
Measuring range 100…1000 mm in 100-mm increments;
1250…2000 mm in 250-mm increments
Resolution 16 bit
Nominal distance 1.5 mm
Blind zone a 29 mm
Blind zone b 29 mm
Repetition accuracy ≤ 0.02 % of full scale
Linearity tolerance Depending on the measuring length (see data sheet)
Temperature drift ≤ ± 0.003 %/K
Hysteresis Omitted as a matter of principle
Ambient temperature -25…+70 °C
Operating voltage 15… 30 VDC
Ripple ≤10 % Uss
Insulation test voltage ≤ 0.5 kV
Short-circuit protection Yes
Wire breakage/reverse polarity protection Yes/yes (power supply)
Output function 5-pin, analog output
Voltage output 0…10 V
Current output 4…20 mA
Load resistance, voltage output ≥ 4.7 kΩ
Load resistance, current output ≤ 0.4 kΩ
Sampling rate 5 kHz
Current consumption < 50 mA
Design Rectangular, Q25L
Dimensions (Measurement length + 58) × 35 × 25 mm
Housing material Anodized aluminum
Material of active face Plastic, PA6-GF30
Electrical connection Male connector, M12 × 1
Vibration resistance (EN 60068-2-6) 20 g; 1.25 h/axis; 3 axes
Shock resistance (EN 60068-2-27) 200 g; 4 ms ½ sine
Type of protection IP67/IP66
MTTF 138 years acc. to SN 29500 (Ed. 99) 40 °C
Packed quantity 1
Operating voltage indication LED: green
Measuring range display Multifunction LED: green, yellow, yellow flashing
15 Turck subsidiaries — contact information

Germany    Hans Turck GmbH & Co. KG
Witzlebenstraße 7, 45472 Mülheim an der Ruhr
www.turck.de

Australia    Turck Australia Pty Ltd
Building 4, 19-25 Duerdin Street, Notting Hill, 3168 Victoria
www.turck.com.au

Belgium    TURCK MULTIPROX
Lion d’Orweg 12, B-9300 Aalst
www.multiprox.be

Brazil    Turck do Brasil Automação Ltda.
Rua Anjo Custódio Nr. 42, Jardim Anália Franco, CEP 03358-040 São Paulo
www.turck.com.br

China    Turck (Tianjin) Sensor Co. Ltd.
18,4th Xinghuazhi Road, Xiqing Economic Development Area, 300381
Tianjin
www.turck.com.cn

France    TURCK BANNER S.A.S.
11 rue de Courtalin Bat C, Magny Le Hongre, F-77703 MARNE LA VALLEE
Cedex 4
www.turckbanner.fr

Great Britain    TURCK BANNER LIMITED
Blenheim House, Hurricane Way, GB-SS11 8YT Wickford, Essex
www.turckbanner.co.uk

India    TURCK India Automation Pvt. Ltd.
401-403 Aurum Avenue, Survey. No 109 /4, Near Cummins Complex,
Baner-Balewadi Link Rd., 411045 Pune – Maharashtra
www.turck.co.in

Italy    TURCK BANNER S.R.L.
Via San Domenico 5, IT-20008 Bareggio (MI)
www.turckbanner.it

Japan    TURCK Japan Corporation
Syuuhou Bldg. 6F, 2-13-12, Kanda-Sudacho, Chiyoda-ku, 101-0041 Tokyo
www.turck.jp

Canada    Turck Canada Inc.
140 Duffield Drive, CDN-Markham, Ontario L6G 1B5
www.turck.ca

Korea    Turck Korea Co, Ltd.
B-509 Gwangmyeong Technopark, 60 Haan-ro, Gwangmyeong-si,
14322 Gyeonggi-Do
www.turck.kr

Malaysia    Turck Banner Malaysia Sdn Bhd
Unit A-23A-08, Tower A, Pinnacle Petaling Jaya, Jalan Utara C,
46200 Petaling Jaya Selangor
www.turckbanner.my

Mexico    Turck Comercial, S. de RL de CV
Blvd. Campestre No. 100, Parque Industrial SERVER, C.P. 25350 Arteaga,
Coahuila
www.turck.com.mx

Netherlands    Turck B. V.
Ruiterlaan 7, NL-8019 BN Zwolle
www.turck.nl

Austria    Turck GmbH
Graumanngasse 7/A5-1, A-1150 Wien
www.turck.at

Poland    TURCK sp.z.o.o.
Wroclawska 115, PL-45-836 Opole
www.turck.pl

Romania    Turck Automation Romania SRL
Str. Siriului nr. 6-8, Sector 1, RO-014354 Bucuresti
www.turck.ro

Russian Federation    TURCK RUS OOO
2-nd Pryadilnaya Street, 1, 105037 Moscow
www.turck.ru

Sweden    Turck Sweden Office
Fabriksstråket 9, 433 76 Jonsered
www.turck.se

Singapore    TURCK BANNER Singapore Pte. Ltd.
25 International Business Park, #04-75/77 (West Wing) German Centre,
609916 Singapore
www.turckbanner.sg

South Africa    Turck Banner (Pty) Ltd
Boeing Road East, Bedfordview, ZA-2007 Johannesburg
www.turckbanner.co.za

Czech Republic    TURCK s.r.o.
Na Brne 2065, CZ-500 06 Hradec Králové
www.turck.cz

Turkey    Turck Otomasyon Ticaret Limited Sirketi
Inönü mah. Kayisdagi c., Yesil Konak Evleri No: 178, A Blok D:4,
34755 Kadiköy/ Istanbul
www.turck.com.tr

Hungary    TURCK Hungary kft.
Árpád fejedelem útja 26-28., Óbuda Gate, 2. em., H-1023 Budapest
www.turck.hu

USA    Turck Inc.
3000 Campus Drive, USA-MN 55441 Minneapolis
www.turck.us

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com

V03.00 | 2022/08

TURCK logo b1

 

Over 30 subsidiaries and
60 representations worldwide!

LI-Q25L…E - worldwide map

100003779 | 2022/08
LI-Q25L…E - Bar Code

www.turck.com

Documents / Resources

TURCK LI-Q25L…E Linear Position Sensors with Analog Output [pdf] Instruction Manual
LI-Q25L E Linear Position Sensors with Analog Output, LI-Q25L E, Linear Position Sensors with Analog Output, Linear Position Sensors, Analog Output Sensors, Sensors