EPH ຄວບຄຸມ TR1V2-TR2V2 RF Mains Switch

ຂໍ້ມູນຈໍາເພາະ
- ການສະຫນອງພະລັງງານ: 200 – 240VAC 50–60Hz
- ການຈັດອັນດັບການຕິດຕໍ່: 230 ວາ 10(3) ກ
- ອຸນຫະພູມສະພາບແວດລ້ອມ: 0…45˚C
- ການປະຕິບັດອັດຕະໂນມັດ: ປະເພດ 1. ຄ.
- ຫ້ອງຮຽນເຄື່ອງໃຊ້: ເຄື່ອງໃຊ້ຊັ້ນ II

- ລະດັບມົນລະພິດ: ລະດັບມົນລະພິດ 2
- ການຈັດອັນດັບ IP: IP20
- ຈັດອັນດັບ Volulse Voltage: ຄວາມຕ້ານທານກັບ voltage surge 2500V ຕາມ EN 60730
TR1 TR2V2 ຂອງທ່ານເຮັດວຽກແນວໃດ
- Your TR1 TR2V2 is used to send a wireless signal from one location to another when running Cables is difficult, expensive, or otherwise not an option.
- The product comprises two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
- When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes, which sends voltage from Live out on the TR2V2.
- ມັນເປັນໄປໄດ້ທີ່ຈະສົ່ງສັນຍານໄຮ້ສາຍໃນທິດທາງດຽວຫຼືທັງສອງ.
- When a signal is sent from the TR1V2 to the TR2V2, a green light will activate on the TR2V2.
- When the TR2V2 sends a signal to the TR1V2, a green light will activate on the TR1V2.
- Common uses include sending a signal from a programmer to a boiler or hot water cylinder that is in a different location. These are also used to control pump overrun and many other applications.
- It is possible to have more than one set of TR1, TR2V, 2and, where required.
- ກະລຸນາເບິ່ງໜ້າ 9-13 ສຳລັບສາຍໄຟ examples
ແຜນວາດສາຍໄຟພາຍໃນສຳລັບ TR1TR2V2
ຂໍ້ຄວນລະວັງ: Installation should only be carried out by a qualified person and by wiring regulations.
Switching Options
Mains Switching
- ເຊື່ອມຕໍ່ L ກັບ 3
ຕ່ ຳtage ສະຫຼັບ
- ເອົາການເຊື່ອມຕໍ່ການຄວບຄຸມພາຍນອກອອກຈາກ boiler PCB.
- ເຊື່ອມຕໍ່ 2 ແລະ 3 ກັບ terminals ເຫຼົ່ານີ້.
ການຕິດຕັ້ງ & ການຕິດຕັ້ງ
- The TRIV2 should be wall-mounted in an area within 30 metres of the TR2V2. Both TRIV2 & TR2V2 must be mounted more than 25cm away from metal objects, as this will affect communication. The TRIV2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave, ve, or wireless network adapter. They can be fitted to
- Single-gang recessed back box.
- ກ່ອງຕິດຕັ້ງພື້ນຜິວ
- Directly mounted on a wall.
- Use a Phillips screwdriver to loosen the screws of the backplate on the bottom of the TRIV2 & TR2V2, lift upwards from the bottom, and remove the backplate.
- Screw ແຜ່ນຮອງກັບຝາດ້ວຍ screws ສະຫນອງໃຫ້.
- ສຽບແຜ່ນຮອງຕາມແຜນວາດສາຍໄຟ.
- Mount the TRIV2 & TR2V2 on the backplate, making sure the pins and the backplatcontactsts are making a sound connection. Push the TRIV2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom.m



ປຸ່ມ / ລາຍລະອຽດ LED

ຄູ່ມື ກົດເພື່ອເປີດໃຊ້ ຫຼືປິດການໃຊ້ງານຢູ່ປາຍຍອດອອກສົດ.
ເຊື່ອມຕໍ່ ຄ້າງໄວ້ 3 ວິນາທີເພື່ອເລີ່ມຕົ້ນຂະບວນການຈັບຄູ່. ແສງ RF ຈະກະພິບ.
ຣີເຊັດ Press to reset the T, R1, TR2V2.
ໝາຍເຫດ: The connection procedure is not required as both TR1 & TR2V2 are pre-paired
ລາຍລະອຽດ LED
| LED | ສີ | ລາຍລະອຽດ |
| ດໍາລົງຊີວິດຢູ່ໃນ LED | ສີແດງ | ບໍ່ມີ voltage on the Live terminal. |
| ສີຂຽວ | ມີ voltage ໃນ Live in terminal – ຕອນນີ້ສັນຍານ RF ຈະຖືກສົ່ງໄປຫາ RF Mains Switch ອື່ນເພື່ອເປີດໃຊ້ Live out terminal. | |
| ໄຟ LED | ສີຂາວ | ໄຟ LED ສີຂາວແຂງຊີ້ບອກວ່າເຄື່ອງຄວບຄຸມອຸນຫະພູມເຊື່ອມຕໍ່. |
| ໄຟ RF ຈະກະພິບສອງເທົ່າເມື່ອເຄື່ອງຄວບຄຸມອຸນຫະພູມຖືກຕັດການເຊື່ອມຕໍ່. ກວດເບິ່ງການຈັບຄູ່ເຄື່ອງຄວບຄຸມອຸນຫະພູມ. | ||
| ໝາຍເຫດ: ແສງ RF ຈະກະພິບເປັນໄລຍະໆເມື່ອລະບົບກຳລັງສົ່ງ ແລະຮັບສັນຍານສື່ສານ. | ||
| ໝາຍເຫດ: ໄຟ RF ຈະກະພິບທຸກໆວິນາທີເມື່ອຢູ່ໃນການຈັບຄູ່ RF ໂດຍຖື Connect. ກົດຄູ່ມືເພື່ອອອກຈາກສະຖານະນີ້. | ||
| LED ອອກສົດ | ສີແດງ | ບໍ່ມີສັນຍານການເປີດໃຊ້ RF ທີ່ໄດ້ຮັບຈາກ RF Mains Switch ອື່ນໆ. |
| ສີຂຽວ | ສັນຍານການເປີດໃຊ້ RF ໄດ້ຮັບຈາກສະວິດ RF Mains ອື່ນໆ. |
To connect the TRI TR2V2
ກະລຸນາສັງເກດ: When installing TRI TR2V2 RF mains switches, both TRI &TR2V2 are pre-paired. The procedures below are not required.
On TR1V2:
- ຖື
ເປັນເວລາ 3 ວິນາທີຈົນກວ່າໄຟ LED RF ຈະກະພິບເປັນສີຂາວ.
On TR2V2:
- ຖື
ເປັນເວລາ 3 ວິນາທີ. - ໄຟ LED RF ຈະເລີ່ມກະພິບ, ແລະ LED ອອກສົດຈະປາກົດເປັນສີຂຽວແຂງ.
- ເມື່ອເຊື່ອມຕໍ່, ທັງສາມ LEDs ຈະປາກົດແຂງ.
On TR1V2:
- ກົດ
ເພື່ອອອກຈາກໂໝດການຈັບຄູ່. - After connecting successfully, the RF LED on both TR1V2 & TR2V2will appear solid.
To disconnect the TRI TR2V2
- ຖື
ເປັນເວລາ 3 ວິນາທີຈົນກວ່າໄຟ LED RF ຈະກະພິບເປັນສີຂາວ. - ຖື
ເປັນເວລາ 10 ວິນາທີຈົນກ່ວາ Live in LED ຈະປາກົດເປັນສີແດງແຂງ.
On TR2V2:
- ຖື
ເປັນເວລາ 3 ວິນາທີຈົນກວ່າໄຟ LED RF ຈະກະພິບເປັນສີຂາວ. - ຖື
Connect for 10 seconds until the Live in & Live out LED appears solid red.
On TRIV2:
- ກົດ
ອອກໄປ. - The TRI TR2V2 is now disconnected.
ສາຍໄຟ Examples
Example One way RF Switch: Programmer to Boiler – Mains Switching
TR1V2
On TR1, when Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the boiler.
ບັນທຶກການຕິດຕັ້ງ
- Mains Switching Boiler
- ສຽງຕ່ ຳtage Switching Boiler
- ໃນ TR2V2
- ໃນ boiler PCB
- ໃນ TR2V2
- ເຊື່ອມຕໍ່ L ກັບ 3.
- ເອົາລິ້ງຄວບຄຸມພາຍນອກອອກ.
- ເຊື່ອມຕໍ່ terminals 2 & 3 ກັບ terminals ການຄວບຄຸມພາຍນອກໃນ boiler PCB ໄດ້.
Example 2 Two Two-way RF Switch:
- Programmer to Motorised Valve
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact ປິດ, ສົ່ງ 230V ເພື່ອເປີດໃຊ້ boiler ໄດ້.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

ບັນທຶກການຕິດຕັ້ງ
1. Main Switching Boiler
2. Low-Voltage Switching Boiler
3. ວາວມໍເຕີ
- On the TRIV2
- ໃນ boiler PCB
- On the TRIV2
- ໃນ TR2V2
- ເຊື່ອມຕໍ່ L ກັບ 3.
- ເອົາລິ້ງຄວບຄຸມພາຍນອກອອກ.
- ເຊື່ອມຕໍ່ terminals 2 & 3 ກັບ terminals ການຄວບຄຸມພາຍນອກໃນ boiler PCB ໄດ້.
- Link L to 3 to power the Live out terminal to the motorised valve.
Example 3 One way RF Switch:
Pump Overrun – Mains Switching
TR 1 v2
- On TRI, when Live in receives 230V from the boiler, TRI sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the pump.

ຫມາຍເຫດຕິດຕັ້ງ
- Pump On
- the TR2V2
- Link L to 3 to power the Live out terminal to the pump
Example 4 Two Two-way RF Switch: Pump Overrun
- Programmer ກັບ Boiler
- Boiler to Pump – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact ປິດ, ສົ່ງ 230V ເພື່ອກະຕຸ້ນປັ໊ມ.
TR2V2
- On TR2, the COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
ຫມາຍເຫດຕິດຕັ້ງ
- Mains Switching Boiler
- ສຽງຕ່ ຳtage Switching Boiler
- ສູບ
- ໃນ TR2V2
- On the boiler PCB –
- ໃນ TR2V2
- On the TRIV2
- ເຊື່ອມຕໍ່ L ກັບ 3.
- ເອົາລິ້ງຄວບຄຸມພາຍນອກອອກ.
- ເຊື່ອມຕໍ່ terminals 2 & 3 ກັບ terminals ການຄວບຄຸມພາຍນອກໃນ boiler PCB ໄດ້.
- Link L to 3 to power the Live out terminal to the pump.
Example 5 Two Two-way RF Switch: Unvented Cylinder:
- ໂປລແກລມກັບເຄື່ອງຄວບຄຸມອຸນຫະພູມສູງສຸດ
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out the contact closes, sending 230V to activate the boiler.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
ບັນທຶກການຕິດຕັ້ງ
- Mains Switching Boiler
- ສຽງຕ່ ຳtage Switching Boiler
- ເຄື່ອງຄວບຄຸມອຸນຫະພູມສູງສຸດ
- ວາວມໍເຕີ
- On the TRIV2
- ໃນ boiler PCB
- ໃນ TR2V2
- ເຊື່ອມຕໍ່ L ກັບ 3.
- ເອົາລິ້ງຄວບຄຸມພາຍນອກອອກ.
- ເຊື່ອມຕໍ່ terminals 2 & 3 ກັບ terminals ການຄວບຄຸມພາຍນອກໃນ boiler PCB ໄດ້.
- ເຊື່ອມຕໍ່ L ຫາ 3 ເພື່ອສົ່ງກະແສໄຟຟ້າຈາກສະຖານີ Live out ໄປຫາເຄື່ອງຄວບຄຸມອຸນຫະພູມທີ່ຈຳກັດສູງ.
EPH ຄວບຄຸມ IE
technical@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
cork, Tl 2 W665
EPH ຄວບຄຸມ UK
technical@ephcontrols.co.uk
www.ephcontrols.co.uk/
ຕິດຕໍ່ພວກເຮົາ
+44 1933 322 072
Harrow, HAI IBD
FAQs
Q: Can I install the TR1, TR2V2V2 devices myself?
A: Installation should only be carried out by a qualified person following wiring regulations to ensure safety and proper functionality.
Q: ໄລຍະຫ່າງສູງສຸດລະຫວ່າງ TR1V2 ແລະ TR2V2 ສໍາລັບການສື່ສານທີ່ມີປະສິດທິພາບແມ່ນຫຍັງ?
A: The recommended distance is within 30 meters for optimal wireless signal transmission.
ເອກະສານ / ຊັບພະຍາກອນ
![]() |
EPH ຄວບຄຸມ TR1V2-TR2V2 RF Mains Switch [pdf] ຄູ່ມືການສອນ TR1V2, TR2V2, TR1V2-TR2V2 RF Mains Switch, TR1V2-TR2V2, RF Mains Switch, Mains Switch, Switch |