TR1V2-TR2V2 RF મેઇન્સ સ્વિચ

વિશિષ્ટતાઓ

  • Power supply: 200 – 240Vac 50-60Hz
  • Contact rating: 230 Vac 10(3)A
  • Automatic action: Type 1.C.
  • Appliance classes: Class II appliance
  • પ્રદૂષણ ડિગ્રી: પ્રદૂષણ ડિગ્રી 2
  • IP રેટિંગ: IP20
  • રેટેડ ઇમ્પલ્સ વોલ્યુમtage: પ્રતિકાર માટે વોલ્યુમtage surge 2500V as per
    EN 60730

ઉત્પાદન વપરાશ સૂચનાઓ

માઉન્ટિંગ અને ઇન્સ્ટોલેશન

  1. The TR1V2 should be wall mounted in an area within 30 meters of
    the TR2V2. Ensure both devices are mounted more than 25cm away from
    metal objects for optimal communication.
  2. Install the TR1V2 & TR2V2 at least 1 meter away from
    electronic devices like radios, TVs, microwaves, or wireless
    network adapters. Mount them on a single gang recessed back box,
    surface mounting boxes, or directly on a wall.
  3. Using a Phillips screwdriver, loosen the screws on the
    backplate of the TR1V2 & TR2V2, lift upwards from the bottom,
    and remove from the backplate.
  4. Screw the backplate to the wall with the provided screws.
  5. Wire the backplate following the wiring diagram on page 2 of
    માર્ગદર્શિકા.

Button & LED Description

The TR1 TR2V2 features buttons and LEDs for user interaction and
status indication. Refer to the manual for detailed descriptions of
each button and LED function.

To Connect the TR1 TR2V2

Follow the steps outlined in the manual to properly connect the
TR1 TR2V2 devices for wireless signal transmission. Ensure correct
wiring connections for seamless operation.

To Disconnect the TR1 TR2V2

If needed, follow the manual instructions to safely disconnect
the TR1 TR2V2 devices. Proper disconnection is essential for
maintenance or relocation purposes.

વાયરિંગ સampલેસ

વાયરિંગ એક્સ નો સંદર્ભ લોamples provided in pages 9-13 of the
manual for different scenarios like one-way RF switch, two-way RF
switch, pump overrun control, and more. Use these examples as a
guide for wiring your TR1 TR2V2 setup.

FAQ

Q: Can I install the TR1 TR2V2 devices myself?

A: Installation should only be carried out by a qualified person
following wiring regulations to ensure safety and proper
કાર્યક્ષમતા

Q: What is the maximum distance between TR1V2 and TR2V2 for
effective communication?

A: The recommended distance is within 30 meters for optimal
wireless signal transmission.

"`

TR1 TR2V2
RF Mains Switch Installation and Operation Guide

સામગ્રીઓનું કોષ્ટક

How your TR1 TR2V2 works

1

વિશિષ્ટતાઓ અને વાયરિંગ

2

માઉન્ટિંગ અને ઇન્સ્ટોલેશન

3

Button & LED Description

5

એલઇડી વર્ણન

6

To connect the TR1 TR2V2

7

To disconnect the TR1 TR2V2

8

વાયરિંગ સampલેસ

9

Example 1 One Way RF Switch: Programmer to Boiler 230V

9

Example 2 Two Way RF Switch: Programmer to Motorised Valve Motorised Valve to Boiler 230V

10

Example 3 One Way RF Switch: Pump Overrun

11

Example 4 Two Way RF Switch: Pump Overrun

Programmer to Boiler

12

Boiler to Pump 230V

Example 5 Two Way RF Switch: Unvented Cylinder:

Programmer to High Limit Thermostat

13

Motorised Valve to Boiler 230V

How your TR1 TR2V2 works
Your TR1 TR2V2 is used to send a wireless signal from one location to another when running cables is difficult, expensive or otherwise not an option.
The product comprises of two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes which sends voltage from Live out on the TR2V2. It is possible to send a wireless signal in one direction or both.
When a signal is sent from the TR1V2 to the TR2V2 a green light will activate on the TR2V2.
When the TR2V2 sends a signal to the TR1V2 a green light will activate on the TR1V2. Common uses include sending a signal from a programmer to a boiler or hot water cylinder which are in a different locations. These are also used to control pump overrun and many other applications.
It is possible to have more than one set of TR1 TR2V2 where required. Please see page 9-13 for wiring exampલેસ

TR1 TR2V2 RF Mains Switch

1

વિશિષ્ટતાઓ અને વાયરિંગ

પાવર સપ્લાય:

200 - 240Vac 50-60Hz

સંપર્ક રેટિંગ:

230 Vac 10(3)A

આસપાસનું તાપમાન: 0…45°C

આપોઆપ ક્રિયા:

Type 1.C.

ઉપકરણ વર્ગો:

વર્ગ II ઉપકરણ

પ્રદૂષણ ડિગ્રી:

પ્રદૂષણ ડિગ્રી 2

IP રેટિંગ:

IP20

રેટેડ ઇમ્પલ્સ વોલ્યુમtage: પ્રતિકાર માટે વોલ્યુમtagEN 2500 મુજબ e surge 60730V

Internal wiring diagram for TR1TR2V2

Live Live in out COM N/C

200-240V~ 50/60Hz

NL 1 2 3 4

સાવધાન!
Installation should only be carried out by a qualified person and in accordance with wiring regulations.

સ્વિચિંગ વિકલ્પો

Mains Switching Link L to 3

લો વોલ્યુમtage સ્વિચિંગ
Remove the external controls link from the boiler PCB. Connect 2 and 3 to these terminals.

2

TR1 TR2V2 RF Mains Switch

માઉન્ટિંગ અને ઇન્સ્ટોલેશન
1) The TR1V2 should be wall mounted in an area within 30 metres of the TR2V2. It is important that both TR1V2 & TR2V2 are mounted more than 25cm away from metal objects as this will affect communication.
The TR1V2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave or wireless network adapter. They can be fitted to: 1. Single gang recessed back box
2. Surface mounting boxes 3. Directly mounted on a wall
2) Use a Phillips screw driver to loosen the screws of the backplate on the bottom of the TR1V2 & TR2V2, lift upwards from the bottom and remove from the backplate. (see page 4)
3) આપેલા સ્ક્રૂ વડે બેકપ્લેટને દિવાલ પર સ્ક્રૂ કરો.
4) પૃષ્ઠ 2 પરના વાયરિંગ ડાયાગ્રામ મુજબ બેકપ્લેટને વાયર કરો.
5) Mount the TR1V2 & TR2V2 on the backplate making sure the pins and the backplate contacts are making a sound connection. Push the TR1V2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom. (See page 4)

TR1 TR2V2 RF Mains Switch

3

1

2

89

89

3

4

5

6

4

બટન / LED વર્ણન

આરએફ એલઇડી

Live in LED

Live out LED

મેન્યુઅલ ઓવરરાઇડ બટન

રીસેટ બટન

કનેક્ટ કરો બટન

Manual Manual Connect Connect
રીસેટ કરો

Press to activate or deactivate the Live out terminal. Hold for 3 seconds to initialise the pairing process. The RF light will flash. Press to reset the TR1 TR2V2.

Note: The connection procedure is not required as both TR1 & TR2V2 are pre-paired.

TR1 TR2V2 RF Mains Switch

5

એલઇડી વર્ણન

LED Live in LED

રંગ લાલ લીલો

વર્ણન
ત્યાં કોઈ વોલ્યુમ નથીtage on Live in terminal.
ત્યાં વોલ્યુમ છેtage on Live in terminal – Now an RF signal will be sent to the other RF Mains Switch to activate the Live out terminal.

આરએફ એલઇડી

સફેદ

ઘન સફેદ એલઇડી જે દર્શાવે છે કે થર્મોસ્ટેટ જોડાયેલ છે.
જ્યારે થર્મોસ્ટેટ ડિસ્કનેક્ટ થઈ જાય ત્યારે RF લાઇટ બમણી ફ્લેશ થશે. થર્મોસ્ટેટની જોડી તપાસો.
Note: The RF light will blink intermittently when the system is sending and receiving a signal for communication.
Note: The RF light will blink once every second when in RF pairing by holding Connect. Press Manual to exit from this state.

Live out LED Red

There has been no RF activation signal received from the other RF Mains Switch.

Green RF activation signal has been received from the other RF Mains Switch.

6

TR1 TR2V2 RF Mains Switch

To connect the TR1 TR2V2
Please note: When installing TR1 TR2V2 RF mains switches, both TR1 & TR2V2 are pre-paired. The below procedures are not required.
On TR1V2: Hold Connect for 3 seconds until RF LED flashes white. On TR2V2: Hold Connect for 3 seconds. The RF LED will begin to flash and the Live out LED will appear solid green. When connected all three LED’s will appear solid.
On TR1V2: Press Manual to exit the pairing mode.
After connecting successfully, the RF LED on both TR1V2 & TR2V2 will appear solid.

TR1 TR2V2 RF Mains Switch

7

To disconnect the TR1 TR2V2
On TR1V2: Hold Connect for 3 seconds until the RF LED flashes white. Hold Connect for 10 seconds until the Live in LED appears solid red. On TR2V2: Hold Connect for 3 seconds until the RF LED flashes white. Hold Connect for 10 seconds until the Live in & Live out LED appears solid red. On TR1V2: Press Manual to exit.
The TR1 TR2V2 are now disconnected.

8

TR1 TR2V2 RF Mains Switch

વાયરિંગ સampલેસ
Example 1 One way RF Switch: Programmer to Boiler – Mains Switching

TR1V2

TR2V2

a.) On TR1 When Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.

b.) On TR2 The COM & Live out contact closes, sending 230V to activate the boiler.

Programmer Live Live in out COM N/C
NL 1 2 3 4

Boiler Live Live
in out COM N/C
NL 1 2 3 4

ઇન્સ્ટોલેશન નોંધો

1. Mains Switching Boiler

On the TR2V2

- L ને 3 સાથે લિંક કરો.

2. લો વોલ્યુમtage Switching Boiler On the boiler PCB – Remove the external controls link.

On the TR2V2

– Connect terminals 2 & 3 to the external controls terminals on the

boiler PCB.

TR1 TR2V2 RF Mains Switch

9

Example 2 Two way RF Switch: 1) Programmer to Motorised Valve

2) Motorised Valve to Boiler – Mains Switching

TR1V2

TR2V2

a.) On TR1 When Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.
c.) On TR1 Live out contact closes, sending 230V to activate the boiler.

b.) On TR2 The COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TR1.

પ્રોગ્રામર

બોઈલર

Live Live in out COM N/C

NL 1 2 3 4

સહાયક

વાલ્વ

Switch Live Live

in out COM N/C

NL 1 2 3 4

ઇન્સ્ટોલેશન નોંધો

1. Mains Switching Boiler

On the TR1V2

- L ને 3 સાથે લિંક કરો.

2. લો વોલ્યુમtage Switching Boiler On the boiler PCB – Remove the external controls link.

On the TR1V2

– Connect terminals 2 & 3 to the external controls terminals on the

boiler PCB.

3. Motorised Valve

On the TR2V2

– Link L to 3 to power the Live out terminal to the motorised valve.

10

TR1 TR2V2 RF Mains Switch

Example 3 One way RF Switch: Pump Overrun – Mains Switching
TR1V2
a.) On TR1 When Live in receives 230V from the boiler, TR1 sends a wireless signal to TR2.

TR2V2
b.) On TR2 The COM & Live out contact closes, sending 230V to activate the pump.

બોઈલર
Live Live in out COM N/C
NL 1 2 3 4

પંપ
Live Live in out COM N/C
NL 1 2 3 4

ઇન્સ્ટોલેશન નોંધો

પંપ

On the TR2V2

– Link L to 3 to power the Live out terminal to the pump.

TR1 TR2V2 RF Mains Switch

11

Example 4 Two way RF Switch: Pump Overrun

1) Programmer to Boiler

2) Boiler to Pump – Mains Switching

TR1V2

TR2V2

a.) On TR1 When Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.
c.) On TR1 Live out contact closes, sending 230V to activate the pump.

b.) On TR2 The COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TR1.

પ્રોગ્રામર

પંપ

Live Live in out COM N/C

NL 1 2 3 4

પંપ

બોઈલર

Overun Live Live

in out COM N/C

NL 1 2 3 4

ઇન્સ્ટોલેશન નોંધો

1. Mains Switching Boiler

On the TR2V2

- L ને 3 સાથે લિંક કરો.

2. લો વોલ્યુમtage Switching Boiler On the boiler PCB – Remove the external controls link.

On the TR2V2

– Connect terminals 2 & 3 to the external controls terminals on the

boiler PCB.

3. પંપ

On the TR1V2

– Link L to 3 to power the Live out terminal to the pump.

12

TR1 TR2V2 RF Mains Switch

Example 5 Two way RF Switch: Unvented Cylinder:

1) Programmer to High Limit Thermostat

2) Motorised Valve to Boiler – Mains Switching

TR1V2

TR2V2

a.) On TR1 When Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.
c.) On TR1 Live out contact closes, sending 230V to activate the boiler.

b.) On TR2 The COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TR1.

પ્રોગ્રામર

બોઈલર

Live Live in out COM N/C

NL 1 2 3 4

Motorised Valve Auxiliary Switch
જીવંત
in

High Limit Thermostat Live out COM N/C

NL 1 2 3 4

ઇન્સ્ટોલેશન નોંધો

1. Mains Switching Boiler

On the TR1V2

- L ને 3 સાથે લિંક કરો.

2. લો વોલ્યુમtage Switching Boiler On the boiler PCB – Remove the external controls link.

On the TR1V2

– Connect terminals 2 & 3 to the external controls terminals on the

boiler PCB.

3. High Limit Thermostat

On the TR2V2

– Link L to 3 to power the Live out terminal to the High Limit thermostat.

4. Motorised Valve

The N/O of the High Limit Themostat powers the brown cable of the motorised valve.

TR1 TR2V2 RF Mains Switch

13

EPH નિયંત્રણો IE
technical@ephcontrols.com www.ephcontrols.com/contact-us +353 21 471 8440 કૉર્ક, T12 W665
EPH નિયંત્રણો UK
technical@ephcontrols.co.uk www.ephcontrols.co.uk/contact-us +44 1933 322 072 હેરો, HA1 1BD

© 2025 EPH Controls Ltd. 2025-05-5_TR1TR2-V2_DS_PKJW

દસ્તાવેજો / સંસાધનો

EPH CONTROLS TR1V2-TR2V2 RF Mains Switch [પીડીએફ] સૂચના માર્ગદર્શિકા
TR1V2, TR2V2, TR1V2-TR2V2 RF Mains Switch, TR1V2-TR2V2, RF Mains Switch, Mains Switch, Switch

સંદર્ભો

એક ટિપ્પણી મૂકો

તમારું ઇમેઇલ સરનામું પ્રકાશિત કરવામાં આવશે નહીં. જરૂરી ક્ષેત્રો ચિહ્નિત થયેલ છે *