Product Information: ISC-1782 Power and I/O Accessory for ISC-178x Smart Cameras
The Power and I/O Accessory for ISC-178x Smart Cameras is a terminal block designed to simplify power and I/O signal configuration for the ISC-178x Smart Camera. It has six spring terminals that are labeled for different functionalities, such as isolated inputs, isolated outputs, lighting controller, camera connector, 24V IN connector, and 24V OUT spring terminals. The accessory has three different grounds for the spring terminals labeled C, CIN, and COUT. The spring terminals with the same label are connected internally, but C, CIN, and COUT are not connected to each other. Users can wire different grounds together to share a power supply between the smart camera and the inputs or outputs.
Product Usage Instructions: ISC-1782 Power and I/O Accessory ISC-178x Smart Cameras
Ihe Ị Kwesịrị Ịmalite:
- The ISC-1782 Power and I/O Accessory
- A cable included with the accessory
- Ọkụ ọkụ
- A power source
- The ISC-178x Smart Camera
Installing the Power and I/O Accessory:
- Connect the included cable to the Camera connector on the Power and I/O Accessory and the Digital I/O and Power connector on the ISC-178x Smart Camera. Ịkpachara anya: Emetụkwala ntụtụ njikọ ndị ekpughere ekpughere.
- Connect the power supply to the 24 V IN connector on the Power and I/O Accessory.
- Jikọọ ọkọnọ ike na isi iyi ike.
Wiring Isolated Inputs:
The following images show how to wire the isolated input spring terminals of the Power and I/O Accessory.
Mara: Isolated inputs have a built-in current limit on the smart camera. It is not usually necessary to use a current-limiting resistor on input connections. Refer to the documentation of the connected device to ensure that the maximum input current limit of the smart camera does not exceed the current capability of the connected output.
Sinking Configuration:
When wiring an isolated input in a sinking configuration to a sourcing output, follow the steps below:
- Connect the sourcing output of the device to IN.
- Connect the ground signal of the device to CIN.
- Connect the common ground between the device and the Power and I/O Accessory to C.
Mara: Connecting CIN to a ground signal in a sinking output configuration will result in a short circuit.
Sourcing Configuration:
When wiring an isolated input in a sourcing configuration to a sinking output, follow the steps below:
- Connect the sinking output of the device to IN.
- Connect the power supply to 24V OUT.
- Connect the common ground between the device and the Power and I/O Accessory to C.
Wiring Isolated Outputs:
Some configurations require a pull-up or current-limiting resistor on each output. When using resistors, refer to the following guidelines.
Na-eme ka oghere dị n'etiti onye nrụpụta na sistemu ule ihe nketa gị.
ỌRỤ MMỤTA
Anyị na-enye ọrụ nrụzi na nhazigharị asọmpi, yana akwụkwọ dị mfe ịnweta yana akụrụngwa enwere ike ibudata n'efu. Autient M9036A 55D Ọnọdụ C 1192114
Tụgharịa ree Mgbakwunye gị
Anyị na-azụta akụkụ ọhụrụ, ejirila, decommissioned na gbakwunyere akụkụ nke usoro NI ọ bụla. Anyị na-emepụta ihe ngwọta kachasị mma iji gboo mkpa gị n'otu n'otu.
- Na-ere Maka Ego Ego
- Nweta kredit
- Nweta nkwekọrịta ahia ahia
OBSOLETE NI HARDWARE dị na ngwaahịa & dị njikere ibupu
Anyị na-echekwa Ọhụrụ, Mgbakwunye Ọhụrụ, Nrụzigharị, yana Ngwa Niile emegharịrị.
1-800-915-6216
www.apexwaves.com
sales@apexwaves.com
Ụghalaahịa niile, ụdị na aha aha bụ ihe nke ndị nwe ha.
Rịọ Quote PỊA EBE A USB-6216
Power and I/O Accessory
For ISC-178x Smart Cameras
The Power and I/O Accessory for ISC-178x Smart Cameras (Power and I/O Accessory) is a terminal block that simplifies power and I/O signal configuration for the ISC-178x Smart Camera.
This document describes how to install and operate the Power and I/O Accessory.
Figure 1. Power and I/O Accessory for ISC-178x Smart Cameras
- 24V IN connector
- 24V OUT spring terminals
- Isolated inputs spring terminals
- Isolated outputs spring terminals
- Lighting controller spring terminals
- Njikọ igwefoto
The Power and I/O Accessory has the following features:
- 12-pin A-coded M12 connector
- Spring terminals for each ISC-178x Smart Camera I/O signal
- Spring terminals for 24 V output
- User-replaceable fuses for accessory power, isolated outputs, and the lighting controller
- Built-in DIN rail clips for easy mounting
Ihe Ị Kwesịrị Ịmalite
- Power and I/O Accessory for ISC-178x Smart Camera
- Igwefoto Smart ISC-178
- A-Code M12 to A-Code M12 Power and I/O Cable, NI part number 145232-03
- Power Supply, 100 V AC to 240 V AC, 24 V,1.25 A, NI part number 723347-01
- 12-28 AWG waya
- Waya cutter
- Ihe mgbochi eriri waya
For more information about using the Power and I/O Accessory with the ISC-178x Smart Camera, refer to the following documents on ni.com/manuals.
- ISC-178x User Manual
- ISC-178x Getting Started Guide
Installing the Power and I/O Accessory
Complete the following steps to install the Power and I/O Accessory:
- Connect the included cable to the Camera connector on the Power and I/O Accessory and the Digital I/O and Power connector on the ISC-178x Smart Camera.
Ịkpachara anya, emetụla ntụtụ njikọ ndị ekpughere anya. - Connect signal wires to the spring terminals on the Power and I/O Accessory:
- Strip 1/4 in. of insulation from the signal wire.
- Depress the lever of the spring terminal.
- Fanye waya n'ime ọnụ.
Refer to the spring terminal labels and the Signal Descriptions section for a description of each signal.
Ịkpachara anya Do not connect input voltages greater than 24 VDC to the Power and I/O Accessory. Input voltages greater than 24 VDC can damage the accessory, all devices connected to it, and the smart camera. National Instruments is not liable for damage or injury resulting from such misuse.
- Connect the power supply to the 24 V IN connector on the Power and I/O Accessory.
- Jikọọ ọkọnọ ike na isi iyi ike.
Wiring the Power and I/O Accessory
ISC-178x Isolation and Polarity
The Power and I/O Accessory has three different grounds for the spring terminals labeled C, CIN, and COUT. The spring terminals with the same label are connected internally, but C, CIN, and COUT are not connected to each other. Users can wire different grounds together in order to share a power supply between the smart camera and the inputs or outputs.
Rịba ama To achieve functional isolation, users must maintain isolation when wiring the accessory.
Some wiring configurations may cause the polarity to appear inverted at the receiver. Users can invert the signal in the smart camera software to provide the intended polarity.
Wiring Isolated Inputs
The following images show how to wire the isolated input spring terminals of the Power and I/O Accessory.
Rịba ama Isolated inputs have a built-in current limit on the smart camera. It is not usually necessary to use a current-limiting resistor on input connections. Refer to the documentation of the connected device to ensure that the maximum input current limit of the smart camera does not exceed the current capability of the connected output.
Figure 2. Wiring Isolated Input (Sinking Configuration) to Sourcing Output
Caution Connecting CIN to a ground signal in a sinking output configuration will result in a short circuit.
Figure 3. Wiring Isolated Input (Sinking Configuration) to Sinking Output
Wiring Isolated Outputs
Some configurations require a pull-up or current-limiting resistor on each output. When using resistors, refer to the following guidelines.
Ịkpachara anya Failure to follow these guidelines may result in damage to the smart camera, connected devices, or resistors.
- Do not exceed current sink capability of the isolated outputs of the smart camera.
- Do not exceed the current source or sink capability of the connected devices.
- Do not exceed the power specification of the resistors.
Rịba ama For most applications, NI recommends a 2 kΩ 0.5 W pull-up resistor. Refer to the documentation of the connected input device to ensure this resistor value is suitable for that device.
Rịba ama Resistors with a rating less than 2 kΩ can be used for faster rise times. Users must take care not to exceed the current sink limit of the smart camera or the connected device.
The following images show how to wire the isolated output spring terminals of the Power and I/O Accessory.
Figure 4. Wiring Isolated Output to Sinking Input
Figure 5. Wiring Isolated Output to Sourcing Input
Rịba ama A resistor may not be necessary for every sourcing input device. Refer to the documentation for the connected sourcing input device to verify resistor requirements.
Wiring the Lighting Controller
The following images show how to wire a lighting controller to the Power and I/O Accessory. The TRIG terminal connects only to the V terminal through a built-in 2 kΩ pull-up resistor. To use the TRIG terminal, users must wire the terminal to the output signal generating the trigger. Any isolated output may be used as the trigger signal.
Rịba ama Review the power requirements for the lighting controller to ensure that the power supply is sufficient to power both the smart camera and the lighting controller.
Figure 6. Wiring the Lighting Controller using Isolated Output as Trigger
Figure 7. Wiring the Lighting Controller without Trigger
Forcing the Real-Time ISC-178x into Safe Mode
Users can wire the Power and I/O Accessory to force the ISC-178x to boot into safe mode. Safe mode launches only the services necessary for updating the smart camera configuration and installing software.
Rịba ama Users can only force Real-Time smart cameras to boot into safe mode. Windows smart cameras do not support safe mode.
- Power down the Power and I/O Accessory.
- Wire the accessory as shown in the following figure.
Figure 8. Wiring to Force Safe Mode
- Power on the accessory to boot the ISC-178x into safe mode.
Ịpụ na Ọnọdụ Nchekwa
Follow these steps to restart the ISC-178x in normal operating mode.
- Power down the Power and I/O Accessory.
- Disconnect the wire to the IN3 spring terminal
- Power on the accessory to restart the ISC-178x.
Nnwale na Dochie Fuses
The Power and I/O Accessory has replaceable fuses and includes one additional fuse of each type.
Figure 9. Fuse Locations
- Isolated output fuses, 0.5 A
- Spare 0.5 A fuse
- ANLG terminal fuse, 0.1 A
- Spare 2 A fuse
- ICS 3, V terminal fuse, 10 A
- Spare 10 A fuse
- Spare 0.1 A fuse
- Camera V terminal, 2 A
Table 1. Power and I/O Accessory Fuses
Protected Signal | Ndochi Fuse Quantity | Littelfuse Part Number | Fuse Description |
ICS 3, V terminal | 1 | 0448010.MR | 10 A, 125 V NANO2 ® Fuse, 448 series, 6.10 × 2.69 mm |
Camera V terminal | 1 | 0448002.MR | 2 A, 125 V NANO2 ® Fuse, 448 series, 6.10 × 2.69 mm |
Protected Signal | Ndochi Fuse Quantity | Littelfuse Part Number | Fuse Description |
Isolated outputs | 1 | 0448.500MR | 0.5 A, 125 V NANO2 ® Fuse, 448 series, 6.10 × 2.69 mm |
ANLG terminal | 1 | 0448.100MR | 0.1 A, 125 V NANO2 ® Fuse, 448 series, 6.10 × 2.69 mm |
Rịba ama You can use a handheld DMM to verify the continuity of a fuse.
Complete the following steps to replace a blown fuse:
- Kwupu ọkụ ọkụ.
- Remove all signal wires and cables from the Power and I/O Accessory.
- Remove a side panel. Use a Phillips head screwdriver to remove the 2 retaining screws.
- Slide the circuit board out.
- Replace any blown fuses with an equivalent replacement fuse. Replacement fuses are labelled as SPARE on the circuit board.
Nkọwa mgbaàmà
Refer to the ISC-178x Smart Camera User Manual for detailed signal descriptions.
ISC-178x ike na njikọ I/O Pinout
Table 2. ISC-178x Power and I/O Connector Signal Descriptions
Ntụtụ | Signal | Nkọwa |
1 | Ọnụ ego | Ntụaka nkịtị (na-adịghị mma) maka mpụta dịpụrụ adịpụ |
2 | Analọg pụtara | Mmepụta ntụaka analog maka njikwa ọkụ |
3 | Ọpụpụ 2+ | Mbupụta dịpụrụ adịpụ (nke ọma) |
4 | V | Sistemu ike voltage (24 VDC ± 10%) |
5 | Isi na 0 | Ntinye dịpụrụ adịpụ na ebumnuche izugbe |
6 | CIN | Ntụaka nkịtị (nke dị mma ma ọ bụ adịghị mma) maka ntinye dịpụrụ adịpụ |
7 | Isi na 2 | Ntinye dịpụrụ adịpụ na ebumnuche izugbe |
8 | Isi na 3 | (NI Linux Real-Time) Reserved for safe mode (Windows) General-purpose isolated input |
9 | Isi na 1 | Ntinye dịpụrụ adịpụ na ebumnuche izugbe |
10 | Ọpụpụ 0+ | Mbupụta dịpụrụ adịpụ (nke ọma) |
11 | C | Ike sistemu na ntụaka analọg nkịtị |
12 | Ọpụpụ 1+ | Mbupụta dịpụrụ adịpụ (nke ọma) |
Table 3. Power and I/O Cables
Igwe eriri | Ogologo | Nọmba akụkụ |
A-koodu M12 ka A-Code M12 Ike na I/O USB | 3 m | 145232-03 |
A-koodu M12 na ike Pigtail na eriri I/O | 3 m | 145233-03 |
Nlekọta gburugburu ebe obibi
NI agba mbọ n'ichepụta na imepụta ngwaahịa n'ụzọ doro anya na gburugburu ebe obibi. NI ghọtara na iwepụ ụfọdụ ihe dị ize ndụ na ngwaahịa anyị bara uru na gburugburu ebe obibi yana ndị ahịa NI.
Maka ozi gbasara gburugburu ebe obibi ndị ọzọ, rụtụ aka na Wedata Mmetụta Gburugburu Ebe Obibi Anyị web ibe na ni.com/environment. Ibe a nwere ụkpụrụ gburugburu ebe obibi na ntuziaka nke NI na-akwado, yana ozi gburugburu ebe obibi ndị ọzọ etinyeghị n'ime akwụkwọ a.
Ngwa eletriki na eletrọnịkị na-ekpofu ihe (WEEE)
Ndị ahịa EU Na njedebe nke usoro ndụ ngwaahịa, ngwaahịa NI niile ga-ekpochapụ dịka iwu na ụkpụrụ obodo siri dị. Maka ozi ndị ọzọ gbasara otu esi emegharị ngwaahịa NI na mpaghara gị, gaa na ni.com/environment/weee.
National Instruments National InstrumentsRoHS
ni.com/environment/rohs_china(Maka ozi gbasara nnabata China RoHS, gaa na ni.com/environment/rohs_china.)
Ozi nwere ike ịgbanwe na-enweghị ọkwa. Rụtụ aka na ụghalaahịa NI na ntuziaka akara akara na ni.com/trademarks maka ozi gbasara ụghalaahịa NI. Ngwaahịa na aha ụlọ ọrụ ndị ọzọ a kpọtụrụ aha n'ebe a bụ ụghalaahịa ma ọ bụ aha azụmaahịa nke ụlọ ọrụ ha. Maka ikike ikike kpuchiri ngwaahịa/teknụzụ NI, rụtụ aka n'ebe kwesịrị ekwesị: Enyemaka»Ikikere dị na ngwa ngwa gị, na patent.txt file na mgbasa ozi gị, ma ọ bụ National Instruments Patent Notice na ni.com/patent. Ị nwere ike ịchọta ozi gbasara nkwekọrịta ikike onye ọrụ njedebe (EULA) na ọkwa iwu nke ndị ọzọ na readme file maka ngwaahịa NI gị. Rụtụ aka na ozi nnabata mbupụ na ni.com/legal/export-compliance maka iwu nrube isi ahia zuru ụwa ọnụ NI yana otu esi enweta koodu HTS dị mkpa, ECN, yana data mbubata / mbupu ndị ọzọ. NI NA-eme ka ọ dịghị nkwupụta ma ọ bụ KWESỊRỊ KWESỊRỊ KA EZIOKWU nke ozi dị n'ime ebe a na agaghị aza maka njehie ọ bụla. Ndị ahịa Gọọmenti US: E mepụtara data dị n'akwụkwọ ntuziaka a n'ego nkeonwe ma dabere na ikike nwere oke yana ikike data amachibidoro dị ka ewepụtara na FAR 52.227-14, DFAR 252.227-7014, na DFAR 252.227-7015.
© 2017 Ngwa ngwa mba. Ikike niile echekwabara.
376852B-01 May 4, 2017
Akwụkwọ / akụrụngwa
![]() |
NATIONAL INSTRUMENTS Power and Input or Output Accessory for ISC-178x Smart Cameras [pdf] Akwụkwọ ntuziaka onye ọrụ ISC-178x, ISC-1782, Power and Input or Output Accessory for ISC-178x Smart Cameras, Power and Input or Output Accessory, ISC-178x Smart Cameras |