The RM51 Remote is used to program the configurations of the Keilton Basic sensors using infrared (IR) communications with the devices. It offers 6 default modes of configurations plus manual settings. Customer configurations can be created, saved, and then sent to each device, ensuring a rapid deployment.
Mga bahin
- Ubos nga konsumo sa kuryente.
- Infrared communication.
- Setting most of the Keilton Sensors G2.
- Custom Configurations can be saved to A, B, C, D, or For.
- 40′ maximum IR range.
- RML (included with new orders, available as an accessory for order), installed, will increase the IR range. (See table below)
Mga detalye

Impormasyon sa Pag-order
| Modelo | Deskripsyon |
| RM51.A0 | Basic Sensor Controller RM51 |
| RM51.A1 | Basic Sensor Controller RM51 With RML |
Impormasyon sa Pag-order - Mga Kagamitan
| Modelo | Deskripsyon |
| RML | Extended IR range for commissioning |
Mga sukat

Label sa Produkto

Hilit nga mga Instruksyon
Memory Mode (Pagkomisyon)
To begin commissioning, follow these steps:
- Pagpili og memory profile: A, B, C, D, o E.
- The remote’s indicator lights will flash, indicating the currently saved settings.
- Settings can be configured by pressing the appropriate buttons in the highlighted gray area of the remote (TRIM-LEVEL, SENSITIVITY, HOLD TIME, STANDBY DIM, STANDBY TIME, and PHOTOCELL). Review the selected settings and make changes as needed.
- Point the remote at the desired luminaire and press “SEND.”
- The luminaire will flash twice to confirm that he settings are saved. Changing a parameter in a memory profile will automatically override previous settings.
- If configuring multiple luminaires, repeat steps 4 and 5 after selecting the configured memory mode.
E Mode allows for visual adjustment to choose the desired dimming level.
Pag-ani sa Adlaw (F Mode)
Continuous Adjustment Mode adjusts dimming levels based on daylight.
- Point the remote at the desired luminaire and press “ON,” then press DIM+ or DIM- to adjust the dimming level.
- Press “F.” The indicator lights on the remote will show the current saved settings. Note: Only TRIM-LEVEL, SENSITIVITY, and HOLD TIME can be selected for Daylight Harvesting settings
- Review the selected settings and make changes as necessary. Press “SEND.”
- If the configuration is successful, the luminaire will flash twice to confirm that the setting is saved. If configuring multiple luminaires, select the configured Daylight Harvesting settings, then follow steps 1, 2, and 3.

Dugang nga Remote Function
| ON | Milingi ON mga luminaire. |
| OFF | Milingi OFF mga luminaire. |
|
PAGSULAY |
The fixture enters the test mode and exits automatically after 5 minutes. The test mode parameters are configured as follows: Trim-level: 100%, Pagkasensitibo: TAAS, Panahon sa pagpugong: 2s, Standby dim: 50%, Panahon sa standby: 2s. |
| RESET | Trim= 100%, Sensitivity = Taas, T1 = 5 min, Standby Dim = 30%, T2 = 60 min,
Photocell = OFF. |
| DIM+/- | Press Dim+ or Dim- to adjust brightness in 0.5V increments. Hold the button for continuous
pagkalawos |
| PAGTULONG-LEVEL | Set the Maximum brightness. |
| SENSIBILIDAD | Set the motion sensitivity of the sensor UBOS:50% / TAAS:100%,
PATAY: disable the motion detection function. |
| HOLDTIME | Ang gidugayon nga molabay nga walay occupancy detection sa dili pa mobalhin ngadto sa standby dim. |
| STANDBY DIM | Select any standby dim level. |
| STANDBY PANAHON | Standby time, when the time is set to “∞”, the daylight detection function is activated. |
| PHOTOCELL | visible light threshold, the fixture is allowed to be turned on when it falls below the threshold
UBOS:5fc / TAAS:20fc, CAL: Collect the current visible light illuminance as the threshold, PATAY: disable PHOTOCELL function. |
| MODE | Default configuration parameters for modes A sa F. |
| IPADALA | Ipadala ang mga setting sa sensor. |
| DEFAULT MODA A | Trim= 100%, Sensitivity = Ubos, T1 = 30 min, Standby Dim = 50%, T2 = ∞, Photocell = CAL. |
| DEFAULT MODE B | Trim= 100%, Sensitivity = Ubos, T1 = 30 min, Standby Dim = 50%, T2 = 15 min, Photocell = CAL. |
| DEFAULT MODE C | Trim= 100%, Sensitivity = Ubos, T1 = 30 min, Standby Dim = 50%, T2 = 15 min, Photocell = OFF. |
| DEFAULT MODE D | Trim= 50%, Sensitivity = Ubos, T1 = 30 s, Standby Dim = 50%, T2 = 30 min, Photocell = CAL. |
| DEFAULT MODE E | Manual Dimmer Mode, Trim 100%. |
| DEFAULT MODE F | Daylight Harvesting, Trim= 50%, Sensitivity = Ubos, T1 = 15 min. |
Kontaka Kami
- 7001 Columbia Gateway Drive, Suite 210, Columbia, MD 21046, USA
- T: +1 443-320-2233 (M-F 9 am-5 pm ET)
- E: support@autani.com
FAQ
How do I change the memory profile mga setting?
Select the desired memory profile on the remote and adjust settings as needed before pressing SEND to save
Can I configure Daylight Harvesting settings for multiple luminaires simultaneously?
No, you need to configure Daylight Harvesting settings for each luminaire individually using the F Mode on the remote.
What is the expected operation if the user sets Standby Time to something other than INFINITE?
moiton -> the intensity of ambient light is lower than the threshold set by the PC->turn on the light and dim to trim-level->t1 timeout->dim to standby dim ->t2 timeout->turn off the light.
If it does not turn OFF the fixture, why would Mode B and D use CAL as the default?
The ambient light intensity stored by CAL will serve as the threshold for turning on the lights, but it has no connection with the function of turning off the lights.
Mga Dokumento / Mga Kapanguhaan
![]() |