Télécommande Keilton Basic RM51 pour capteur de luminaire

Description
The RM51 Remote is used to program the configurations of the Keilton Basic sensors using infrared (IR) communications with the devices. It offers 6 default modes of configurations plus manual settings. Customer configurations can be created, saved, and then sent to each device, ensuring a rapid deployment.
Caractéristiques
- Faible consommation d'énergie.
- Infrared communication.
- Setting most of the Keilton Sensors G2.
- Custom Configurations can be saved to A, B, C, D, or For.
- 40′ maximum IR range.
- RML (included with new orders, available as an accessory for order), installed, will increase the IR range. (See table below)
Caractéristiques

Informations de commande
| Modèle | Description |
| RM51.A0 | Basic Sensor Controller RM51 |
| RM51.A1 | Basic Sensor Controller RM51 With RML |
Informations de commande – Accessoires
| Modèle | Description |
| RML | Extended IR range for commissioning |
Dimensions

Étiquette du produit

Instructions à distance
Mode mémoire (mise en service)
To begin commissioning, follow these steps:
- Sélectionnez un professionnel de la mémoirefile:A, B, C, D ou E.
- The remote’s indicator lights will flash, indicating the currently saved settings.
- Settings can be configured by pressing the appropriate buttons in the highlighted gray area of the remote (TRIM-LEVEL, SENSITIVITY, HOLD TIME, STANDBY DIM, STANDBY TIME, and PHOTOCELL). Review the selected settings and make changes as needed.
- Point the remote at the desired luminaire and press “SEND.”
- The luminaire will flash twice to confirm that he settings are saved. Changing a parameter in a memory profile will automatically override previous settings.
- If configuring multiple luminaires, repeat steps 4 and 5 after selecting the configured memory mode.
E Mode allows for visual adjustment to choose the desired dimming level.
Récupération de la lumière du jour (mode F)
Continuous Adjustment Mode adjusts dimming levels based on daylight.
- Point the remote at the desired luminaire and press “ON,” then press DIM+ or DIM- to adjust the dimming level.
- Press “F.” The indicator lights on the remote will show the current saved settings. Note: Only TRIM-LEVEL, SENSITIVITY, and HOLD TIME can be selected for Daylight Harvesting settings
- Review the selected settings and make changes as necessary. Press “SEND.”
- If the configuration is successful, the luminaire will flash twice to confirm that the setting is saved. If configuring multiple luminaires, select the configured Daylight Harvesting settings, then follow steps 1, 2, and 3.

Fonctions supplémentaires de la télécommande
| ON | Tours ON luminaires. |
| DÉSACTIVÉ | Tours DÉSACTIVÉ luminaires. |
|
TEST |
The fixture enters the test mode and exits automatically after 5 minutes. The test mode parameters are configured as follows: Trim-level: 100%, Sensibilité: HAUTE, Temps de maintien : 2s, Standby dim: 50%, Autonomie en veille : 2s. |
| RÉINITIALISER | Trim= 100%, Sensitivity = Haut, T1 = 5 min, Standby Dim = 30%, T2 = 60 min,
Photocell = DÉSACTIVÉ. |
| DIM+/- | Press Dim+ or Dim- to adjust brightness in 0.5V increments. Hold the button for continuous
atténuation |
| NIVEAU DE GARNITURE | Set the Maximum brightness. |
| SENSIBILITÉ | Set the motion sensitivity of the sensor FAIBLE:50% / HAUT:100%,
OFF: disable the motion detection function. |
| TEMPS DE MAINTIEN | La durée qui s'écoule sans détection d'occupation avant de passer en mode veille. |
| DIM EN VEILLE | Select any standby dim level. |
| VEILLE TEMPS | Standby time, when the time is set to “∞”, the daylight detection function is activated. |
| PHOTOCELLULE | visible light threshold, the fixture is allowed to be turned on when it falls below the threshold
FAIBLE:5fc / HAUT:20fc, CAL: Collect the current visible light illuminance as the threshold, OFF: disable PHOTOCELL function. |
| MODE | Default configuration parameters for modes A à F. |
| ENVOYER | Envoyer les paramètres au capteur. |
| DÉFAUT MODEA | Trim= 100%, Sensitivity = Faible, T1 = 30 min, Standby Dim = 50%, T2 = ∞, Photocell = CAL. |
| MODE PAR DÉFAUT B | Trim= 100%, Sensitivity = Faible, T1 = 30 min, Standby Dim = 50%, T2 = 15 min, Photocell = CAL. |
| MODE PAR DÉFAUT C | Trim= 100%, Sensitivity = Faible, T1 = 30 min, Standby Dim = 50%, T2 = 15 min, Photocell = DÉSACTIVÉ. |
| MODE PAR DÉFAUT D | Trim= 50%, Sensitivity = Faible, T1 = 30 s, Standby Dim = 50%, T2 = 30 min, Photocell = CAL. |
| MODE PAR DÉFAUT E | Manual Dimmer Mode, Trim 100%. |
| MODE PAR DÉFAUT F | Daylight Harvesting, Trim= 50%, Sensitivity = Faible, T1 = 15 min. |
Contactez-nous
- 7001 Columbia Gateway Drive, Suite 210, Columbia, MD 21046, USA
- T: +1 443-320-2233 (M-F 9 am-5 pm ET)
- E: support@autani.com
FAQ
How do I change the memory profile paramètres?
Select the desired memory profile on the remote and adjust settings as needed before pressing SEND to save
Can I configure Daylight Harvesting settings for multiple luminaires simultaneously?
No, you need to configure Daylight Harvesting settings for each luminaire individually using the F Mode on the remote.
What is the expected operation if the user sets Standby Time to something other than INFINITE?
moiton -> the intensity of ambient light is lower than the threshold set by the PC->turn on the light and dim to trim-level->t1 timeout->dim to standby dim ->t2 timeout->turn off the light.
If it does not turn OFF the fixture, why would Mode B and D use CAL as the default?