HOVERTECH HoverMatt SPU Setengah Matt
Referensi Simbol
CE MARKING OF KESESUAIAN
UK MARKING OF selaras
PERWAKILAN WEH
UK TANGGUNGJAWAB wong
SWITZERLAND WEH PERWAKILAN
AWAS / WARNING
IMPORTER
PEMBUANGAN
PETUNJUK OPERASI
MANUAL CLEANING
KUNCI ALL RODA
JAMINAN PASIEN WATA
PASIEN PUSAT
LAMPIRAN LINK
LATEX GRATIS
NOMOR LOT
PRODUSEN
TANGGAL PRODUKSI
piranti MEDIS
PATIENT SINGLE - GUNA GANDA
AJA LAUNDER
IDENTIFIER PERANGKAT UNIK
Watesan bobot pasien
NGANGGO KAREGIVES loro
PANGGUNAAN TETUNG KANGGO
PENDEKATAN TUTUP
KEMPIS, NGANGKAT RIL
LOOP STYLE HANGER BAR
KECEPATAN TALI PASIEN (GASUNG)
KECEPATAN TALI PASIEN (VELCRO®)
KAKI END
NOMOR MODEL
Nomer SERial
Gunakake lan Pancegahan
PENGGUNAAN INTENDED
Sistem Transfer Udara HoverMatt® digunakake kanggo nulungi para pengasuh kanthi transfer pasien, posisi (kalebu ningkatake lan ngowahi), lan proning. HoverTech Air Supply inflates HoverMatt kanggo bantal lan cradle sabar, nalika udhara bebarengan oncat saka bolongan ing underside, ngurangi pasukan needed kanggo mindhah sabar dening 80-90%.
INDIKASI
- Pasien ora bisa nulungi transfer lateral dhewe.
- Patients kang bobot utawa girth nuduhke resiko kesehatan potensial kanggo caregiver tanggung jawab kanggo repositioning utawa laterally nransfer pasien ngandika.
KONTRAINDIKASI
- Pasien sing ngalami fraktur thoracic, serviks utawa lumbar sing dianggep ora stabil ora kudu nggunakake HoverMatt kajaba keputusan klinis wis digawe dening fasilitas sampeyan.
SETTINGS CARE INTENDED
- Rumah sakit, fasilitas perawatan jangka panjang utawa lengkap.
PENCEGAHAN – SUPPLY UDARA
- Ora digunakake ing ngarsane anestesi sing gampang kobong utawa ing kamar hiperbarik utawa kemah oksigen.
- Rute kabel listrik kanthi cara kanggo njamin bebas saka bebaya.
- Aja ngalangi asupan udara saka pasokan udara.
- Nalika nggunakake HoverMatt ing lingkungan MRI, selang MRI khusus 25 ft dibutuhake (kasedhiya kanggo tuku).
Nyingkiri kejut listrik. Aja mbukak pasokan udara.
Referensi manual pangguna khusus produk kanggo instruksi operasi.
Pancegahan - HOVERMATT
- Pengasuh kudu verifikasi manawa kabeh rem wis aktif sadurunge ditransfer.
- Gunakake minimal rong pengasuh sajrone transfer pasien lateral sing dibantu udara.
- Kanggo tugas posisi sing dibantu udara ing amben, luwih saka siji pengasuh bisa uga dibutuhake.
- Kanggo proning dibantu udhara, deleng video latihan ing www.HoverMatt.com.
- Aja ninggalake pasien tanpa dijaga ing piranti sing diobong.
- Gunakake prodhuk iki mung kanggo tujuane kaya sing diterangake ing manual iki.
- Mung nggunakake lampiran lan/utawa aksesoris sing sah dening HoverTech.
- Nalika mindhah menyang lan saka amben online mundhut kurang, nyetel aliran udara kasur amben kanggo tingkat paling dhuwur kanggo lumahing transfer tenan.
- Aja nyoba mindhah pasien ing HoverMatt sing ora diobong.
Rel sisih kudu diangkat karo siji pengasuh.
Ing OR - Kanggo nyegah pasien saka slipping, tansah deflate HoverMatt lan ngamanake sabar lan HoverMatt menyang meja UTAWA sadurunge mindhah meja menyang posisi angled.
Pandhuan kanggo Gunakake
Pandhuan kanggo Gunakake - HoverMatt® * lan HoverMatt® SPU
- Pasien kudu ing posisi supine.
- Selehake HoverMatt ing sangisore pasien kanthi nggunakake teknik gulung log lan ngamanake tali pasien kanthi longgar.
- Tancepake kabel listrik HoverTech Air Supply menyang stopkontak.
- Lebokake nozzle selang menyang salah siji saka rong katup intake ing mburi sikil HoverMatt - sworo seru menyang panggonan lan tutup tutup.
- Mesthekake yen lumahing transfer sabisa lan ngunci kabeh gembong.
- Yen bisa, pindhah saka permukaan sing luwih dhuwur menyang permukaan sing luwih murah.
- Nguripake HoverTech Air Supply.
- Push HoverMatt ing sudhut, salah siji headfirst utawa feetfirst. Sawise setengah dalan, pengasuh sing ngelawan kudu nyekel gagang sing paling cedhak lan narik menyang lokasi sing dikarepake.
- Priksa manawa pasien fokus ing nampa peralatan sadurunge deflasi.
- Pateni pasokan udara lan angkat rel amben / tandu. Bukak tali pasien.
CATETAN: Nalika nggunakake HoverMatt karo pasien sing ukurane utawa nalika luwih akeh angkat dibutuhake, rong pasokan udara bisa digunakake kanggo inflasi.
* Bisa digunakake maneh.
Pandhuan kanggo Gunakake - Link HoverMatt® SPU
LAMPIRAN ING BEDFRAME
- Copot tali Link saka kanthong lan longgar masang menyang TCTerms ngalangi ing pigura amben kanggo ngidini Link SPU kanggo pindhah karo sabar.
- Sadurunge transfer lateral lan posisi, copot tali Link saka pigura amben lan simpen ing kanthong panyimpenan sing cocog.
TRANSFER LATERAL
- Pasien kudu ing posisi supine.
- Selehake HoverMatt SPU Link ing ngisor pasien kanthi nggunakake teknik gulung log lan aman tali pasien kanthi longgar.
- Tancepake kabel listrik HoverTech Air Supply menyang stopkontak.
- Lebokake muncung selang menyang salah siji saka rong katup intake ing mburi sikil HoverMatt SPU Link lan sworo seru ing panggonane lan tutup tutup.
- Mesthekake yen lumahing transfer sabisa lan ngunci kabeh gembong.
- Yen bisa, pindhah saka permukaan sing luwih dhuwur menyang permukaan sing luwih murah.
- Nguripake HoverTech Air Supply.
- Push HoverMatt SPU Link ing sudhut, salah siji headfirst utawa feetfirst. Sawise setengah dalan, pengasuh sing ngelawan kudu nyekel gagang sing paling cedhak lan narik menyang lokasi sing dikarepake.
- Priksa manawa pasien fokus ing nampa peralatan sadurunge deflasi.
- Pateni pasokan udara lan angkat rel amben / tandu. Bukak tali pasien.
- Copot tali Link saka kanthong lan longgar masang menyang titik ngalangi ing pigura amben.
CATETAN: Nalika nggunakake HoverMatt karo pasien sing ukurane utawa nalika luwih akeh angkat dibutuhake, rong pasokan udara bisa digunakake kanggo inflasi.
Pandhuan kanggo Gunakake - HoverMatt® SPU Split-Leg
POSISI LITOMI
- Pisahake sikil dadi rong bagean kanthi nyopot snaps.
- Posisi saben bagean ing meja kanthi sikil pasien.
TRANSFER LATERAL
- Priksa manawa kabeh jepretan sing ana ing bagian tengah lan sikil disambungake.
- Pasien kudu ing posisi supine.
- Selehake HoverMatt SPU Split-Leg ing ngisor pasien nggunakake teknik gulung log lan tali pasien sing aman.
- Pasang kabel listrik HoverTech Air Supply menyang stopkontak.
- Lebokake nozzle selang menyang salah siji saka rong katup intake sing ana ing mburi sikil HoverMatt SPU Split-Leg, lan sworo seru ing panggonane.
- Mesthekake yen lumahing transfer sabisa lan ngunci kabeh gembong.
- Yen bisa, pindhah saka permukaan sing luwih dhuwur menyang permukaan sing luwih murah.
- Nguripake HoverTech Air Supply.
- Push HoverMatt SPU Split-Leg ing sudhut, salah siji headfirst utawa feetfirst. Sawise setengah dalan, pengasuh sing ngelawan kudu nyekel gagang sing paling cedhak lan narik menyang lokasi sing dikarepake.
- Priksa manawa pasien fokus ing nampa peralatan sadurunge deflasi.
- Pateni HoverTech Air Supply lan mundhakaken rel amben / tandu. Bukak tali pasien.
- Nalika HoverMatt SPU Split-Leg wis deflated, posisi saben bagean wentis minangka cocok.
Pandhuan kanggo Gunakake - HoverMatt® Half-Matt* lan HoverMatt® SPU Half-Matt
- Pasien kudu ing posisi supine.
- Selehake HoverMatt Half-Matt ing ngisor pasien kanthi nggunakake teknik gulung log lan tali pasien sing aman.
- Tancepake kabel listrik HoverTech Air Supply menyang stopkontak.
- Lebokake muncung selang menyang salah siji saka rong katup intake ing mburi sikil HoverMatt lan pasang ing panggonane.
- Mesthekake yen lumahing transfer sabisa lan ngunci kabeh gembong.
- Yen bisa, pindhah saka permukaan sing luwih dhuwur menyang permukaan sing luwih murah.
- Nguripake HoverTech Air Supply.
- Push HoverMatt Half-Matt ing sudhut, salah siji headfirst utawa feetfirst. Sawise setengah dalan, pengasuh sing ngelawan kudu nyekel gagang sing paling cedhak lan narik menyang lokasi sing dikarepake. Priksa manawa caregiver ing mburi sikil nuntun sikil pasien sajrone transfer.
- Priksa manawa pasien fokus ing nampa peralatan sadurunge deflasi.
- Pateni HoverTech Air Supply lan angkat rel amben / tandu. Bukak tali pasien.
PENCEGAHAN: Gunakake minimal telu caregiver sak udhara-Bantuan PATIENT TRANSFER LATERAL nalika nggunakake HOVERMATT HALF-MATT lan HOVERMATT SPU HALF-MATT.
Pandhuan kanggo Gunakake - HoverMatt® SPU karo HoverCover
- Pasien kudu ing posisi supine.
- Selehake HoverMatt SPU karo HoverCover ing ngisor pasien nggunakake teknik gulung log lan tali pasien sing aman.
- Tancepake kabel listrik HoverTech Air Supply menyang stopkontak.
- Lebokake muncung selang menyang salah siji saka rong katup intake ing mburi sikil HoverMatt lan pasang ing panggonane.
- Mesthekake yen lumahing transfer sabisa lan ngunci kabeh gembong.
- Yen bisa, pindhah saka permukaan sing luwih dhuwur menyang permukaan sing luwih murah.
- Nguripake HoverTech Air Supply.
- Push HoverMatt ing sudhut, salah siji sirah utawa sikil dhisik. Sawise setengah dalan, pengasuh sing ngelawan kudu nyekel gagang sing paling cedhak lan narik menyang lokasi sing dikarepake.
- Priksa manawa pasien fokus ing nampa peralatan sadurunge deflasi.
- Pateni pasokan udara lan angkat rel amben / tandu. Bukak tali pasien.
CATETAN: Nalika nggunakake HoverMatt karo pasien sing ukurane utawa nalika luwih akeh angkat dibutuhake, rong pasokan udara bisa digunakake kanggo inflasi.
Nggunakake Sistem Transfer Udara HoverMatt® ing Kamar Operasi
HoverMatt bisa digunakake kanggo mindhah, posisi, lan reposisi pasien menyang lan saka kamar operasi. A sabar bisa ambulate menyang HoverMatt prepositioned ing kamar operasi (UTAWA) meja, utawa HoverMatt bisa disebarake ing fashion khas kanggo patients ora bisa ambulate lan / utawa sing gumantung. Sing terakhir iki biasane kedadeyan ing area penahanan preoperatif ing ngendi transfer bakal kelakon saka tandu / amben menyang meja UTAWA; iki uga bisa kedadeyan karo pasien rawat inap sing wis ana ing ndhuwur HoverMatt. Pancegahan kanggo AS ing Kamar Operasi (OR):
- Tindakake langkah-langkah sing diterangake ing manual iki (kaca 4-7) kanggo transfer paten lateral.
- Priksa manawa OR Tabel dikunci sadurunge miwiti transfer lateral.
- Priksa manawa pinggiran HoverMatt diselehake ing ngisor kasur UTAWA Tabel sawise transfer.
HoverMatt® T-Burg™ ditujokake kanggo kabeh prosedur bedhah ing ngendi pasien bisa diselehake ing Trendelenburg (utawa Reverse Trendelenburg) nganti 40 derajat, kalebu nggunakake robotika. Transfer pasien / repositioning / boosting bisa difasilitasi sadurunge lan / utawa sawise prosedur ing ngendi bobot pasien bisa nyebabake risiko ciloko. HoverMatt T-Burg dirancang kanggo nahan pasien kanthi aman ing macem-macem derajat Trendelenburg, nganti 40 derajat. HoverMatt T-Burg nduweni watesan bobot 400lb.
Kanggo informasi luwih lengkap, deleng Manual pangguna kanggo HoverMatt T-Burg.
Ing OR - Kanggo nyegah pasien saka slipping, tansah deflate HoverMatt lan ngamanake sabar lan HoverMatt menyang meja UTAWA sadurunge mindhah meja menyang posisi angled.
Identifikasi Bagean - Pasokan Udara HT-Air®
WARNING:
- HT-Air ora kompatibel karo sumber daya DC.
- HT-Air ora dienggo karo Kréta Baterei HoverJack.
Fungsi Keypad HT-Air®
Bisa diatur: Kanggo nggunakake piranti posisi sing dibantu udara HoverTech. Ana papat setelan sing beda. Saben pencet tombol nambah tekanan udara lan tingkat inflasi. LED Flashing Ijo bakal nuduhake kacepetan inflasi kanthi jumlah kelip-kelip (yaiku rong kelip-kelip padha karo kacepetan inflasi kapindho).
Kabeh setelan ing kisaran ADJUSTABLE luwih murah tinimbang setelan HoverMatt lan HoverJack. Fungsi ADJUSTABLE ora bisa digunakake kanggo transfer.
Setelan ADJUSTABLE minangka fitur safety sing bisa digunakake kanggo mesthekake pasien dipusatake ing piranti sing dibantu udhara HoverTech lan supaya bisa nglatih pasien sing isin utawa lara kanggo gangguan lan fungsi piranti sing kembung.
siyaga: Digunakake kanggo mungkasi inflasi/aliran udara (LED Amber nuduhake mode STANDBY).
HOVERMATT 28/34: Kanggo digunakake karo 28″ & 34″ HoverMatts lan HoverSlings.
HOVERMATT 39/50 & HOVERJACK: Kanggo nggunakake 39″ & 50″ HoverMatts lan HoverSlings lan 32″ & 39″ HoverJacks.
Air200G / Air400G Air Supplies
Yen nggunakake Air200G utawa Air400G Air Supplies HoverTech, pencet tombol werna abu-abu ing sisih ndhuwur tabung kanggo miwiti aliran udara. Pencet maneh tombol kanggo mungkasi aliran udara.
Spesifikasi Produk / Aksesoris sing Dibutuhake
KAMAR TRANSFER UDARA HOVERMATT® (BISA DIGUNAKAN maneh)
Bahan: | Disegel panas: Kepar nilon Dilapisi kaping pindho: Kepar nilon kanthi lapisan poliuretan ing sisih pasien |
Konstruksi: | RF-Gas |
Jembar: | 28" (71 cm), 34" (86 cm), 39" (99 cm), 50" (127 cm) |
dawa: | 78″ (198 cm) Setengah Mat: 45″ (114 cm) |
Konstruksi Ditutup Panas
- Model #: HM28HS – 28” W x 78” L
- Model #: HM34HS – 34″ W x 78″ L
- Model #: HM39HS – 39″ W x 78″ L
- Model #: HM50HS – 50″ W x 78″ L
DoubLe-Coated Construction
- Model #: HM28DC – 28” W x 78” L
- Model #: HM34DC – 34″ W x 78″ L
- Model #: HM39DC – 39″ W x 78″ L
- Model #: HM50DC – 50″ W x 78″ L
Watesan bobot 1200 LBS / 544KG
HoverMatt Setengah-Matt
- Model #: HM-Mini34HS – 34″ W x 45″ L
Konstruksi Double-Coated
- Model #: HM-Mini34DC – 34″ W x 45″ L
Watesan bobot 600 LBS / 272 KG
AKSESORI sing dibutuhake:
- Model #: HTAIR1200 (Versi Amerika Utara) – 120V~, 60Hz, 10A
- Model #: HTAIR2300 (Versi Eropa) – 230V~, 50 Hz, 6A
- Model #: HTAIR1000 (Versi Jepang) – 100V~, 50/60 Hz, 12.5A
- Model #: HTAIR2356 (Versi Korea) – 230V~, 50/60 Hz, 6A
- Model #: AIR200G (800 W) – 120V~, 60Hz, 10A
- Model #: AIR400G (1100 W) – 120V~, 60Hz, 10A
HOVERMATT® SINGLE-PATIENT nggunakake kasur UDARA TRANSFER
Bahan: | Ndhuwur: Serat polypropylene non-anyaman |
Konstruksi: | Dijahit |
Jembar: | 34″ (86 cm), 39″ (99 cm), 50″ (127 cm) |
dawa: | Beda-beda miturut produk Setengah Mat: 45" (114 cm) |
HoverMatt SPU
- Model #: HM34SPU-B – 34″ W x 78″ L (10 saben kothak)*
- Model #: HM39SPU-B – 39″ W x 78″ L (10 saben kothak)*
- Model #: HM50SPU-B – 50″ W x 78″ L (5 saben kothak)*
- Model #: HM50SPU-B-1Matt – 50″ W x 78″ L (1 Unit)*
HoverMatt SPU karo HoverCover
- Model #: HMHC-34 – 34” W x 78” L (10 saben kothak)*
- Model #: HMHC-39 – 39” W x 78” L (10 saben kothak)*
- HoverMatt SPU Split-Leg Matt
- Model #: HM34SPU-SPLIT-B – 34″ W x 70″ L (10 saben kothak)*
Link SPU HoverMatt
- Model #: HM34SPU-LNK-B – 34″ W x 78″ L (10 saben kothak)*
- Model #: HM39SPU-LNK-B – 39″ W x 78″ L (10 saben kothak)*
- Model #: HM50SPU-LNK-B – 50″ W x 78″ L (5 saben kothak)*
- Model #: HM50SPU-LNK-B-1Matt – 50” W x 78” L (1 Unit)*
Watesan bobot 1200 LBS / 544 KG
HoverMatt SPU Half-Matt
- Model #: HM34SPU-HLF-B – 34″ W x 45″ L (10 saben kothak)*
- Model #: HM39SPU-HLF-B – 39″ W x 45″ L (10 saben kothak)*
Watesan bobot 600 LBS / 272 KG
* Model ambegan
AKSESORI sing dibutuhake:
- Model #: HTAIR1200 (Versi Amerika Utara) – 120V~, 60Hz, 10A
- Model #: HTAIR2300 (Versi Eropa) – 230V~, 50 Hz, 6A
- Model #: HTAIR1000 (Versi Jepang) – 100V~, 50/60 Hz, 12.5A
- Model #: HTAIR2356 (Versi Korea) – 230V~, 50/60 Hz, 6A
- Model #: AIR200G (800 W) – 120V~, 60Hz, 10A
- Model #: AIR400G (1100 W) – 120V~, 60Hz, 10A
Reresik lan Nyegah Maintenance
HOVERMATT CLEANING AND MAINTENANCE (MUNG BISA DIGUNAKAN maneh)
Ing antarane panggunaan pasien, HoverMatt kudu dibusak nganggo solusi pembersih sing digunakake ing rumah sakit kanggo disinfeksi peralatan medis. Solusi bleach 10: 1 (10 bagean banyu: siji bagean bleach) utawa wipes disinfecting uga bisa digunakake. Penting kanggo ngetutake instruksi pabrikan solusi reresik kanggo nggunakake, kalebu wektu manggon lan jenuh.
CATETAN: Reresik nganggo larutan pemutih bisa ngrusak warna kain.
Yen HoverMatt sing bisa digunakake maneh dadi reged banget, kudu dicuci ing mesin cuci kanthi suhu banyu maksimal 160 ° F (71 ° C). Solusi pamutih 10: 1 bisa digunakake (10 bagean banyu: siji bagean pemutih) sajrone siklus ngumbah.
HoverMatt kudu garing hawa yen bisa. Pangatusan udhara bisa dicepetake kanthi nggunakake pasokan udara kanggo ngedhunake hawa ing njero HoverMatt. Yen nggunakake pengering, setelan suhu kudu disetel ing setelan sing paling keren. Suhu pangatusan ngirim ora ngluwihi 115 ° F (46 ° C). Backing saka nilon punika polyurethane lan bakal mulai rusak sawise pangatusan suhu dhuwur bola-bali.
HoverMatt Double-Coated ora kudu dilebokake ing pengering.
Kanggo mbantu supaya HoverMatt tetep resik, HoverTech nyaranake nggunakake HoverCover™ Disposable Absorbent Cover utawa Disposable Sheets. Apa wae sing digoleki pasien supaya amben rumah sakit tetep resik, bisa uga diselehake ing ndhuwur HoverMatt.
HoverMatt Gunakake Pasien Tunggal ora dimaksudake kanggo dicuci.
AIR SUPPLY CLEANING lan Maintenance
Deleng manual pasokan udara kanggo referensi.
CATETAN: Priksa pedoman lokal / negara / federal / internasional sadurunge mbuwang.
PREVENTIVE MAINTENANCE
Sadurunge digunakake, pengawasan visual kudu ditindakake ing HoverMatt kanggo mesthekake yen ora ana karusakan sing katon sing bakal nyebabake HoverMatt ora bisa digunakake. HoverMatt kudu duwe kabeh tali lan gagang pasien (referensi manual kanggo kabeh bagean sing cocog). Ora ana luh utawa bolongan sing bakal nyegah HoverMatt saka inflating. Yen karusakan apa wae ditemokake sing bakal nyebabake sistem ora bisa digunakake kaya sing dikarepake, HoverMatt kudu dicopot saka panggunaan lan bali menyang HoverTech kanggo ndandani (Single-Patient Use Hover Matts kudu dibuwang).
KONTROL INFEKSI
HoverTech nawakake kontrol infeksi sing unggul karo HoverMatt sing bisa digunakake maneh kanthi tutup panas. Konstruksi unik iki ngilangi bolongan jarum saka kasur sing dijahit sing bisa dadi cara mlebu bakteri. Kajaba iku, HoverMatt sing dilapisi panas, Double-Coated HoverMatt nawakake permukaan anti noda lan cairan supaya gampang diresiki. The Single-Patient Use HoverMatt uga kasedhiya kanggo ngilangi kamungkinan kontaminasi salib lan perlu kanggo laundering.
Yen HoverMatt digunakake kanggo pasien isolasi, rumah sakit kudu nggunakake protokol / prosedur sing padha kanggo kasur lan / utawa linen ing kamar pasien kasebut.
Nalika produk tekan pungkasan umure, kudu dipisahake miturut jinis materi supaya bagean kasebut bisa didaur ulang utawa dibuwang kanthi bener miturut syarat lokal.
Transportasi lan Panyimpenan
Produk iki ora mbutuhake kahanan panyimpenan khusus.
Wangsul lan ndandani
Kabeh produk sing bali menyang HoverTech kudu duwe nomer Returned Goods Authorization (RGA) sing diterbitake dening perusahaan.
Mangga nelpon 800-471-2776 lan njaluk anggota Tim RGA sing bakal ngetokake sampeyan nomer RGA. Produk apa wae sing bali tanpa nomer RGA bakal nyebabake wektu tundha ing wektu ndandani.
Produk sing bali kudu dikirim menyang:
HoverTech
Attn: RGA # ___________
4482 Cara Inovasi
Allentown, PA 18109
Kanggo garansi produk, bukak websitus: https://hovermatt.com/standard-product-warranty/
Kanggo perusahaan Eropa, kirim produk bali menyang:
Attn: RGA #____________
Menara Ilmu Kista
SE-164 51 Kista, Swedia
HoverTech
4482 Cara Inovasi
Allentown, PA 18109
www.HoverMatt.com
Info@HoverMatt.com
Produk kasebut tundhuk karo standar sing ditrapake kanggo produk Kelas 1 ing Peraturan Piranti Medis (EU) 2017/745 babagan piranti medis.
CEpartner4U, ESDOORNLAAN 13,
3951DB MAARN, WILAYAH.
Etac Ltd.
Unit 60, Hartlebury Trading Estate,
Hartlebury, Kidderminster,
Worcestershire, DY10 4JB
+44 121 561 2222
www.etac.com/uk
TapMed Swiss AG
Gumprechtstrasse 33
CH-6376 Emmetten
CHRN-AR-20003070
Yen ana kedadeyan ala sing ana gandhengane karo piranti kasebut, kedadeyan kasebut kudu dilaporake menyang wakil resmi kita. Wakil resmi kita bakal ngirim informasi menyang pabrikan.
Dhukungan Pelanggan
4482 Inovasi Way Allentown, PA 18109 800.471.2776
Fax 610.694.9601
www.HoverMatt.com
Info@HoverMatt.com
Dokumen / Sumber Daya
![]() |
HOVERTECH HoverMatt SPU Setengah Matt [pdf] Manual pangguna HoverMatt SPU Setengah Matt, HoverMatt, SPU Setengah Matt, Setengah Matt, Matt |