logo ASSURED ASSURED ACCESS LPCI-COM Series Low Profile PCI Multi Port Serial Komunikasi Cards - logo ASSURED ACCESS LPCI-COM Series Low Profile PCI Multi Port Serial Komunikasi Cards

MODEL LPCI-COM-8SM
LPCI-COM-4SM
LPCI-COM232-8
LPCI-COM232-4
Low Profile PCI Multi-Port Serial
Kartu Komunikasi
MANUAL PENGGUNA
10623 Roselle Street, San Diego, CA 92121 
858-550-9559 • FAX 858-550-7322
contactus@accesio.comwww.accesio.com
www.assured-systems.com 
sales@assured-systems.com

ACCESS LPCI-COM Series Low Profile PCI Multi Port Serial Komunikasi Cards

Kabar
Informasi ing dokumen iki diwenehake mung kanggo referensi. ACCES ora nanggung tanggung jawab sing muncul saka aplikasi utawa panggunaan informasi utawa produk sing diterangake ing kene. Dokumen iki bisa ngemot utawa ngrujuk informasi lan produk sing dilindhungi hak cipta utawa paten lan ora menehi lisensi miturut hak paten ACCES, utawa hak wong liya.
IBM PC, PC/XT, lan PC/AT minangka merek dagang kadhaptar saka International Business Machines Corporation.
Dicithak ing AS. Hak cipta 2004, 2005 dening ACCES I / O Products Inc, 10623 Roselle Street, San Diego, CA 92121. Kabeh hak dilindhungi undhang-undhang.
WARNING!!
Tansah nyambung lan pedhot kabel lapangan karo daya komputer mati. Tansah mateni daya komputer sadurunge masang kertu. Nyambung lan medhot KABEL, UTAWA NGINSTAL KARTU menyang SISTEM KARYA KOMPUTER UTAWA FIELD POWER ON bisa nimbulaké karusakan kanggo kertu I / O lan bakal roso sepi ALL JAMINAN, diwenehake UTAWA.
Garansi
Sadurunge dikirim, peralatan ACCES dipriksa kanthi tliti lan diuji miturut spesifikasi sing ditrapake. Nanging, yen peralatan gagal, ACCES njamin para pelanggan manawa layanan lan dhukungan cepet bakal kasedhiya. Kabeh peralatan sing asline diprodhuksi dening ACCES sing ditemokake cacat bakal didandani utawa diganti miturut pertimbangan ing ngisor iki.
Sarat lan Ketentuan
Yen unit dicurigai gagal, hubungi departemen Layanan Pelanggan ACCES. Disiapake kanggo menehi nomer model unit, nomer seri, lan gambaran saka gejala gagal. Kita bisa uga menehi saran sawetara tes prasaja kanggo konfirmasi kegagalan. Kita bakal nemtokake nomer Return Material Authorization (RMA) sing kudu katon ing label njaba paket bali. Kabeh Unit / komponen kudu mlaku dikempalken kanggo nangani lan bali karo barang prabayar menyang ACCES ditetepake Service Center, lan bakal bali menyang customer / situs pangguna barang prabayar lan invoice.
Cakupan
Telung Taun Kapisan: Unit / bagean sing bali bakal didandani lan / utawa diganti ing pilihan ACCES tanpa biaya kanggo tenaga kerja utawa bagean sing ora dikecualekake kanthi garansi. Garansi diwiwiti kanthi pangiriman peralatan.
Taun-taun Sawise: Saklawase umur peralatan sampeyan, ACCES siyap nyedhiyakake layanan ing situs utawa ing pabrik kanthi tarif sing cukup padha karo manufaktur liyane ing industri kasebut.
Peralatan Ora Diprodhuksi dening ACCES
Peralatan sing disedhiyakake nanging ora diprodhuksi dening ACCES dijamin lan bakal didandani miturut syarat lan kahanan garansi pabrikan peralatan kasebut.
Umum
Ing Garansi iki, tanggung jawab ACCES diwatesi kanggo ngganti, ndandani utawa nerbitake kredit (miturut kawicaksanan ACCES) kanggo produk apa wae sing kabukten rusak sajrone periode garansi. Ing kasus apa ACCES tanggung jawab kanggo karusakan consequential utawa khusus teka saka nggunakake utawa nyalahi panggunaan saka produk kita. Pelanggan tanggung jawab kanggo kabeh biaya sing disebabake dening modifikasi utawa tambahan kanggo peralatan ACCES sing ora disetujoni kanthi nulis dening ACCES utawa, yen miturut pendapat ACCES, peralatan kasebut wis digunakake ora normal. "Panganggone ora normal" kanggo tujuan babar pisan iki ditetepake minangka panggunaan apa wae sing peralatan kasebut kapapar liyane saka panggunaan kasebut utawa dimaksudake minangka bukti saka perwakilan tuku utawa dodolan.
Liyane saka ndhuwur, ora babar pisan liyane, ditulis utawa diwenehake, bakal ditrapake kanggo samubarang lan kabeh peralatan kuwi pepak utawa didol dening ACCES.

Bab 1: Pambuka

Kertu antarmuka serial iki dirancang kanggo transmisi multipoint efektif ing salah siji saka telung mode ing saben saluran. Mode kasebut yaiku protokol RS232, RS422 lan RS485 (EIA485).
Mode RS485 bisa ditindakake kanthi telung cara. Bisa uga dioperasikake minangka saluran kontrol RTS standar, mode "RTS Otomatis (diarani sawetara minangka Auto RS485)" utawa minangka "saluran mode RS4 485 kabel.
Kertu punika 6.60 inci dawa lan bisa diinstal ing 3.3 utawa 5-volt slot PCI-bus saka IBM PC utawa komputer kompatibel. Kertu kasebut nduweni wolung port serial asynchronous, jinis 16788 buffered UART.
Seri kertu iki kasedhiya ing mung versi 4-port lan RS-232.
Fitur

  • Wolung utawa papat port RS-232/422/485 komunikasi serial
  • Kinerja dhuwur 16788 kelas UART kanthi 64-bait FIFO kanggo saben TX lan RX
  • Ndhukung kecepatan komunikasi data nganti 921.6kbps
  • Piranti lunak sing kompatibel karo kabeh sistem operasi
  • 6 'kabel breakout mungkasi karo konektor DB9M standar industri

Aplikasi

  • Sistem POS (Point-of-sale).
    • Mesin Gaming
    • Stasiun Transportasi
    • Telekomunikasi
    • Otomasi Industri
    • Sistem ATM (Mesin Teller Otomatis).
    • Multiple kontrol terminal
    • Otomatisasi Kantor
    • Kios

Deskripsi Fungsional
Operasi Mode Balance RS422
Kertu kasebut ndhukung komunikasi RS422 lan nggunakake driver imbang diferensial kanggo kakebalan jarak jauh lan gangguan. Kertu kasebut uga nduweni kemampuan kanggo nambah resistor beban kanggo mungkasi jalur komunikasi. Komunikasi RS422 mbutuhake pemancar nyedhiyakake vol biastage kanggo mesthekake negara "nol" dikenal. Uga, input panrima ing saben pungkasan jaringan kudu diakhiri kanggo ngilangi "dering". Kertu ndhukung biasing minangka standar lan ndhukung mandap dening jumper ing kertu. Yen aplikasi sampeyan mbutuhake pemancar ora bias, hubungi pabrik.
Operasi Mode Balance RS485
Kertu kasebut ndhukung komunikasi RS485 lan nggunakake driver imbang diferensial kanggo kakebalan jarak jauh lan gangguan. Operasi RS485 kalebu transceiver switchable lan kemampuan kanggo ndhukung macem-macem piranti ing "baris partai" siji. Spesifikasi RS485 nemtokake maksimal 32 piranti ing siji baris. Jumlah piranti sing dilayani ing baris siji bisa ditambahi kanthi nggunakake "repeater".
Kertu kasebut uga nduweni kemampuan kanggo nambah resistor beban kanggo mungkasi jalur komunikasi. Komunikasi RS485 mbutuhake siji pemancar nyedhiyakake vol biastage kanggo mesthekake negara "nol" dikenal nalika kabeh pemancar mati. Uga, input panrima ing saben pungkasan jaringan kudu diakhiri kanggo ngilangi "dering". Kertu ndhukung biasing minangka standar lan ndhukung mandap dening jumper ing kertu. Yen aplikasi sampeyan mbutuhake pemancar ora bias, hubungi pabrik.
Kompatibilitas Port COM
Wolung UART kompatibel Tipe 16550 sing digabungake ing UART oktal tunggal digunakake minangka Elemen Komunikasi Asynchronous (ACE). Iki kalebu 64-bait ngirim & nampa buffer kanggo nglindhungi data ilang ing sistem operasi mbukak akeh tugas, nalika njaga 100 persen kompatibilitas karo port serial IBM asli. Sistem menehi alamat (es).
A osilator kristal dumunung ing kertu. Osilator iki ngidini pilihan baud rate sing tepat nganti 115,200 utawa, kanthi ngganti jumper, nganti 921,600 kanthi osilator kristal standar.
Pembalap / panrima sing digunakake, SP841 ing mode non-RS232, bisa nyopir garis komunikasi sing dawa banget kanthi tingkat baud sing dhuwur. Bisa drive nganti +60 mA ing garis imbang lan nampa input minangka kurang 200 mV sinyal diferensial superimposed ing swara mode umum +12 V utawa -7 V. Ing cilik saka konflik komunikasi, driver / panrima fitur mati termal.
Pembalap / panrima sing digunakake ing mode RS232 yaiku ICL3245 kanthi kacepetan dhuwur.
Mode Komunikasi
Kertu kasebut ndhukung komunikasi Half-Duplex kanthi sambungan kabel 2-kabel. Half-Duplex ngidini lalu lintas kanggo lelungan ing loro arah, nanging mung siji cara ing wektu. Komunikasi RS485 umume nggunakake mode Half-Duplex amarga mung nuduhake sepasang kabel.
Baud Rate Ranges
Kertu nduweni kemampuan kanggo rong kisaran tingkat baud lan sampeyan bisa milih sing pengin digunakake kanggo kabeh port ing kertu. Siji kisaran nganti 115,200 baud lan liyane nganti 921,600 baud.
Cathetan: Waca Tabel 5-1: Nilai Baud Rate Divisor ing bab 5 manual iki.
Kontrol Transceiver Auto-RTS
Ing komunikasi RS485, driver kudu diaktifake lan dipateni yen perlu, ngidini kabeh kertu kanggo nuduhake kabel loro kabel. Kertu ngontrol driver kanthi otomatis. Kanthi kontrol otomatis, driver diaktifake nalika data siap dikirim.
Kanthi kertu iki, driver tetep aktif kanggo wektu sing bisa diatur. Bisa uga dipatèni ing completion saka transmisi karakter (standar), utawa bisa disetel kanggo ngenteni nganti siji wektu transmisi karakter tambahan sawise transfer data rampung lan banjur dipatèni.
Mulane, panrima biasane diaktifake, banjur dipateni sajrone transmisi RS485, banjur diaktifake maneh sawise transmisi rampung (bisa diatur saka nol nganti plus siji wektu transmisi karakter). Kertu kanthi otomatis nyetel wektu kanggo baud rate data. (CATATAN: Thanks kanggo fitur kontrol otomatis, kertu kasebut cocog kanggo digunakake ing aplikasi Windows) ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - Diagram BlokPanduan Order

  • LPCI-COM-8SM Low Profile Kertu RS-232/422/485 PCI wolung port kanthi braket pemasangan dhuwur standar lan kabel DB6M 9'
  • LPCI-COM232-8 Low Profile Kertu RS-232 PCI wolung port kanthi braket pemasangan dhuwur standar lan kabel breakout 6'DB9M
  • LPCI-COM-8SM Low Profile Kertu RS-232/422/485 PCI papat port kanthi braket pemasangan dhuwur standar lan kabel DB6M 9'
  • LPCI-COM232-4 Low Profile Kertu RS-232 papat port PCI kanthi braket pemasangan dhuwur standar lan kabel breakout 6'DB9M

Pilihan Model

  • -L Low-profile mounting krenjang
  • - RoHS RoHS tundhuk versi

Aksesoris Pilihan

 BRKT-551-SCB  Nguatake braket (kanggo digunakake karo standar dhuwur braket PCI mung) ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - Aksesoris 1
 ADAP9  Adaptor terminal meneng DB9F kanggo 9 terminal meneng ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - Aksesoris 2
 ADAP9-2  Adaptor terminal meneng karo loro konektor DB9F lan 18 terminal meneng ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - Aksesoris 3

Pesenan Khusus
Tarif baud Custom kasedhiya ing panyuwunan. Hubungi pabrik kanthi syarat sing tepat. Spesial liyane: lapisan conformal, piranti lunak khusus, konektivitas RJ-45, kothak breakout khusus, lan sapiturute, kita bakal nggarap sampeyan kanggo nyedhiyakake apa sing dibutuhake. Klebu karo papan sampeyan
Komponen ing ngisor iki kalebu ing kiriman sampeyan, gumantung saka pilihan sing dipesen. Mangga njupuk wektu saiki kanggo mesthekake yen ora ana barang sing rusak utawa ilang.

  • Kertu wolung utawa papat port kanthi krenjang pemasangan dhuwur standar
  • 6 'kabel breakout kanggo konektor DB9M
  • Software Master CD
  • Pandhuan Wiwitan Cepet

Bab 2: Instalasi

Pandhuan Miwiti Cepet (QSG) sing dicithak wis dikempalken karo kertu kanggo penak. Yen sampeyan wis nindakake langkah-langkah saka QSG, sampeyan bisa nemokake bab iki keluwih lan bisa nerusake kanggo miwiti ngembangake aplikasi sampeyan.
Piranti lunak sing kasedhiya karo kertu iki ana ing CD lan kudu diinstal ing hard disk sadurunge digunakake. Kanggo nindakake iki, tindakake langkah-langkah ing ngisor iki sing cocog kanggo sistem operasi sampeyan.
Ngatur Pilihan Card liwat Pilihan Jumper
Sadurunge masang kertu menyang komputer, waca kanthi teliti Bab 3: Pilihan Pilihan saka manual iki, banjur atur kertu miturut syarat lan protokol (RS-232, RS-422, RS-485, 4-kabel 485, lsp.) . Program persiyapan basis Windows kita bisa digunakake bebarengan karo Bab 3 kanggo ngewangi konfigurasi jumper ing kertu, uga menehi katrangan tambahan babagan panggunaan macem-macem opsi kertu (kayata mandap, bias, rentang baud rate, RS-232, RS422, RS-485, lsp).
Instalasi Piranti Lunak CD
Pandhuan ing ngisor iki nganggep drive CD-ROM minangka drive "D". Ganti huruf drive sing cocog kanggo sistem sampeyan yen perlu.
DOS

  1.  Selehake CD menyang drive CD-ROM.
  2. JinisASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - lambang 1 kanggo ngganti drive aktif menyang drive CD-ROM.
  3. Jinis ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - lambang 2kanggo mbukak program instalasi.
  4. Tindakake pituduh ing layar kanggo nginstal piranti lunak kanggo papan iki.

WINDOWS

  1. Selehake CD menyang drive CD-ROM.
  2. Sistem kudu mbukak program instalasi kanthi otomatis. Yen program instal ora mlaku kanthi cepet, klik START | RUN lan ketik ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - lambang 3, klik OK utawa pencet ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - lambang 4.
  3. Tindakake pituduh ing layar kanggo nginstal piranti lunak kanggo papan iki.

LINUX

  1. Mangga deleng linux.htm ing CD-ROM kanggo informasi babagan nginstal ing linux.

Cathetan: Papan COM bisa diinstal ing meh kabeh sistem operasi. Kita ndhukung instalasi ing Windows versi sadurungé, lan kamungkinan banget ndhukung versi mangsa uga.
Ati-ati! * ESD
Discharge statis siji bisa ngrusak kertu lan nyebabake gagal prematur! Tututi kabeh pancegahan sing cukup kanggo nyegah metune statis kayata grounding dhewe kanthi ndemek lumahing lemah sadurunge ndemek kertu.
Instalasi Hardware

  1. Priksa manawa sampeyan nyetel switch lan jumper saka bagean Pilihan Pilihan ing manual iki utawa saka saran SETUP.EXE.
  2. Aja nginstal kertu menyang komputer nganti piranti lunak wis diinstal kanthi lengkap.
  3. Pateni daya komputer LAN copot daya AC saka sistem.
  4. Copot tutup komputer.
  5. Kasebut kanthi teliti, nginstal kertu ing kasedhiya 5V utawa 3.3V slot expansion PCI (sampeyan bisa uga kudu mbusak backplate pisanan).
  6. Priksa manawa kertu pas lan kencengake sekrup. Priksa manawa krenjang kertu soyo tambah wis bener ngaco menyang Panggonan lan ana lemah sasis positif.
  7. Pasang kabel I/O menyang konektor sing dipasang ing braket kertu.
  8. Ganti tutup komputer lan uripake komputer. Ketik program persiyapan CMOS sistem sampeyan lan verifikasi manawa pilihan plug-and-play PCI disetel kanthi tepat kanggo sistem sampeyan. Sistem sing nganggo Windows 95/98/2000/XP/2003 (utawa sistem operasi sing cocog karo PNP liyane) kudu nyetel pilihan CMOS menyang OS. Sistem sing mlaku ing DOS, Windows NT, Windows 3.1, utawa sistem operasi liyane sing ora cocog karo PNP kudu nyetel pilihan PNP CMOS menyang BIOS utawa Motherboard. Simpen pilihan lan terus booting sistem.
  9. Umume komputer kudu ndeteksi kertu kanthi otomatis (gumantung saka sistem operasi) lan kanthi otomatis rampung nginstal driver.
  10. Mbukak PCIfind.exe kanggo ngrampungake nginstall kertu menyang pendaptaran (mung Windows) lan kanggo nemtokake sumber daya diutus.
  11. Mbukak siji saka kasedhiya sample program sing disalin menyang direktori kertu mentas digawe (saka CD) kanggo nyoba lan ngesyahke instalasi.

Alamat dhasar sing diwenehake dening BIOS utawa sistem operasi bisa diganti saben hardware anyar diinstal utawa dibusak saka komputer. Mangga dipriksa maneh PCIFind utawa Manager Piranti yen konfigurasi hardware diganti. Piranti lunak sing sampeyan tulis bisa kanthi otomatis nemtokake alamat dhasar kertu nggunakake macem-macem cara gumantung saka sistem operasi. Ing DOS, direktori PCI\SOURCE nuduhake panggilan BIOS sing digunakake kanggo nemtokake alamat lan IRQ sing ditugasake kanggo piranti PCI sing diinstal. Ing Windows, Windows sampprogram le nduduhake querying entri pendaptaran (digawe dening PCIFind lan NTIOPCI.SYS sak boot-up) kanggo nemtokake informasi iki padha.

Bab 3: Pilihan Pilihan

Kanggo mbantu sampeyan nemokake jumper sing diterangake ing bagean iki, deleng Peta Pilihan Pilihan ing pungkasan bagean iki. Operasi bagean komunikasi serial ditemtokake dening instalasi jumper minangka diterangake ing paragraf ing ngisor iki.
Kanggo penak saka pangguna, instruksi kanggo panggonan seko jumper uga sutra layar ing mburi kertu.
Terminasi
Saluran transmisi kudu diakhiri ing mburi panampa kanthi impedansi karakteristik.
Nginstal jumper ing lokasi kanthi label LDxO ngetrapake beban 120Ω ing transmisi / nampa input / output kanggo operasi RS485.
Jumpers gadhah apa karo mandap saben saluran dumunung cedhak konektor output. Dheweke diwenehi label kanthi saluran. Jumper beban diberi label "LD". Loro jumper liyane digunakake kanggo nyambungake ngirim lan nampa baris kanggo loro kabel mode RS485.ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - Skema Terminasi Sederhana

Ing operasi RS485 ing ngendi ana pirang-pirang terminal, mung port RS485 ing saben ujung jaringan kudu duwe impedansi terminating kaya sing kasebut ing ndhuwur. Kanggo mungkasi port COM A, nyelehake jumper ing lokasi kanthi label Ch A -LD. Kanggo mungkasi port COM B, COM C, COM D, COM E, COM F lan COM H, nyelehake jumper ing lokasi kanthi label Ch B - LD, Ch C - LD, Ch D - LD, Ch E - LD, Ch F - LD, Ch G - LD lan Ch H - LD mungguh.
Uga, kanggo operasi RS485, kudu ana bias ing garis TRX + lan TRX-. Yen kertu ora nyedhiyakake bias kasebut, hubungi dhukungan teknis pabrik.
Kabel Data Kab
Sambungan Pin Sinyal RS-485

Ain / metu + 2
Ain / metu- 3
100 Ω menyang Ground 5

Baud Rate Ranges
Jumper kanthi label CLK X8 nyedhiyakake sarana kanggo milih tarif baud ing sawetara sing luwih dhuwur. Nalika jumper ora diselehake ing metu posisi CLK X8, sawetara baud rate nganti 115,200 baud. Nalika ing posisi CLK X8, sawetara baud rate nganti 921,600 baud.
Ganggu
Wigati dimangerteni manawa, ing WindowsNT, owah-owahan kudu ditindakake ing registri sistem kanggo ndhukung enggo bareng IRQ. Ing ngisor iki dijupuk saka "Controlling Multiport Serial I/O Cards" sing diwenehake dening Microsoft ing perpustakaan MSDN,  documentid: mk:@ivt:nt40res/D15/S55FC.HTM, uga kasedhiya ing WindowsNT Resource Kit.
Pembalap serial Microsoft bisa digunakake kanggo ngontrol akeh kertu serial multiport bisu. Bisu nuduhake yen kontrol ora kalebu prosesor ing papan. Saben port kertu multiport nduweni subkunci sing kapisah ing subkunci HKLM\CurrentControlSet\Services\Serial ing registri. Ing saben subkunci iki, sampeyan kudu nambahake nilai kanggo DosDevices, Interrupt, InterruptStatus, PortAddress, lan PortIndex amarga iki ora dideteksi dening Hardware Recognizer. (Kanggo katrangan lan kisaran kanggo nilai kasebut, deleng Regentry.hlp, bantuan Registry file ing CD WindowsNT Workstation Resource Kit.)
Kanggo exampNanging, yen sampeyan duwe kertu wolung port sing dikonfigurasi kanggo nggunakake alamat 0xFC00 kanthi interupsi 05, nilai ing Registry yaiku:

Subkunci Seri 2:
PortAddress = REG_DWORD 0xFC00
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM3
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 1
Indexed = REG_DWORD 0
Subkunci Seri 6:
PortAddress = REG_DWORD 0xFC20
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM7
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 5
Indexed = REG_DWORD 0
Subkunci Seri 3:
PortAddress = REG_DWORD 0xFC08
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM4
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 2
Indexed = REG_DWORD 0
Subkunci Seri 7:
PortAddress = REG_DWORD 0xFC28
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM8
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 6
Indexed = REG_DWORD 0
Subkunci Seri 4:
PortAddress = REG_DWORD 0xFC10
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM5
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 3
Indexed = REG_DWORD 0
Subkunci Seri 8:
PortAddress = REG_DWORD 0xFC30
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM9
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 7
Indexed = REG_DWORD 0
Subkunci Seri 5:
PortAddress = REG_DWORD 0xFC18
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM6
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 4
Indexed = REG_DWORD 0
Subkunci Seri 9:
PortAddress = REG_DWORD 0xFC38
Interrupt = REG_DWORD 5
DosDevices = REG_SZ COM10
InterruptStatus = REG_DWORD 0xFC40
PortIndex = REG_DWORD 8
Indexed = REG_DWORD 0

Tabel 3-1: Nilai Registry WindowsNTASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - Peta Pilihan PilihanKertu wis 8 saluran kapisah sing bisa diatur individu. Saben saluran bisa digunakake ing:

  1. RS485 (mode 2 kabel) - Mode iki bisa nggunakake "RTS Otomatis"
  2. RS422
  3. RS232
  4. RS485 (4 kabel mode)\

Jumper ing kertu kudu diselehake kanthi bener supaya bisa nindakake fungsi kertu kanthi bener.
Kanggo milih mode dhasar kanggo saluran, jumper M1 lan M2 kudu diselehake kanthi bener. (Iki jumpers dumunung ing mburi kertu adoh saka konektor kabel).

Mode M1 M2
RS485 (2 Wire Mode) IN OUT
RS485 (4 Wire Mode) OUT IN
RS422 IN IN
RS232 OUT OUT

Jumper liyane

  1. RS 485 (2 mode kabel) - Loro jumper kudu diinstal kanggo saben saluran ing mode iki kanggo nyambungake garis output lan input. Jumper iki dumunung ing cedhak konektor kabel lan diwenehi label karo huruf saluran lan "485."
  2. RS 485 (2 mode kabel) nggunakake "Auto RTS" - Siji jumper kudu diinstal kanggo saben saluran ing mode iki. Jumper iki dumunung ing mburi kertu adoh saka konektor kabel, jejer kanggo "M" jumper lan label karo huruf saluran lan "A8".
  3. RS 485 utawa RS 422 Muatan - Siji jumper kudu dipasang kanggo saben saluran sing mbutuhake beban. Jumper iki dumunung ing ujung konektor kabel kertu lan diwenehi label karo huruf saluran lan "LD."

Cathetan:

  1. Sembarang jumper sing ora dibutuhake sing diinstal bisa nyebabake kertu ora bisa digunakake.
  2. Yen jumper "Auto RTS" diganti, kertu kudu reboot utawa ngreset. Iki dibutuhake amarga status jumper diwaca nalika kertu direset lan digunakake kanggo program fungsi Auto RTS menyang saluran cocok (e) UART. Yen negara jumper iki diganti, UART ora bakal diprogram kanthi bener nganti jumper wis diwaca maneh. Kanggo nindakake iki, kertu kudu direset.

Bab 4: Pamilihan Alamat

Kertu nggunakake siji spasi alamat. COM A, COM B, COM C, COM D, COM E, COM F, COM G lan COM H masing-masing manggoni wolung lokasi registrasi berturut-turut. Register interrupt sing nuduhake port utawa port sing nyebabake interupsi dumunung ing alamat dhasar + 64.
Arsitektur PCI yaiku Plug-and-Play. Iki tegese BIOS utawa Operating System nemtokake sumber daya diutus kanggo kertu PCI tinimbang sampeyan milih sumber daya karo ngalih utawa jumper. Akibaté, sampeyan ora bisa nyetel utawa ngganti alamat dhasar kertu. Sampeyan mung bisa nemtokake apa sistem wis diutus.
Kanggo nemtokake alamat dhasar sing wis diutus, mbukak PCIFind.EXE program sarana kasedhiya. Utilitas iki bakal nampilake dhaptar kabeh kertu sing dideteksi ing bus PCI, alamat sing ditugasake kanggo saben fungsi ing saben kertu, lan IRQ (yen ana) sing diwenehake.
Utawa, sawetara sistem operasi (Windows 95/98/2000/XP) bisa ditakoni kanggo nemtokake sumber daya sing ditugasake. Ing sistem operasi iki, sampeyan bisa nggunakake sarana Pangatur Piranti saka System Applet ing panel kontrol. Kertu kasebut diinstal ing kelas Akuisisi Data saka dhaptar Manager Piranti. Milih kertu, ngeklik Properties, banjur milih Tab Resources bakal nampilake dhaptar sumber daya sing diparengake menyang kertu.
Bus PCI ndhukung 64K ruang I / O. Alamat kertu sampeyan bisa uga ana ing ngendi wae ing kisaran hex 0000 nganti FFFF.
PCIFind nggunakake ID Vendor lan ID Piranti kanggo nggoleki kertu, banjur maca alamat dhasar lan IRQ.
Yen sampeyan pengin nemtokake alamat dhasar lan IRQ dhewe, gunakake informasi ing ngisor iki.
ID Vendor kanggo kertu kasebut yaiku 494F. (ASCII kanggo "IO")
ID Piranti kanggo kertu yaiku 10E8h.

Bab 5: Pemrograman

Sampl Program
Ana sampprogram le kasedhiya karo kertu ing C, Pascal, QuickBASIC, lan sawetara basa Windows. DOS samples dumunung ing direktori DOS lan Windows samples dumunung ing direktori WIN32.
Pemrograman Windows 
Kertu kasebut dipasang ing Windows minangka port COM. Mangkono fungsi API standar Windows bisa digunakake. utamané:
► GaweFile() lan CloseHandle () kanggo mbukak lan nutup port.
►SetupComm(), SetCommTimeouts(), GetCommState(), lan SetCommState() kanggo nyetel lan ngganti setelan port.
► WacaFile() lan TulisFile() kanggo ngakses port.
Deleng dokumentasi kanggo basa sing dipilih kanggo rincian.
Ing DOS, proses kasebut identik karo program UART sing kompatibel karo 16550 utawa 16750.
Peta Alamat
Inti saka fungsi UART diwenehake dening chip EXAR XR16L788.
chip iki 16550 lan 16750 kompatibel, nanging nduweni fitur ekstra sing mbutuhake sesambungan karo tambahan 8 ndhaftar saben saluran. Contone, perlu kanggo nyetel fungsi "Auto RTS". (EXAR nuduhake fungsi iki minangka "Auto RS485" ing literatur). Nulis dibutuhake kanggo UART rampung kanthi otomatis nalika kertu rebooted.
Kanggo nggunakake piranti lunak standar sing mung komunikasi karo 8 ndhaptar pisanan saben saluran, alamat dipetakan maneh ing kertu kasebut.
8 UARTS manggoni 64 alamat pisanan.
Register status interupsi dumunung ing basis + 40h.
Tarif Baud
Ing kertu, frekuensi jam UART yaiku 1.8432 MHz. Ing ngisor iki minangka tabel frekuensi pembagi populer.

Baud Rate Pembagi x1 Pembagi x8 Maks Bedane. Panjang Kabel*
921600 1 250 ft
460800 2 550 ft
230400 4 1400 ft
153600 6 2500 ft
115200 1 8 3000 ft
57600 2 16 4000 ft
38400 3 24 4000 ft
28800 4 32 4000 ft
19200 6 48 4000 ft
14400 8 64 4000 ft
9600 12 96 - Paling Umum 4000 ft
4800 24 192 4000 ft
2400 48 384 4000 ft
1200 96 768 4000 ft

* Iki minangka maksimum teoritis adhedhasar kahanan khas lan kabel kualitas apik, adhedhasar standar EIA 485 lan EIA 422 kanggo pembalap diferensial sing seimbang. Dawane kabel maksimum sing diidini kanggo komunikasi RS-232 yaiku 50 kaki amarga sinyal driver baris siji-rampung.
Tabel 5-1: Nilai Baud Rate Divisor

Bab 6: Tugas Pin Konektor

Sambungan Input / Output
kertu Komunikasi Serial kertu nggunakake wolung konektor 9-pin individu, kasedhiya liwat kabel spider saka 68-pin HVDCI D-konektor.
Kanggo mesthekake yen ana kerentanan minimal kanggo EMI lan radiation minimal, iku penting sing kertu soyo tambah krenjang bener ngaco menyang Panggonan lan ana lemah sasis positif. Uga, teknik kabel EMI sing tepat (kabel disambungake menyang lemah sasis ing aperture, kabel pasangan bengkong sing dilindhungi, lsp) digunakake kanggo kabel input / output.

DB-9 Male Pin kanggo saben Ch AG RS-232 Sinyal (Industri Standar) RS-485 Sinyal (2 kawat) RS-422 Sinyal (Uga 4 kabel RS485)
Ch x – 1 DCD RX-/TX- 1 RX-
Ch x – 2 RX TX + / RX + 1 TX+
Ch x – 3 TX TX- / RX- 1 TX-
Ch x – 4 DTR
Ch x – 5 Gnd Gnd Gnd
Ch x – 6 DSR
Ch x – 7 RTS
Ch x – 8 CTS
Ch x – 9 RI RX+/TX+ 1 RX+

1 Tabel 6-1: Tugas Pin Konektor
RS485 (2 kabel) mbutuhake instalasi jumper ing kertu kanggo nyambungake pin kasebut kanthi bener.
Nalika nggunakake kabel spider, konektor DB 9 sing cocog bakal duwe pin 1 disambungake menyang pin 3 lan pin 2 disambungake menyang pin 9.

Bab 7: Spesifikasi

Antarmuka Komunikasi
• Sambungan I/O: 68 Pin HVDCI SCSI gaya -Konektor
• Port Serial: Kabel breakout wolung sikil diakhiri karo konektor IBM AT standar D-sub 9-pin lanang sing dilindhungi sing kompatibel karo spesifikasi RS485
• Dawane karakter: 5, 6, 7, utawa 8 bit.
• Paritas: Malah, Malah, aneh utawa
• Interval Stop: 1, 1.5 utawa 2 bit.
• Tarif Data Serial: Nganti 115,200 baud, Asynchronous, A sawetara luwih cepet saka tarif, nganti 921,600, ngrambah dening pilihan jumper ing kertu. Tipe 16788 buffered UART.
Pembalap RS-232 sing digunakake ditemtokake minangka bisa 1Mbps. Tingkat baud paling dhuwur sing bisa ditindakake kanthi nggunakake osilator lan pembagi standar yaiku 921.6kbps.
• Alamat: Terus-terusan mappable ing 0000 kanggo FFFF (hex) sawetara alamat bus PCI.
• Sensitivitas Input Panrima: +200 mV, input diferensial.
• Penolakan Mode Umum: + 12V kanggo -7V
• Kapabilitas Drive Output Transmitter: 60 mA, kanthi mateni termal.
lingkungan
• Suhu Operasi: 0 °C. iki +60 °C.
• Suhu panyimpenan: -50 °C. nganti +120 °C.
• asor: 5% nganti 95%, non-kondensasi.
• Daya sing dibutuhake: + 5VDC ing 125 mA konsumsi daya total khas.
• Ukuran: Dawane 6.6 inci (167.6 mm) kanthi dhuwur 2.2 inci (55.8 mm).

Cathetan
UART sing kompatibel karo 16750 nggunakake buffer 64-byte first-in-first-out sing diprogram liwat printah sing dikirim menyang register kontrol FIFO.

Lampiran A: Pertimbangan Aplikasi

Pambuka
Nggarap piranti RS422 lan RS485 ora beda karo nggarap piranti serial RS232 standar lan loro standar iki bisa ngatasi kekurangan ing standar RS232.
Pisanan, dawa kabel antarane rong piranti RS232 kudu cendhak; kurang saka 50 kaki ing 9600 baud. Kapindho, akeh kesalahan RS232 minangka asil gangguan sing disebabake ing kabel. Standar RS422 ngidini dawa kabel nganti 5000 kaki lan, amarga beroperasi ing mode diferensial, luwih kebal kanggo gangguan sing disebabake.
Sambungan ing antarane rong piranti RS422 (kanthi CTS ora digatekake) kudu kaya ing ngisor iki:

piranti #1 piranti #2
Sinyal Pin No. Sinyal Pin No.
Gnd 5 Gnd 5
TX+ 2 RX+ 9
TX 3 RX 1
RX+ 9 TX+ 2
RX 1 TX 3

Tabel A-1: ​​Sambungan antarane rong piranti RS422
Kekurangan katelu saka RS232 yaiku luwih saka rong piranti ora bisa nuduhake kabel sing padha. Iki uga bener kanggo RS422 nanging RS485 nawakake kabeh keuntungan saka RS422 plus ngidini nganti 32 piranti kanggo nuduhake pasangan bengkong padha. Pangecualian kanggo sing kasebut ing ndhuwur yaiku sawetara piranti RS422 bisa nuduhake kabel siji yen mung siji bakal ngomong lan liyane bakal nampa.
Sinyal diferensial sing seimbang
Alesan manawa piranti RS422 lan RS485 bisa nyopir garis sing luwih dawa kanthi kekebalan gangguan luwih akeh tinimbang piranti RS232 yaiku cara drive diferensial sing seimbang digunakake. Ing sistem diferensial imbang, voltage sing diprodhuksi dening driver katon ing sepasang kabel. A pembalap baris imbang bakal gawé vol diferensialtage saka +2 kanggo +6 volt ing terminal output sawijining. Pembalap baris sing seimbang uga bisa duwe sinyal "aktif" input sing nyambungake driver menyang terminal output. Yen "sinyal ngaktifake OFF, pembalap pedhot saka saluran transmisi. Kawontenan pedhot utawa dipatèni iki biasane diarani minangka kondisi "tristate" lan makili impedansi dhuwur. Pembalap RS485 kudu nduweni kemampuan kontrol iki.
Pembalap RS422 bisa uga duwe kontrol iki nanging ora mesthi dibutuhake.
A panrima baris diferensial imbang ngrasakake voltage negara baris transmisi liwat loro baris input sinyal. Yen input diferensial voltage luwih saka +200 mV, panrima bakal nyedhiyani negara logika tartamtu ing output. Yen diferensial voltage input kurang saka -200 mV, panrima bakal nyedhiyani negara logika ngelawan ing output sawijining. Volume operasi maksimumtage sawetara saka + 6V kanggo -6V ngidini kanggo voltage atenuasi sing bisa dumadi ing kabel transmisi dawa.
Mode umum maksimum voltage rating +7V menehi kakebalan gangguan apik saka voltaginduksi ing garis pasangan bengkong. Sambungan garis lemah sinyal perlu kanggo njaga vol mode umumtage ing kisaran kasebut. Sirkuit kasebut bisa digunakake tanpa sambungan lemah nanging bisa uga ora bisa dipercaya.

Paramèter kahanan Min. Maks.
Output Driver Voltage (dibongkar) 4V 6V
-4V -6V
Output Driver Voltage (dimuat) LD lan LDGND 2V
jumper ing -2V
Resistance Output Driver 50Ω
Driver Output Short-Circuit Saiki +150 mA
Wektu Rise Output Driver 10% interval unit
Sensitivitas panrima +200 mV
Receiver Mode Umum Voltage Range +7V
Resistance Input panrima 4 KΩ

Tabel A-2: Ringkesan Spesifikasi RS422
Kanggo nyegah bayangan sinyal ing kabel lan nambah nolak gangguan ing mode RS422 lan RS485, ujung panrima kabel kudu diakhiri kanthi resistensi sing padha karo impedansi karakteristik kabel. (Istiméwa kanggo iki kasus ngendi baris mimpin dening pembalap RS422 sing tau "tristatated" utawa pedhot saka baris. Ing kasus iki, driver menehi impedansi internal kurang sing terminates baris ing mburi.)
Cathetan
Sampeyan ora kudu nambah resistor terminator kanggo kabel nalika sampeyan nggunakake kertu. Resistor mandap kanggo RX + lan RX- garis kasedhiya ing kertu lan diselehake ing sirkuit nalika sampeyan nginstal Ch X - LD jumpers. (Deleng bagean Pilihan Pilihan ing manual iki.)
Transmisi Data RS485
Standar RS485 ngidini saluran transmisi imbang bisa dienggo bareng ing mode baris partai. Minangka akeh minangka 32 driver / pasangan panrima bisa nuduhake loro-kabel jaringan baris party. Akeh karakteristik saka pembalap lan panrima padha ing RS422 Standard. Siji prabédan yaiku mode umum voltagwatesan e wis lengkap lan + 12V kanggo -7V. Wiwit sembarang driver bisa pedhot (utawa tristated) saka baris, iku kudu tahan iki mode umum voltage sawetara nalika ing kondisi tristate.
Ilustrasi ing ngisor iki nuduhake jaringan garis multidrop utawa partai sing khas. Elinga yen baris transmisi wis mungkasi ing loro ends saka baris nanging ora ing titik drop ing tengah baris.ASSURED ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI - Jaringan Multidrop Two-WireRS485 Four-Wire Multidrop Network
Jaringan RS485 uga bisa disambungake ing mode papat-kabel. Ing jaringan papat kabel, siji simpul kudu dadi simpul master lan kabeh liyane dadi budak. Jaringan kasebut disambungake supaya master komunikasi karo kabeh budak lan kabeh budak mung komunikasi karo master.
Iki wis advantaging peralatan sing nggunakake komunikasi protokol campuran. Amarga simpul budak ora nate ngrungokake tanggapane budak liyane marang master, simpul budak ora bisa mangsuli kanthi salah.

Lampiran B: HVDCI D-Connector Pinout Referensi

Sambungan biasane bakal digawe menyang konektor 9-pin liwat kabel breakout. Yen sampeyan pengin nyambung langsung menyang konektor 68-pin, pin nerjemahake kaya ing ngisor iki.

Pin DB-9 Ch A pin ing 68-pin Ch B Pins ing 68-Pin Ch C Pins ing 68-Pin Ch D Pins ing 68-Pin Ch E Pins ing 68-Pin Ch F Pins ing 68-Pin Ch G Pins ing 68-Pin Ch H Pins ing 68-Pin
1 37 41 45 49 53 57 61 65
2 1 5 9 13 17 21 25 29
3 2 6 10 14 18 22 26 30
4 3 7 11 15 19 23 27 31
5 331 331 331 331 672 672 672 672
6 38 42 46 50 54 58 62 66
7 35 39 43 47 51 55 59 63
8 36 40 44 48 52 56 60 64
9 4 8 12 16 20 24 28 32

Tabel B-1: HVDCI D-Connector Pin Assignments
Pin 34 lan 68 ing 68-pin HVDCI D-Connector nyedhiyakake + 5Volts DC Fused, nanging ora kasedhiya ing konektor DB-9.

  1. Pin 33 ing konektor 68-Pin yaiku Ground, umum kanggo Pin 5 ing saben konektor DB-9 sing ana gandhengane karo Saluran COM A, B, C, lan D.
  2. Pin 67 ing konektor 68-Pin yaiku Ground, umum kanggo Pin 5 ing saben konektor DB-9 sing ana gandhengane karo Saluran COM A, B, C, lan D.

Komentar Pelanggan

Yen sampeyan ngalami masalah karo manual iki utawa mung pengin menehi saran, kirim email menyang: manuals@accesio.com. Mangga rinci babagan kesalahan sing sampeyan temokake lan lebokake alamat surat supaya kita bisa ngirim nganyari manual.

ASSURED ACCESS LPCI-COM Series Low Profile PCI Multi Port Serial Komunikasi Cards - logo10623 Roselle Street, San Diego CA 92121
Telp. (858)550-9559 FAX (858)550-7322
www.accesio.com

Sistem Terjamin
Assured Systems minangka perusahaan teknologi terkemuka kanthi luwih saka 1,500 klien biasa ing 80 negara, nggunakake luwih saka 85,000 sistem menyang basis pelanggan sing beda-beda sajrone 12 taun bisnis. Kita nawakake solusi komputasi, tampilan, jaringan lan koleksi data sing berkualitas tinggi lan inovatif kanggo sektor pasar sing dipasang, industri, lan digital.
US
sales@assured-systems.com
Sales: +1 347 719 4508
Dhukungan: +1 347 719 4508
1309 Coffeen Ave
Ste 1200
Sheridan
WY 82801
USA
EMEA
sales@assured-systems.com
Dodolan: +44 (0)1785 879 050
Dhukungan: +44 (0)1785 879 050
Unit A5 Douglas Park
Taman Bisnis Batu
watu
ST15 0YJ
Inggris
Nomer PPN: 120 9546 28
Nomer Registrasi Bisnis: 07699660

logo ASSURED ASSURED ACCESS LPCI-COM Series Low Profile PCI Multi Port Serial Komunikasi Cards - logowww.assured-systems.com
sales@assured-systems.com

Dokumen / Sumber Daya

ASSURED ACCESS LPCI-COM Series Low Profile PCI Multi Port Serial Komunikasi Cards [pdf] Manual pangguna
LPCI-COM-8SM, LPCI-COM-4SM, LPCI-COM232-8, LPCI-COM232-4, ACCESS LPCI-COM Series Low Profile Kartu Komunikasi Serial Multi Port PCI, Kartu Komunikasi ACCESS, Kartu Komunikasi, Komunikasi, Kartu, Kartu Komunikasi Seri LPCI-COM, Low Profile PCI Multi Port Serial Komunikasi Cards

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *