ZONEMIX4 Zone Controller
“
Specifikimet
- Supports up to 8 controllers per port
- Supports ONE audio input PER accessory port
- Supports up to 8 paging stations per port
- Maximum cable length per port: 100m – 500m depending on
aksesorë
Udhëzimet e përdorimit të produktit
Step 1: Decide Port Wiring Layout
Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.
Step 2: Confirm Limits
Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.
Step 3: Accessory Port Wiring
Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
korrupsionit.
INTERIMET ZONEMIX DHE ZMPS
Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.
WP4R, WP10, WPVOL Wiring & WPBT Wiring
Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.
Udhëzimet e përfundimit
- Terminate the ZONEMIX accessory ports based on which ports you
use using the PORT TERM switches. - Përfundoni aksesorin LAST RS485 në kabllin e portit.
FAQ
Q: How many controllers can be connected per port?
A: The system supports up to 8 controllers per port.
Q: Can multiple wall panels and paging stations be connected on
the same accessory port?
A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.
“`
UDHZUES PIRR RREGULLAT
HYRJE
Portat shtesë ZONEMIX lejojnë lidhjen e paneleve të murit, stacioneve të paging dhe burimeve të hyrjes audio. Ju lutemi ndiqni udhëzuesin më poshtë për të konfiguruar sistemin tuaj.
Çelësi:
ZONEMIX 4
ZONEMIX 8
Wall Controllers Audio Sources
Mbështet deri në 8 kontrollues për port. (shih faqen 2 për detaje)
Mbështet NJË hyrje audio për portë shtesë.
Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.
Ju lutemi vini re se kanalet e hyrjes lokale të audios të portit shtesë janë të kyçura në zonën përkatëse të daljes dhe vetëm një mund të përdoret për çdo zonë. P.sh. hyrja lokale e portit aksesor 1 lidhet me Zonën 1. Megjithatë, panele të shumta muri dhe stacione paging mund të lidhen në të njëjtën portë shtesë.
australianmonitor.com.au
1
HAPI 1: VENDOSI PARAQITJEN E TELIRAVE TË PORTIT
Do you need local audio inputs?
po
Nr
Përdorni një portë shtesë për çdo zonë. p.sh. Porta 1 në Zonën 1, Porta 2 në Zonën 2 etj. Si hyrje audio kërkojnë funksionimin e tyre në shtëpi.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s
HAPI 2: KONFIMONI QË NUK TE tejkaloni KUFIJET E MËPOSHTME
Maximum cable length per port Accessories per port Maximum Accessories in system
100 m
8
130 m
7
180 m
6
24
250 m
5
400 m
4
500 m
3
The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.
australianmonitor.com.au
2
HAPI 3: LIDHJA E PORTIT AKSESOR
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8
Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ZONEMIX
Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –
ZMPS
ZINXHIRI ZMPS DAISY
ZONEMIX
Use an RJ45 splitter or terminal block if daisy chain wiring required
australianmonitor.com.au
3
HAPI 3: INTERIMET E PORTIT AKSESOR (VAZHDIM.)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
WP4R, WP10, WPVOL instalime elektrike
WPBT instalime elektrike
1
Paging Audio +
2
Audioja e faqes -
3
RS485 A
4
+24 V DC
5
GND
6
RS485 B
7
Hyrja në distancë +
8
Hyrja në distancë -
*Unused if not daisy chaining
Instalime elektrike me zinxhir
*Unused unless connecting to downstream ZMPS
Instalime elektrike me zinxhir
australianmonitor.com.au
4
STEP 4: PORT TERMINATION DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.
1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches
VENDOSJA E NDËRMELËSIT TË TERMINALIT TË PORTËS AKSESORE
ONE PORT USED TERM BOTH PORTS USED TERM
Port 1 OR Port 2 used Port 3 OR Port 4 used
ON Port 1 AND Port 2 used OFF
ON
ON Port 3 AND Port 4 used OFF
Porta 5 OSE Porta 6 e përdorur
ON Port 5 AND Port 6 used OFF
Porta 7 OSE Porta 8 e përdorur
ON Port 7 AND Port 8 used OFF
2. Terminate the LAST RS485 accessory on the port cable run.
Përfundimi i stacionit paging
Përfundimi i panelit të murit
Examples:
ONE port used:
PORT TERM = ON
Terminate end points
BOTH Ports used:
PORT TERM = OFF
australianmonitor.com.au
5
HAPI 5: WP4R, WP10 GPO (OPCIONAL)
WP4R dhe WP10 kanë të dyja 3 dalje për qëllime të përgjithshme të cilat mund të kontrollohen nga butonat e panelit të murit për të aktivizuar pajisje të jashtme si projektorët.
Skema e GPO
Çdo dalje është një tranzistor me kolektor të hapur. Vëllimi maksimaltage: Rryma maksimale e lavamanit 48V: 250mA
Example: Relay Connection
24 V
Logjika e brendshme
GPO1
GPO2
GPO3
australianmonitor.com.au
6 GND
Dokumentet / Burimet
![]() |
ZONEMIX ZONEMIX4 Zone Controller [pdfUdhëzime ZONEMIX4, ZONEMIX4 Zone Controller, Zone Controller, Controller |