  • Supports up to 8 controllers per port
  • Supports ONE audio input PER accessory port
  • Supports up to 8 paging stations per port
  • Maximum cable length per port: 100m – 500m depending on
    na'urorin haɗi

Umarnin Amfani da samfur

Step 1: Decide Port Wiring Layout

Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.

Step 2: Confirm Limits

Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.

Step 3: Accessory Port Wiring

Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
cin hanci da rashawa.

ZONEMIX DA ZMPS WIRING

Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.

WP4R, WP10, WPVOL Wiring & WPBT Wiring

Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.

Umarnin Ƙarshe

  1. Terminate the ZONEMIX accessory ports based on which ports you
    use using the PORT TERM switches.
  2. Kashe kayan haɗi na LAST RS485 akan guduwar kebul na tashar jiragen ruwa.

FAQ

Q: How many controllers can be connected per port?

A: The system supports up to 8 controllers per port.

Q: Can multiple wall panels and paging stations be connected on
the same accessory port?

A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.

"'

JAGORAN FARKO

GABATARWA
Tashoshin na'urorin haɗi na ZONEMIX suna ba da damar haɗin haɗin bangon bango, tashoshi da wuraren shigar da sauti. Da fatan za a bi jagorar da ke ƙasa don saita tsarin ku.

Maɓalli:
ZONEMIX 4

ZONEMIX 8

Wall Controllers Audio Sources

Yana goyan bayan masu sarrafawa har 8 a kowane tashar jiragen ruwa. (duba shafi na 2 don cikakkun bayanai)

Yana goyan bayan shigarwar odiyo GUDA DAYA KOWANE tashar kayan haɗi.

Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.

Lura cewa na'urorin haɗi na tashar tashoshin shigar da sauti na gida an kulle su zuwa yankin fitarwa mai dacewa kuma ɗaya kaɗai za a iya amfani da shi a kowane yanki. Misali tashar haɗi na haɗi 1 shigarwar gida yana haɗawa zuwa Yanki 1. Koyaya, ana iya haɗa bangarorin bango da yawa da tashoshi a kan tashar kayan haɗi iri ɗaya.

australianmonitor.com.au

1

Mataki na 1: YANKE SHARI'AR WIRING PORT

Do you need local audio inputs?

Ee

A'a

Yi amfani da tashar haɗi ɗaya a kowane yanki. watau Port 1 zuwa Zone 1, Port 2 zuwa Zone 2 da dai sauransu. Kamar yadda abubuwan da ake shigar da sauti ke bukatar nasu gudummuwar gida.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s

Mataki na 2: TABBATAR DA KADA KA WUCE IYAKA.

Maximum cable length per port Accessories per port Maximum Accessories in system

100m

8

130m

7

180m

6

24

250m

5

400m

4

500m

3

The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.

australianmonitor.com.au

2

MATAKI NA 3: HANYAR WIRING PORT SHAFIN
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8

Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ZONEMIX

Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –

ZMPS
ZMPS DAISY sarkar WIRING

ZONEMIX

Use an RJ45 splitter or terminal block if daisy chain wiring required

australianmonitor.com.au

3

MATAKI NA 3: HANYAR WIRING PORT SHAFIN (CIGABA)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

WP4R, WP10, WPVOL WIRING

WPBT WIRING

1

Rubutun Sauti +

2

Rubutun Sauti -

3

RS485 A

4

+ 24V DC

5

GND

6

Saukewa: RS485B

7

Shigar da Nisa +

8

Shigar da Nisa -

*Unused if not daisy chaining
Daisy sarkar wiring

*Unused unless connecting to downstream ZMPS
Daisy sarkar wiring

australianmonitor.com.au

4

STEP 4: PORT TERMINATION ­ DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.

1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches

KAYAN KYAUTA PORT TERMINAL SWITCH SETTING

ONE PORT USED TERM BOTH PORTS USED TERM

Port 1 OR Port 2 used Port 3 OR Port 4 used

ON Port 1 AND Port 2 used OFF

ON

ON Port 3 AND Port 4 used OFF

Port 5 KO Port 6 amfani

ON Port 5 AND Port 6 used OFF

Port 7 KO Port 8 amfani

ON Port 7 AND Port 8 used OFF

2. Terminate the LAST RS485 accessory on the port cable run.

Ƙarshe tasha

Karewa panel panel

Exampda:
ONE port used:

PORT TERM = ON

Terminate end points

BOTH Ports used:

PORT TERM = OFF

australianmonitor.com.au

5

Mataki na 5: WP4R, WP10 GPO WIRING (ZABI)
WP4R da WP10 duka suna da abubuwan da aka fitar na gaba ɗaya na 3 waɗanda za'a iya sarrafa su daga maɓallan bangon bango don kunna na'urori na waje kamar na'urori.

Tsarin GPO
Kowane Fitarwa transistor ne mai tarin yawa. Matsakaicin Voltage: 48V Matsakaicin nutsewa Yanzu: 250mA

Example: Relay Connection
24V

Hankali na ciki

Saukewa: GPO1

Saukewa: GPO2

Saukewa: GPO3

australianmonitor.com.au

Farashin GND6

Takardu / Albarkatu

ZONEMIX ZONEMIX4 Zone Controller [pdf] Umarni
ZONEMIX4, ZONEMIX4 Zone Controller, Zone Controller, Controller

Magana

Bar sharhi

Ba za a buga adireshin imel ɗin ku ba. Ana yiwa filayen da ake buƙata alama *