Istruzzioni di u cuntrollore di zona ZONEMIX4

Cuntrollore di Zona ZONEMIX4

Specificazioni

  • Supports up to 8 controllers per port
  • Supports ONE audio input PER accessory port
  • Supports up to 8 paging stations per port
  • Maximum cable length per port: 100m – 500m depending on
    accessori

Istruzzioni per l'usu di u produttu

Step 1: Decide Port Wiring Layout

Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.

Step 2: Confirm Limits

Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.

Step 3: Accessory Port Wiring

Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
corruzzione.

ZONEMIX E ZMPS WIRING

Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.

WP4R, WP10, WPVOL Wiring & WPBT Wiring

Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.

Istruzzioni per a terminazione

  1. Terminate the ZONEMIX accessory ports based on which ports you
    use using the PORT TERM switches.
  2. Terminate l'ULTIMO accessori RS485 nantu à u cable di u portu.

FAQ

Q: How many controllers can be connected per port?

A: The system supports up to 8 controllers per port.

Q: Can multiple wall panels and paging stations be connected on
the same accessory port?

A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.

"'

GUIDA DI CABLAGGIU

INTRODUZIONE
I porti accessori ZONEMIX permettenu a cunnessione di pannelli di muru, stazioni di paginazione è fonti di input audio. Per piacè seguite a guida sottu per cunfigurà u vostru sistema.

Chjave:
ZONEMIX 4

ZONEMIX 8

Wall Controllers Audio Sources

Supporta finu à 8 controllers per portu. (vede a pagina 2 per i dettagli)

Supporta UNA entrata audio PER portu d'accessori.

Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.

Per piacè nutate chì i canali di input audio lucali di u portu d'accessori sò chjusi à a zona di output currispondente è solu unu pò esse usatu per zona. Per esempiu, u portu di l'accessori 1 l'input lucale si cunnetta à a Zona 1. In ogni casu, parechji pannelli murali è stazioni di paginazione ponu esse cunnessi nantu à u stessu portu d'accessori.

australianmonitor.com.au

1

STEP 1: DECIDE PORT WIRING LAYOUT

Do you need local audio inputs?

Innò

Aduprate un portu accessori per zona. ie Port 1 à Zone 1, Port 2 à Zone 2 etc. Cum'è inputs audio necessitanu u so propiu home run.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s

STEP 2: CONFIRM VOI ÙN SUCCEDE I LIMITI SEGUENTI

Maximum cable length per port Accessories per port Maximum Accessories in system

100 m

8

130 m

7

180 m

6

24

250 m

5

400 m

4

500 m

3

The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.

australianmonitor.com.au

2

STEP 3: WIRING PORT ACCESSORY
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8

Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ZONEMIX

Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –

ZMPS
CABLAGGIO ZMPS DAISY CHAIN

ZONEMIX

Use an RJ45 splitter or terminal block if daisy chain wiring required

australianmonitor.com.au

3

PASSU 3: CABLAGGI DI PORTU ACCESSORI (CONT.)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

WP4R, WP10, WPVOL WIRING

WPBT WIRING

1

Paging Audio +

2

Paging Audio -

3

RS485 A

4

+ 24 V DC

5

GND

6

RS485 B

7

Input Remote +

8

Input Remote -

*Unused if not daisy chaining
Cablaggio daisy chain

*Unused unless connecting to downstream ZMPS
Cablaggio daisy chain

australianmonitor.com.au

4

STEP 4: PORT TERMINATION ­ DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.

1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches

CONFIGURAZIONE DI INTERRUTTORE TERMINAL PORT ACCESSORY

ONE PORT USED TERM BOTH PORTS USED TERM

Port 1 OR Port 2 used Port 3 OR Port 4 used

ON Port 1 AND Port 2 used OFF

ON

ON Port 3 AND Port 4 used OFF

Port 5 OR Port 6 utilizatu

ON Port 5 AND Port 6 used OFF

Port 7 OR Port 8 utilizatu

ON Port 7 AND Port 8 used OFF

2. Terminate the LAST RS485 accessory on the port cable run.

Terminazione di a stazione di paginazione

Terminazione di u pannellu di muru

Examples:
ONE port used:

PORT TERM = ON

Terminate end points

BOTH Ports used:

PORT TERM = OFF

australianmonitor.com.au

5

PASSU 5: WP4R, WP10 GPO WIRING (OPZIONALE)
U WP4R è u WP10 anu 3 uscite di scopu generale chì ponu esse cuntrullati da i buttoni di u pannellu di u muru per attivà i dispositi esterni cum'è i proiettori.

Schema GPO
Ogni Output hè un transistor di cullezzione aperta. Massimu Voltage: 48V Corrente Massima Sink: 250mA

Example: Relay Connection
24V

Internal Logic

GPO1

GPO2

GPO3

australianmonitor.com.au

GND 6