ຕົວຄວບຄຸມເຂດ ZONEMIX4
“
ຂໍ້ມູນຈໍາເພາະ
- Supports up to 8 controllers per port
- Supports ONE audio input PER accessory port
- Supports up to 8 paging stations per port
- Maximum cable length per port: 100m – 500m depending on
ອຸປະກອນເສີມ
ຄໍາແນະນໍາການນໍາໃຊ້ຜະລິດຕະພັນ
Step 1: Decide Port Wiring Layout
Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.
Step 2: Confirm Limits
Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.
Step 3: Accessory Port Wiring
Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
ສໍ້ລາດບັງຫຼວງ.
ZONEMIX ແລະ ZMPS ສາຍໄຟ
Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.
WP4R, WP10, WPVOL Wiring & WPBT Wiring
Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.
ຄໍາແນະນໍາການຢຸດເຊົາ
- Terminate the ZONEMIX accessory ports based on which ports you
use using the PORT TERM switches. - ຢຸດອຸປະກອນເສີມ RS485 ສຸດທ້າຍໃນການແລ່ນສາຍພອດ.
FAQ
Q: How many controllers can be connected per port?
A: The system supports up to 8 controllers per port.
Q: Can multiple wall panels and paging stations be connected on
the same accessory port?
A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.
“`
ຄູ່ມືສາຍໄຟ
ແນະນຳ
ພອດອຸປະກອນເສີມ ZONEMIX ອະນຸຍາດໃຫ້ສໍາລັບການເຊື່ອມຕໍ່ຂອງຝາຜະຫນັງ, ສະຖານີຫນ້າແລະແຫຼ່ງປ້ອນສຽງ. ກະລຸນາປະຕິບັດຕາມຄໍາແນະນໍາຂ້າງລຸ່ມນີ້ເພື່ອຕັ້ງຄ່າລະບົບຂອງທ່ານ.
ກະແຈ:
ZONEMIX 4
ZONEMIX 8
Wall Controllers Audio Sources
ຮອງຮັບໄດ້ເຖິງ 8 ຕົວຄວບຄຸມຕໍ່ພອດ. (ເບິ່ງໜ້າ 2 ສຳລັບລາຍລະອຽດ)
ຮອງຮັບການປ້ອນຂໍ້ມູນສຽງດຽວຕໍ່ພອດອຸປະກອນເສີມ.
Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.
ກະລຸນາສັງເກດວ່າຊ່ອງສຽບການປ້ອນຂໍ້ມູນສຽງທ້ອງຖິ່ນພອດອຸປະກອນແມ່ນຖືກລັອກກັບເຂດການຜະລິດທີ່ສອດຄ້ອງກັນແລະມີພຽງແຕ່ຫນຶ່ງທີ່ສາມາດນໍາໃຊ້ຕໍ່ເຂດ. ເຊັ່ນ: ພອດອຸປະກອນເສີມ 1 ເຊື່ອມຕໍ່ທ້ອງຖິ່ນເຊື່ອມຕໍ່ກັບເຂດ 1. ແນວໃດກໍ່ຕາມ, ແຜງຜະໜັງຫຼາຍແຜ່ນ ແລະ ສະຖານີການສົ່ງຕໍ່ສາມາດເຊື່ອມຕໍ່ໄດ້ໃນພອດອຸປະກອນເສີມດຽວກັນ.
australianmonitor.com.au
1
ຂັ້ນຕອນທີ 1: ການຕັດສິນໃຈຮູບແບບສາຍໄຟ PORT
Do you need local audio inputs?
ແມ່ນແລ້ວ
ບໍ່
ໃຊ້ພອດອຸປະກອນເສີມໜຶ່ງຊ່ອງຕໍ່ເຂດ. ie Port 1 to Zone 1, Port 2 to Zone 2 ແລະອື່ນໆ. ເນື່ອງຈາກວ່າການປ້ອນຂໍ້ມູນສຽງຮຽກຮ້ອງໃຫ້ມີການແລ່ນເຮືອນຂອງຕົນເອງ.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s
ຂັ້ນຕອນທີ 2: ຢືນຢັນວ່າເຈົ້າບໍ່ເກີນຂອບເຂດຈໍາກັດຕໍ່ໄປນີ້
Maximum cable length per port Accessories per port Maximum Accessories in system
100ມ
8
130ມ
7
180ມ
6
24
250ມ
5
400ມ
4
500ມ
3
The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.
australianmonitor.com.au
2
ຂັ້ນຕອນທີ 3: ສາຍໄຟປອດອຸປະກອນ
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8.
Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ZONEMIX
Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –
ZMPS
ການສາຍສາຍໂສ້ ZMPS Daisy
ZONEMIX
Use an RJ45 splitter or terminal block if daisy chain wiring required
australianmonitor.com.au
3
ຂັ້ນຕອນທີ 3: ສາຍໄຟຊ່ອງສຽບອຸປະກອນເສີມ (CONT.)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
WP4R, WP10, WPVOL ສາຍໄຟ
ສາຍໄຟ WPBT
1
Paging ສຽງ +
2
Paging ສຽງ -
3
RS485 A
4
+24V DC
5
GND
6
RS485 ຂ
7
ການປ້ອນຂໍ້ມູນທາງໄກ +
8
ການປ້ອນຂໍ້ມູນໄລຍະໄກ -
*Unused if not daisy chaining
ສາຍໄຟຕ່ອງໂສ້ Daisy
*Unused unless connecting to downstream ZMPS
ສາຍໄຟຕ່ອງໂສ້ Daisy
australianmonitor.com.au
4
STEP 4: PORT TERMINATION DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.
1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches
ການຕັ້ງຄ່າສະວິດປອດອຸປະກອນເສີມ
ONE PORT USED TERM BOTH PORTS USED TERM
Port 1 OR Port 2 used Port 3 OR Port 4 used
ON Port 1 AND Port 2 used OFF
ON
ON Port 3 AND Port 4 used OFF
ພອດ 5 ຫຼື ພອດ 6 ໃຊ້
ON Port 5 AND Port 6 used OFF
ພອດ 7 ຫຼື ພອດ 8 ໃຊ້
ON Port 7 AND Port 8 used OFF
2. Terminate the LAST RS485 accessory on the port cable run.
ການຢຸດສະຖານີຫນ້າ
ການປິດຝາຜະໜັງ
Examples:
ONE port used:
PORT TERM = ON
Terminate end points
BOTH Ports used:
PORT TERM = OFF
australianmonitor.com.au
5
ຂັ້ນຕອນທີ 5: WP4R, WP10 GPO ສາຍໄຟ (ທາງເລືອກ)
WP4R ແລະ WP10 ທັງສອງມີ 3 ຜົນໄດ້ຮັບຈຸດປະສົງທົ່ວໄປທີ່ສາມາດຄວບຄຸມໄດ້ຈາກປຸ່ມກະດານກໍາແພງເພື່ອກະຕຸ້ນອຸປະກອນພາຍນອກເຊັ່ນໂປເຈັກເຕີ.
GPO Schematic
ແຕ່ລະຜົນຜະລິດແມ່ນ transistor ເກັບເປີດ. ສະບັບສູງສຸດtage: 48V ປະຈຸບັນ Sink ສູງສຸດ: 250mA
Example: Relay Connection
24V
Internal Logic
GPO1
GPO2
GPO3
australianmonitor.com.au
GND 6
ເອກະສານ / ຊັບພະຍາກອນ
![]() |
ZONEMIX ZONEMIX4 Zone Controller [pdf] ຄໍາແນະນໍາ ZONEMIX4, ZONEMIX4 Zone Controller, Zone Controller, Controller |