ZONEMIX4 Zone Controller
“
Zofotokozera
- Supports up to 8 controllers per port
- Supports ONE audio input PER accessory port
- Supports up to 8 paging stations per port
- Maximum cable length per port: 100m – 500m depending on
zowonjezera
Malangizo Ogwiritsira Ntchito Zogulitsa
Step 1: Decide Port Wiring Layout
Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.
Step 2: Confirm Limits
Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.
Step 3: Accessory Port Wiring
Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
ziphuphu.
ZONEMIX NDI ZMPS WRING
Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.
WP4R, WP10, WPVOL Wiring & WPBT Wiring
Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.
Malangizo Othetsa
- Terminate the ZONEMIX accessory ports based on which ports you
use using the PORT TERM switches. - Chotsani chowonjezera cha LAST RS485 pa chingwe cha doko.
FAQ
Q: How many controllers can be connected per port?
A: The system supports up to 8 controllers per port.
Q: Can multiple wall panels and paging stations be connected on
the same accessory port?
A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.
"``
WOTITSOGOLERA WIRING
MAU OYAMBA
Madoko owonjezera a ZONEMIX amalola kulumikizidwa kwa mapanelo a khoma, ma paging station ndi magwero olowera mawu. Chonde tsatirani kalozera pansipa kukhazikitsa dongosolo lanu.
Kiyi:
ZONEMIX 4
ZONEMIX 8
Wall Controllers Audio Sources
Imathandizira mpaka olamulira 8 pa doko lililonse. (onani tsamba 2 kuti mumve zambiri)
Imathandizira kulowetsa mawu MMODZI PA chowonjezera chowonjezera.
Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.
Chonde dziwani kuti tchanelo cholumikizira mawu am'deralo chatsekeredwa kumalo otulutsa ndipo imodzi yokha ndi yomwe ingagwiritsidwe ntchito pagawo lililonse. Mwachitsanzo, doko lolowera 1 lolowera komweko limalumikizana ndi Zone 1. Komabe, mapanelo angapo a khoma ndi mapeji amatha kulumikizidwa padoko lothandizira lomwelo.
australianmonitor.com.au
1
CHOCHITA 1: GANIZIRANI KUKHALA KWA WIRING PORT
Do you need local audio inputs?
Inde
Ayi
Gwiritsani ntchito doko limodzi pa zone iliyonse. mwachitsanzo, Port 1 kupita ku Zone 1, Port 2 kupita ku Zone 2 ndi zina zotero.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s
CHOCHITA CHACHIWIRI: SHIMIKIRANI KUTI SIMUPYOTSA MALIRE OTSATIRAWA
Maximum cable length per port Accessories per port Maximum Accessories in system
100m
8
130m
7
180m
6
24
250m
5
400m
4
500m
3
The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.
australianmonitor.com.au
2
CHOCHITA CHACHITATU: WAYA ZOTHANDIZA PA PORT
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8
Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ZONEMIX
Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –
ZMPS
ZMPS DAISY CHAIN WRING
ZONEMIX
Use an RJ45 splitter or terminal block if daisy chain wiring required
australianmonitor.com.au
3
CHOCHITA CHACHITATU: WIRING ZOTHANDIZA PA PORT (PITIRIZANI)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
WP4R, WP10, WPVOL WIRING
WPBT WIRING
1
Paging Audio +
2
Paging Audio -
3
Mtengo wa RS485A
4
+ 24V DC
5
GND
6
Mtengo wa RS485B
7
Zolowetsa Zakutali +
8
Zolowetsa Zakutali -
*Unused if not daisy chaining
Daisy chain wiring
*Unused unless connecting to downstream ZMPS
Daisy chain wiring
australianmonitor.com.au
4
STEP 4: PORT TERMINATION DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.
1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches
ACCESSORY PORT TERMINAL SWITCH SETTING
ONE PORT USED TERM BOTH PORTS USED TERM
Port 1 OR Port 2 used Port 3 OR Port 4 used
ON Port 1 AND Port 2 used OFF
ON
ON Port 3 AND Port 4 used OFF
Khomo 5 OR Port 6 yogwiritsidwa ntchito
ON Port 5 AND Port 6 used OFF
Khomo 7 OR Port 8 yogwiritsidwa ntchito
ON Port 7 AND Port 8 used OFF
2. Terminate the LAST RS485 accessory on the port cable run.
Kuyimitsa siteshoni yatsamba
Kutha kwa khoma
Exampzochepa:
ONE port used:
PORT TERM = ON
Terminate end points
BOTH Ports used:
PORT TERM = OFF
australianmonitor.com.au
5
CHOCHITA 5: WP4R, WP10 GPO WIRING (POSATHANDIZA)
WP4R ndi WP10 onse ali ndi zotuluka zitatu zomwe zimatha kuwongoleredwa kuchokera pamabatani apakhoma kuti ziyambitse zida zakunja monga ma projekiti.
GPO Schematic
Kutulutsa kulikonse ndi transistor yotseguka. Maximum Voltage: 48V Maximum Sink Current: 250mA
Example: Relay Connection
24V
Mfundo Zamkati
GPO1
GPO2
GPO3
australianmonitor.com.au
Mtengo wa GND6
Zolemba / Zothandizira
![]() |
ZONEMIX ZONEMIX4 Zone Controller [pdf] Malangizo ZONEMIX4, ZONEMIX4 Zone Controller, Zone Controller, Controller |