Vipimo

  • Supports up to 8 controllers per port
  • Supports ONE audio input PER accessory port
  • Supports up to 8 paging stations per port
  • Maximum cable length per port: 100m – 500m depending on
    vifaa

Maagizo ya Matumizi ya Bidhaa

Step 1: Decide Port Wiring Layout

Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.

Step 2: Confirm Limits

Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.

Step 3: Accessory Port Wiring

Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
rushwa.

WAYA WA ZONEMIX NA ZMPS

Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.

WP4R, WP10, WPVOL Wiring & WPBT Wiring

Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.

Maagizo ya Kukomesha

  1. Terminate the ZONEMIX accessory ports based on which ports you
    use using the PORT TERM switches.
  2. Sitisha nyongeza ya LAST RS485 kwenye kebo ya mlango inayoendeshwa.

Maswali Yanayoulizwa Mara kwa Mara

Q: How many controllers can be connected per port?

A: The system supports up to 8 controllers per port.

Q: Can multiple wall panels and paging stations be connected on
the same accessory port?

A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.

"`

MWONGOZO WA WIRING

UTANGULIZI
Bandari za nyongeza za ZONEMIX huruhusu uunganisho wa paneli za ukuta, vituo vya paging na vyanzo vya sauti. Tafadhali fuata mwongozo ulio hapa chini ili kusanidi mfumo wako.

Ufunguo:
ZONEMIX 4

ZONEMIX 8

Wall Controllers Audio Sources

Inaauni hadi vidhibiti 8 kwa kila mlango. (tazama ukurasa wa 2 kwa maelezo zaidi)

Inaauni ingizo MOJA la sauti KWA kila mlango wa nyongeza.

Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.

Tafadhali kumbuka kuwa lango la nyongeza la njia za kuingiza sauti za ndani zimefungwa kwa eneo linalolingana la pato na ni moja tu inayoweza kutumika kwa kila eneo. Kwa mfano, lango la nyongeza 1 ingizo la ndani linaunganishwa na Eneo la 1. Hata hivyo, paneli nyingi za ukutani na stesheni za kurasa zinaweza kuunganishwa kwenye mlango mmoja wa nyongeza.

australianmonitor.com.au

1

HATUA YA 1: AMUA MPANGO WA WAYA WA BANDARI

Do you need local audio inputs?

Ndiyo

Hapana

Tumia mlango mmoja wa nyongeza kwa kila eneo. yaani Bandari ya 1 hadi Eneo la 1, Bandari ya 2 hadi Eneo la 2 n.k. Kwa vile viingizi vya sauti vinahitaji uendeshaji wao wa nyumbani.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s

HATUA YA 2: THIBITISHA HUVUKI MIPAKA IFUATAYO

Maximum cable length per port Accessories per port Maximum Accessories in system

100m

8

130m

7

180m

6

24

250m

5

400m

4

500m

3

The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.

australianmonitor.com.au

2

HATUA YA 3: WIRING ZA KIFADHI CHA WIMBO
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8

Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ZONEMIX

Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –

ZMPS
ZMPS DAISY CHAIN ​​WIRING

ZONEMIX

Use an RJ45 splitter or terminal block if daisy chain wiring required

australianmonitor.com.au

3

HATUA YA 3: WAYA WA KUFUATILIA (CONT.)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

WP4R, WP10, WPVOL WIRING

WAYA WA WPBT

1

Sauti ya ukurasa +

2

Sauti ya ukurasa -

3

RS485 A

4

+24V DC

5

GND

6

RS485 B

7

Ingizo la Mbali +

8

Ingizo la Mbali -

*Unused if not daisy chaining
Daisy mnyororo wiring

*Unused unless connecting to downstream ZMPS
Daisy mnyororo wiring

australianmonitor.com.au

4

STEP 4: PORT TERMINATION ­ DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.

1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches

Mpangilio wa SWITCH TERMINAL BANDARI ACCESSORY

ONE PORT USED TERM BOTH PORTS USED TERM

Port 1 OR Port 2 used Port 3 OR Port 4 used

ON Port 1 AND Port 2 used OFF

ON

ON Port 3 AND Port 4 used OFF

Bandari ya 5 AU Bandari ya 6 imetumika

ON Port 5 AND Port 6 used OFF

Bandari ya 7 AU Bandari ya 8 imetumika

ON Port 7 AND Port 8 used OFF

2. Terminate the LAST RS485 accessory on the port cable run.

Kukomesha kwa kituo cha kurasa

Kukomesha kwa paneli za ukuta

Exampchini:
ONE port used:

PORT TERM = ON

Terminate end points

BOTH Ports used:

PORT TERM = OFF

australianmonitor.com.au

5

HATUA YA 5: WP4R, WP10 GPO WIRING (SI LAZIMA)
WP4R na WP10 zote zina matokeo 3 ya madhumuni ya jumla ambayo yanaweza kudhibitiwa kutoka kwa vitufe vya paneli za ukutani ili kuanzisha vifaa vya nje kama vile viboreshaji.

Mpango wa GPO
Kila Pato ni transistor wazi ya mtoza. Kiwango cha juu cha Voltage: 48V Upeo wa Sink ya Sasa: ​​250mA

Example: Relay Connection
24V

Mantiki ya Ndani

GPO1

GPO2

GPO3

australianmonitor.com.au

GND 6

Nyaraka / Rasilimali

ZONEMIX ZONEMIX4 Zone Controller [pdf] Maagizo
ZONEMIX4, ZONEMIX4 Zone Controller, Zone Controller, Controller

Marejeleo

Acha maoni

Barua pepe yako haitachapishwa. Sehemu zinazohitajika zimetiwa alama *