ZONEMIX4 ਜ਼ੋਨ ਕੰਟਰੋਲਰ ਨਿਰਦੇਸ਼

ZONEMIX4 ਜ਼ੋਨ ਕੰਟਰੋਲਰ

ਨਿਰਧਾਰਨ

  • Supports up to 8 controllers per port
  • Supports ONE audio input PER accessory port
  • Supports up to 8 paging stations per port
  • Maximum cable length per port: 100m – 500m depending on
    ਸਹਾਇਕ ਉਪਕਰਣ

ਉਤਪਾਦ ਵਰਤੋਂ ਨਿਰਦੇਸ਼

Step 1: Decide Port Wiring Layout

Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.

Step 2: Confirm Limits

Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.

Step 3: Accessory Port Wiring

Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
ਭ੍ਰਿਸ਼ਟਾਚਾਰ.

ZONEMIX ਅਤੇ ZMPS ਵਾਇਰਿੰਗ

Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.

WP4R, WP10, WPVOL Wiring & WPBT Wiring

Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.

ਸਮਾਪਤੀ ਦੀਆਂ ਹਦਾਇਤਾਂ

  1. Terminate the ZONEMIX accessory ports based on which ports you
    use using the PORT TERM switches.
  2. ਪੋਰਟ ਕੇਬਲ ਰਨ 'ਤੇ ਆਖਰੀ RS485 ਐਕਸੈਸਰੀ ਨੂੰ ਖਤਮ ਕਰੋ।

FAQ

Q: How many controllers can be connected per port?

A: The system supports up to 8 controllers per port.

Q: Can multiple wall panels and paging stations be connected on
the same accessory port?

A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.

"`

ਵਾਇਰਿੰਗ ਗਾਈਡ

ਜਾਣ-ਪਛਾਣ
ZONEMIX ਐਕਸੈਸਰੀ ਪੋਰਟਾਂ ਕੰਧ ਪੈਨਲਾਂ, ਪੇਜਿੰਗ ਸਟੇਸ਼ਨਾਂ ਅਤੇ ਆਡੀਓ ਇਨਪੁਟ ਸਰੋਤਾਂ ਦੇ ਕਨੈਕਸ਼ਨ ਦੀ ਆਗਿਆ ਦਿੰਦੀਆਂ ਹਨ। ਕਿਰਪਾ ਕਰਕੇ ਆਪਣੇ ਸਿਸਟਮ ਨੂੰ ਸਥਾਪਤ ਕਰਨ ਲਈ ਹੇਠਾਂ ਦਿੱਤੀ ਗਾਈਡ ਦੀ ਪਾਲਣਾ ਕਰੋ।

ਕੁੰਜੀ:
ਜ਼ੋਨਮਿਕਸ 4

ਜ਼ੋਨਮਿਕਸ 8

Wall Controllers Audio Sources

ਪ੍ਰਤੀ ਪੋਰਟ 8 ਕੰਟਰੋਲਰਾਂ ਤੱਕ ਦਾ ਸਮਰਥਨ ਕਰਦਾ ਹੈ। (ਵੇਰਵਿਆਂ ਲਈ ਪੰਨਾ 2 ਦੇਖੋ)

ਐਕਸੈਸਰੀ ਪੋਰਟ ਪ੍ਰਤੀ ਇੱਕ ਆਡੀਓ ਇੰਪੁੱਟ ਦਾ ਸਮਰਥਨ ਕਰਦਾ ਹੈ।

Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.

ਕਿਰਪਾ ਕਰਕੇ ਧਿਆਨ ਦਿਓ ਕਿ ਐਕਸੈਸਰੀ ਪੋਰਟ ਸਥਾਨਕ ਆਡੀਓ ਇਨਪੁਟ ਚੈਨਲਾਂ ਨੂੰ ਸੰਬੰਧਿਤ ਆਉਟਪੁੱਟ ਜ਼ੋਨ ਵਿੱਚ ਲਾਕ ਕੀਤਾ ਗਿਆ ਹੈ ਅਤੇ ਪ੍ਰਤੀ ਜ਼ੋਨ ਵਿੱਚ ਸਿਰਫ਼ ਇੱਕ ਹੀ ਵਰਤਿਆ ਜਾ ਸਕਦਾ ਹੈ। ਜਿਵੇਂ ਕਿ ਐਕਸੈਸਰੀ ਪੋਰਟ 1 ਲੋਕਲ ਇਨਪੁਟ ਜ਼ੋਨ 1 ਨਾਲ ਜੁੜਦਾ ਹੈ। ਹਾਲਾਂਕਿ, ਮਲਟੀਪਲ ਕੰਧ ਪੈਨਲ ਅਤੇ ਪੇਜਿੰਗ ਸਟੇਸ਼ਨ ਇੱਕੋ ਐਕਸੈਸਰੀ ਪੋਰਟ 'ਤੇ ਕਨੈਕਟ ਕੀਤੇ ਜਾ ਸਕਦੇ ਹਨ।

australianmonitor.com.au

1

ਕਦਮ 1: ਪੋਰਟ ਵਾਇਰਿੰਗ ਲੇਆਉਟ ਦਾ ਫੈਸਲਾ ਕਰੋ

Do you need local audio inputs?

ਹਾਂ

ਨੰ

ਪ੍ਰਤੀ ਜ਼ੋਨ ਇੱਕ ਐਕਸੈਸਰੀ ਪੋਰਟ ਦੀ ਵਰਤੋਂ ਕਰੋ। ਜਿਵੇਂ ਕਿ ਪੋਰਟ 1 ਤੋਂ ਜ਼ੋਨ 1, ਪੋਰਟ 2 ਤੋਂ ਜ਼ੋਨ 2 ਆਦਿ। ਜਿਵੇਂ ਕਿ ਆਡੀਓ ਇਨਪੁਟਸ ਨੂੰ ਆਪਣੇ ਘਰ ਚਲਾਉਣ ਦੀ ਲੋੜ ਹੁੰਦੀ ਹੈ।
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s

ਕਦਮ 2: ਪੁਸ਼ਟੀ ਕਰੋ ਕਿ ਤੁਸੀਂ ਨਿਮਨਲਿਖਤ ਸੀਮਾਵਾਂ ਨੂੰ ਪਾਰ ਨਹੀਂ ਕਰਦੇ

Maximum cable length per port Accessories per port Maximum Accessories in system

100 ਮੀ

8

130 ਮੀ

7

180 ਮੀ

6

24

250 ਮੀ

5

400 ਮੀ

4

500 ਮੀ

3

The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.

australianmonitor.com.au

2

ਕਦਮ 3: ਐਕਸੈਸਰੀ ਪੋਰਟ ਵਾਇਰਿੰਗ
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8

Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ਜ਼ੋਨਮਿਕਸ

Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –

ZMPS
ZMPS ਡੇਜ਼ੀ ਚੇਨ ਵਾਇਰਿੰਗ

ਜ਼ੋਨਮਿਕਸ

Use an RJ45 splitter or terminal block if daisy chain wiring required

australianmonitor.com.au

3

ਕਦਮ 3: ਐਕਸੈਸਰੀ ਪੋਰਟ ਵਾਇਰਿੰਗ (ਜਾਰੀ)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

WP4R, WP10, WPVOL ਵਾਇਰਿੰਗ

WPBT ਵਾਇਰਿੰਗ

1

ਪੇਜਿੰਗ ਆਡੀਓ +

2

ਪੇਜਿੰਗ ਆਡੀਓ -

3

RS485 ਏ

4

+24V DC

5

ਜੀ.ਐਨ.ਡੀ

6

ਆਰ.ਐੱਸ .485 ਬੀ

7

ਰਿਮੋਟ ਇੰਪੁੱਟ +

8

ਰਿਮੋਟ ਇਨਪੁਟ -

*Unused if not daisy chaining
ਡੇਜ਼ੀ ਚੇਨ ਵਾਇਰਿੰਗ

*Unused unless connecting to downstream ZMPS
ਡੇਜ਼ੀ ਚੇਨ ਵਾਇਰਿੰਗ

australianmonitor.com.au

4

STEP 4: PORT TERMINATION ­ DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.

1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches

ਐਕਸੈਸਰੀ ਪੋਰਟ ਟਰਮੀਨਲ ਸਵਿੱਚ ਸੈਟਿੰਗ

ONE PORT USED TERM BOTH PORTS USED TERM

Port 1 OR Port 2 used Port 3 OR Port 4 used

ON Port 1 AND Port 2 used OFF

ON

ON Port 3 AND Port 4 used OFF

ਪੋਰਟ 5 ਜਾਂ ਪੋਰਟ 6 ਵਰਤਿਆ ਗਿਆ

ON Port 5 AND Port 6 used OFF

ਪੋਰਟ 7 ਜਾਂ ਪੋਰਟ 8 ਵਰਤਿਆ ਗਿਆ

ON Port 7 AND Port 8 used OFF

2. Terminate the LAST RS485 accessory on the port cable run.

ਪੇਜਿੰਗ ਸਟੇਸ਼ਨ ਦੀ ਸਮਾਪਤੀ

ਕੰਧ ਪੈਨਲ ਸਮਾਪਤੀ

Examples:
ONE port used:

PORT TERM = ON

Terminate end points

BOTH Ports used:

PORT TERM = OFF

australianmonitor.com.au

5

ਕਦਮ 5: WP4R, WP10 GPO ਵਾਇਰਿੰਗ (ਵਿਕਲਪਿਕ)
WP4R ਅਤੇ WP10 ਦੋਵਾਂ ਵਿੱਚ 3 ਆਮ ਉਦੇਸ਼ ਆਉਟਪੁੱਟ ਹਨ ਜੋ ਬਾਹਰੀ ਡਿਵਾਈਸਾਂ ਜਿਵੇਂ ਕਿ ਪ੍ਰੋਜੈਕਟਰ ਨੂੰ ਟਰਿੱਗਰ ਕਰਨ ਲਈ ਕੰਧ ਪੈਨਲ ਬਟਨਾਂ ਤੋਂ ਨਿਯੰਤਰਿਤ ਕੀਤੇ ਜਾ ਸਕਦੇ ਹਨ।

GPO ਯੋਜਨਾਬੱਧ
ਹਰੇਕ ਆਉਟਪੁੱਟ ਇੱਕ ਖੁੱਲਾ ਕੁਲੈਕਟਰ ਟਰਾਂਜ਼ਿਸਟਰ ਹੁੰਦਾ ਹੈ। ਅਧਿਕਤਮ ਵੋਲtage: 48V ਅਧਿਕਤਮ ਸਿੰਕ ਵਰਤਮਾਨ: 250mA

Example: Relay Connection
24 ਵੀ

ਅੰਦਰੂਨੀ ਤਰਕ

GPO1

GPO2

GPO3

australianmonitor.com.au

ਜੀ ਐਨ ਡੀ 6