Mga Instruksyon sa ZONEMIX4 Zone Controller

ZONEMIX4 Zone Controller

Mga detalye

  • Supports up to 8 controllers per port
  • Supports ONE audio input PER accessory port
  • Supports up to 8 paging stations per port
  • Maximum cable length per port: 100m – 500m depending on
    mga accessories

Mga Instruksyon sa Paggamit sa Produkto

Step 1: Decide Port Wiring Layout

Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.

Step 2: Confirm Limits

Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.

Step 3: Accessory Port Wiring

Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
korapsyon.

ZONEMIX UG ZMPS WIRING

Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.

WP4R, WP10, WPVOL Wiring & WPBT Wiring

Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.

Mga Instruksyon sa Pagtapos

  1. Terminate the ZONEMIX accessory ports based on which ports you
    use using the PORT TERM switches.
  2. Tapuson ang KATAPUSAN nga RS485 accessory sa port cable run.

FAQ

Q: How many controllers can be connected per port?

A: The system supports up to 8 controllers per port.

Q: Can multiple wall panels and paging stations be connected on
the same accessory port?

A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.

“`

GIYA SA WIRING

PASIUNA
Ang ZONEMIX accessory ports nagtugot sa koneksyon sa mga wall panel, paging station ug audio input sources. Palihug sunda ang giya sa ubos aron ma-set up ang imong sistema.

yawe:
ZONEMIX 4

ZONEMIX 8

Wall Controllers Audio Sources

Nagsuporta hangtod sa 8 nga mga controller matag pantalan. (tan-awa ang pahina 2 para sa mga detalye)

Nagsuporta sa ONE audio input KADA accessory port.

Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.

Palihug timan-i nga ang accessory port nga lokal nga audio input channels gi-lock sa katumbas nga output zone ug usa ra ang magamit matag zone. Eg Accessory port 1 lokal nga input nagkonektar sa Zone 1. Apan, daghang mga wall panel ug paging station mahimong makonektar sa samang accessory port.

australianmonitor.com.au

1

LAKANG 1: DESISYON ANG PORT WIRING LAYOUT

Do you need local audio inputs?

Oo

Dili

Gamit ug usa ka accessory port kada zone. ie Port 1 ngadto sa Zone 1, Port 2 ngadto sa Zone 2 ug uban pa. Kay ang mga audio input nagkinahanglan sa ilang kaugalingong home run.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s

LAKANG 2: KUMPIRMA NGA DILI KA MOLABAW SA MASUNOD NGA LIMITASYON

Maximum cable length per port Accessories per port Maximum Accessories in system

100m

8

130m

7

180m

6

24

250m

5

400m

4

500m

3

The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.

australianmonitor.com.au

2

LAKANG 3: ACCESSORY PORT WIRING
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8

Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
ZONEMIX

Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –

ZMPS
ZMPS DAISY CHAIN ​​WIRING

ZONEMIX

Use an RJ45 splitter or terminal block if daisy chain wiring required

australianmonitor.com.au

3

LAKANG 3: ACCESSORY PORT WIRING (CONT.)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.

WP4R, WP10, WPVOL WIRING

WPBT WIRING

1

Paging Audio +

2

Paging Audio -

3

RS485 A

4

+ 24V DC

5

GND

6

RS485 B

7

Hilit nga Input +

8

Hilit nga Input -

*Unused if not daisy chaining
Daisy chain wiring

*Unused unless connecting to downstream ZMPS
Daisy chain wiring

australianmonitor.com.au

4

STEP 4: PORT TERMINATION ­ DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.

1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches

ACCESSORY PORT TERMINAL SWITCH SETTING

ONE PORT USED TERM BOTH PORTS USED TERM

Port 1 OR Port 2 used Port 3 OR Port 4 used

ON Port 1 AND Port 2 used OFF

ON

ON Port 3 AND Port 4 used OFF

Port 5 O Port 6 gigamit

ON Port 5 AND Port 6 used OFF

Port 7 O Port 8 gigamit

ON Port 7 AND Port 8 used OFF

2. Terminate the LAST RS485 accessory on the port cable run.

Pag-undang sa istasyon sa paging

Pagtapos sa panel sa dingding

Examples:
ONE port used:

PORT TERM = ON

Terminate end points

BOTH Ports used:

PORT TERM = OFF

australianmonitor.com.au

5

LAKANG 5: WP4R, WP10 GPO WIRING (OPTIONAL)
Ang WP4R ug WP10 parehong adunay 3 nga kinatibuk-ang katuyoan nga mga output nga mahimong kontrolado gikan sa mga buton sa panel sa dingding aron ma-trigger ang mga eksternal nga aparato sama sa mga projector.

GPO Schematic
Ang matag Output usa ka bukas nga kolektor transistor. Maximum nga Voltage: 48V Maximum Sink Current: 250mA

Example: Relay Connection
24V

Internal nga Logic

GPO1

GPO2

GPO3

australianmonitor.com.au

GND 6

Mga Dokumento / Mga Kapanguhaan

ZONEMIX ZONEMIX4 Zone Controller [pdf] Mga instruksiyon
ZONEMIX4, ZONEMIX4 Zone Controller, Zone Controller, Controller

Mga pakisayran

Pagbilin ug komento

Ang imong email address dili mamantala. Ang gikinahanglan nga mga natad gimarkahan *