HOLMAN PRO469 Multi Program Irrigation Controller
- Available in 6 and 9 station configurations
- Toroidal high capacity transformer rated to 1.25AMP (30VA)
- 3 programs, each with 4 start times, maximum of 12 start times per day
- Station run times from 1 minute to 12 hours and 59 minutes
- Selectable watering options: Individual 7 day selection, Even, Odd, Odd -31, interval watering day selection from every day to every 15th day
- Watering budgeting feature allows adjustment of station run times by percentage, from OFF to 200%, by month
- Rain sensor input to turn off stations during wet periods
- Permanent memory feature retains automatic programs during power failures
- Manual functions for program and station operation
- Pump output to drive a 24VAC coil
- Real-time clock backed up with 3V Lithium battery
- Contractor recall feature
Product Usage Instructions
Correct Power-up Procedure
- Connect the controller to AC power.
- Install a 9V battery to extend the life of the coin battery.
ProgrammingSet Automatic Program:
Manual OperationTo run a single station:
FAQs
How can I set the watering days?To set the watering days, navigate to the programming section and select the watering days option. Choose from options such as Individual 7 day selection, Even, Odd, etc., based on your requirements.
How does the rain sensor feature work?The rain sensor input will automatically turn off all stations or selected stations when it detects wet conditions. Ensure a rain sensor is installed and properly connected for this feature to function.
Introduction
- Your PRO469 Multi-Program Irrigation Controller is available in 6 and 9 station configurations.
- Designed to cover a wide range of applications from residential and commercial turf, to light agriculture, and professional nursery.
- This controller has a possible 3 separate programs with up to 12 starts per day. The controller has a 7 day watering schedule with individual day selection per program or a 365 calendar for odd/even day watering or selectable interval watering schedules from every day to every 15th day. Individual stations can be allocated to one or all programs and can have a run time of 1 minute to 12 hours 59 minutes or 25 hours if the water budget is set to 200%. Now with “Water Smart Seasonal Set” which allows the automatic run times to be adjusted in percentage from “OFF” to 200% per month.
- We have always been concerned with sustainable water usage. The controller has many water saving features that can be used to maintain the highest standard of plant quality with the least amount of water consumption. The integrated budget facility allows global changes of run times without affecting programmed run times. This allows for decreasing total water consumption on days of minimal evaporation.
Correct Power-up Procedure
- Connect to AC Power
- Install a 9V battery to increase the life of the coin battery
Batteries will maintain the clock
Features
- 6 and 9 station models
- Toroidal high capacity transformer rated to 1.25AMP (30VA)
- Outdoor model with an inbuilt transformer includes lead and plug, for Australia
- 3 programs, each of which has 4 start times, maximum of 12 start times per day
- Station run times from 1 minute to 12 hours and 59 minutes
- Selectable watering options: Individual 7 day selection, Even, Odd, Odd -31, interval watering day selection from every day to every 15th day
- Watering budgeting feature allows quick adjustment of the station run times by percentage, from OFF to 200%, by month
- Rain sensor input will turn off all stations or selected stations during wet periods, if a sensor is installed
- Permanent memory feature will retain automatic programs during power failures
- Manual functions: run a program or group of programs once, run a single station, with a test cycle for all stations, OFF position to stop a watering cycle or to stop automatic programs during winter
- Pump output to drive a 24VAC coil L Real-time clock backed up with 3V
- Lithium battery (pre-fitted)
- Contractor recall feature
Overview
Programming
This controller has been designed with 3 separate programs to allow different landscape areas to have their own individual watering schedules
A PROGRAM is a method of grouping stations (valves) with similar watering requirements to water on the same days. These stations will water in sequential order and on the days selected.
- Group the stations (valves) which are watering similar landscape areas together. For example, turf, flower beds, gardens–these different groups may require individual watering schedules, or PROGRAMS
- Set the current time and correct day of the week. If odd or even day watering is going to be used, make sure the current year, month and day of the month is correct
- To select a different PROGRAM, press
. Each press will move to the next PROGRAM number. This is handy for quick reviewing of previously entered information without losing your place in the programming cycle
Set Automatic Program
Set the automatic PROGRAM for each group of stations (valves) by completing the following three steps:
- Set watering START TIMES
For each start time, all the stations (valves) selected for the PROGRAM will come on in sequential order. If two start times are set, the stations (valves) will come on twice - Set WATER DAYS
- Set RUN TIME durations
This controller has been designed for quick intuitive programming. Remember these simple tips for hassle free programming:
- One push of a button will increment one unit
- Holding a button down will fast scroll through units During the programming, only flashing units are able to be set
- Adjust flashing units using
- Press
to scroll through settings as desired
- The MAIN DIAL is the primary device for selecting an operation
- Press
to select different PROGRAMS. Each push on this button will increment one PROGRAM number
Set Current Time, Day and Date
- Turn the dial to DATE+TIME
- Use
to adjust the flashing minutes
- Press
and then use
to adjust the flashing hours AM/PM must be set correctly.
- Press
and then use
to adjust the flashing days of the week
- Press
repeatedly until the calendar date appears on the display with the year flashing
The calendar only needs to be set when selecting odd/even day watering - Use
to adjust the year
- Press
and then use
to adjust the flashing month
- Press
and then use
to adjust the flashing date
To return to the clock, turn the dial back to AUTO
Set Start Times
All stations will run in sequential order for each start time
For this example, we will set a START TIME for PROG No. 1
- Turn the dial to START TIMES and ensure that PROG No. 1 is showing
If not, pressto cycle through the PROGRAMS and select PROG No. 1
- START No. will be flashing
- Use
to change the START No. if required
- Press
and the hours for your selected START No. will flash
- Use
to adjust if required
Ensure AM/PM is correct - Press
and the minutes will flash
- Use
to adjust if required
Each PROGRAM can have up to 4 START TIMES - To set an additional START TIME, press and
START No. 1 will flash
- Advance to START No. 2 by pressing
- Follow steps 4-7 above to set a START TIME for START No. 2
To enable or disable a START TIME, useor to set both the hours and minutes to zero
To cycle through and change PROGRAMS, pressrepeatedly
Set Watering Days
This unit has individual day, EVEN/ODD date, ODD-31 date and INTERVAL DAYS selection
Individual Day Selection:
Turn dial to WATER DAYS and PROG No. 1 will show - If not, use
to select PROG No. 1
- MON (Monday) will be flashing
- Use
to enable or disable watering for Monday respectively
- Use
to cycle through the days of the week
Active days will be shown withunderneath
ODD/EVEN Date Selection
Some regions only allow watering on odd dates if the house number is odd, or likewise for even dates
Turn dial to WATER DAYS and PROG No. 1 will show - Press
repeatedly to cycle past FRI until ODD DAYS or EVEN DAYS is showing accordingly
Pressagain for ODD-31 if necessary
The 365-day calendar must be set correctly for this feature, (see Set Current Time, Day and Date)
This controller will take leap years into account
Interval Day Selection
- Turn dial to WATER DAYS and PROG No. 1 will show
- Press
repeatedly to cycle past FRI until INTERVAL DAYS is showing accordingly
INTERVAL DAYS 1 will be flashing
Useto select from 1 to 15 day intervals
Example: INTERVAL DAYS 2 means the controller will run the program in 2 days time
The next active day is always changed to 1, meaning tomorrow is the first active day to run
Set Run Times
- This is the length of time that each station (valve) is scheduled to water on a particular program
- Maximum watering time is 12 hours 59 minutes for each station
- A station can be assigned to any or all of the possible 3 programs
- Turn the dial to RUN TIMES
STATION No. 1 will be flashing labelled as OFF, as shown above, meaning it has no RUN TIME programmed in it
The controller has permanent memory so when there is a power failure, even if the battery is not installed, the programmed values will be restored to the unit - Press
to select the station (valve) number
- Press
and OFF will flash
- Press
to adjust the RUN TIME minutes as desired
- Press
and the RUN TIME hours will flash
- Press
to adjust the RUN TIME hours as desired
- Press and the STATION No. will flash again
- Press or to select another station (valve), and repeat steps 2-7 above to set a RUN TIME
To turn a station OFF, set both the hours and minutes to 0, and the display will flash OFF as shown above
This completes the setup procedure for PROG No. 1
Set Additional Programs
Set schedules for up to 6 PROGRAMS by pressingwhen setting up START TIMES, WATERING DAYS and RUN TIMES as previously outlined
Although the controller will run automatic programs with the MAIN DIAL in any position (with the exception of OFF), we recommend to leaving the main dial on AUTO position when not programming or running manually
Manual Operation
Run a Single Station
® The maximum run time is 12 hours 59 minutes
- Turn the dial to RUN STATION
STATION No. 1 will be flashing
The default manual run time is 10 minutes–to edit this, see Edit the Default Manual Run Time below - Use
to select the desired station
The selected station will start running and the RUN TIME will decrease accordingly
If there is a pump or master valve connected,
PUMP A will be shown in the display, indicating the pump/master is active - Press
and the RUN TIME minutes will flash
- Use
to adjust the minutes
- Press
and the RUN TIME hours will flash
- Use
to adjust the hours
The unit will revert to AUTO after the time has lapsed
If you forget to turn the dial back to AUTO, the controller will still run programs - To stop watering immediately, turn the dial to OFF
Edit the Default Manual Run Time
- Turn the dial to RUN STATION STATION No. 1 will flash
- Press
and the RUN TIME minutes will flash
- Use
to adjust the RUN TIME minutes
- Press
and the default RUN TIME hours will flash
- Use
to adjust the RUN TIME hours
- Once the desired RUN TIME is set, press
to save this as the default manual RUN TIME
The new default will now always appear when the dial is turned to RUN STATION
Run a Program
- To manually run a complete program or to stack multiple programs to run, turn the dial to RUN PROGRAM
OFF will flash on the display - To enable a PROGRAM, press
and the display will change to ON
If no RUN TIME has been set for the desired PROGRAM, the above step will not work
3. To run the desired PROGRAM immediately, press
Stacking Programs
- There may be times when it is desirable to run more than one program manually
- The controller allows this to occur using its unique facility of enabling a program, before running it
- For example, to run PROG No. 1 and also PROG No. 2, the controller will manage stacking of the programs so they do not overlap
- Follow steps 1 and 2 of Run a Program to enable a single PROGRAM
- To select the next PROGRAM press P
- Enable the next PROGRAM by pressing
To disable a program number, press - Repeat steps 2-3 above to enable additional PROGRAMS
- Once all desired PROGRAMS have been enabled, they can be run by pressing
The controller will now run all PROGRAMS that have been enabled in sequential order
This method can be used to enable any, or all of the available programs on the controller.
When running programs in this mode the BUDGET % will alter the RUN TIMES of each individual station accordingly
Other Features
Stop Watering
- To stop an automatic or manual watering schedule, turn the dial to OFF
- For automatic watering remember to turn the dial back to AUTO, as OFF will stop any future watering cycles from occurring
Stacking Start Times
- Should you accidentally set the same START TIME on more than one PROGRAM, the controller will stack them in sequential order
- All programmed START TIMES will be watered from the highest number first
Automatic Backup
- This product is fitted with permanent memory.
This allows the controller to hold all stowed values even in the absence of power sources, which means that programmed information will never be lost - Fitting a 9V battery is recommended to extend the life of the coin battery but it will not provide sufficient power run the display
- If the battery is not fitted, the real time clock is backed up with a lithium coin battery that has been factory fitted–when the power returns the clock will be restored to the current time
- It is recommended that the 9V battery is fitted and it is changed every 12 months
- The display will show FAULT BAT in the display when the battery has a week left to run–when this occurs, replace the battery as soon as possible
- If the AC power is off, the display will not be visible
Rain Sensor
- When installing a rain sensor, first remove the factory fitted link between the C and R terminals as shown
- Replace with the two wires from the rain sensor into these terminals, polarity NOT required
- Toggle the SENSOR switch to ON
- Turn the dial to SENSOR to enable your rain sensor for individual stations
The default mode is ON for all stations
If a station is labelled ON on the display, this means your rain sensor will be able to control the valve in the instance of rain
Should you have a station that always needs to be watered, (such as an enclosed greenhouse, or plants that are under cover) the rain sensor can be turned OFF to continue watering during rainy conditions - To turn a station OFF, press
to cycle through and select the desired station, then press
- To toggle a station back ON, press
To disable the rain sensor and allow all stations to water, toggle the SENSOR switch to OFF
WARNING!
KEEP NEW OR USED BUTTON/COIN BATTERIES OUT OF REACH OF CHILDREN
The battery can cause severe or fatal injuries in 2 hours or less if it is swallowed or placed inside any part of the body. If you think batteries may have been swallowed or placed inside any part of the body, seek immediate medical attention
Contact the Australian Poisons Information Centre for 24/7 fast, expert advice: 13 11 26
Refer to your local government guidelines on how to correctly dispose of button/coin batteries.
Rain Delay
To adjust the timing of your rain sensor, this controller features a RAIN DELAY setting
This allows a specific delay time to elapse after the rain sensor has dried out before the station will water again.
- Turn the dial to SENSOR
- Press
to access the RAIN DELAY screen
The INTERVAL DAYS value will now be flashing - Use
to alter the rain delay time in increments of 24 hours at a time
A maximum delay of 9 days can be set
Pump Connection
This unit will allow stations to be assigned to a pump
The default position is that all stations are assigned to PUMP A
- To change individual stations, turn the dial to PUMP
- Press
to cycle through each station
- Use
to toggle PUMP A to ON or OFF respectively
Display Contrast
- To adjust the LCD contrast, turn the dial to PUMP
- Press
repeatedly until the display reads CON
- Use
to adjust the display contrast as desired
- To save your setting, turn the dial back to AUTO
Water Budgeting and Seasonal Adjustment
® Automatic station RUN TIMES can be adjusted
by percentage as the seasons change
L This will save valuable water as RUN TIMES
can be adjusted quickly in spring, summer, and
autumn to reduce or increase water usage
® For this function, it is important
to set the calendar correctly–see
Set Current Time, Day and Date for more details
- Turn the dial to BUDGET–the display will appear as follows:
This means the RUN TIMES are set to a BUDGET% of 100%
By default, the display will show the current MONTH
For example, if STATION No. 1 is set to 10 minutes then it will run for 10 minutes
If the BUDGET% changes to 50%, STATION No. 1 would now run for 5 minutes (50% of 10 minutes
The budget calculation is applied to all active STATIONS and RUN TIMES - Use
to cycle through the months 1 to 12
- Use
to adjust the BUDGET% in 10% increments for each month
This can be set for each month from OFF to 200%
The permanent memory function will retain the information - To return to the clock, turn the dial to AUTO
- If the BUDGET% for your current month is not 100%, this will be shown in the AUTO clock display
Fault Indication Feature
- This unit has a M205 1AMP glass fuse to protect the transformer from power surges, and an electronic fuse to protect the circuit from field or valve faults
The following fault indications can be displayed:
NO AC: Not connected to mains power or transformer not working
FAULT BAT: 9V battery not connected or needs to be replaced
System Test
- Turn the dial to TEST STATIONS
The system test will begin automatically
Your PRO469 will water every station sequentially for 2 minutes each - Press
to advance to the next station before the 2 minute period has elapsed
It is not possible to go backwards to a previous station
To restart the system test from STATION No. 1, turn the dial to OFF, and then back to TEST STATIONS
Clearing the Programs
As this unit has a permanent memory feature, thebest way to clear the PROGRAMS is as follows: - Turn the dial to OFF
- Press
twice until the display appears as follows:
- Press
to clear all PROGRAMS
The clock will be retained, and the other functions for setting START TIMES, WATERING DAYS and RUN TIMES will be cleared and returned to the start up settings
PROGRAMS can also be cleared by manually setting START TIMES, WATERING DAYS and RUN TIMES individually back to their defaults
Program Rescue Feature
- To upload Program Recall Feature turn the dial to OFF
press and simultaneously– LOAD UP will appear on the screen
- Press
to complete the process
To re-install Program Recall Feature turn the dial OFF and press
LOAD will appear on the screen
Pressto return to the original stored program
Installation
Mounting the Controller
- Install the controller near a 240VAC outlet–preferably in a house, garage, or exterior electrical cubicle
- For ease of operation, eye level placement is recommended
- Ideally, your controller location should not be exposed to rain or areas prone to flooding or heavy water
- This inbuilt controller comes with an internal transformer and is suitable for outdoor or indoor installation
- The housing is designed for outdoor installation but the plug needs to be installed in a weatherproof socket or under cover
- Fasten the controller using the key hole slot positioned externally on the top centre and the additional holes positioned internally under the terminal cover
Electrical Hook-up
All electrical work must be carried out in accordance with these instructions, following all applicable local, state and federal codes pertaining to the country of installation–failure to do so will void the controller’s warranty
Disconnect mains power supply before any maintenance work to the controller or valves is undertaken
Do not attempt to wire any high voltage items yourself, i.e. pumps and pump contactors or hard wiring the controller power supply to the mains–this is the field of a licensed electrician
Serious injury or death could result from improper hook up–if in doubt consult your regulatory body as to what is required
Field Wiring Connections
- Prepare wire for hook-up by cutting the wires to the correct length and stripping approximately 0.25 inches (6.0mm) of insulation from the end to be connected to the controller
- Ensure terminal block screws are loosened sufficiently to permit easy access for wire ends
- Insert stripped wire ends into the clamp aperture and tighten screws
Do not over tighten as this may damage the terminal block
A maximum of 0.75 amps may be supplied by any output - Check the inrush current of your solenoid coils before connecting more than two valves to any one station
Power Supply Connections
- It is recommended that the transformer is not connected to a 240VAC supply which is also servicing or supplying motors (such as air conditioners, pool pumps, refrigerators)
- Lighting circuits are suitable as power sources
Terminal Block Layout
- 24VAC 24VAC power supply connection
- COM Common wire connection to field wiring
- SENS Input for rain switch
- PUMP 1 Master valve or pump start output
- ST1–ST9 Station (valve) field connections
Use a 2 amp fuse
Valve Installation and Power Supply Connection
- The purpose of the master valve is to shut off the water supply to the irrigation system when there is a faulty valve or none of the stations are operating correctly
- It is used like a back-up valve or fail safe device and is installed at the start of the irrigation system where it is connected to the water supply line
Station Valve Installation
- Up to two 24VAC solenoid valves can be connected to each station output and wired back to the Common (C) connector
- With long cable lengths, voltage drop can be significant, especially when more than one coil is wired to a station
- As a good rule of thumb select your cable as follows: 0–50m cable dia 0.5mm
- L 50–100m cable dia 1.0mm
- L 100–200m cable dia 1.5mm
- L 200–400m cable dia 2.0mm
- When using multiple valves per station, the common wire needs to be larger to carry more current. In these circumstances choose a common cable one or two sizes larger than required
- When making connections in the field, only ever use gel filled or greased filled connectors. Most field failures occur due to poor connections. The better the connection here, and the better the waterproof seal the longer the system will perform without trouble
- To install a rain sensor, wire it between the Common (C) and the Rain Sensor (R) terminals as shown
Pump Start Relay Connection
- This controller does not provide mains power to drive a pump–a pump must be driven via an external relay and contactor setup.
- The controller provides a low voltage signal that actuates the relay which in turn enables the contactor and finally the pump
- Although the controller has permanent memory and thus a default program will not cause erroneous valve actuation as in some controllers, it is still good practice when using a system where the water supply comes from a pump to connect unused stations on the unit back to the last used station
- This in effect, inhibits the chances of the pump ever running against a closed head
Pump Protection (System Test)
- In some circumstances not all operational stations may be hooked up–for example, if the controller was capable of running 6 stations but there were only 4 field wires and solenoid valves available for connection
- This situation can pose a risk to a pump when the system test routine for the controller is initiated
- The system test routine sequences through all available stations on the controller
- In the above example this would mean stations 5 through to 6 would become active and would cause the pump to operate against a closed head
This could possibly cause permanent pump, pipe and pressure vessel damage
- It is mandatory if the system test routine is going to be used, that all unused, spare stations, should be linked together and then looped to the last working station with a valve on it
- Using this example, the connector block should be wired as per the diagram below
Single Phase Pump Installation
It is recommended to always use a relay between the controller and the pump starter
Troubleshooting
Symptom | Possible Cause | Suggestion |
No display | Faulty transformer or blown fuse | Check fuse, check field wiring, check transformer |
Single station not working |
Faulty solenoid coil, or break in field wire Check fault indicator in display | Check solenoid coil (a good solenoid coil should read around 33ohms on a multi meter). Test field cable for continuity.
Test Common cable for continuity |
No automatic start |
Programming error or blown fuse or transformer | If unit works manually then check the programming. If not then check the fuse, wiring and transformer. |
Buttons not responding |
Short on button or programming not correct. Unit may be in sleep mode and no AC power | Check instruction book to ensure programming is correct. If buttons still not responding then return panel to supplier or manufacturer |
System coming on at random |
Too many start times entered on automatic programs | Check number of start times entered on each program. All stations will run once for every start. If fault persists return panel to supplier |
Multiple stations running at once |
Possible faulty driver triac |
Check wiring and swap faulty station wire’s on the controller terminal block with known working stations. If the same outputs are still locked on, return panel to supplier or manufacturer |
Pump start chattering | Faulty relay or pump contactor | Electrician to check voltage on relay or contactor |
Display cracked or missing segments | Display damaged during transportation | Return panel to supplier or manufacturer |
Sensor input not working |
Sensor enable switch in the OFF position or faulty wiring |
Slide switch on front panel to the ON position, test all wiring and make sure the sensor is a normally closed type. Check programming to make sure sensor is enabled |
Pump not working on a specific station or program | Programming error with pump enable routine | Check programming, using the manual as a reference and correct mistakes |
Electrical Specifications
Electrical Outputs
- Power Supply
- Mains supply: This unit runs off a 240 volt 50 hertz single phase outlet
- The controller draws 30 watt at 240VAC
- The internal transformer reduces the 240VAC to an extra low voltage supply of 24VAC
- The internal transformer is fully compliant with AS/NZS 61558-2-6 and has been independently tested and judged to comply
- This unit has a 1.25AMP low energy, high efficient toroidal transformer for long life performance
- Electrical Power Supply:
- Input 24 volts 50/60Hz
- Electrical Outputs:
- Maximum of 1.0 amp
- To Solenoid Valves:
- 24VAC 50/60Hz 0.75 amps max
- Up to 2 valves per station on the inbuilt model
- To the Master Valve/Pump Start:
- 24VAC 0.25 amps max
- Transformer and fuse capacity must be compatible with output requirements
Overload Protection
- Standard 20mm M-205 1 amp fast blow glass fuse, protects against power surges and electronic fuse rated to 1AMP protects against field faults
- Faulty station skip function
Power Failure
- The controller has permanent memory and real time clock, so the data is always backed up even with the absence of all power
- The unit is factory fitted with a 3V CR2032 lithium battery with up to 10 years memory backup
- The 9V alkaline battery maintains the data during power outages, and is recommended to help maintain the life of the lithium battery
Tampering with the unit will void the warranty
- The batteries do not run the outputs. The internal transformer requires mains power to run the valves
Wiring
Output circuits should be installed and protected in accordance with wiring code for your location
Servicing
Servicing your Controller
The controller should always be serviced by an authorised agent. Follow these steps to return your unit:
- Turn the mains power off to the controller
If the controller is hard-wired, a qualified electrician will be required to remove the entire unit, depending on the fault - Proceed to either unplug and return the entire controller with transformer or disconnect the panel assembly only for servicing or repair
- Disconnect the 24VAC leads at the controller 24VAC terminals on the very left hand side of the terminal block
- Clearly mark or identify all valve wires according to the terminals they are connected to, (1–9)
This allows you to easily wire them back to the controller, maintaining your valve watering scheme - Disconnect valve wires from the terminal block
- Remove the complete panel from the controller housing by unscrewing the two screws in the lower corners of the fascia (both ends of the terminal block)
- Remove the complete controller from the wall unplugging the lead
- Carefully wrap the panel or controller in protective wrapping and pack in a suitable box and return to your service agent or the manufacturer
Tampering with the unit will void the warranty.
- Replace your controller panel by reversing this procedure.
The controller should always be serviced by an authorised agen
Warranty
3 Year Replacement Guarantee
- Holman offers a 3 year replacement guarantee with this product.
- In Australia our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
- As well as your statutory rights referred to above and any other rights and remedies you have under any other laws relating to your Holman product, we also provide you with a Holman guarantee.
- Holman guarantees this product against defects caused by faulty workmanship and materials for 3 years domestic use from the date of purchase. During this guarantee period Holman will replace any defective product. Packaging and instructions may not be replaced unless faulty.
- In the event of a product being replaced during the guarantee period, the guarantee on the replacement product will expire 3 years from the purchase date of the original product, not 3 years from the date of replacement.
- To the extent permitted by law, this Holman Replacement Guarantee excludes liability for consequential loss or any other loss or damage caused to property of persons arising from any cause whatsoever. It also excludes defects caused by the product not being used in accordance with instructions, accidental damage, misuse, or being tampered with by unauthorised persons, excludes normal wear and tear and does not cover the cost of claiming under the warranty or transporting the goods to and from the place of purchase.
- Should you suspect your product may be defective and need some clarification or advice please contact us directly:
1300 716 188
support@holmanindustries.com.au
11 Walters Drive, Osborne Park 6017 WA - If you are certain your product is defective and is covered by the terms of this warranty, you will need to present your defective product and your purchase receipt as proof of purchase to the place you purchased it from, where the retailer will replace the product for you on our behalf.
We really appreciate having you as a customer, and would like to say thank you for choosing us. We recommend registering your new product on our website. This will ensure we have a copy of your purchase and activate an extended warranty. Keep up to date to with relevant product information and special offers available through our newsletter.
www.holmanindustries.com.au/product-registration/
Thanks again for choosing Holman
Documents / Resources
![]() |
HOLMAN PRO469 Multi Program Irrigation Controller [pdf] User Guide PRO469 Multi Program Irrigation Controller, PRO469, Multi Program Irrigation Controller, Program Irrigation Controller, Irrigation Controller, Controller |