Logo NASIONAL.Pedoman Miwiti GAMBANG
USRP-2920/2921/2922
Piranti Radio sing Ditetepake Piranti Lunak USRP

LAYANAN KOMPREHENSIF
Kita nawakake layanan perbaikan lan kalibrasi sing kompetitif, uga dokumentasi sing gampang diakses lan sumber daya sing bisa didownload gratis.
Adol SURPLUS Panjenengan
We tuku bagean anyar, digunakake, decommissioned, lan keluwihan saka saben seri NI. Kita ngupayakake solusi sing paling apik sing cocog karo kabutuhan individu.

INSTRUMEN NASIONAL USRP Software Defined Radio Device - lambang 1Jual Kanggo Cash
INSTRUMEN NASIONAL USRP Software Defined Radio Device - lambang 1Entuk Kredit
INSTRUMEN NASIONAL USRP Software Defined Radio Device - lambang 1Trade-In Deal
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Dianyari, lan Reconditioned NI Hardware.

Nggawe jurang antarane pabrikan lan sistem tes warisan sampeyan.
ARAD CMPIT4G Allegro Cellular PIT Module - ikon 21-800-915-6216
ARAD CMPIT4G Allegro Cellular PIT Module - ikon 3www.apexwaves.com
RENPHO RF FM059HS WiFi Smart Foot Massager - ikon 5sales@apexwaves.com

Dokumen iki nerangake carane nginstal, ngatur, lan nyoba piranti USRP ing ngisor iki:

  • Piranti Radio sing Ditetepake Piranti Lunak USRP-2920
  • Piranti Radio sing Ditetepake Piranti Lunak USRP-2921
  • Piranti Radio sing Ditetepake Piranti Lunak USRP-2922

Piranti USRP-2920/2921/2922 bisa ngirim lan nampa sinyal kanggo digunakake ing macem-macem aplikasi komunikasi. Piranti iki dikirim nganggo driver instrumen NI-USRP, sing bisa digunakake kanggo program piranti kasebut.

Verifikasi Persyaratan Sistem

Kanggo nggunakake driver instrumen NI-USRP, sistem sampeyan kudu nyukupi syarat tartamtu.
Waca produk readme, sing kasedhiya ing media piranti lunak driver utawa online ing ni.com/manuals, kanggo informasi luwih lengkap babagan syarat sistem minimal, sistem sing disaranake, lan lingkungan pangembangan aplikasi (ADEs) sing didhukung.

Mbukak Pack Kit

Stiebel Eltron CON 5 Premium Wall dipasang convector heater - cathetanKabar Kanggo nyegah discharge elektrostatik (ESD) saka ngrusak piranti, lemah dhewe nggunakake tali grounding utawa nyekeli obyek grounded, kayata sasis komputer.

  1. Tutul paket antistatik menyang bagean logam saka sasis komputer.
  2. Copot piranti saka paket lan mriksa piranti kanggo komponen ngeculke utawa tandha karusakan liyane.
    Stiebel Eltron CON 5 Premium Wall dipasang convector heater - cathetanKabar Aja ndemek pin konektor sing katon.
    AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Aja nginstal piranti yen katon rusak ing sembarang cara.
  3. Mbukak paket item lan dokumentasi liyane saka kit.
    Simpen piranti ing paket antistatik nalika piranti ora digunakake.

Verifikasi Isi Kit

INSTRUMEN NATIONAL USRP Software Defined Radio Piranti - Kit

1. Piranti USRP 4. SMA (m)-kanggo-SMA (m) Kabel
2. Sumber Daya AC/DC lan Kabel Daya 5. 30 dB SMA Attenuator
3. Kabel Ethernet Shielded 6. Pandhuan Miwiti (Dokumen Iki) lan Dokumen Informasi Keamanan, Lingkungan, lan Peraturan

Stiebel Eltron CON 5 Premium Wall dipasang convector heater - cathetanKabar Yen sampeyan langsung nyambung utawa kabel generator sinyal kanggo piranti, utawa yen sampeyan nyambungake sawetara piranti USRP bebarengan, sampeyan kudu nyambungake 30 DB attenuator kanggo input RF (RX1 utawa RX2) saben piranti USRP nampa.

Item sing dibutuhake liyane
Saliyane isi kit, sampeyan kudu nyedhiyani komputer karo antarmuka Ethernet gigabit kasedhiya.
Item Pilihan

  • LabVIEW Modulation Toolkit (MT), kasedhiya kanggo download ing ni.com/downloads lan kalebu ing LabVIEW Suite Desain Sistem Komunikasi, sing kalebu MT VI lan fungsi, contoneamples, lan dokumentasi
    AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Sampeyan kudu nginstal LabVIEW Modulasi Toolkit kanggo operasi sing tepat saka NI-USRP Modulation Toolkit examplan VI.
  • LabVIEW Digital Filter Design Toolkit, kasedhiya kanggo download ing ni.com/downloads lan kalebu ing LabVIEW Suite Desain Sistem Komunikasi
  • LabVIEW MathScript RT Modul, kasedhiya kanggo download ing ni.com/downloads
  • Sinkronisasi USRP MIMO lan kabel data, kasedhiya ing ni.com, kanggo nyinkronake sumber jam
  • Kabel SMA (m)-kanggo-SMA (m) tambahan kanggo nyambungake loro saluran karo piranti eksternal utawa nggunakake sinyal REF IN lan PPS IN

Pedoman Lingkungan

Stiebel Eltron CON 5 Premium Wall dipasang convector heater - cathetanKabar Model iki mung ditrapake kanggo aplikasi njero ruangan

Karakteristik Lingkungan

Suhu operasi 0 °C nganti 45 °C
Kelembapan operasi Kelembapan relatif 10% nganti 90%, noncondensing
Gelar polusi 2
Dhuwur maksimal 2,000 m (800 mbar) (ing suhu sekitar 25 °C)

Nginstal Piranti Lunak

Sampeyan kudu dadi Administrator kanggo nginstal software NI ing komputer.

  1. Instal lingkungan pangembangan aplikasi (ADE), kayata LabVIEW utawa LabVIEW Suite Desain Sistem Komunikasi.
  2. Tindakake pandhuan ing ngisor iki sing cocog karo ADE sing sampeyan instal.

Nginstal Software Nggunakake NI Package Manager
Priksa manawa sampeyan wis nginstal versi paling anyar saka NI Package Manager. Kanggo ngakses kaca download kanggo NI Package Manager, bukak ni.com/info lan ketik kode info NIPMDownload.
AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan NI-USRP versi 18.1 kanggo saiki kasedhiya kanggo download nggunakake NI Package Manager. Kanggo ndownload versi NI-USRP liyane, deleng Instal
Piranti Lunak Nggunakake Kaca Download Driver.

  1. Kanggo nginstal driver instrumen NI-USRP paling anyar, bukak NI Package Manager.
  2. Ing tab JELAJAH PRODUK, klik Drivers kanggo nampilake kabeh driver sing kasedhiya.
  3. Pilih NI-USRP dan klik INSTALL.
  4. Tindakake pandhuan ing pandhuan instalasi.
    AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Pangguna Windows bisa ndeleng akses lan pesen keamanan nalika instalasi. Nampa pituduh kanggo ngrampungake instalasi.

Informasi sing gegandhengan
Waca NI Package Manager Manual kanggo instruksi babagan nginstal driver nggunakake NI Package Manager.

Nginstal Piranti Lunak Nggunakake Kaca Download Driver
AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan NI nyaranake nggunakake NI Package Manager kanggo ngundhuh piranti lunak driver NI-USRP.

  1. Bukak ni.com/info lan ketik Info Code usrpdriver kanggo ngakses kaca download driver kanggo kabeh versi piranti lunak NI-USRP.
  2. Download versi piranti lunak driver NI-USRP.
  3. Tindakake pandhuan ing pandhuan instalasi.
    AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Pangguna Windows bisa ndeleng akses lan pesen keamanan nalika instalasi. Nampa pituduh kanggo ngrampungake instalasi.
  4. Nalika installer rampung, pilih Mati ing kothak dialog sing njaluk sampeyan miwiti maneh, mateni, utawa miwiti maneh mengko.

Nginstal Piranti
Instal kabeh piranti lunak sing arep digunakake sadurunge nginstal hardware.
AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Piranti USRP nyambung menyang komputer host nggunakake antarmuka Ethernet gigabit standar. Deleng dokumentasi kanggo antarmuka Ethernet gigabit kanggo instruksi instalasi lan konfigurasi.

  1. Daya ing komputer.
  2. Pasang antena utawa kabel menyang terminal panel ngarep piranti USRP kaya sing dikarepake.
  3. Gunakake kabel Ethernet kanggo nyambungake piranti USRP menyang komputer. Kanggo throughput maksimum liwat Ethernet, NI ngajak sampeyan nyambungake saben piranti USRP kanggo antarmuka Ethernet gigabit darmabakti dhewe ing komputer inang.
  4. Sambungake sumber daya AC/DC menyang piranti USRP.
  5. Tancepake sumber daya menyang stopkontak tembok. Windows kanthi otomatis ngenali piranti USRP.

Sinkronisasi Multiple Piranti (Opsional)
Sampeyan bisa nyambungake rong piranti USRP supaya padha nuduhake jam lan sambungan Ethernet kanggo inang.

  1. Sambungake kabel MIMO menyang port MIMO EXPANSION saben piranti.
    INSTRUMEN NATIONAL USRP Software Defined Radio Piranti - Piranti
  2. Yen sampeyan durung nindakake, pasang antena menyang piranti USRP.
    Yen sampeyan pengin nggunakake piranti USRP siji minangka panrima lan liyane minangka pemancar, pasang antena siji menyang port RX 1 TX 1 pemancar, lan pasang antena liyane menyang
    RX 2 port panrima.

Driver NI-USRP dikirim karo sawetara mantanamples sing bisa digunakake kanggo njelajah sambungan MIMO, kalebu USRP EX Rx Multiple Sinkronisasi Input (MIMO Expansion) lan USRP EX Tx Multiple Sinkronisasi Output (MIMO Expansion).

Konfigurasi Piranti

Nggawe Jaringan (Ethernet Mung)
Piranti kasebut komunikasi karo komputer host liwat Ethernet gigabit. Nggawe jaringan kanggo ngaktifake komunikasi karo piranti.
AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Alamat IP kanggo komputer host lan saben piranti USRP sing disambungake kudu unik.
Konfigurasi Antarmuka Ethernet Inang kanthi Alamat IP Statis
Alamat IP standar kanggo piranti USRP yaiku 192.168.10.2.

  1. Priksa manawa komputer host nggunakake alamat IP statis.
    Sampeyan bisa uga kudu ngowahi setelan jaringan kanggo sambungan area lokal nggunakake Panel Kontrol ing komputer host. Nemtokake alamat IP statis ing kaca Properti kanggo Internet Protocol Version 4 (TCP/IPv4).
  2. Ngatur antarmuka Ethernet host karo alamat IP statis ing subnet padha karo piranti sing disambungake kanggo ngaktifake komunikasi, minangka ditampilake ing tabel ing ngisor iki.

Tabel 1. Alamat IP statis

Komponen alamat
Host Ethernet antarmuka alamat IP statis 192.168.10.1
Host Ethernet antarmuka subnet mask 255.255.255.0
Alamat IP piranti USRP standar 192.168.10.2

AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan NI-USRP nggunakake pangguna datagram protocol (UDP) paket siaran kanggo nemokake piranti. Ing sawetara sistem, firewall mblokir paket siaran UDP.
NI nyaranake sampeyan ngganti utawa mateni setelan firewall kanggo ngidini komunikasi karo piranti.
Ngganti Alamat IP
Kanggo ngganti alamat IP piranti USRP, sampeyan kudu ngerti alamat saiki piranti, lan sampeyan kudu ngatur jaringan.

  1. Priksa manawa piranti sampeyan urip lan disambungake menyang komputer nggunakake antarmuka Ethernet gigabit.
  2. Pilih Start»All Programs»National Instruments»NI-USRP»NI-USRP Configuration Utility kanggo mbukak NI-USRP Configuration Utility, kaya sing ditampilake ing gambar ing ngisor iki.
    INSTRUMEN NASIONAL USRP Software Defined Radio Piranti - ProgramPiranti sampeyan kudu katon ing dhaptar ing sisih kiwa tab.
  3. Pilih tab Piranti saka utilitas.
  4. Ing dhaptar, pilih piranti sing pengin diganti alamat IP.
    Yen sampeyan duwe sawetara piranti, priksa manawa sampeyan milih piranti sing bener.
    Alamat IP piranti sing dipilih ditampilake ing kothak teks Alamat IP sing Dipilih.
  5. Ketik alamat IP anyar kanggo piranti ing kothak teks Alamat IP Anyar.
  6. Klik tombol Ganti Alamat IP utawa pencet kanggo ngganti alamat IP.
    Alamat IP piranti sing dipilih ditampilake ing kothak teks Alamat IP sing Dipilih.
  7. Utilitas njaluk sampeyan konfirmasi pilihan sampeyan. Klik OK yen pilihan sampeyan bener; yen ora, klik Batal.
  8. Utilitas nampilake konfirmasi kanggo nuduhake proses wis rampung. Klik OK.
  9. Siklus daya piranti kanggo ngetrapake owah-owahan.
  10. Sawise ngganti alamat IP, sampeyan kudu nggawe siklus daya piranti lan klik Refresh Dhaptar Piranti ing sarana kanggo nganyari dhaptar piranti.

Konfirmasi Sambungan Jaringan

  1. Pilih Start»All Programs» National Instruments NI-USRP»NI-USRP
    Utilitas Konfigurasi kanggo mbukak Utilitas Konfigurasi NI-USRP.
  2. Pilih tab Piranti saka utilitas.

Piranti sampeyan kudu katon ing kolom ID Piranti.
Cathetan Yen piranti sampeyan ora kadhaptar, priksa manawa piranti diuripake lan disambungake kanthi bener, banjur klik tombol Refresh Dhaptar Piranti kanggo mindai piranti USRP.

Konfigurasi Multiple Piranti nganggo Ethernet
Sampeyan bisa nyambungake sawetara piranti kanthi cara ing ngisor iki:

  • Multiple Ethernet antarmuka-Siji piranti kanggo saben antarmuka
  • Antarmuka Ethernet tunggal-Sawijining piranti sing disambungake menyang antarmuka, kanthi piranti tambahan sing disambungake nggunakake kabel MIMO opsional
  • Antarmuka Ethernet Tunggal - Akeh piranti sing disambungake menyang saklar sing ora dikelola
    INSTRUMEN NASIONAL USRP Software Defined Radio Device - lambang 2 Tip Nuduhake antarmuka Ethernet gigabit siji ing antarane piranti bisa nyuda throughput sinyal sakabèhé. Kanggo throughput sinyal maksimum, NI nyaranake sampeyan nyambungake ora luwih saka siji piranti saben antarmuka Ethernet.

Multiple Antarmuka Ethernet
Kanggo ngatur macem-macem piranti disambungake menyang antarmuka Ethernet gigabit kapisah, nemtokake saben antarmuka Ethernet subnet kapisah, lan nemtokake piranti sing cocog alamat ing subnet sing, minangka ditampilake ing tabel ing ngisor iki.

piranti Host Alamat IP Host Subnet Mask Alamat IP piranti
Piranti USRP 0 192.168.10.1 255.255.255.0 192.168.10.2
Piranti USRP 1 192.168.11.1 255.255.255.0 192.168.11.2

Antarmuka Ethernet Tunggal—Siji Piranti
Sampeyan bisa ngatur sawetara piranti nggunakake antarmuka Ethernet host siji nalika piranti disambungake kanggo saben liyane nggunakake kabel MIMO.

  1. Nemtokake saben piranti alamat IP kapisah ing subnet antarmuka Ethernet host, minangka ditampilake ing tabel ing ngisor iki.
    Tabel 3. Antarmuka Ethernet Host Tunggal-Konfigurasi MIMO
    piranti Host Alamat IP Host Subnet Mask Alamat IP piranti
    Piranti USRP 0 192.168.10.1 255.255.255.0 192.168.10.2
    Piranti USRP 1 192.168.11.1 255.255.255.0 192.168.11.2
  2. Sambungake Piranti 0 menyang antarmuka Ethernet lan sambungake Piranti 1 menyang Piranti 0 nggunakake kabel MIMO.

Antarmuka Ethernet Tunggal — Akeh Piranti sing Disambungake menyang Switch sing Ora Diurus
Sampeyan bisa nyambungake macem-macem piranti USRP menyang komputer inang liwat gigabit Ethernet ngalih unmanaged sing ngidini siji gigabit Ethernet adaptor ing komputer kanggo antarmuka karo sawetara piranti USRP disambungake menyang ngalih.
Nemtokake antarmuka Ethernet host subnet, lan nemtokake saben piranti alamat ing subnet, minangka ditampilake ing tabel ing ngisor iki.
Tabel 4. Single Host Ethernet Interface-Konfigurasi Ngalih Unmanaged

piranti Host Alamat IP Host Subnet Mask Alamat IP piranti
Piranti USRP 0 192.168.10.1 255.255.255.0 192.168.10.2
Piranti USRP 1 192.168.11.1 255.255.255.0 192.168.11.2

Pemrograman Piranti

Sampeyan bisa nggunakake driver instrumen NI-USRP kanggo nggawe aplikasi komunikasi kanggo piranti USRP.
Driver Instrumen NI-USRP
Driver instrumen NI-USRP nduweni sakumpulan fungsi lan sifat sing nggunakake kemampuan piranti USRP, kalebu konfigurasi, kontrol, lan fungsi khusus piranti liyane.
Informasi sing gegandhengan
Waca Manual NI-USRP kanggo informasi babagan nggunakake driver instrumen ing aplikasi sampeyan.
NI-USRP Eksamples lan Piwulang
NI-USRP kalebu sawetara examppelajaran lan pelajaran kanggo LabVIEW, LabVIEW NXG, lan LabVIEW Suite Desain Sistem Komunikasi. Bisa digunakake kanthi individu utawa minangka komponen aplikasi liyane.
NI-USRP eksamppelajaran lan pelajaran kasedhiya ing lokasi ing ngisor iki.

Isi
Jinis
Katrangan LabVIEW LabVIEW NXG 2.1 kanggo Saiki utawa LabVIEW
Suite Desain Sistem Komunikasi
2.1 nganti Saiki
Examples NI-USRP kalebu sawetara exampaplikasi sing dadi alat interaktif, model pemrograman, lan blok bangunan ing aplikasi sampeyan dhewe. NI-USRP kalebu examples kanggo
miwiti lan fungsi radio ditetepake piranti lunak (SDR) liyane.
Wigati Sampeyan bisa ngakses ex tambahanamples saka Komunitas Enggo bareng Kode ing
ni. com/usrp.
• Saka menu Mulai ing Mulai» Kabeh Program» Instrumen Nasional »N I- USRP» Examples.
• Saka LabVIEW Palet fungsi ing Instrumen 1/0»Instrument Drivers»NIUSRP» Examples.
• Saka tab Learning, pilih Examples» Input lan Output Hardware» NiUSRP.
• Saka tab Learning, pilih Examples» Input lan Output Hardware NI USRP RIO.
wulangan NI-USRP kalebu pelajaran sing nuntun sampeyan ing proses ngenali lan demodulasi sinyal FM nganggo piranti sampeyan. Saka tab Pembelajaran, pilih Pelajaran» Miwiti» Demodulasi Sinyal FM nganggo NI… lan pilih tugas sing kudu ditindakake.

Cathetan NI Example Finder ora kalebu NI-USRP examples.

Verifikasi Sambungan Piranti (Opsional)
Verifikasi Sambungan Piranti Nggunakake LabVIEW NXG utawa
LabVIEW Desain Sistem Komunikasi Suite 2.1 nganti Saiki
Gunakake USRP Rx Continuous Async kanggo konfirmasi yen piranti nampa sinyal lan disambungake kanthi bener menyang komputer host.

  1. Navigasi menyang Learning»Examples »Input lan Output Hardware»NI-USRP»NI-USRP.
  2. Pilih Rx Continuous Async. Klik Nggawe.
  3. Jalanake USRP Rx Continuous Async.
    Yen piranti nampa sinyal sampeyan bakal weruh data ing grafik panel ngarep.
  4. Klik STOP kanggo ngrampungake tes.

Verifikasi Sambungan Piranti Nggunakake LabVIEW
Nindakake tes loopback kanggo konfirmasi manawa piranti ngirim lan nampa sinyal lan disambungake kanthi bener menyang komputer host.

  1. Pasang atenuator 30 dB sing kalebu ing salah sawijining ujung kabel SMA (m) -ka-SMA (m).
  2. Sambungake atenuator 30 dB menyang konektor RX 2 TX 2 ing panel ngarep piranti USRP lan sambungake ujung liyane kabel SMA (m) -kanggo-SMA (m) menyang port RX 1 TX 1.
  3. Ing komputer host, navigasi menyang "Instrumen Nasional" LabVIEW »eksamples»instr»niUSRP.
  4. Bukak niUSRP EX Tx Continuous Async example VI lan mbukak.
    Yen piranti ngirim sinyal, grafik I/Q nampilake gelombang I lan Q.
  5. Bukak niUSRP EX Rx Continuous Async example VI lan mbukak.
    Yen piranti ngirim sinyal, grafik I/Q nampilake gelombang I lan Q.

Ngatasi masalah

Yen masalah tetep sawise sampeyan ngrampungake prosedur ngatasi masalah, hubungi dhukungan teknis NI utawa bukak ni.com/support.
Ngatasi masalah piranti
Napa piranti ora urip?
Priksa sumber daya kanthi ngganti adaptor sing beda.
Napa USRP2 Muncul tinimbang Piranti USRP ing Utilitas Konfigurasi NI-USRP?

  • Alamat IP sing salah ing komputer bisa nyebabake kesalahan iki. Priksa alamat IP lan bukak maneh Utilitas Konfigurasi NI-USRP.
  • Gambar FPGA utawa perangkat kukuh lawas ing piranti uga bisa nyebabake kesalahan iki. Nganyarke FPGA lan perangkat kukuh nggunakake Utilitas Konfigurasi NI-USRP.

Apa Aku Nganyari Firmware Piranti lan Gambar FPGA?
Piranti USRP dikirim nganggo firmware lan gambar FPGA sing kompatibel karo piranti lunak driver NI-USRP. Sampeyan bisa uga kudu nganyari piranti kanggo kompatibilitas karo versi paling anyar saka piranti lunak.
Nalika sampeyan nggunakake API NI-USRP, FPGA gawan mbukak saka panyimpenan terus-terusan ing piranti.
Media piranti lunak driver uga kalebu Utilitas Konfigurasi NI-USRP, sing bisa digunakake kanggo nganyari piranti.

Nganyari Firmware Piranti lan Gambar FPGA (Opsional)
Firmware lan gambar FPGA kanggo piranti USRP disimpen ing memori internal piranti.
Sampeyan bisa ngisi maneh gambar FPGA utawa gambar perangkat kukuh nggunakake Utility Konfigurasi NI-USRP lan sambungan Ethernet, nanging sampeyan ora bisa nggawe gambar FPGA adat nggunakake sambungan Ethernet.

  1. Yen sampeyan durung rampung, sambungake komputer host menyang piranti nggunakake port Ethernet.
  2. Pilih Start»All Programs»National Instruments»NI-USRP»NI-USRP Configuration Utility kanggo mbukak NI-USRP Configuration Utility.
  3. Pilih tab N2xx/NI-29xx Image Updater. Utilitas kanthi otomatis ngisi kolom Gambar Firmware lan Gambar FPGA kanthi path menyang perangkat kukuh standar lan gambar FPGA files. Yen sampeyan pengin nggunakake beda files, klik tombol Telusuri ing jejere file sampeyan pengin ngganti, lan navigasi menyang file sampeyan pengin nggunakake.
  4. Priksa manawa firmware lan path gambar FPGA wis diketik kanthi bener.
  5. Klik tombol Refresh Dhaptar Piranti kanggo mindhai piranti USRP lan nganyari dhaptar piranti.
    Yen piranti ora katon ing dhaptar, priksa manawa piranti urip lan wis nyambung kanthi bener menyang komputer.
    Yen piranti sampeyan isih ora katon ing dhaptar, sampeyan bisa nambah piranti kanthi manual menyang dhaptar. Klik tombol Tambah Piranti kanthi manual, ketik alamat IP piranti ing kothak dialog sing ditampilake, banjur klik OK.
  6. Pilih piranti sing arep dianyari saka dhaptar piranti lan verifikasi yen sampeyan milih piranti sing bener.
  7. Verifikasi yen versi gambar FPGA file cocog karo revisi papan kanggo piranti sing lagi dianyari.
  8. Kanggo nganyari piranti, klik tombol TULIS GAMBAR.
  9. Kothak dialog konfirmasi ditampilake. Konfirmasi pilihan sampeyan lan klik OK kanggo nerusake.
    Bar kemajuan nuduhake status nganyari.
  10. Nalika nganyari rampung, kothak dialog njaluk sampeyan ngreset piranti. Reset piranti ngetrapake gambar anyar menyang piranti. Klik OK kanggo ngreset piranti.
    AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Utilitas ora responsif nalika verifikasi manawa piranti kasebut wis direset kanthi bener.
  11. Nutup sarana.

Informasi sing gegandhengan
Deleng bagean Muat Gambar menyang Lampu kilat On-board (Mung Seri USRP-N) saka Cathetan Aplikasi UHD - USRP2 lan N Series
Napa Piranti USRP Ora Katon ing MAX?
MAX ora ndhukung piranti USRP. Gunakake Utilitas Konfigurasi NI-USRP.
Bukak Utilitas Konfigurasi NI-USRP saka menu Mulai ing Mulai»Kabeh Program» Instrumen Nasional»NI-USRP»Utilitas Konfigurasi NI-USRP.

Napa Piranti USRP Ora Katon ing Utilitas Konfigurasi NI-USRP?

  1. Priksa sambungan antarane piranti USRP lan komputer.
  2. Priksa manawa piranti USRP disambungake menyang komputer nganggo adaptor Ethernet sing kompatibel karo gigabit.
  3. Priksa manawa alamat IP statis 192.168.10.1 diwenehake menyang adaptor ing komputer sampeyan.
  4. Ngidini nganti 15 detik nganti piranti bisa diwiwiti kanthi lengkap.
    Apa ora NI-USRP Examples Katon ing NI Example Finder ing LabVIEW?
    NI-USRP ora nginstal examples menyang NI Examplan Finder.

Informasi sing gegandhengan
NI-USRP Eksamples lan Piwulang ing kaca 9
Ngatasi Masalah Jaringan
Napa Piranti Ora Nanggapi Ping (Panjaluk Echo ICMP)?
Piranti kasebut kudu mangsuli panyuwunan gema protokol pesen kontrol internet (ICMP).
Rampungake langkah-langkah ing ngisor iki kanggo ping piranti lan nampa respon.

  1. Kanggo ping piranti, bukak command prompt Windows lan ketik ping 192.168.10.2, ing ngendi 192.168.10.2 minangka alamat IP kanggo piranti USRP sampeyan.
  2. Yen sampeyan ora nampa respon, verifikasi yen kertu antarmuka jaringan host disetel menyang alamat IP statis sing cocog karo subnet sing padha karo alamat IP piranti sing cocog.
  3. Priksa manawa alamat IP piranti wis disetel kanthi bener.
  4. Baleni langkah 1.

Informasi sing gegandhengan
Ngganti Alamat IP ing kaca 6
Napa Utilitas Konfigurasi NI-USRP Ora Ngasilake Listing kanggo Pirantiku?
Yen Utilitas Konfigurasi NI-USRP ora ngasilake dhaptar kanggo piranti sampeyan, goleki alamat IP tartamtu.

  1. Navigasi menyang Files>\Instrumen Nasional\NI-USRP\.
  2. -klik-tengen folder utilities, banjur pilih Bukak jendhela printah kene saka menu trabasan kanggo mbukak command prompt Windows.
  3. Ketik uhd_find_devices –args=addr= 192.168.10.2 ing command prompt, ing ngendi 192.168.10.2 minangka alamat IP kanggo piranti USRP sampeyan.
  4. Pencet .
    Yen printah uhd_find_devices ora ngasilake dhaptar kanggo piranti sampeyan, firewall bisa uga mblokir balesan menyang paket siaran UDP. Windows nginstal lan ngaktifake firewall kanthi gawan. Kanggo ngidini komunikasi UDP karo piranti, mateni piranti lunak firewall sing ana gandhengane karo antarmuka jaringan kanggo piranti kasebut.

Napa Alamat IP Piranti Ora Reset menyang Default?
Yen sampeyan ora bisa ngreset alamat IP piranti gawan, piranti sampeyan bisa uga ana ing subnet sing beda karo adaptor jaringan host. Sampeyan bisa nggawe siklus daya piranti ing gambar sing aman (mung diwaca), sing nyetel piranti menyang alamat IP standar  192.168.10.2.

  1. Bukak tutup piranti, priksa manawa sampeyan nindakake pancegahan statis sing cocog.
  2. Goleki tombol safe-mode, saklar tombol push (S2), ing njero enclosure.
  3. Pencet terus tombol mode aman nalika sampeyan nguripake piranti.
  4. Terus pencet tombol mode aman nganti LED panel ngarep kedhip lan tetep padhet.
  5.  Nalika ing mode aman, mbukak Utilitas Konfigurasi NI-USRP kanggo ngganti alamat IP saka standar, 192.168.10.2, dadi nilai anyar.
  6. Siklus daya piranti tanpa nyekel tombol mode aman kanggo bali menyang mode normal.
    AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan NI nyaranake sampeyan nggunakake jaringan darmabakti tanpa piranti USRP liyane disambungake menyang komputer inang kanggo nyegah kamungkinan saka konflik alamat IP. Uga, priksa manawa alamat IP statis adaptor jaringan host ing komputer sing nganggo Utilitas Konfigurasi NI-USRP beda karo alamat IP standar piranti 192.168.10.2 lan beda karo alamat IP anyar sing pengin disetel piranti.
    AEG DVK6980HB 90cm Chimney Cooker Hood - lambang 2Cathetan Yen alamat IP piranti ana ing subnet sing beda karo adaptor jaringan inang, sistem inang lan sarana konfigurasi ora bisa komunikasi lan ngatur piranti kasebut. Kanggo example, sarana ngenali, nanging ora bisa ngatur piranti karo alamat IP 192.168.11.2 disambungake menyang adaptor jaringan inang karo alamat IP statis saka 192.168.10.1 lan topeng subnet saka 255.255.255.0. Kanggo komunikasi karo lan ngatur piranti, ganti adaptor jaringan host menyang alamat IP statis ing subnet sing padha karo piranti, kayata 192.168.11.1, utawa ngganti subnet mask adaptor jaringan host kanggo ngenali alamat IP sing luwih akeh, kayata 255.255.0.0.

Informasi sing gegandhengan
Ngganti Alamat IP ing kaca 6
Napa Piranti Ora Nyambung menyang Antarmuka Host?
Antarmuka Ethernet host kudu antarmuka Ethernet gigabit kanggo nyambung menyang piranti USRP.
Priksa manawa sambungan antarane kertu antarmuka jaringan host lan sambungan kabel piranti bener lan piranti lan komputer diuripake.
A LED ijo surem ing sudhut kiwa ndhuwur port sambungan Ethernet gigabit ing panel ngarep piranti nuduhake sambungan Ethernet gigabit.

Panel ngarep lan konektor

Sambungan langsung menyang Piranti
Piranti USRP minangka instrumen RF presisi sing sensitif marang ESD lan transien. Priksa manawa sampeyan nindakake pancegahan ing ngisor iki nalika nggawe sambungan langsung menyang piranti USRP supaya ora ngrusak piranti kasebut.
Stiebel Eltron CON 5 Premium Wall dipasang convector heater - cathetanKabar Gunakake sinyal eksternal mung nalika piranti USRP diuripake.
Nerapake sinyal eksternal nalika piranti dipateni bisa nyebabake karusakan.

  • Priksa manawa sampeyan wis grounded kanthi bener nalika manipulasi kabel utawa antena sing disambungake menyang konektor TX 1 RX 1 utawa RX 2 piranti USRP.
  • Yen sampeyan nggunakake piranti sing ora diisolasi, kayata antena RF sing ora diisolasi, priksa manawa piranti kasebut dijaga ing lingkungan sing bebas statis.
  • Yen sampeyan nggunakake piranti aktif, kayata preamplifier utawa ngalih routed menyang piranti USRP TX 1 RX 1 utawa konektor RX 2, mesthekake yen piranti ora bisa generate transients sinyal luwih saka specifications RF lan DC piranti USRP TX 1 RX 1 utawa RX 2 konektor.

USRP-2920 Panel ngarep lan LED

INSTRUMEN NATIONAL USRP Software Defined Radio Piranti - LED

Tabel 5. Katrangan Konektor

Konektor Katrangan
RX aku TX aku Input lan output terminal kanggo sinyal RF. RX aku TX aku SMA (f) konektor karo impedansi 50 12 lan saluran input utawa output siji-rampung.
RX 2 Terminal input kanggo sinyal RF. RX 2 punika SMA (f) konektor karo impedansi 50 CI lan saluran input siji-rampung.
REF ING Terminal input kanggo sinyal referensi eksternal kanggo osilator lokal (LO) ing piranti. REF IN minangka SMA (konektor 0 kanthi impedansi 50 CI lan minangka input referensi tunggal. REF IN nampa sinyal 10 MHz kanthi daya input minimal 0 dBm
(.632 Vpk-pk) lan daya input maksimum 15 dBm (3.56 Vpk-pk) kanggo gelombang persegi utawa gelombang sinus.
PPS ing Terminal input kanggo referensi wektu pulsa per detik (PPS). PPS IN punika SMA (t) konektor karo impedansi 50 12 lan input siji-rampung. PPS IN nampa 0 V kanggo 3.3 V TTL lan 0 V kanggo 5 V sinyal TTL.
MIMO EXPANSION Port antarmuka MIMO EXPANSION nyambungake rong piranti USRP nggunakake kabel MIMO sing kompatibel.
GB ETHERNET Port Ethernet gigabit nampa konektor RJ-45 lan kabel sing kompatibel karo gigabit Ethernet (Kategori 5, Kategori 5e, utawa Kategori 6).
DAYA Input daya nampa konektor daya DC 6 V, 3 A eksternal.

Tabel 6. Indikator LED

LED Katrangan warna Indikasi
A Nuduhake status ngirim piranti. Mati Piranti kasebut ora ngirim data.
Ijo Piranti kasebut ngirim data.
B Nuduhake status sambungan kabel MIMO fisik. Mati Piranti kasebut ora disambungake nggunakake kabel MIMO.
Ijo Piranti kasebut disambungake nggunakake kabel MIMO.
C Nuduhake status nampa piranti. Mati Piranti ora nampa data.
Ijo Piranti kasebut nampa data.
D Nuduhake status perangkat kukuh piranti. Mati Firmware ora dimuat.
Ijo Firmware dimuat.
E Nuduhake status kunci referensi LO ing piranti. Mati Ora ana sinyal referensi, utawa LO ora dikunci kanggo sinyal referensi.
Kedhip-kedhip LO ora dikunci kanggo sinyal referensi.
Ijo LO dikunci kanggo sinyal referensi.
F Nuduhake status daya piranti. Mati Piranti dipateni.
Ijo Piranti diuripake.

USRP-2921 Panel ngarep lan LED

INSTRUMEN NATIONAL USRP Software Defined Radio Device - Panel

Tabel 7. Katrangan Konektor

Konektor Katrangan
RX I
TX aku
Input lan output terminal kanggo sinyal RF. RX aku TX aku SMA (f) konektor karo impedansi 50 12 lan saluran input utawa output siji-rampung.
RX 2 Terminal input kanggo sinyal RF. RX 2 punika SMA (f) konektor karo impedansi 50 fl lan saluran input siji-rampung.
REF ING Terminal input kanggo sinyal referensi eksternal kanggo osilator lokal (LO) ing piranti. REF IN minangka konektor SMA (f) kanthi impedansi 50 SI lan minangka input referensi siji-rampung. REF IN nampa sinyal 10 MHz karo daya input minimal 0 dBm (.632 Vpk-pk) lan daya input maksimum IS dBm (3.56 Vpk-pk) kanggo gelombang persegi utawa gelombang sinus.
PPS ing Terminal input kanggo referensi wektu pulsa per detik (PPS). PPS IN punika SMA (f) konektor karo impedansi 50 12 lan input siji-rampung. PPS IN nampa sinyal 0 V nganti 3.3 V TTL lan 0 V nganti 5 V TEL.
MIMO EXPANSION Port antarmuka MIMO EXPANSION nyambungake rong piranti USRP nggunakake kabel MIMO sing kompatibel.
GB ETHERNET Port Ethernet gigabit nampa konektor RJ-45 lan kabel sing kompatibel karo gigabit Ethernet (Kategori 5, Kategori 5e, utawa Kategori 6).
DAYA Input daya nampa konektor daya DC 6 V, 3 A eksternal.

Tabel 8. Indikator LED

LED Katrangan warna Indikasi
A Nuduhake status ngirim piranti. Mati Piranti kasebut ora ngirim data.
Ijo Piranti kasebut ngirim data.
B Nuduhake status sambungan kabel MIMO fisik. Mati Piranti kasebut ora disambungake nggunakake kabel MIMO.
Ijo Piranti kasebut disambungake nggunakake kabel MIMO.
C Nuduhake status nampa piranti. Mati Piranti ora nampa data.
Ijo Piranti kasebut nampa data.
D Nuduhake status perangkat kukuh piranti. Mati Firmware ora dimuat.
Ijo Firmware dimuat.
E Nuduhake status kunci referensi LO ing piranti. Mati Ora ana sinyal referensi, utawa LO ora dikunci kanggo sinyal referensi.
Kedhip-kedhip LO ora dikunci kanggo sinyal referensi.
Ijo LO dikunci kanggo sinyal referensi.
F Nuduhake status daya piranti. Mati Piranti dipateni.
Ijo Piranti diuripake.

USRP-2922 Panel ngarep lan LEDINSTRUMEN NATIONAL USRP Software Defined Radio Piranti - Ngarep

Tabel 9. Katrangan Konektor

Konektor Katrangan
RX I
TX1
Input lan output terminal kanggo sinyal RF. RX aku TX aku SMA (f) konektor karo impedansi 50 12 lan saluran input utawa output siji-rampung.
RX 2 Terminal input kanggo sinyal RF. RX 2 punika SMA (f) konektor karo impedansi 50 ci lan saluran input siji-rampung.
RE: F ING Terminal input kanggo sinyal referensi eksternal kanggo osilator lokal (LO) ing piranti. REF IN punika SMA (f) konektor karo impedansi 50 D lan input referensi siji-rampung. REF IN nampa sinyal 10 MHz karo daya input minimal 0 dBm (.632 Vpk-pk) lan daya input maksimum 15 dBm (3.56 Vpk-pk) kanggo gelombang persegi utawa gelombang sinus.
PPS ing Terminal input kanggo referensi wektu pulsa per detik (PPS). PPS IN minangka konektor SMA (f) kanthi impedansi 50 CI lan minangka input tunggal. PPS IN nampa 0 V kanggo 3.3 V TTL lan 0 V kanggo 5 V sinyal TTL.
MIMO EXPANSION Port antarmuka MIMO EXPANSION nyambungake rong piranti USRP nggunakake kabel MIMO sing kompatibel.
GB ETHERNET Port Ethernet gigabit nampa konektor RJ-45 lan kabel sing kompatibel karo gigabit Ethernet (Kategori 5, Kategori 5e, utawa Kategori 6).
DAYA Input daya nampa konektor daya DC 6 V, 3 A eksternal.

Tabel 10. Indikator LED

LED Katrangan warna indikasi
A Nuduhake status ngirim piranti. Mati Piranti kasebut ora ngirim data.
Ijo Piranti kasebut ngirim data.
B Nuduhake status sambungan kabel MIMO fisik. Mati Piranti kasebut ora disambungake nggunakake kabel MIMO.
Ijo Piranti kasebut disambungake nggunakake kabel MIMO.
C Nuduhake status nampa piranti. Mati Piranti ora nampa data.
Ijo Piranti kasebut nampa data.
D Nuduhake status perangkat kukuh piranti. Mati Firmware ora dimuat.
Ijo Firmware dimuat.
E Nuduhake status kunci referensi LO ing piranti. Mati Ora ana sinyal referensi, utawa LO ora dikunci kanggo sinyal referensi.
Kedhip-kedhip LO ora dikunci kanggo sinyal referensi.
Ijo LO dikunci kanggo sinyal referensi.
F Nuduhake status daya piranti. Mati Piranti dipateni.
Ijo Piranti diuripake.

Where to Go Sabanjure

Deleng tokoh ing ngisor iki kanggo informasi babagan tugas produk liyane lan sumber daya sing ana gandhengane kanggo tugas kasebut.

INSTRUMEN NASIONAL NI 9421 8-Channel Sinking Digital Input Module - ikon 1 Dokumentasi & Sumber Daya Seri C
ni.com/info seridoc
INSTRUMEN NASIONAL NI 9421 8-Channel Sinking Digital Input Module - ikon 2 Layanan
ni.com/services

INSTRUMEN NASIONAL NI-9265 4 Saluran 0mA nganti 20mA Modul Output Analog 16-Bit - ikon 1Dumunung ing ni.com/manuals
INSTRUMEN NASIONAL NI-9265 4 Saluran 0mA nganti 20mA Modul Output Analog 16-Bit - ikon 2Nginstal karo piranti lunak

Dhukungan lan Layanan ing saindenging jagad

Instrumen Nasional websitus punika sumber lengkap kanggo technical support. Ing ni.com/support, sampeyan duwe akses menyang kabeh saka ngatasi masalah lan pangembangan aplikasi sumber daya kanggo bantuan email lan telpon saka NI Application Engineers.
Dolan maring ni.com/services kanggo Layanan Instalasi Pabrik NI, ndandani, garansi lengkap, lan layanan liyane.
Dolan maring ni.com/register kanggo ndhaptar produk Instrumen Nasional sampeyan. Registrasi Product nggampangake technical support lan njamin sing nampa nganyari informasi penting saka NI.
Pranyatan Kesesuaian (DoC) minangka pratelan kepatuhan kita karo Dewan Komunitas Eropa nggunakake deklarasi kesesuaian pabrikan. Sistem iki menehi perlindungan pangguna kanggo kompatibilitas elektromagnetik (EMC) lan safety produk. Sampeyan bisa entuk DoC kanggo produk sampeyan kanthi ngunjungi ni.com/sertifikasi. Yen produk sampeyan ndhukung kalibrasi, sampeyan bisa entuk sertifikat kalibrasi kanggo produk sampeyan ing ni.com/calibration.

Kantor pusat perusahaan National Instruments dumunung ing 11500 North Mopac Expressway, Austin, Texas, 78759-3504.
National Instruments uga duwe kantor ing saindenging jagad.
Kanggo dhukungan telpon ing Amerika Serikat, nggawe panjalukan layanan ing ni.com/support utawa nelpon 1 866 ASK MYNI (275 6964).
Kanggo dhukungan telpon ing njaba Amerika Serikat, bukak bagean Worldwide Offices ni.com/niglobal kanggo ngakses kantor cabang websitus, sing nyedhiyakake informasi kontak sing paling anyar, nomer telpon dhukungan, alamat email, lan acara saiki.

Deleng NI Trademarks lan Logo Guidelines ing ni.com/trademarks kanggo informasi babagan merek dagang National Instruments. Jeneng produk lan perusahaan liyane sing kasebut ing kene minangka merek dagang utawa jeneng dagang saka perusahaan kasebut. Kanggo paten sing nyakup produk/teknologi Instrumen Nasional, deleng lokasi sing cocog: Bantuan»Paten ing piranti lunak sampeyan, patents.txt file ing media sampeyan, utawa Notifikasi Paten Instrumen Nasional ing
ni.com/patents. Sampeyan bisa nemokake informasi babagan perjanjian lisensi pangguna pungkasan (EULA) lan kabar hukum pihak katelu ing readme file kanggo produk NI Panjenengan. Waca Informasi Kepatuhan Ekspor ing ni.com/legal/export-compliance  kanggo kabijakan kepatuhan perdagangan global Instrumen Nasional lan carane njupuk kode HTS, ECCN, lan data impor/ekspor liyane sing cocog. NI ora ana JAMINAN EXPRESS UTAWA diwenehake kanggo akurasi informasi sing ana ing kene lan ora bakal tanggung jawab kanggo kesalahan. Pelanggan Pemerintah AS: Data sing ana ing manual iki dikembangake kanthi biaya pribadi lan tundhuk karo hak winates lan hak data sing diwatesi kaya sing kasebut ing FAR 52.227-14, DFAR 252.227-7014, lan DFAR 252.227-7015.
© 2005—2015 Instrumen Nasional. Kabeh hak dilindhungi undhang-undhang.

Dokumen / Sumber Daya

INSTRUMEN NATIONAL USRP Software Defined Radio Piranti [pdf] Pandhuan pangguna
USRP-2920, USRP-2921, USRP-2922, Piranti Radio sing Ditetepake Perangkat Lunak USRP, USRP, Piranti, Piranti sing Ditemtokake, Piranti Radio, Piranti Radio sing Ditemtokake, Piranti Radio sing Ditetepake USRP, Piranti Radio sing Ditemtokake Piranti Lunak

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *