TRACEABLE CC653X Temperature Bluetooth Data Logger Mga Tagubilin

TRACEABLE logo

DATALOGGER INSTRUCTIONS

Icon ng Babala 54 MAHALAGANG PAUNAWA

You MUST download one of the Mobile Apps below to retrieve data and configure device

TRACEABLEGO App


Bluetooth LANG


Download TraceableGO™ App


TraceableLIVE


Bluetooth + Cloud Data Storage


TraceableLIVE® Subscription REQUIRED


NOW that one of the apps below have been installed on your mobile device

TraceableGO comes ready to use out of the box.

TRACEABLEGO App

TraceableGO™ App Free Download

LIBRE

Mga tampok

TRACEABLE - A1 Configure datalogger:
  • Itakda ang Alarm
  • Change Logging Interval
  • Mag-toggle sa pagitan ng °C/°F
  • Start/Stop Options
  • Balot ng Memorya
TRACEABLE - A1 Export, Email and Save PDF to Mobile Device
TRACEABLE - A2 UNLIMITED CLOUD DATA STORAGE
TRACEABLE - A2 Data download to CSV, or Secured PDF
TRACEABLE - A2 Graphical UI to analyze data
TRACEABLE - A2 Summary data display: Min/Max, Kinetic Mean, Time in Alarm
TRACEABLE - A2 Storage of trip parameters
TRACEABLE - A2 21 CFR 11 Compliance
TraceableLIVE

TraceableLIVE® App Libreng Download

$30/buwan

Mga tampok

TRACEABLE - A1 Configure datalogger:
  • Itakda ang Alarm
  • Change Logging Interval
  • Mag-toggle sa pagitan ng °C/°F
  • Start/Stop Options
  • Balot ng Memorya
TRACEABLE - A1 Export, Email and Save PDF to Mobile Device
TRACEABLE - A1 UNLIMITED CLOUD DATA STORAGE
TRACEABLE - A1 Data download to CSV, or Secured PDF
TRACEABLE - A1 Graphical UI to analyze data
TRACEABLE - A1 Summary data display: Min/Max, Kinetic Mean, Time in Alarm
TRACEABLE - A1 Storage of trip parameters
TRACEABLE - A1 21 CFR 11 Compliance
I-configure ang DEVICE

TANDAAN: To configure device either TraceableGO™ or TraceableLIVE® Apps must be downloaded to a mobile device.

ENABLE BLUETOOTH
  1. Quick press twice START/STOP to enable Bluetooth, and Bluetooth LCD symbol appears.
  2. Device starts to advertise to be found, and to be connected. Device Name shown on TraceableGO™ App discovered list looks like CC653X-xxxx, where “CC653X” indicates model number and “-xxxx” is last 4 digits of device serial number.
  3. If no connection has been made for ISANG MINUTO, Bluetooth will be disabled to save battery life, and Bluetooth LCD symbol Bluetooth 1a disappears, or quick press twice again to disable Bluetooth.
SA VIEW PRE-CONFIGURED SETTINGS

1. Enable Bluetooth on device (see above).

2. Open TraceableGO™ or TraceableLIVE® App on any bluetooth enabled mobile device.
Tandaan: Mobile device must have Bluetooth enabled to receive signal. To enable Bluetooth on a mobile device see mobile device settings.

3. Use TraceableGO™ or TraceableLIVE® App to connect to device. Once the app is open it will begin searching for devices to connect to.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 1

A list of available Dataloggers will appear.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 2

Tandaan: TraceableGO Bluetooth Dataloggers are serialized and each logger name will match the sticker located on the side of the unit.

4. Once device is selected select Configure.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 3

5. The following parameters are configured through App: START Mode, STOP Mode, ALARM Enable/Disable, Celsius/Fahrenheit, Memory Mode, Data Logging Interval, Alarm Setting.

6. TraceableGO™ comes pre-programmed. To view current settings, tap on configure once device is selected in App.

7. Device comes pre-configured as shown below:

TRACEABLE CC653X Temperature Bluetooth Data Logger - 4

a. Pangalan ng Device
b. Serial Number ng Device
c. Current Battery Status
d. Current Temperature and/or Humidity Readings

PRE-CONFIGURED DEVICE SETTINGS

  1. START Mode: Push Start
  2. STOP Mode: Push Button Stop
  3. Memory Mode: Wrap when Memory is Full
  4. Unit Preferences: °C
  5. Alarm Setting Alarm Low:
    TAP ON VALUE TO CHANGE
    ▪ Temperature: 2°C (6535 only)
    ▪ Temperature: 20°C (6537 only)
    ▪ Humidity: 25% RH (6537 only)
  6. Alarm Setting High Alarm:
    TAP ON VALUE TO CHANGE
    ▪ Temperature: 8°C (6535 only)
    ▪ Temperature: 30°C (6537 only)
    ▪ Humidity: 75% RH (6537 only)
  7. Alarm Enable/Disable: Enabled
  8. Data Logging Interval: 5 minutes
  9. Date/Time is also set to current to central time (Automatically updates when connected to mobile device).
Tap Configure to change factory settings

1. START Mode
Agarang Pagsisimula: Once device is configured it will begin Datalogging.
Push Button: Press START/STOP Button to begin Datalogging.
Naantala: Select number of Hours, Minutes and Seconds when device is to begin Datalogging.

2. STOP Mode
hindi kailanman: Device will never stop Datalogging.
Push Button: Pindutin MAGSIMULA/HINGILAN Button to Stop Datalogging.

3. Mode ng Memorya
Wrap When Full: Once memory is full, oldest data points will be overwritten with new data points.
Stop When Full: Device will stop recording when Memory is Full 64K (65,536) data points, 7.5 months on 5-minute logging interval.

4. Unit Preferences
° F: Select Fahrenheit
°C: Select Celsius

5. Alarm Setting Alarm Low: TAP ON VALUE TO CHANGE

  • Temperatura: Set LOWEST Temperature before an alarm is triggered.
  • Humidity (6537 only): Set LOWEST Relative Humidity before an alarm is triggered.

6. Alarm Setting High Alarm: TAP ON VALUE TO CHANGE

  • Temperatura: Set HIGHEST Temperature before an alarm is triggered.
  • Humidity (6537 only): Set HIGHEST Relative Humidity value before an alarm is triggered.

7. Alarm Enable/Disable
Pinagana: Ang alarm ay nasa.
Hindi pinagana: Naka-off ang alarm.

8. Data Logging Interval
Slide to desired Logging Interval.

9. Save Configurations: Sine-save ang kasalukuyang mga setting.
TANDAAN: Saving a Configuration will delete all data on device.

Once device has been configured, device enters STANDBY Mode.

Date/Time is also set to current to central time (Automatically updates when connected to mobile aparato).

TRACEABLE CC653X Temperature Bluetooth Data Logger - 5

TRACEABLE CC653X Temperature Bluetooth Data Logger - 6

HOW TO DOWNLOAD DATA TO MOBILE DEVICE

TANDAAN: To download data either TraceableGO™ or TraceableLIVE Apps must be downloaded to a mobile device.

ENABLE BLUETOOTH
  1. Quick press twice START/STOP to enable Bluetooth, and Bluetooth LCD symbol appears.
  2. Device starts to advertise to be found, and to be connected. Device Name shown on TraceableGO™ App discovered list looks like CC653X-xxxx, where “CC653X” indicates model number and “-xxxx” is last 4 digits of device serial number.
  3. If no connection has been made for ISANG MINUTO, Bluetooth will be disabled to save battery life, and Bluetooth LCD symbol Bluetooth 1a disappears, or quick press twice again to disable Bluetooth.
TO DOWNLOAD RECORDED DATA

1. Device must be stopped. Enable Bluetooth on device (see above).

2. Open TraceableGO™ or TraceableLIVE® App on any bluetooth enabled mobile device. Tandaan: Mobile device must have Bluetooth enabled to receive signal. To enable Bluetooth on a mobile device see mobile device settings.

3. Use TraceableGO™ or TraceableLIVE® App to connect to device. Once the app is open it will begin searching for devices to connect to.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 7

A list of available Dataloggers will appear.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 8

Tandaan: TraceableGO™ Bluetooth Dataloggers are serialized and each logger name will match the sticker located on the side of the unit.

4. Once device is selected select Download Data.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 9

5. App will begin extracting the data from TraceableGO™ Device.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 10

6. Once data download is complete, mobile device will display options how to send PDF file, or CSV file (TraceableLIVE only). Tap Done and download is complete.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 11

MGA ESPISIPIKASYON

TRACEABLE CC653X Temperature Bluetooth Data Logger - 12

Pusa Bilang 6535

TRACEABLE CC653X Temperature Bluetooth Data Logger - 13

Pusa Bilang 6538

TRACEABLE CC653X Temperature Bluetooth Data Logger - 14

Pusa Bilang 6537

TEMPERATURA

6535: Ambient Range: -20.0 hanggang 70.0°C (-4.0 hanggang 158.0°F)
6536/6538 Probe Range: -50.0 hanggang 70.0°C (-58.0 hanggang 158.0°F)
6539 Probe Range: -90.00 hanggang 100.00°C (-130.00 hanggang 212.00°F)
Resolusyon: 0.1°C
Katumpakan:
6535: ±0.4°C between -10 and 70°C, otherwise ±0.5°C
6536/6538: ±0.3°C
6539: ±0.2°C

RELATIVE HUMIDITY & TEMPERATURE

Temperatura—
Ambient Range: –20.0 hanggang 70.0 ° C (–4.0 hanggang 158.0 ° F)
Resolusyon: 0.1°C
Katumpakan: ±0.4°C between –10 and 70°C, otherwise ±0.5°C

Relative Humidity—
Ambient Range: 0% to 95%RH, non-condensing
Resolusyon: 0.1% RH
Katumpakan: ±3% RH between 5 to 75%, otherwise ±5% RH

EXTERNAL PROBE

6536 Bullet Probe: Standard plastic probe sensor with cable. Designed for use in air and liquids, the sensor and cable may be completely immersed. Probe size: 3/16” diameter, 4/5” length; 10 foot cable

6538 Bottle Probe: Designed to simulate the temperature of stored liquids, use in transportation coolers, refrigerators and freezers. Bottle probes are filled with a patented nontoxic glycol solution that is GRAS (Generally Recognized As Safe) by the FDA (Food and Drug Administration) eliminating concerns about incidental contact with food or drinking water. The included micro-thin probe cable permits refrigerator/freezer doors to close on it. (Do not immerse bottle probes in liquid). Probe size: 1 x 2-1/2 inches; 10 foot cable.

6539 Stainless-Steel/Platinum Probe: Detachable stainless steel 316 Probe with Platinum Sensor and 9 feet of cable are supplied with the unit. Probe has a diameter of 1/8-inch, stem length of 6-1/4 inches, overall length of 9 inches.

Baterya: 2 AAA Alkaline batteries (3.0V)

dimensyon: L x H x D: 3.5 x 2 x 0.79” (89 x 51 x 20 mm)

Indikasyon ng Antas ng Baterya:

Antas ng baterya LCD symbol
≥ 80% (2.78V) TRACEABLE CC653X Temperature Bluetooth Data Logger - 15
≥ 60% (2.56V), < 80% TRACEABLE CC653X Temperature Bluetooth Data Logger - 16
≥ 40% (2.34V), < 60% TRACEABLE CC653X Temperature Bluetooth Data Logger - 17
≥ 20% (2.12V), < 40% TRACEABLE CC653X Temperature Bluetooth Data Logger - 18
≥ 10% (2.01V), < 20% TRACEABLE CC653X Temperature Bluetooth Data Logger - 19
< 10% Flashing TRACEABLE CC653X Temperature Bluetooth Data Logger - 20

Tandaan: Battery level is updated every 5 minutes.

Tandaan: Once battery level drops to below 10%, device may not work properly. Replace batteries immediately.

Tandaan: When replacing batteries, after removing the old batteries, wait 10 seconds before inserting new batteries. Otherwise, Bluetooth may not work properly.

MEASUREMENT READING UPDATE FREQUENCY

Temperature and Humidity: 5 seconds;

Tandaan: If a reading is out of operating range, corresponding location on LCD will display ‘–.-‘, and such out of range reading will not trigger alarm.

DATA LOGGING FREQUENCY:

5 min by default, user-adjustable between 1 minute and 12 hours with 1 minute step.

DATA STORAGE CAPACITY

Alarm: Most recent 90 Alarm events

Data: 64K (65536) data points, 7.5 months on 5-minute logging interval

DEVICE OPERATING MODES

  • IDLE Mode: First time battery inserted, and device has not been configured
  • STANDBY Mode: Device has been configured, but not started;
  • RUN Mode: Device starts to measure and log data.
  • STOP Mode: Device stops from RUN Mode. In STOP Mode, device does not update measurements or log data, and the last measurements are displayed.

VIEW KASALUKUYANG PAGBASA

  1. Temperature ONLY unit: Current reading, minimum/maximum reading, run time/alarm time toggling, Memory mode are shown on LCD.
  2. Humidity and Temperature unit: Current temperature/humidity reading toggling every 5 seconds, minimum/maximum reading since last clearing, run time/alarm time, Memory mode are shown on LCD.

VIEW CURRENT MIN/MAX

Temperature ONLY unit: Current temperature Min/Max values are displayed on LCD. Humidity and Temperature unit: Current temperature/humidity Min/Max values are toggled display.

Tandaan: Every time device is configured, or resumes to run from STOP Mode, Min/Max values are reset.

VIEWING RUN TIME/ALARM TIME

Run Time/Alarm Time is toggled to display on LCD. If Run Time is displayed, LCD symbol PANAHON NG PAGTAKBO appears; if Alarm Time is displayed, LCD symbol ORAS NG ALARM lilitaw.

Tandaan: Alarm Time is accumulated for both Low Alarm and Hi Alarm for each channel (temperature, humidity).

MEMORY

If Memory Mode is set to WRAP WHEN FULL, TRACEABLE CC653X Temperature Bluetooth Data Logger - 21 appears on LCD; If Memory Mode is set to STOP WHEN FULL, MEM lumalabas sa LCD.

ALARM

  1. Once an alarm is triggered by any of temperature, humidity out of set alarm range, LCD symbol LOW ALM at/o HI ALM starts to flash. An Alarm Event will be logged.
  2. Pagpindot MAGSIMULA/HINGILAN once will clear alarm, LCD symbol stops flashing. An Alarm Acknowledge Event will be logged.
  3. If temperature, or humidity falls back to normal range, an Alarm Event will be logged. If any of temperature, humidity measurement goes back to out of alarm range, alarm will be triggered again.
  4. If device’s START Mode is configured as PUSH BUTTON TO START (default), device LCD displays ‘push to start’. Press and hold MAGSIMULA/HINGILAN until LCD symbol appears. Device enters RUN Mode. If device’s START Mode is configured as IMMEDIATE START, device enters RUN Mode immediately. If device’s START Mode is configured as DELAYED TIME START, delayed start time set by user is counting down on device LCD. Once the counting time reaches 0, device enters RUN Mode.
  5. Kung nasa RUN Mode, LCD symbol TAKBO appears, and logs data at user-defined interval. If STOP Mode is configured as PUSH BUTTON TO STOP, press and hold MAGSIMULA/HINGILAN until LCD symbol TUMIGIL appears. Device enters STOP Mode. If STOP Mode is configured as NEVER STOP, device will ignore button press, and will stop when memory is full if Memory Mode is set to STOP WHEN FULL, or will stop when TraceableGO™ App is connected to device and downloads the data.
  6. If in STOP Mode, press and hold MAGSIMULA/HINGILAN until LCD symbol TAKBO appears. Device enters RUN Mode and resumes to log data at current setting. Anytime device resumes to log data from STOP Mode, Min/Max values are reset.

Tandaan: If device in STOP Mode, START Mode will be set to PUSH BUTTON TO START regardless of previous Start Mode Setting. If Delayed Start Mode is needed while device in STOP Mode, device must be re-configured.

Tandaan: While device is connected to TraceableGO™ App, once Device has received command from App to upload data to App, device will stop logging data and enter STOP Mode if it is still in RUN mode.

VIEW MEMORY USAGE, CURRENT DATE/TIME, DEVICE’S SERIAL NUMBER

1. Pindutin at bitawan MAGSIMULA/HINGILAN pindutan

2. Memory usage in percentage is shown on LCD. The percentage indicates how much internal data memory storage has been used;

3. Number of days, hours, minutes left till memory is full are also displayed on the second line;

TRACEABLE CC653X Temperature Bluetooth Data Logger - 22

4. Sa loob ng 10 segundo, pindutin ang MAGSIMULA/HINGILAN again, current date/time is displayed on device LCD. The following figure shows 9/14/2017, 17:30

TRACEABLE CC653X Temperature Bluetooth Data Logger - 23

5. Sa loob ng 10 segundo, pindutin ang MAGSIMULA/HINGILAN again, device S/N will be displayed on LCD.

TRACEABLE CC653X Temperature Bluetooth Data Logger - 24

6. To return to normal working status, press MAGSIMULA/HINGILAN again, or wait for 10 seconds and device will automatically go back to normal working status.

Tandaan: If Memory Mode is set to WRAP WHEN FULL: LCD symbol TRACEABLE CC653X Temperature Bluetooth Data Logger - 21 starts to flash on the display when the memory is full. Once memory is full, the oldest data points will be overwritten with new data points.

If Memory Mode is set to STOP WHEN FULL: LCD symbol MEM starts to flash on the display when the memory is 95% full. Once memory is full, the device will stop logging new data points.

CLEAR DATA MEMORY STORAGE

  1. Data points stored in device internal storage can only be cleared through App or battery removal.
  2. Each time device is configured, all stored data points will be cleared.
  3. Run Time/Alarm Time are also reset.

IMPORMASYON SA REGULATORY

Ang kagamitang ito ay nasubok at natagpuang sumusunod sa mga limitasyon para sa isang Class B na digital na device, alinsunod sa Bahagi 15 ng Mga Panuntunan ng FCC. Ang mga limitasyong ito ay idinisenyo upang magbigay ng makatwirang proteksyon laban sa mapaminsalang interference sa isang residential installation. Ang kagamitang ito ay bumubuo, gumagamit at maaaring magpalabas ng enerhiya ng dalas ng radyo at, kung hindi naka-install at ginamit alinsunod sa mga tagubilin, ay maaaring magdulot ng nakakapinsalang interference sa mga komunikasyon sa radyo.

Gayunpaman, walang garantiya na hindi magaganap ang interference sa isang partikular na pag-install. Kung ang kagamitang ito ay nagdudulot ng mapaminsalang interference sa pagtanggap ng radyo o telebisyon, na maaaring matukoy sa pamamagitan ng pag-off at pag-on ng kagamitan, hinihikayat ang user na subukang itama ang interference sa pamamagitan ng isa o higit pa sa mga sumusunod na hakbang:

  • I-reorient o i-relocate ang receiving antenna.
  • Palakihin ang paghihiwalay sa pagitan ng kagamitan at receiver.
  • Ikonekta ang kagamitan sa isang saksakan sa isang circuit na iba sa kung saan nakakonekta ang receiver.
  • Kumonsulta sa dealer o isang may karanasang radio/TV technician para sa tulong.

Sumusunod ang device na ito sa Part 15 ng FCC Rules. Ang operasyon ay napapailalim sa sumusunod na dalawang kundisyon: (1) ang device na ito ay maaaring hindi magdulot ng mapaminsalang interference, at (2) ang device na ito ay dapat tumanggap ng anumang interference na natanggap, kabilang ang interference na maaaring magdulot ng hindi gustong operasyon.

Hereby, Traceable Products, declares that this digital thermometer is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

Sumusunod ang device na ito sa (mga) pamantayan ng RSS na walang lisensya ng Industry Canada. Ang pagpapatakbo ay napapailalim sa sumusunod na dalawang kundisyon: (1) ang device na ito ay maaaring hindi magdulot ng interference, at (2) ang device na ito ay dapat tumanggap ng anumang interference, kabilang ang interference na maaaring magdulot ng hindi gustong paggana ng device.

TANDAAN: ANG GRANTEE AY HINDI RESPONSABLE PARA SA ANUMANG PAGBABAGO O PAGBABAGO NA HINDI HAYAG NA APPROBADO NG PARTY NA RESPONSABLE PARA SA PAGSUNOD. ANG GANITONG MGA PAGBABAGO AY MAAARING MAGBAWAS NG AWTORIDAD NG GUMAGAMIT NA MAG-OPHERE NG EQUIPMENT.

WARRANTY, SERBISYO, O RECALIBRATION

Para sa warranty, serbisyo, o muling pagkakalibrate, makipag-ugnayan sa:

TRACEABLE® PRODUCTS
12554 Old Galveston Rd. Suite B230 • Webster, Texas 77598 USA
Ph. 281 482-1714 • Fax 281 482-9448
E-mail support@traceable.comwww.traceable.com

Traceable® Products are ISO 9001:2015 Quality-Certified by DNV and ISO/IEC 17025:2017 accredited as a Calibration Laboratory by A2LA.

App Store 11 Google play 22

TraceableLIVE® and TraceableGO™ are registered trademark/trademarks of Cole-Parmer.

©2020 Traceable® Products. 92-6535-20  Rev. 3 080725

Mga Dokumento / Mga Mapagkukunan

TRACEABLE CC653X Temperature Bluetooth Data Logger [pdf] Mga tagubilin
CC653X, CC653X Temperature Bluetooth Data Logger, Temperature Bluetooth Data Logger, Bluetooth Data Logger, Data Logger

Mga sanggunian

Mag-iwan ng komento

Ang iyong email address ay hindi maipa-publish. Ang mga kinakailangang field ay minarkahan *