EKE 110 1V Injection Controller
“
Spesifikasi Teknis
- Pasokan Voltage: 24 V AC/DC* 50/60 Hz, SELV **
- Input Serep Baterei: Danfoss nyaranake EKE 2U
- Jumlah Output Katup: 1
- Tipe Katup: Modbus RS485 RTU
- Baud Rate (setelan gawan): Ora kasebut
- Mode (setelan gawan): Ora ditemtokake
- Jumlah Sensor Suhu: Ora ditemtokake
- Jinis Sensor Suhu: Ora ditemtokake
- Jumlah Sensor Tekanan: Ora ditemtokake
- Jinis Pemancar Tekanan: Ora ditemtokake
- Jumlah Input Digital: Ora ditemtokake
- Panganggone Input Digital: Ora ditemtokake
- Output Digital: Ora ditemtokake
- PC Suite: Ora ditemtokake
- Alat Layanan: Ora ditemtokake
- Pemasangan: Ora ditemtokake
- Suhu panyimpenan: Ora ditemtokake
- Suhu operasi: Ora ditemtokake
- Kelembapan: Ora ditemtokake
- Enclosure: Ora ditemtokake
- Tampilan: Ora ditemtokake
Pandhuan panggunaan produk:
Panduan Instalasi:
Tindakake pandhuan instalasi sing kasedhiya ing manual pangguna kanggo
Tipe Kontroler Injeksi EKE 110 1V (PV01).
Aplikasi Dasar - Mode Injeksi Cairan (LI):
Ing mode iki, tindakake urutan nglibatno Condenser, Valve A,
DGT, Injection Valve, Economizer, Expansion Valve, lan Evaporator
miturut instruksi.
Mode Injeksi Basah lan Uap (VI/WI):
Ing mode iki, tindakake urutan nglibatno Condenser, Valve A,
TP, DGT, Injection Valve, PeA, S2A, Expansion Valve, lan Evaporator
miturut pandhuan kanggo hulu lan hilir
konfigurasi.
Pitakonan sing Sering Ditakoni (FAQ):
P: Apa sing disaranake pasokan voltage kanggo produk?
A: Sumber sing disaranake voltage iku 24 V AC / DC * 50/60 Hz, SELV
**.
P: Pira output katup produk kasebut?
A: Produk duwe 1 katup output.
P: Apa produk ndhukung Modbus RS485 RTU
komunikasi?
A: Ya, produk ndhukung komunikasi Modbus RS485 RTU kanggo
kontrol katup.
“`
080R0416 080R0416
Pandhuan instalasi
Tipe Pengontrol Injeksi EKE 110 1V (PV01)
Pambuka Pengontrol injeksi EKE 110 1V bisa digunakake kanggo: Uap utawa mode injeksi udan (VI / WI): Ngendi controller bakal ngatur katup motor stepper ing injeksi uap superheated menyang port injeksi kompresor lan kanthi otomatis ngalih menyang injeksi udan supaya suhu gas discharge dhuwur kontrol (DGT) gumantung ing kahanan mlaku. Iki mbisakake kinerja kompresor apik ing amplop mlaku lengkap. Mode Injeksi Cairan (LI): Ing endi pengontrol bakal ngatur katup motor stepper ing injeksi cair kanggo nyegah kontrol suhu gas (DGT) sing dhuwur banget gumantung saka kahanan sing mlaku. Iki mbisakake kompresor kanggo mbukak aman ing amplop mlaku lengkap. Kontroler iki biasane digunakake ing aplikasi pompa panas sekitar komersial, komersial lan industri. Katup sing kompatibel: ETS 6 / ETS 5M Bipolar / ETS 8M Bipolar / ETS Colibri / ETS 175-500L / CCMT L / CCMT / CCM / CTR
Aplikasi dhasar Mode injeksi Cairan (LI):
Kondensor
Katup A
DGT
Katup injeksi
DGT
: ” ” 04080, 80, / 168, Economizer Economizer
Info kanggo pelanggan UK mung: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB
Katup ekspansi
Evaporator
Mode injeksi Basah lan Uap (VI/WI): Hulu
Kondensor
Katup A
TP
DGT
DGT
Katup injeksi
PeA
S2A
Katup ekspansi
Evaporator
Ngisor
Kondensor
Katup A
TP
DGT
DGT
Injeksi
katup
PeA
S2A
Katup ekspansi
Evaporator
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 1
Spesifikasi teknis
Pasokan Voltage
24 V AC/DC* 50/60 Hz, SELV **
Input serep baterei (Danfoss nyaranake EKE 2U) Jumlah output katup Tipe katup Modbus RS485 RTU Baud rate (setelan standar) Mode (setelan standar) Jumlah sensor suhu Tipe sensor suhu Jumlah Sensor tekanan Tipe pemancar tekanan*** Jumlah input digital Gunakake input digital****
Output digital*****
PC Suite Service tool Mounting Suhu panyimpenan Suhu operasi Kelembapan Enclosure Tampilan
24V DC
1 katup motor stepper Katup stepper bipolar Ya (Terpencil) 19200 8E1 2(S2A, DGT) S2A-PT1000/NTC10K, DGT-PT1000 1 (PeA) Ratometrik 0-5-5 V DC, 0-10V, Arus 4-20mA (DI1) Regulasi wiwitan/Stop 1 output: D1 (kolektor terbuka), arus sink maks 0 mA Koolprog EKA 10 + kabel servis EKE 200 100mm Rel Din -35 30 °C / -80 22 °F -176 20 °C / -70 4 °F <158% RH, non- kondensasi IP90 No
Cathetan: * Unit kasebut cocog kanggo digunakake ing sirkuit sing bisa ngirim simetris ora luwih saka 50A RMS. Amperes ** Kanggo AS lan Kanada, nggunakake kelas 2 sumber daya *** Tekanan pemancar output sumber voltage nganti 18V / 50mA **** Yen ora nggunakake DI kanggo fungsi wiwitan mandeg banjur fisik short terminal karo COM. ***** Kanthi gawan, DO diatur kanggo komunikasi weker kanggo kompresor mandeg. Bisa digunakake kanggo weker liyane yen
diaktifake ing konfigurasi.
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 2
Sambungan Liwatview EKE 110
Port -/~ lan +/~
Deskripsi Power Supply
Bumi Fungsional
+ 5 V / 18 V + 5 V / 18 V Ext-GND GND DO PeA S2A DI1* DGT
Katup BAT- lan BAT+ A MODBUS (B-, A+, GND)
Voltage kanggo probe tekanan** Ora digunakake Ora digunakake Ground / Comm kanggo sinyal I/O Output Digital Sinyal tekanan kanggo economizer.
Cathetan: * DI minangka piranti lunak sing bisa dikonfigurasi, yen ora digunakake karo sinyal eksternal, banjur dadi korsleting utawa konfigurasi minangka ora digunakake ing piranti lunak.
** Kanthi gawan sumber daya kanggo meksa pemancar disetel kanggo 0V. Pasokan bakal ganti dadi 5V yen pemancar tekanan
dipilih minangka ratiometric lan 18V yen dipilih minangka jinis saiki. Pasokan bisa diganti kanthi manual kanthi milih ing parameter
P014 ing konfigurasi I / O majeng
Cathetan:
Kanggo ngindhari potensial malfungsi utawa karusakan ing EKE 110, sambungake kabeh komponen periferal mung menyang sing wis ditemtokake.
bandar-bandar. Nyambungake komponen menyang port sing ora ditemtokake bisa nyebabake masalah operasional.
ukuran
70 mm
110 mm
© Danfoss | solusi iklim | 2024.10
Dhuwur: 49 mm
AN500837700728en-000102 | 3
Mounting/Demounting Unit bisa dipasang ing 35 mm rel DIN mung dening snapping menyang panggonan lan ngamanake karo stopper kanggo nyegah ngusapake. Dibuwang kanthi alon-alon narik stirrup sing ana ing dhasar omah.
Pemasangan :
1 2
Demounting:
Langkah 1:
"Klik" 3
Langkah 2:
Copot konektor lanang sing ditampilake ing ndhuwur
Narik stirrup nggunakake screwdriver lan copot EKE saka ril
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 4
Instalasi Modbus
· Kanggo kabel Modbus, iku paling apik kanggo nggunakake 24 AWG shielded kabel twisted-pair karo kapasitansi shunt 16 pF / ft lan 100 impedansi.
· Kontroler nyedhiyakake antarmuka komunikasi RS485 terisolasi sing disambungake menyang terminal RS485 (ndeleng sambungan liwatview).
· Maks. nomer idin piranti bebarengan disambungake kanggo output kabel RS485 punika 32. · Kabel RS485 saka impedansi 120 karo dawa maksimum 1000 m. · Terminal resistor 120 kanggo piranti terminal dianjurake ing loro ends. Frekuensi komunikasi EKE (baud rate) bisa dadi salah siji saka ing ngisor iki: 9600, 19200 utawa 38400
baud, standar 19200 8E1. · Alamat unit standar yaiku 1. · Kanggo informasi rinci babagan Modbus PNU, priksa manual EKE 110
A + B-
Ora digunakake
Danfoss 93Z9023
GND
Manual ngreset alamat Modbus: 1. Priksa manawa setelan pemancar tekanan disetel menyang pemancar jinis ratiometric ing konfigurasi 2. Copot daya Supply saka EKE 110 3. Sambungake terminal BAT + menyang +5 V / 18 V (Penting kanggo mesthekake langkah 1 diamati) 4 . Sambungake EKE 110 menyang daya 5. Saiki opsi komunikasi Modbus direset menyang standar pabrik (Alamat 1, 19200 baud, mode 8E1)
Nuduhake sinyal
Nuduhake sumber daya lan serep · 1 EKE 110 lan 1 EKE 2U bisa nuduhake sumber daya (AC utawa DC) · 2 EKE 110 lan 1 EKE 2U mung bisa nuduhake sumber daya karo DC
Enggo bareng pemancar tekanan · Enggo bareng fisik ora diidini. · Enggo bareng Modbus diijini karo luwih saka 1 controller.
Nuduhake sensor suhu · Enggo bareng fisik ora diidini. · Enggo bareng Modbus diijini karo luwih saka 1 controller.
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 5
Kabel
Konektor katup stepper
A1 A2 B1 B2 Ora nyambung
ETS/KVS/CCM/ CCMT/CTR/ CCMT L (Nggunakake Kabel Danfoss M12)
Putih Ireng Abang Ijo
–
ETS 8M Bipolar ETS 6
Kuning oranye
Abang Ireng
–
Kuning Orange
Abang Ireng Grey
· Kabeh klep sing mimpin ing mode bipolar karo 24 V sumber disigar kanggo ngontrol saiki (Sopir saiki).
· Motor stepper disambungake menyang terminal "Stepper Valve" (ndeleng tugas terminal) nganggo kabel sambungan M12 standar.
· Kanggo ngatur katup motor stepper liyane saka katup motor stepper Danfoss, paramèter katup sing bener kudu disetel kaya sing diterangake ing bagean konfigurasi Valve kanthi milih katup sing ditetepake pangguna.
Sumber daya lan Baterei input Analog Sensor
Katup stepper
Input digital Output digital
Panjang kabel Maks 5m Maks 10m Maks 10m Maks 30m Maks 10m Maks 10m
Ukuran kawat min/maks (mm2)
AWG 24-12 (0.34-2.5 mm ) Torsi (0.5-0.56 Nm)
AWG 24-16 (0.14-1.5 mm)
AWG 24-16 (0.14-1.5 mm)
AWG 24-16 (0.14-1.5 mm ) Torsi (0.22-0.25 Nm)
AWG 24-16 (0.14-1.5 mm)
AWG 24-16 (0.14-1.5 mm)
· Maks. jarak kabel antarane controller lan tutup gumantung ing akeh faktor kaya shielded / kabel unshielded, ukuran kabel digunakake ing kabel, daya output kanggo controller lan EMC.
· Tetep kabel pengontrol lan sensor dipisahake saka kabel listrik. · Sambungake kabel sensor luwih saka dawa sing ditemtokake bisa nyuda akurasi
nilai sing diukur. · Pisah sensor lan kabel input digital sabisa (paling ora 10cm) saka
kabel daya menyang beban kanggo ngindhari gangguan elektromagnetik. Aja nyelehake kabel listrik lan kabel probe ing saluran sing padha (kalebu ing panel listrik)
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 6
Weker LED lan Warning
2 Sec
Indikasi LED Alarm/Warning
1 Sec
0 Sec
Daya r -/AC +/AC PE
1111111111111111
0000000000000000 1111000011110000 0101010101010101
daya
Ora Ana Weker / Warning A Alarm / Warning A 5 Sec wiwitan boot
Posisi katup kanthi indikasi LED
Operasi katup normal
2 Sec
1 Sec
0 Sec
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Katup ditutup 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 2 Tutup katup 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Katup idle ing target
B2 B1 A2 A1 Katup lan A
B2 B1 A2 A1 Katup lan B
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 Katup idle ing target 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 5 Bukaan katup 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Katup mbukak
Katup mbukak sirkuit utawa katup driver masalah panas
01 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1010101010101010
Tipe katup ora ditetepake
1010101010101010 1010101010101010
Fitur umum lan bebaya
Fitur omah plastik · Pemasangan rel DIN sing tundhuk karo EN 60715 · V0 mateni mandhiri miturut IEC 60695-11-10 lan tes kabel mencorong/panas ing 960 °C miturut
kanggo IEC 60695-2-12
Fitur liyane · Digabungake ing piranti Kelas I lan/utawa II · Indeks proteksi: IP00 utawa IP20 ing produk, gumantung saka nomer dodolan · Periode tegangan listrik ing bagean insulasi: dawa – Cocog kanggo nggunakake ing polusi normal
lingkungan · Kategori resistance kanggo panas lan geni: D · Kakebalan marang voltage lonjakan: kategori II · Kelas lan struktur piranti lunak: kelas A
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 7
Kepatuhan CE · Kondisi operasi CE: -20T70, 90% RH non-kondensasi · Kondisi panyimpenan: -30T80, 90% RH non-kondensasi · Vol rendahtagpedoman e: 2014/35/EU · Kompatibilitas elektromagnetik EMC: 2014/30/EU lan karo norma ing ngisor iki: · EN61000-6-1, (Standar kekebalan kanggo lingkungan omah, komersial, lan industri cahya) · EN61000-6- 2, (Standar kekebalan kanggo lingkungan industri) · EN61000-6-4, (standar emisi kanggo lingkungan industri) · EN60730 (Kontrol listrik otomatis kanggo omah lan panggunaan sing padha)
Bebaya umum · Saben panggunaan sing ora diterangake ing manual iki dianggep salah lan ora sah dening
pabrikan · Priksa manawa kahanan instalasi lan operasi piranti ngurmati sing kasebut ing
manual, utamané bab sumber voltage lan kahanan lingkungan · Mulane kabeh operasi layanan lan pangopènan kudu dileksanakake dening personel qualified · Piranti kasebut ora bisa digunakake minangka piranti safety · Tanggung jawab kanggo ciloko utawa karusakan sing disebabake nggunakake piranti sing salah mung ana ing pangguna.
Bebaya instalasi · Posisi pemasangan sing disaranake: vertikal · Instalasi kudu tundhuk karo standar lan peraturan lokal · Sadurunge nggarap sambungan listrik, copot piranti saka sumber daya utama · Sadurunge nindakake operasi pangopènan piranti, copot kabeh sambungan listrik.
sambungan – Kanggo alasan safety, piranti kudu dipasang ing panel listrik sing ora bisa diakses bagean urip · Aja nyedhiyakake piranti kanggo nyemprotake banyu sing terus-terusan utawa kelembapan relatif luwih saka 90%. · Ngindhari paparan gas korosif utawa polutan, unsur alam, lingkungan sing ana bahan peledak utawa campuran gas sing gampang kobong, bledug, geter utawa kejut sing kuat, fluktuasi gedhe lan cepet ing suhu lingkungan sing bisa nyebabake kondensasi kanthi kombinasi kelembapan sing dhuwur, magnetik sing kuat lan /utawa gangguan radio (contone, ngirim antena) · Gunakake ujung kabel sing cocog kanggo konektor sing cocog. Sawise ngencengi sekrup konektor, tarik kabel alon-alon kanggo mriksa kenceng - Nyilikake dawa probe lan kabel input digital sabisa, lan supaya rute spiral watara piranti daya. Kapisah saka beban induktif lan kabel daya kanggo ngindhari gangguan elektromagnetik - Aja ndemek utawa meh ndemek komponen elektronik ing papan supaya ora ana muatan elektrostatik · Gunakake kabel komunikasi data sing cocog. Deleng lembar data EKE kanggo jinis kabel sing bakal digunakake lan rekomendasi persiyapan · Nyilikake dawa probe lan kabel input digital sabisa-bisa lan ngindhari rute spiral ing sakubenge piranti daya. Kapisah saka beban induktif lan kabel daya kanggo ngindhari swara elektromagnetik sing bisa ditindakake.
Bebaya produk · Gunakake catu daya kelas II. · Nyambungake input EKE menyang voltage bakal ngrusak controller permanen. · Terminal Serep Baterei ora ngasilake daya kanggo ngisi daya piranti sing disambungake. · Baterei serep – voltage bakal nutup katup motor stepper yen controller ilang sumber
voltage. · Aja nyambungake sumber daya eksternal menyang input digital terminal DI supaya ora ngrusak
pengontrol.
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 8
Danfoss Related produk Powersupply
Sensor suhu
Transduser tekanan
AK-PS LANGKAH 3
Input ACCTRD: 230 V AC, 50 60 Hz Output: 24 V AC, kasedhiya karo 12 VA, 22 VA lan 35 VA
PT 1000 AKS minangka suhu presisi dhuwur. sensor AKS 11 (preferred), AKS 12, AKS 21 ACCPBT PT1000
Sensor NTC EKS 221 ( NTC-10 Kohm) MBT 153 ACCPBT NTC Temp probe (IP 67/68)
DST / AKS Pressure Tranducer Kasedhiya karo ratiometric lan 4 20 mA.
NSK Ratometrik tekanan probe
XSK Pressure probe 4 20 mA
Katup motor stepper
M12 Kab
Modul daya serep
EKE kompatibel karo katup motor stepper Danfoss yaiku Danfoss ETS 6, ETS, KVS, ETS Colibri®, KVS colibri®, CTR, CCMT, ETS 8M, CCMT L, ETS L
Kabel M12 Angle kanggo nyambungake Danfoss stepper motor katup lan EKE controller
EKA 200 Koolkey
Kabel servis EKE 100
Piranti panyimpenan energi EKE 2U kanggo mateni katup darurat sajrone dayatage.
EKA 200 digunakake minangka layanan / tombol salinan kanggo EKE 100 controller
Kabel servis EKE 100 digunakake kanggo nyambungake pengontrol EKE 100 / 110 menyang EKA 200 Koolkey
© Danfoss | solusi iklim | 2024.10
AN500837700728en-000102 | 9
Dokumen / Sumber Daya
![]() |
Danfoss EKE 110 1V Injection Controller [pdf] Pandhuan Instalasi EKE 110 1V Pengontrol Injeksi, EKE 110 1V, Pengontrol Injeksi, Pengontrol |