Resistex Miks LED Downlight Installation and Safety Guide

Resistex Miks LED Downlight

Version: V1.1 - 09.22

Company Information

Resistex Exploitation
11 Quai de la Banquière CS 80010, 06730 Saint-André-de-la-Roche - France
Tel: 04 93 276 276 - Fax: 04 93 276 280
Email: contact@resistex-sa.com
APE 2740Z - Siret 487 593 477 00010 - SAS CAPITAL 649979 € - VAT FR 73 487 593 477

Website: www.resistex-sa.com

Installation Instructions (EN)

Safety Notes

  • Never work when voltage is present on the luminaire.
  • The installation must be performed by a professional installer in compliance with the standards and regulations relating to electrical installations.
  • ⚠️ Risk of electrostatic discharges. (ESD Norm). Handle with precautions.
  • Please observe the notes and steps described in the mounting instructions.

Maintenance Instructions

  • Do not use chemicals or abrasives products to clean the fixture.
  • Keep these instructions for dismantling or future maintenance. You can consult additional information about RESISTEX luminaires on the website www.resistex-sa.com.
  • RESISTEX cannot be responsible for any misuse of the product.

Mounting / Installation Steps

The following steps detail the installation process for the Miks downlight.

  1. Step 1: Preparation

    Shows a circular template with dimensions Ø69mm (+/-1mm) for ceiling cut-out.

    [Ceiling cut-out template with Ø69mm (+/-1mm) dimension]
  2. Step 2: Positioning

    Illustrates the downlight fixture being positioned above a ceiling opening, with its spring-loaded mounting clips retracted or ready to be engaged.

    [Fixture positioned above ceiling opening, clips ready]
  3. Step 3: Securing Fixture

    Depicts the fixture being pushed into the ceiling opening, causing the spring clips to expand and secure the fixture.

    [Fixture pushed into opening, clips expanding]
  4. Step 4: Electrical Connection Preparation

    A close-up view of the electrical connector, showing how to insert the power wires (Live, Neutral) into the designated terminals. Arrows indicate the direction of insertion.

    [Close-up of connector, wires being inserted into terminals]
  5. Step 5: Locking Wires

    Shows the electrical connector with wires inserted, and a lever mechanism that is closed to secure the wires.

    [Connector with wires, lever being closed]
  6. Step 6: Terminal Identification

    The electrical connector terminals are clearly labeled 'L' (Live), 'N' (Neutral), and a ground terminal.

    [Connector terminals labeled L, N, Ground]
  7. Step 7: Connecting Power

    Illustrates the process of connecting the Live and Neutral wires to their respective terminals within the connector.

    [Connecting Live and Neutral wires to terminals]
  8. Step 8: Final Insertion

    Shows the downlight fixture being compressed and inserted into the prepared ceiling opening, with the spring clips ready to hold it in place.

    [Fixture compressed and inserted into ceiling opening]
  9. Step 9: Wire Termination Check

    The fixture is now installed, with the spring clips fully engaged against the ceiling. Two diagrams show correct wire termination (green checkmark ✔️) and incorrect termination (red cross ❌), indicating proper stripping of insulation.

    [Fixture installed, clips engaged. Correct (✔️) vs Incorrect (❌) wire termination shown.]
  10. Step 10: Installation Complete

    A final view of the installed Miks downlight in the ceiling, with an indication of an ON/OFF switch.

    [Installed Miks downlight in ceiling with ON/OFF indicator]

Product Certifications and Features

  • [RoHS compliant]
  • [Class II]
  • [IP65 rated]
  • [IK07 rated]
  • [CRI 82]
  • [5 Year Warranty]
  • [CE Marked]
Models: 926lm CCT B.LUM RD-RD, 963257_NOT1, 963257 Miks LED Downlight, 963257, Miks LED Downlight, LED Downlight, Downlight

File Info : application/pdf, 2 Pages, 676.99KB

PDF preview unavailable. Download the PDF instead.

963257 NOT1

References

GPL Ghostscript 9.53.3

Related Documents

Preview Resistex Miks LED Downlight Installation Guide
Step-by-step installation instructions for the Resistex Miks LED downlight, including safety precautions, mounting procedures, and maintenance advice.
Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation instructions for the Resistex Miks LED downlight, detailing safety precautions, step-by-step mounting procedures, and maintenance advice. Includes technical specifications and company contact information.
Preview Resistex Miks Downlight: Installation, Safety, and Maintenance Guide
Comprehensive guide for installing the Resistex Miks downlight, including safety and maintenance information. Learn how to properly install this adjustable, low-luminance lighting fixture, ensuring compliance with electrical standards.
Preview Resistex Miks Lighting Fixture Installation Guide
Comprehensive installation instructions for the Resistex Miks lighting fixture, covering safety precautions, maintenance, and step-by-step assembly with diagrams explained.
Preview Resistex Miks LED Downlight: Installation Guide and Safety Instructions
Detailed installation guide for the Resistex Miks LED downlight, covering safety precautions, maintenance, and step-by-step mounting instructions. Includes technical specifications and certifications.
Preview Resistex Miks LED Luminaire Installation Guide
Official installation instructions for the Resistex Miks LED luminaire. Includes safety notes, mounting steps, and technical specifications. Features adjustable orientation and low light options.
Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation guide for the Resistex Miks LED downlight, covering safety precautions, mounting instructions, and maintenance. Features adjustable orientation and low luminance options.
Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation guide for the Resistex Miks LED downlight, featuring safety instructions, maintenance advice, and step-by-step mounting procedures. Includes product specifications and certifications.