Resistex Miks LED Downlight
Installation and Safety Guide
Product Overview
This document provides installation, safety, and maintenance instructions for the Resistex Miks LED downlight.
Model: Miks
Version: V1.1 - 09.22
Installation Instructions
Follow these steps for proper installation:
Step 1: Prepare Ceiling Opening
Cut a circular opening in the ceiling with a diameter of 69mm (+/- 1mm). Ensure the cut-out is precise.
Diagram Description: Shows a template for cutting a circle of Ø69mm and the resulting hole in a ceiling panel.
Step 2: Insert Fixture
Place the LED downlight fixture into the prepared ceiling opening.
Diagram Description: Shows the downlight fixture being pushed upwards into the ceiling hole.
Step 3: Secure Fixture
Rotate the fixture to engage the mounting clips and secure it in place. The diagram shows a rotational movement to lock the fixture.
Diagram Description: Illustrates rotating the fixture to lock it into the ceiling.
Step 4: Prepare Wiring
Open the electrical connector housing. The diagram shows a lever mechanism to open the connector.
Diagram Description: Shows the connector being opened, ready for wire insertion.
Step 5: Connect Wires
Insert the electrical wires (Live, Neutral, Ground) into the appropriate terminals within the connector. Ensure secure connections.
Diagram Description: Shows wires being inserted into a push-in connector block, with labels L, N, and Ground (symbolized by earth icon).
Step 6: Close Connector
Close the electrical connector housing to secure the wire connections.
Diagram Description: Shows the connector being closed after wires are inserted.
Step 7: Final Check
Verify all connections are secure and the fixture is properly seated in the ceiling.
Diagram Description: Shows a checkmark indicating correct installation and a cross indicating incorrect installation, likely related to wiring or seating.
Step 8: Final Installation
The fixture is now installed in the ceiling.
Diagram Description: Shows the completed installation of the downlight in a ceiling.
Options / Accessories
Adjustable Orientation
Instructions for adjusting the orientation of the light. The diagrams show how to orient the fixture.
Diagram Description: Shows three steps illustrating how to adjust the angle or orientation of the downlight.
Low Luminance / Low Light
Instructions related to low luminance or low light settings, possibly for different modes or versions of the fixture.
Diagram Description: Shows three steps related to the low luminance feature, possibly involving different components or settings.
Safety Notes
- Never work on the luminaire when it is live (under voltage).
- Installation must be performed by a professional installer in compliance with relevant electrical standards and regulations.
- Be aware of the risk of electrostatic discharges (ESD Norm). Handle with necessary precautions.
- Please observe the notes and steps described in the mounting instructions.
Maintenance Instructions
- Do not use chemicals or abrasive products to clean the fixture.
- Keep these instructions for dismantling or future maintenance.
- Additional information about RESISTEX luminaires is available on the website www.resistex-sa.com.
- RESISTEX cannot be held responsible for any misuse of the product.
Company Information
RESISTEX EXPLOITATION
11 Quai de la Banquière CS 80010, 06730 Saint-André-de-la-Roche - France
Tel: 04 93 276 276
Fax: 04 93 276 280
Email: contact@resistex-sa.com
Website: www.resistex-sa.com
APE 2740Z - Siret 487 593 477 00010 - SAS CAPITAL 649979 € - T.V.A. F.R. 73 487 593 477
Certifications and Ratings
The fixture complies with various standards and regulations:
- IP65: Dust and water protection.
- IK07: Impact resistance.
- Class II: Electrical safety classification.
- CE: European Conformity.
- ROHS: Restriction of Hazardous Substances.
- IRC: Warranty period (likely 5 years, indicated by '5').