Resistex Miks LED Downlight
Installation Guide
General Information
- Model: Miks
- Manufacturer: Resistex
- Document Version: V1.1 - 09.22
Safety Notes
- ⚠️ Never work when voltage is present on the luminaire.
- The installation must be performed by a professional installer in compliance with electrical installation standards and regulations.
- Handle with care to prevent electrostatic discharges (ESD Norm).
- Please observe the notes and steps described in the mounting instructions.
Maintenance Instructions
- Do not use chemicals or abrasive products to clean the fixture.
- Keep these instructions for dismantling or future maintenance.
- Additional information available on www.resistex-sa.com.
- Resistex cannot be responsible for any misuse of the product.
Mounting / Installation Steps
-
Prepare the mounting hole. For both 'Orientable / Adjustable' and 'Basse Luminance / Low Light' options, the required cutout diameter is Ø69mm (+/-1mm).
Diagram shows two types of fixtures and their respective cutout dimensions.
-
Insert the fixture body into the mounting ring or prepared opening.
Diagram shows the fixture being pushed upwards into a mounting bracket.
-
Secure the fixture by rotating it into place.
Diagram shows the fixture being turned clockwise to lock.
-
Connect the wiring. A close-up shows a connector with a clip mechanism for secure connection.
Diagram shows a connector being plugged in.
-
Open the terminal block connector to prepare for wire insertion.
Diagram shows a lever-operated terminal block being opened.
-
Insert the electrical wires into the appropriate terminals within the connector block. Ensure correct polarity.
Diagram shows wires being inserted into the terminal block.
-
Close the terminal block connector securely. The terminals are labeled L (Live) and N (Neutral).
Diagram shows the terminal block being closed, with L and N labels visible.
-
Compress the fixture's mounting springs and carefully insert the entire unit into the ceiling cutout.
Diagram shows the fixture with springs compressed, ready for insertion.
-
Release the springs to secure the fixture in the ceiling. A diagram illustrates correct wire connection (✅) and incorrect connection (❌), emphasizing polarity.
Diagram shows the fixture secured and a detail of correct/incorrect wire connections.
-
The installation is complete. The fixture is now mounted in the ceiling.
Diagram shows the finished installation with the light fixture flush in the ceiling.
Product Specifications and Certifications
- Certifications: ROHS, Classe II, IP65, IK07, CE
- Warranty: 5 Years
- Color Rendering Index (CRI): 82
- Lumen Output: 469lm
- Finish: Black reflector
Company Information
Resistex Exploitation
11 Quai de la Banquière CS 80010, 06730 Saint-André-de-la-Roche - France
Tel: 04 93 276 276 - Fax: 04 93 276 280
Email: contact@resistex-sa.com
Company Registration: APE 2740Z - Siret 487 593 477 00010 - SAS CAPITAL 649979 € - TVA F.R. 73 487 593 477
Website: www.resistex-sa.com