The Renogy ONE Core is a central monitoring and control unit for your energy system. The display shows real-time data including battery voltage (12.1V), charge percentage (78%), current (10.05A), remaining capacity (230.05Ah), battery health (76.01%), and inverter status (112.71W, 13.21V).
Quick Guide
Before Getting Started
This quick guide provides important operation and maintenance instructions for the Renogy ONE Core. Read carefully before operation and save for future reference. Failure to follow instructions may result in electrical shock, injury, or death, or damage to the device.
- Renogy ensures accuracy at the time of printing, but product improvements may occur.
- Renogy is not liable for losses due to improper installation or use.
- Renogy is not responsible for issues arising from unauthorized repairs.
- Illustrations are for demonstration; actual details may vary.
- Renogy reserves the right to change information without notice. Visit renogy.com for the latest guide.
Online Manual
Access the full Quick Guide and User Manual online.
What's In the Box?
- Renogy ONE Core × 1
- Quick Guide × 1
- M3.5*14mm Mounting Screws × 4 (1 extra)
- Power Cable (5m) × 1
Get to Know RENOGY ONE Core
Key components of the Renogy ONE Core:
- On/Off Button
- Mounting Holes
- Communication Port
- Bubble Level
- Power Port
- Type-C Port
Installation Site and Environment
Recommended installation sites for RVs (indicated by checkmarks ✔️) and unsuitable sites (indicated by crosses ❌). Ensure the device is installed vertically to the RV floor.
Environmental specifications:
- Altitude: ≤5000m
- Operating Temperature: -4°F to 158°F (-20°C to 70°C)
- Operating Humidity: 0% to 95%
- Environmental Symbols: Keep Dry [water droplet symbol], Fragile [box with glass symbol], Indoor [house symbol].
NOTE: For RV leveling function, ensure the screen points to the front, rear, left, or right side of the RV. RV leveling blocks are recommended.
Required Tools
- Phillips Screwdriver (#1)
- Insulation Tape
- Skill Saw
- Impact Drill with Hole Saw, 2.17in/55mm
NOTE: Tools are needed for flush mounting on a wall. A skill saw or electric drill with a hole saw can be used.
Step 1 (A). Place Renogy ONE Core on a Table
The package box can be used as a bracket for table placement. The RV leveling function is not available when placed on a table.
Step 1 (B). Mount Renogy ONE Core on a Wall
Mounting Template: Tear off this paper and paste it to the mounting location for drilling holes. The required hole size is 2.17in x 2.17in (55mm x 55mm).
NOTE: Another piece of paper can be used as a mounting template. The installation hole size is 2.17in x 2.17in (55mm x 55mm).
Yellow Area: Refers to the area for the mounting template.
Blue Area: Refers to the cut-out area for the device.
The mounting process involves using the template to mark and cut the wall, then attaching the device.
Steps include:
- Aligning the template.
- Cutting the hole.
- Inserting the device into the wall opening.
- Aligning and securing the mounting bracket.
- Checking the bubble level for proper orientation (indicated by ✔️ for correct, ❌ for incorrect).
- Securing the device using mounting screws.
- Connecting cables.
- Inserting the device at a 45° angle and pushing it into place until it clicks.
Step 2. Connect Renogy ONE Core to a Power Supply
Connect using the included power cable or an optional Type-C cable.
Installed on a Wall
Connect the DC Power (8-60V) using the included power cable, or connect a Type-C cable (5V, DC) to the device.
Installed on a Table
Connect the DC Power (8-60V) using the included power cable, or connect a Type-C cable (5V, DC) to the device.
NOTE: When connecting the power cable, connect the negative terminal first, then the positive terminal.
Step 3. Install a Communication Cable (Optional)
Connect an RJ45 Ethernet Cable (max length: 6m) to devices via RS-485. Refer to the User Manual for details.
Step 4. Power On/Off
Long press the On/Off Button for 5 seconds to power the Core on or off.
Step 5. Pairing with DC Home
For initial startup, follow the on-screen wizard to pair with the DC Home app. Alternatively, navigate to System > Pair with App.
Step 6. Add Devices
Renogy ONE Core supports concurrent connection to Bluetooth, Bluetooth mesh, and Zigbee Renogy devices.
The device can discover and add controllers, batteries, smart plugs, and inverters.
RV Leveling
Access RV Leveling via the menu. Calibration is required each time the installation site changes.
Important Safety Instructions
- Keep out of reach of children.
- Dispose of according to local, state, and federal laws.
- Do not expose to flammable or harsh chemicals.
- No user-serviceable parts. Do not open, dismantle, repair, or modify.
- Confirm polarities before connecting power. Reverse polarity can cause damage and void the warranty.
- Ensure DC power supply is rated 8V to 60V. Exceeding this range can cause failure or damage.
- An extended power cable can be used; refer to the User Manual.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) no harmful interference, and (2) acceptance of any interference received. Warning: Unauthorized modifications may void the user's authority to operate the equipment.
This equipment has been tested and complies with Class B digital device limits under Part 15 of FCC Rules, designed for reasonable protection against harmful interference in residential installations. If interference occurs, try measures like reorienting the antenna, increasing separation, or using a different circuit. Consult a dealer or technician if needed.
FCC Radiation Exposure Statement
Complies with FCC radiation exposure limits for uncontrolled environments. Maintain a minimum distance of 20cm between the radiator and your body.
RSS Standard
Complies with Industry Canada license-exempt RSS standard(s). Operation is subject to two conditions: (1) no interference, and (2) acceptance of any interference. Device complies with RF exposure guidelines; minimum distance from body is 20cm.
Renogy Support
For inaccuracies or omissions, visit renogy.com/support/downloads or contact contentservice@renogy.com.
For technical questions in the U.S., contact renogy.com/contact-us or call 1(909)2877111.
For technical support outside the U.S., visit local websites:
- Canada: ca.renogy.com
- United Kingdom: uk.renogy.com
- Australia: au.renogy.com
- South Korea: kr.renogy.com
- China: www.renogy.cn
- Japan: renogy.jp
- Germany: de.renogy.com
- Other Europe: eu.renogy.com
Disclaimer
© 2023 Renogy. All rights reserved. RENOGY and the Renogy logo are registered trademarks of Renogy.
Information is subject to copyright. Reproduction or copying without prior written permission is prohibited. Unauthorized use of trademarks is strictly prohibited.
Renogy Empowered
Renogy empowers people globally with DIY-friendly renewable energy solutions, promoting sustainable living and energy independence. Their solar products help minimize carbon footprints.
Live Sustainably with Renogy
A 1kW solar energy system can save:
- 170 pounds of coal from being burned per month.
- 300 pounds of CO2 from being released into the atmosphere per month.
- 105 gallons of water from being consumed per month.
Renogy Power PLUS
Join the Renogy Power Plus community to stay updated on solar innovations, share experiences, and connect with others.
Follow Renogy on social media: [YouTube icon] @Renogy Solar, [Instagram icon] @renogyofficial, [Facebook icon] @Renogy.
Manufacturer: RENOGY New Energy Co.,Ltd
Address: No.66, East Ningbo Road Room 624-625, Taicang German Overseas Students Pioneer Park, Jiangsu 215000 CN
EC REP: eVatmaster Consulting GmbH, Battinastr. 30, 60325 Frankfurt am Main, Germany, contact@evatmaster.com
UK REP: EVATOST CONSULTING LTD, Suite 11, First Floor, Moy Road Business Centre, Taffs Well, Cardiff, Wales, CF15 7QR, contact@evatmaster.com
Regulatory Information: FCC ID: 2ANPBGWSN-W02W, IC: 23590-RSHGWSNW02W
Visit: RENOGY.COM