RENOGY ONE Core
RSHGWSN-W02W-G1
Version A0
Before Getting Started
This quick guide provides important operation and maintenance instructions for the Renogy ONE Core (referred to as Core). Read the guide carefully before operation and save it for future reference. Failure to observe instructions or precautions can result in electrical shock, serious injury, or death, or damage the Core, potentially rendering it inoperable.
Renogy ensures the accuracy and sufficiency of information at the time of printing, but product improvements may occur. Renogy assumes no liability for losses caused by failure to install or use the product according to the guide. Renogy is not liable for issues arising from repairs by unqualified personnel or improper installation/operation. Illustrations are for demonstration purposes only and may vary. Renogy reserves the right to change information without notice.
Online Manuals
Access the full User Manual and Quick Guide online. [Link to Quick Guide Online Manual] [Link to User Manual Online Manual]
What's In the Box?
- Renogy ONE Core x 1
- Quick Guide x 1
- Mounting Screws (M3.5*14mm) x 4 (1 extra)
- Power Cable (5m) x 1
Get to Know RENOGY ONE Core
- Mounting Holes
- On/Off Button
- Communication Port
- Bubble Level
- Power Port
- Type-C Port
Installation Site and Environment
Diagrams illustrate acceptable installation orientations for RVs and vehicles, emphasizing 90° angles. Environmental parameters are specified: Altitude (≤5000m), Temperature (-4°F to 158°F / -20°C to 70°C), and Humidity (0% to 95%). Icons indicate conditions: Keep Dry ✔️, Fragile ⚠️, Indoor ✔️.
Note
For the RV leveling function, the screen must point to the front, rear, left, or right side of the RV, vertically to the floor. RV leveling blocks are recommended during the leveling process.
Required Tools
- Phillips Screwdriver (#1)
- Insulation Tape
- Skill Saw
- Impact Drill with Hole Saw (2.17in/55mm)
Note
Tools are required only for flush mounting on a wall. A skill saw or electric drill with a hole saw can be used.
Step 1 (A). Place Renogy ONE Core on a Table
Illustration shows the Renogy ONE Core being placed on its package box, which serves as a temporary bracket for setup when wall mounting is not required.
Note
The RV leveling function is unavailable when the Core is placed on a table.
Mounting Template
A printable mounting template is provided, measuring 2.17 inches (55mm) square, with a central circular cutout area. Instructions state: 'Please tear off this piece of paper and paste it to the mounting location for drilling holes.'
Step 1 (B). Mount Renogy ONE Core on a Wall
Note
Another piece of paper can be used as a mounting template. The installation hole size is 2.17in x 2.17in (55mm x 55mm).
Steps illustrate using the mounting template to mark drilling points on the wall, identifying a 'Yellow Area' and a 'Blue Area' on the template for precise hole placement.
Detailed steps show attaching a mounting bracket to the wall using screws, connecting necessary cables, and then aligning and snapping the Renogy ONE Core device onto the bracket at a 45° angle until it clicks securely.
Step 2. Connect Renogy ONE Core to a Power Supply
Illustrations show how to connect the Renogy ONE Core to a power source. For wall mounting, connect the included power cable to the DC Power input (8-60V) or a Battery Combiner Box. For table mounting, use the included power cable or an optional Type-C cable (5V, DC).
Note
When installing the power cable, always connect the negative terminal first, then the positive terminal.
Step 3. Install a Communication Cable (Optional)
Connect an RJ45 Ethernet cable (maximum length 6m) from the Renogy ONE Core to a HUB, which then connects to RS-485 devices for communication.
Step 4. Power On/Off
Long press the On/Off Button for approximately 5 seconds to power the Core on or off.
Step 5. Pairing with DC Home
For initial startup, follow the on-screen wizard or navigate to '> System > Pair with App' on the Core. A QR code displayed on the Core's screen is scanned by the DC Home mobile app to pair the devices.
Step 6. Add Devices
The Renogy ONE Core supports concurrent connection to Bluetooth, Bluetooth mesh, and Zigbee Renogy devices. The interface allows users to 'Add Devices', listing types such as Controllers, Batteries, Smart Plugs, Inverters, and Door Sensors. Internet connectivity is also indicated.
RV Leveling
The device interface displays the 'RV Leveling' function. Users can configure 'Installation Orientation', such as 'Screen currently facing rear'.
Note
RV leveling calibration is required each time the installation site for the Core is changed.
Important Safety Instructions
- Keep Renogy ONE Core out of the reach of children.
- Dispose of according to local, state, and federal regulations using recycling channels.
- Do not expose Renogy ONE Core to flammable or harsh chemicals or vapors.
- There are no user-serviceable parts. Do not open, dismantle, repair, or modify the device.
- Confirm polarities before connecting to a power supply; reverse polarity contact can cause damage and void the warranty.
- Ensure the connected DC power supply is rated at 8V to 60V. Exceeding this range can cause power-on failure or permanent damage.
- Extended power cables can be used; refer to the User Manual for details.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any interference received. Warning: Unauthorized modifications may void the user's authority to operate the equipment. This equipment has been tested and found to comply with Class B digital device limits, providing reasonable protection against harmful interference in residential installations. If interference occurs, users are encouraged to try measures like reorienting antennas, increasing separation, using different circuits, or consulting a technician.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits for an uncontrolled environment. Install and operate with a minimum distance of 20cm between the radiator and your body.
RSS Standard
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to two conditions: (1) it may not cause interference, and (2) it must accept any interference received. Users can obtain Canadian RF exposure and compliance information. Minimum distance from body is 20cm.
Renogy Support
For inaccuracies or omissions in this guide, visit renogy.com/support/downloads or contact contentservice@renogy.com.
For technical questions in the U.S., contact the Renogy technical support team through renogy.com/contact-us or call 1(909)2877111.
For technical support outside the U.S., visit local websites:
- Canada: ca.renogy.com
- United Kingdom: uk.renogy.com
- Australia: au.renogy.com
- South Korea: kr.renogy.com
- China: www.renogy.cn
- Japan: renogy.jp
- Germany: de.renogy.com
- Other Europe: eu.renogy.com
Disclaimer
Renogy ONE Core Quick Guide © 2023 Renogy. All rights reserved. RENOGY is a registered trademark of Renogy. Information is subject to copyright and intellectual property rights. Reproduction or modification requires prior written permission. Unauthorized use of trademarks is strictly prohibited.
Renogy Empowered
Renogy aims to empower people globally with DIY-friendly renewable energy solutions, driving sustainable living and energy independence. Their solar products help minimize carbon footprint.
Live Sustainably with Renogy
A 1kW solar energy system can save: 170 pounds of coal, 300 pounds of CO2, and 105 gallons of water per month.
Renogy Power PLUS
Renogy Power Plus allows users to stay updated on solar innovations, share experiences, and connect with the community.
Connect on YouTube @Renogy Solar, Instagram @renogyofficial, and Facebook @Renogy.
Renogy reserves the right to change manual contents without notice.
Manufacturer Information
Manufacturer: RENOGY New Energy Co., Ltd
Address: No.66, East Ningbo Road Room 624-625, Taicang German Overseas Students Pioneer Park, Jiangsu 215000 CN.
Representative Information
EC REP: eVatmaster Consulting GmbH, Battinastr. 30, 60325 Frankfurt am Main, Germany. UK REP: EVATOST CONSULTING LTD, Suite 11, First Floor, Moy Road Business Centre, Taffs Well, Cardiff, Wales, CF15 7QR.
Compliance Information
FCC ID: 2ANPBGWSN-W02W
IC: 23590-RSHGWSNW02W