RENOGY ONE Core
Model Numbers: RSHGWSN-W02W-G1 / RSHGWSN-W02W-G2
Version A2 | August 30, 2024
QUICK GUIDE
Before Getting Started
This quick guide provides essential operation and maintenance instructions for the Renogy ONE Core (referred to as Core). The Renogy ONE Core is available in two models: RSHGWSN-W02W-G1 (without CAN communication) and RSHGWSN-W02W-G2 (with CAN communication).
Read this quick guide thoroughly before operation and keep it for future reference. Failure to follow the instructions or precautions can lead to electrical shock, serious injury, or death, and may damage the Renogy ONE Core, rendering it inoperable.
Renogy ensures the accuracy, sufficiency, and applicability of information at the time of printing, subject to ongoing product improvements.
Renogy is not responsible for personal or property losses resulting from failure to install and use the product in compliance with this guide.
Renogy is not liable for failures, damages, or injuries from repairs by unqualified personnel or improper installation/operation.
Illustrations are for demonstration; actual product details may vary by revision and region.
Renogy reserves the right to change information without notice. For the latest guide, visit renogy.com.
For the full online manual, scan the QR codes provided (QR codes are not displayed here).
What's In the Box?
- Renogy ONE Core x 1
- Quick Guide x 1
- Mounting Screws x 4 (1 extra)
- Power Cable (5m) x 1
Get to Know RENOGY ONE Core
The Renogy ONE Core features:
- Mounting Holes: For securing the device.
- On/Off Button: For powering the device on/off.
- Communication Port: For connecting communication cables.
- Bubble Level: Aids in ensuring the device is mounted level.
- Power Port: For connecting the power supply.
- Type-C Port: Alternative power input.
Installation Site and Environment
Suitable Installation Locations: The device can be installed in various locations within an RV, typically mounted vertically to the RV floor. Ensure the screen is oriented towards the front, rear, left, or right side for the RV leveling function.
Environmental Conditions:
- Altitude: Up to 5000m (16404 ft)
- Temperature: -4°F to 158°F (-20°C to 70°C)
- Humidity: 0% to 95%
Environmental Icons:
- ?KEEP DRY
- ?FRAGILE
- ?INDOOR
NOTE: To enable the RV leveling function, install the Renogy ONE Core in a spot with the screen facing the desired direction (front, rear, left, or right) and vertically to the RV floor. Using RV leveling blocks is recommended during the leveling process.
Required Tools
Tools are only required for flush mounting on a wall.
- Phillips Screwdriver (#1)
- Insulation Tape
- Skill Saw
- Impact Drill with Hole Saw (2.17in / 55mm)
NOTE: You can use either a skill saw or an electric drill with a hole saw.
Step 1 (A): Place Renogy ONE Core on a Table
The package box is designed to be environmentally friendly and can be used as a bracket to hold the Core when wall installation is not required.
Instructions:
- Prepare the package box.
- Insert the Core into the prepared section of the box.
- The Core is now held securely.
NOTE: The RV leveling function is unavailable when the Core is placed on a table.
Step 1 (B): Mount Renogy ONE Core on a Wall
Instructions:
- Use the provided mounting template (tear off and paste to the desired location) or another piece of paper as a template. The installation hole size is 2.17 in x 2.17 in (55 mm x 55 mm).
- Align the template on the wall and mark the drilling points.
- Drill holes at the marked points.
- Attach the mounting bracket to the wall using the mounting screws. Ensure it is level using the bubble level.
- Connect the power cable and communication cable (if applicable) to the back of the Core.
- Align the Core with the bracket and slide it into place until it clicks.
- Ensure the device is securely mounted.
Diagrams illustrate using the template, drilling, attaching the bracket, connecting cables, and snapping the Core into place.
Step 2: Connect Renogy ONE Core to a Power Supply
Connect the Renogy ONE Core to a power supply using either the included power cable or an optional Type-C cable.
Installed on a Wall
- Using Power Cable: Connect the included power cable to the Power Port on the Core and to a DC power source (8V-32V). Ensure correct polarity: connect the negative terminal first, then the positive.
- Using Type-C Cable (Optional): Connect a 5V DC Type-C cable to the Type-C Port on the Core.
Installed on a Table
- Using Power Cable: Connect the included power cable to the Power Port on the Core and to a DC power source (8V-32V). Ensure correct polarity: connect the negative terminal first, then the positive.
- Using Type-C Cable (Optional): Connect a 5V DC Type-C cable to the Type-C Port on the Core.
NOTE: When installing the power cable, always connect the negative first, and then the positive.
Step 3: Install a Communication Cable (Optional)
For detailed instructions, refer to the Renogy ONE Core User Manual by scanning the QR code in the guide (QR code not displayed).
Connect the Communication Cable (max length: 19.6 ft / 6 m) to the Communication Port on the Core and to compatible devices (e.g., RS-485 or CAN for RSHGWSN-W02W-G2).
Step 4: Power On/Off
Long press the On/Off Button for 5 seconds to power the Core on or off.
Step 5: Pairing with DC Home
For initial startup, follow the startup wizard on the Core to pair it with the DC Home app. Alternatively, navigate to > System > Pair with App on the device.
Diagrams show the device interface for pairing and scanning a QR code with a smartphone.
Step 6: Add Devices
The Renogy ONE Core can wirelessly connect to Renogy Bluetooth, Bluetooth mesh, and Zigbee devices concurrently.
Process:
- On the Renogy ONE Core, select "Add Devices".
- The device scans for nearby Renogy devices (Controllers, Batteries, Smart Plugs, Inverters, Sensors, etc.).
- Select devices to add and confirm. The Core can also connect to the Internet.
Diagrams illustrate the device interface for adding devices and the types of Renogy devices that can be connected.
RV Leveling
The Renogy ONE Core features an RV leveling function.
Calibration: RV leveling calibration is required each time the installation site for the Core is changed.
Diagrams show the RV leveling interface on the Core and orientation selection.
Important Safety Instructions
- Keep Renogy ONE Core out of the reach of children.
- Dispose of Renogy ONE Core according to local, state, and federal laws and regulations, using designated recycling channels. Do not dispose of as household waste.
- Do not expose Renogy ONE Core to flammable or harsh chemicals or vapors.
- There are no serviceable parts inside. Do not open, dismantle, repair, tamper with, or modify the device.
- Confirm the polarities of connected devices before powering the Renogy ONE Core. Reverse polarity contact can cause damage and void the warranty.
- Ensure the connected DC power supply is rated between 8V to 32V. Exceeding this range can cause power-on failure or permanent damage.
- An extended power cable can be used if needed. Refer to the Renogy ONE Core User Manual for details.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception (which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. It should be installed and operated with a minimum distance of 20cm between the radiator and your body.
RSS Standard
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation.
The device complies with RF exposure guidelines. Canadian information on RF exposure and compliance can be obtained. The minimum distance from the body to use the device is 20cm.
Renogy Support
To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact Renogy:
A questionnaire investigation QR code is present but not displayed here.
To explore more possibilities of solar systems, visit the Renogy Learning Center:
Technical Support
For technical questions about your product in the U.S., contact Renogy technical support:
renogy.com/contact-us | 1(909)2877111
For technical support outside the U.S., visit local websites:
- Canada: ca.renogy.com
- Australia: au.renogy.com
- South Korea: kr.renogy.com
- United Kingdom: uk.renogy.com
- China: www.renogy.cn
- Japan: jp.renogy.com
- Germany: de.renogy.com
- Other Europe: eu.renogy.com
Disclaimer
Renogy ONE Core Quick Guide © 2024 Renogy. All rights reserved.
RENOGY and [Renogy logo] are registered trademarks of Renogy.
- All information in this quick guide is subject to copyright and intellectual property rights of Renogy and its licensors. Reproduction or copying, in whole or in part, is prohibited without prior written permission from Renogy and its licensors.
- Registered trademarks are the property of Renogy. Unauthorized use is strictly prohibited.
Renogy Empowered
Renogy aims to empower people globally through education and distribution of DIY-friendly renewable energy solutions. Renogy strives to be a driving force for sustainable living and energy independence, enabling users to minimize their carbon footprint by reducing reliance on grid power.
Live Sustainably with Renogy
Did you know? In a given month, a 1kW solar energy system can:
- Save 170 pounds of coal from being burned.
- Save 300 pounds of CO₂ from being released into the atmosphere.
- Save 105 gallons of water from being consumed.
Renogy Power PLUS
Renogy Power Plus is a community platform for staying updated on solar energy innovations, sharing experiences, and connecting with like-minded individuals.
Connect with Renogy on social media:
- YouTube: @Renogy Solar
- Instagram: @renogyofficial