Before Getting Started
This quick guide provides important operation and maintenance instructions for Renogy ONE Core (referred to as Core). Renogy ONE Core is available in two models: RSHGWSN-W02W-G1 (no CAN communication) and RSHGWSN-W02W-G2 (supports CAN communication). Read this guide carefully before operation and keep it for future reference. Failure to follow instructions or precautions may result in electrical shock, serious injury, or death, or damage to the Renogy ONE Core.
Renogy ensures accuracy and applicability at the time of printing, but product improvements may occur. Renogy is not liable for losses due to failure to install/use the product as per the guide. Renogy is not responsible for issues arising from repairs by unqualified personnel or improper installation/operation. Illustrations are for demonstration and may vary slightly. Renogy reserves the right to change information without notice. For the latest guide, visit renogy.com.
Links to online resources are provided via QR codes for a Quick Guide and a User Manual.
What's In the Box?
- Renogy ONE Core x 1
- Quick Guide x 1
- Mounting Screws x 4 (1 extra)
- Power Cable (5m) x 1
Get to Know RENOGY ONE Core
The back of the Renogy ONE Core features: Mounting Holes, On/Off Button, Communication Port, Bubble Level, Power Port, and Type-C Port.
Installation Site and Environment
Diagrams illustrate suitable installation locations within an RV, showing placement options and required 90° orientation for the screen. Unsuitable locations are marked with a red cross ❌.
Environmental Conditions:
- Altitude: ≤ 5000m
- Temperature: -4°F to 158°F (-20°C to 70°C)
- Humidity: 0% to 95%
Condition Icons: [Keep Dry] ?, [Fragile] ⚠️, [Indoor] ?.
To enable the RV leveling function, install the Core vertically with the screen facing front, rear, left, or right side of the RV, parallel to the RV floor. RV leveling blocks are recommended during the leveling process.
Step 1 (A). Place Renogy ONE Core on a Table
The package box is environmentally friendly and can be used as a bracket to hold the Core when wall installation is not required.
Diagrams show steps 1, 2, and 3 for using the package box as a stand.
The RV leveling function is unavailable on Core when it is placed on a table.
Step 1 (B). Mount Renogy ONE Core on a Wall
You can also use another piece of paper as the mounting template. The installation hole size is 2.17 in x 2.17 in (55 mm x 55 mm).
Diagrams illustrate the following steps:
- Using the mounting template.
- Attaching the template to the wall.
- Identifying the 'Yellow Area' and 'Blue Area' on the template for drilling.
- Removing the mounting bracket from the package.
- Aligning the mounting bracket with the pre-drilled holes.
- Securing the mounting bracket.
- Using a bubble level to ensure the bracket is mounted vertically (green checkmark ✔️ for level, red cross ❌ for not level).
- Securing the bracket to the wall using mounting screws.
- Connecting cables to the back of the Renogy ONE Core.
- Aligning the Renogy ONE Core with the mounted bracket at a 45° angle.
- Rotating the Core to lock it into place.
- Confirmation of secure attachment with an audible "Click".
Step 2. Connect Renogy ONE Core to a Power Supply
You can connect Renogy ONE Core to a power supply using the included power cable or an optional Type-C cable.
Installed on a Wall
- Connection 1: Using the included Power Cable to DC Power (8-32V).
- Connection 2: Using an optional Type-C Cable to 5V DC.
Installed on a Table
- Connection 1: Using the included Power Cable to 5V DC.
- Connection 2: Using an optional Type-C Cable to 5V DC.
When installing the power cable, always connect the negative terminal first, and then the positive terminal.
Step 3. Install a Communication Cable (Optional)
For details, see the Renogy ONE Core User Manual by scanning the QR code in the guide. The Communication Cable has a maximum length of 19.6 ft (6 m) and connects to devices via RS-485 or CAN (for RSHGWSN-W02W-G2).
Diagram shows the communication cable connecting to the Core and to various devices like a HUB, and other devices (RS-485 or CAN).
Step 4. Power On/Off
Long press the On/Off Button for 5 seconds to power the Core on or off.
Diagram shows a finger pressing the button for 5 seconds.
Step 5. Pairing with DC Home
For initial startup, follow the startup wizard on the Core to pair it with the DC Home app. Alternatively, navigate to > System > Pair with App
.
Diagrams show the device interface for System settings and the "Pair with App" option, including a QR code for scanning with the DC Home app.
Step 6. Add Devices
Renogy ONE Core can wirelessly connect to Renogy Bluetooth, Bluetooth mesh, and Zigbee devices concurrently.
Diagrams show the device interface for adding devices and examples of connected devices (Controller, Battery, Smart Plug, Inverter, Sensor).
RV Leveling
RV leveling calibration on Renogy ONE Core is required each time the installation site for the Core is changed.
Diagrams show the RV Leveling menu on the Core and the "Installation Orientation" screen where the user selects the screen's facing direction (e.g., "Screen currently facing rear").
Important Safety Instructions
- Keep Renogy ONE Core out of reach of children.
- Dispose of Renogy ONE Core according to local, state, and federal laws and regulations, using recycling channels.
- Do not expose Renogy ONE Core to flammable or harsh chemicals or vapors.
- There are no user-serviceable parts. Do not open, dismantle, repair, tamper with, or modify it.
- Confirm polarities before connecting to a power supply; reverse polarity can cause damage and void the warranty.
- Ensure the DC power supply is rated at 8V to 32V. Connecting to a source outside this range can cause power-on failure or permanent damage.
- An extended power cable can be used; refer to the User Manual for details.
Regulatory Compliance
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.
RSS Standard
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. The device is compliance with RF exposure guidelines; users can obtain Canadian information on RF exposure and compliance. The minimum distance from body to use the device is 20cm.
Renogy Support
To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact Renogy at: renogy.com/support/downloads or contentservice@renogy.com.
A QR code is provided for Questionnaire Investigation.
To explore more possibilities of solar systems, visit Renogy Learning Center at: renogy.com/learning-center.
Technical Support
For technical questions about your product in the U.S., contact the Renogy technical support team through: renogy.com/contact-us or 1(909)2877111.
For technical support outside the U.S., visit the local website below:
- Canada: ca.renogy.com
- Australia: au.renogy.com
- South Korea: kr.renogy.com
- United Kingdom: uk.renogy.com
- China: www.renogy.cn
- Japan: jp.renogy.com
- Germany: de.renogy.com
- Other Europe: eu.renogy.com
Disclaimer
Renogy ONE Core Quick Guide © 2024 Renogy. All rights reserved. RENOGY and Renogy are registered trademarks of Renogy. All information in this quick guide is subject to copyright and other intellectual property rights of Renogy and its licensors. The quick guide may not be modified, reproduced, or copied, in whole or in part, without prior written permission from Renogy and its licensors. The registered trademarks are the property of Renogy. Unauthorized use of trademarks is strictly prohibited.
Renogy Empowered
Renogy aims to empower people worldwide through education and distribution of DIY-friendly renewable energy solutions. Renogy strives to be a driving force for sustainable living and energy independence. Our solar products help minimize your carbon footprint by reducing reliance on grid power.
Live Sustainably with Renogy
Did you know? In a given month, a 1kW solar energy system can:
- Save 170 pounds of coal from being burned.
- Save 300 pounds of CO₂ from being released into the atmosphere.
- Save 105 gallons of water from being consumed.
Renogy Power PLUS
Renogy Power Plus allows you to stay updated on solar energy innovations, share your experiences, and connect with like-minded individuals in the Renogy Power Plus community.
Follow Renogy on YouTube @Renogy Solar, Instagram @renogyofficial, and Facebook @Renogy.
Renogy reserves the right to change the contents of this manual without notice.
Manufacturer Information
- Manufacturer: RENOGY New Energy Co.,Ltd. Address: No.66, East Ningbo Road Room 624-625 Taicang German Overseas Students Pioneer Park JiangSu 215000 CN. EC REP: eVatmaster Consulting GmbH, Battinastr. 30, 60325 Frankfurt am Main, Germany. contact@evatmaster.com.
- Manufacturer: RENOGY New Energy Co.,Ltd. Address: No.66, East Ningbo Road Room 624-625 Taicang German Overseas Students Pioneer Park JiangSu 215000 CN. UK REP: EVATOST CONSULTING LTD, Office 101 32 Threadneedle Street, London, United Kingdom, EC2R 8AY. contact@evatost.com.
FCC ID: 2ANPBGWSN-W03W
IC: 23590-RSHGWSNW03W
Visit us at RENOGY.COM.