Before Getting Started
This quick guide provides important operation and maintenance instructions for the Renogy ONE Core (referred to as Core). The Renogy ONE Core is available in two models: RSHGWSN-W02W-G1 (without CAN communication) and RSHGWSN-W02W-G2 and later versions (with CAN communication). Please read this guide carefully before operation and keep it for future reference. Failure to follow instructions or precautions may result in electrical shock, serious injury, or death, or damage to the Renogy ONE Core, potentially rendering it inoperable.
- Renogy ensures the accuracy and applicability of information at the time of printing, subject to product improvements.
- Renogy is not liable for losses resulting from improper installation or use contrary to this guide.
- Renogy is not responsible for failures, damages, or injuries from repairs by unqualified personnel or improper installation/operation.
- Illustrations are for demonstration; details may vary by product revision and region.
- Renogy reserves the right to change information without notice. For the latest guide, visit renogy.com.
For the full Online Manual, refer to the Quick Guide and User Manual sections.
What's In the Box?
The package includes:
- RENOGY ONE Core x 1
- Quick Guide x 1
- Mounting Screws x 4 (1 extra)
- Power Cable (5m) x 1
Get to Know RENOGY ONE Core
The Renogy ONE Core unit features:
- Mounting Holes: Multiple points for secure attachment.
- On/Off Button: For powering the device.
- Power Port: For connecting the power supply.
- Bubble Level: Integrated for ensuring vertical installation.
- Communication Port: For connecting communication cables.
- Type-C Port: An alternative port for power connection.
Installation Site and Environment
Ensure the installation site meets the following conditions:
- Orientation: The device should be installed vertically to the RV floor, with the screen facing the front, rear, left, or right side of the RV. RV leveling blocks are recommended during the leveling process.
- Altitude: Up to 5000m ⛰️.
- Temperature: -4°F to 158°F (-20°C to 70°C) ?️.
- Humidity: 0% to 95% ?.
- Conditions to Avoid: Exposure to rain ?️, fire ?, strong winds ?, or extreme temperatures ?️. The unit should be kept dry and is suitable for indoor use.
Required Tools
You will need:
- Phillips Screwdriver (#1) ?️
- Insulation Tape
- Skill Saw or Impact Drill with Hole Saw (2.17in / 55mm) ?
Mounting Template
Please use the provided template for drilling mounting holes. The required hole size is 2.17 inches (55 mm) in diameter.
(Diagram Description: A circular template with dimensions indicating the cutout size of 2.17 inches (55 mm) and screw hole positions.)
Step 1. Mount Renogy ONE Core
Follow these steps to mount the Renogy ONE Core:
- Prepare Template: Place the mounting template on the desired surface for drilling.
- Mark Holes: Secure the template and mark the drilling locations.
- Drill Holes: Drill pilot holes according to the template markings.
- Attach Bracket: Secure the mounting bracket to the surface using screws.
- Install Cover: Attach the blue plastic cover/ring to the mounting bracket.
- Check Level: Ensure the device is oriented correctly and level using the integrated bubble level.
- Secure Bracket: Tighten the mounting bracket screws.
- Connect Cables: Connect the power cable and communication cable (if applicable) to the back of the Renogy ONE Core unit.
- Align Device: Align the Renogy ONE Core unit with the mounting bracket at a 45° angle.
- Attach Device: Push the unit onto the bracket until it clicks securely into place.
(Diagram Description: A sequence of illustrations showing the process from placing the template, drilling holes, attaching the bracket, connecting cables, to snapping the device onto the bracket.)
Step 2. Connect Renogy ONE Core to a Power Supply
You can power the Renogy ONE Core using either the included power cable or an optional USB-C cable.
- Included Power Cable: Connect to a DC power source (8V to 35V ?). Ensure correct polarity: connect the negative terminal first, then the positive terminal.
- Optional USB-C Cable: Connect to a 5V DC power adapter ?.
Step 3. Install a Communication Cable (Optional)
Connect a communication cable (max length: 19.6 ft / 6 m) to link the Renogy ONE Core with other devices, such as Renogy HUB, RS-485, or CAN-compatible controllers, batteries, and inverters.
(Diagram Description: Shows a communication cable connecting the Renogy ONE Core to various compatible devices.)
Step 4. Power On/Off
To power the Renogy ONE Core on or off, long-press the On/Off Button for 5 seconds.
(Diagram Description: A hand pressing the On/Off button on the Renogy ONE Core unit for 5 seconds.)
Step 5. Pairing with DC Home
For initial setup, follow the on-screen startup wizard to pair the Core with the DC Home app. Alternatively, navigate to O > System > Pair with App on the device.
- Follow the device prompts or navigate the menu.
- Scan the QR code displayed on the Renogy ONE Core screen using the DC Home mobile app on your smartphone to complete the pairing process.
(Diagram Description: Shows navigating the device menu and scanning a QR code with a smartphone.)
Step 6. Add Devices
The Renogy ONE Core can wirelessly connect to Renogy Bluetooth, Bluetooth mesh, and Zigbee devices simultaneously.
- On the Renogy ONE Core, select "Add Devices".
- The device will discover nearby Renogy devices (e.g., Controllers, Batteries, Smart Plugs, Inverters, Door Sensors) and display them with their respective icons.
- Connect the Renogy ONE Core to the internet ? to enable data synchronization with the mobile app.
(Diagram Description: Shows selecting "Add Devices", discovering various device types with icons, and the unit connecting to the internet.)
RV Leveling (for Regions Outside the U.S.)
RV leveling calibration on the Renogy ONE Core is required each time the installation site for the Core is changed.
(Diagram Description: Illustrates an RV and the device's interface for RV leveling calibration.)
Important Safety Instructions
- Keep Renogy ONE Core out of the reach of children.
- Dispose of Renogy ONE Core according to local, state, and federal laws and regulations, using designated recycling channels. Do not dispose of as household waste.
- Do not expose Renogy ONE Core to flammable or harsh chemicals or vapors.
- There are no user-serviceable parts inside. Do not open, dismantle, repair, or modify the unit.
- Before connecting to a power supply, confirm the polarities of the devices. Reverse polarity contact can damage the Core and void the warranty.
- Ensure the connected DC power supply is rated between 8V and 35V. Connecting to a power source outside this range may cause power-on failure or permanent damage.
- An extended power cable can be used on demand. Refer to the Renogy ONE Core User Manual for details.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
RSS Standard
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation.
The device is compliant with RF exposure guidelines. Users can obtain Canadian information on RF exposure and compliance. The minimum distance from the body to use the device is 20cm.
Renogy Support
To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact Renogy:
- Website: renogy.com/support/downloads
- Email: contentservice@renogy.com
To explore more possibilities of solar systems, visit the Renogy Learning Center at: renogy.com/learning-center
Technical Support
For technical questions about your product in the U.S., contact the Renogy technical support team through:
- Website: renogy.com/contact-us
- Phone: 1(909)2877111
For technical support outside the U.S., visit the local website below:
- Canada: ca.renogy.com
- Australia: au.renogy.com
- Other Europe: eu.renogy.com
- United Kingdom: uk.renogy.com
- China: www.renogy.cn
- Japan: jp.renogy.com
- Germany: de.renogy.com
Disclaimer
© 2024 Renogy. All rights reserved. RENOGY and the Renogy logo are registered trademarks of Renogy.
- All information in this quick guide is subject to copyright and other intellectual property rights of Renogy and its licensors. The guide may not be modified, reproduced, or copied without prior written permission.
- Unauthorized use of Renogy's registered trademarks is strictly prohibited.
Renogy Empowered
Renogy aims to empower people globally through education and distribution of DIY-friendly renewable energy solutions, promoting sustainable living and energy independence. Renogy solar products help reduce carbon footprints by minimizing reliance on grid power.
Live Sustainably with Renogy
A 1kW solar energy system can significantly contribute to environmental protection.
Renogy Power PLUS
Join the Renogy Power Plus community to stay updated on solar innovations, share your experiences, and connect with others.
Follow Renogy on social media: @Renogy Solar, @renogyofficial, @Renogy
Manufacturer: RENOGY New Energy Co.,Ltd
Address: No.66, East Ningbo Road Room 624-625 Taicang German Overseas Students Pioneer Park, JiangSu 215000 CN
EC REP: eVatmaster Consulting GmbH, Battinastr. 30, 60325 Frankfurt am Main, Germany (contact@evatmaster.com)
UK REP: EVATOST CONSULTING LTD, Office 101, 32 Threadneedle Street, London, United Kingdom, EC2R 8AY (contact@evatost.com)
Website: RENOGY.COM
FCC ID: 2ANPBGWSN-W03W
IC: 23590-RSHGWSNW03W