eSSL JS-36E Security Standalone Access Control User Manual

JS-36E Security Standalone Access Control

Specifications

Kev Ua Haujlwm Voltage: DC12-24V

Ua haujlwm tam sim no: 100 mA

Kev khiav dej num: 0% -95%

Standby tam sim no: 60 mA

Ua haujlwm kub: -40-60 ° C

Access Ways: Fingerprint, card, code, multiple
combination methods, mobile phone App (Optional)

Cov lus qhia siv khoom

Kev teeb tsa

  1. Remove the back cover form the keypad using the supplied
    special screw drive.
  2. Drill 2 holes on the wall for the self-tapping screw and 1 hole
    rau kab.
  3. Put the supplied rubber bungs into the two holes.
  4. Fix the back cover firmly on the wall with 2 self-tapping
    ntsia hlau.
  5. Xov lub cable los ntawm lub qhov cable.
  6. Attach the keypad to the back cover. (Refer to figure for
    guidance)

Kev xaim

Xim cim Kev piav qhia
Pink Bell-A Door bell button on one end

Kev teeb tsa

  1. Master code #: Enter the programming mode,
    default factory master code is 999999.
  2. Qhov System Setting:
  • Change Master code: Enter 6 to 8 digits new code, repeat new
    code.
  • Reset to Factory Default #:
  • Chaw cia khoom

    1. Ntxiv cov neeg siv:
      1. Add card user: Input ID number, read card or input Card
        TSIS MUAJ.

    Cov lus nug nquag nug (FAQ)

    Q: Yuav ua li cas rov pib dua lub cuab yeej rau lub Hoobkas pib teeb tsa?

    A: To reset to factory default, enter the programming mode and
    use the specified code for resetting.

    Q: Dab tsi yog qhov kev ua haujlwm kub ntawm lub cuab yeej?

    A: Cov cuab yeej tuaj yeem ua haujlwm hauv qhov kub ntawm -40 ° C mus rau
    60 ° C.


    “`

    JS-36E User Manual
    Thov nyeem phau ntawv ua tib zoo ua ntej siv chav tsev no.

    1. Taw qhia
    This series’s product is a new generation on multifunctional standalone access control.It adopts new ARM core 32-bit microprocessor design, which is powerful, stable and reliable . It contains reader mode and standalone access control mode etc.. It’s widely applied to different occasions, such as office, residential communities, villa, bank and prison etc..

    2. Nta
    Daim npav hom
    Keypad Characteristic Output Way
    Access Way Admin Card User Capacity Unlock Signal Alarm Output

    Read 125KHz Card and HID Card(Optional) Read 13.56MHz Mifare card and CPU card(Optional) Capacitive touch keypad Contain reader mode, the transmission format could be adjusted by user Fingerprint , card,code or multiple combination methods, mobile phone App (Optional Support admin add card and admin delete card 10000 NO, NC, COM output using relay Use MOS tube output to directly drive the alarm (optional)

    3.Txoj kev qhia tshwj xeeb

    Kev Ua Haujlwm Voltage: DC12-24V Operating Current100mA
    Ua haujlwm av noo: 0% -95%

    Standby tam sim no 60mA
    Operating Temperature:-40-60
    Access waysFingerprint, card, code, multiple combination methods, mobile phone App (Optional

    01

    4. Kev teeb tsa
    Tshem tawm lub hau rov qab los ntawm lub qhov rooj uas siv cov ntsia hlau tshwj xeeb uas muab rau
    Drill 2 holes on the wall for the self-tapping screw and 1 hole for the cable Put the supplied rubber bungs to into the two holes Fix the back cover firmly on the wall with 2 self tapping screws Thread the cable through the cable hole Attached the keypad to the back cover.(See the figure right)

    5. Cov kab hluav taws xob

    Xim cim

    Kev piav qhia

    Pink Bell-A

    Qhov rooj tswb khawm ntawm qhov kawg

    Pink Bell-B

    Qhov rooj tswb khawm ntawm qhov kawg

    Green D0 White D1

    Wiegand input (Wiegand output as reader mode) Wiegabd inputWiegand output as reader mode

    Grey Alarm

    Tswb teeb liab MOS raj tso zis kawg

    Yellow Open(BEEP) Exit button input end(Beeper input as reader mode)

    Brown DIN(LED)

    Qhov rooj sensor hloov input kawg (daim ntawv nyeem hom LED tswj input)

    Liab

    + 12 V

    Muaj hwj huam zoo

    GND Dub

    Lub hwj chim tsis zoo

    Xiav TSIS

    Relay TSIS kawg

    Purple COM

    Relay COM kawg

    Orange NC

    Relay NC kawg

    02

    6. Daim duab
    1. Special power supply diagram

    Electric Rim Lock

    Electritc mortise lock Magnetic lock
    GND PUSH GND +12V NO NC

    AC 220 V

    Tawm khawm

    Red Black Purple Blue Yelow

    03

    6.2 Hom nyeem nyeem

    Liab Dub Ntsuab Dawb
    04

    7.System Setting

    Master code # Enter the programming mode,default factory master code is 999999.

    0.System Setting

    0.Change Master code

    Enter 6 to 8 digits new code # Repeat New code #

    1.Register Add Admin 2.Register Delete Admin

    Read card /input a fingerprint Read card /input a fingerprint

    3.Working Mode 4.Data Backup 5.WiFi matching

    0 #Reader mode) 1# (Standalone access control mode) 2# (Relay toggle mode)

    0 #Data backup output) 1# (Data backup input)

    # ……

    (The Green wire and white wire of machine connects correspondingly)

    7.Reset to Factory Default #

    8.Storage Space

    1.Add Users

    1.Add card user

    Input ID number read card or Input Card NO. #

    2.Add PIN code user

    Input ID number setting 4-6 digital door open code #

    3.Add Fingerprint user

    Input ID number press a fingerprint twice

    4.Add Fingerprint +Card user Read user card press fingerprint twice (Note: unregistered new fingerprint)

    5.Add conductive number Card Input ID number read card or input card number # input user quantity # 05

    2.Delete Users

    0.Delete all user

    # (Notice: admin code won’t be deleted. )

    1.Delete user ID number

    Input ID number

    #

    (Notice : Delete pointed card , fingerprint or PIN code users by user ID number. )

    2.Delete Card user

    Read card or Input Card number #

    3.Delete fingerprint user Press Fingerprint

    4.Delete temporary code # (Notice : Delete the temporary code issued by the mobile phone App.)

    3.Door Open Mode

    1.Door Open Way

    1. Forbidden (can’t open door) #
    2.Entry by code only # 3.Entry by card only # 4.Entry by card(fingerprint )+code only #
    5. Entry by card,code or fingerprint #
    6.Entry by fingerprint only #
    7. Entry by card+fingerprint #
    8.Entry by multiple users #

    2.Entry by multiple users Unlock by 1-10 users #

    06

    4. Lub sijhawm teem sijhawm

    1.Unlock time

    Tswv yim 0-300

    # (Time range 0~300S, Factory default: 5S)

    2.Alarm output time Input 0-99 # (Time range 0~99S, Factory default: 0S)

    3.Date & time setting Input date # Input time #

    5.Card Reader Model setting

    1.Device ID

    0-255 Device ID #

    2.Wiegand output

    WG26-58 #

    3.Keyboard format 0 #4 bit wg output) 1# (8 bit inverse code) 2# (virtual card number)

    6.Basic Settings

    1.Alarm model

    0# (Forbidden) 1# (Alarm) 2# (Locked)

    2.Keypad LED light 0~99 # Can set 0-99sFactory default 10S)

    3. Ntim

    0# (close) 1# (low) 2# (High)

    4.language

    0# (Chinese) 1# (English)

    07

    8.Reset rau Hoobkas Default
    When forget the administrator password,reset it to the factory default setting,The default administrator password is “999999” Method 1: Power off, power on, screen lights on,press the # key,The display will shows default settings is successful. Method 2: Power off,press the exit button continously,power on, The display will shows default settings is successful.
    Method 3: 0.system setting 7.Reset factory default setting #
    9. Reader mode switch to standalone access control mode When the device is under card reader mode, long press * to switch to standalone access control mode
    10. Cancel alarm
    Read admin card or read valid user card or valid fingerprint or admin password # Note: When alarm occurs, the buzzer will sound “woo, woo,…” and the alarm can be canceled by reading the valid card or inputting admin password.

    11.Packing npe

    Item Device User Manual Self-tapping screwdriver Rubber plug Star screwdriver Star screws

    Specification
    4mm×25 mm 6mm×28 mm 20mm×60mm 3mm×5mm

    Qty

    Lus ceeb toom

    1

    1

    2

    Rau mounting thiab fixin

    2

    Rau mounting thiab kho

    1

    lub hom phiaj tshwj xeeb

    1

    For fixing the front cover and

    rov qab cover

    Note: *Please do not repair the machine without permission. If there is any problem, please return it to the manufacturer for repair. *Before installation, if you want to drill holes, please carefully check the hidden wires or conduits to prevent unnecessary trouble caused by drilling the hidden wires when drilling. Use safety glasses when drilling or fixing wire clips. *If the product is upgraded, the instructions may be different without prior notice.

    08

    12. WIFI muaj nuj nqi

    xaiv tau

    1 Scan the QR code by your mobile phone to download the Tuya Smart APP or search the Tuya Smart APP to download APP by mobile phone application market (Figure 1)

    2 Open the APP, click the “+”at the upper right corner, Add Device (Figure 2) (Note: When searching for devices, turn on the

    Bluetooth and location services functions firstly)

    Nco tseg:

    At the same time, turn on the “wireless function on the access control.Press

    pairing” Admin

    tus password

    # 0. System settings

    # 5. WIFI pairing #

    3 Enter the WIFI password, then click Next. (Figure 3)

    Luam theej duab QR code
    TuyaSmart Search”TuyaSmart
    rub tawm
    TuyaSmart Search”TuyaSmart”
    rub tawm
    Search TuyaSmart to download APP Figure 1

    Daim duab 2

    Daim duab 3

    09

    4 Wait for successful connection,click Done

    AC

    AC

    5 Set remote unlock,click setting,open remote unlock setting
    AC

    10

    6 Press to unlock
    AC

    7 Member management Administrator Add fingerprint start adding input fingerprint twice add successfully,input name,click Done.

    ********

    ********

    11

    8

    Add code user by clicking add temporary code periodically, and input 6 digits code or click randomly generated, then

    input code name, and click save.

    9

    Add card by clicking start add, swiping one card within 60 seconds, add card successfully, then

    fill card name and click “done”.

    12

    Add ordinary user by clicking ordinary member, 10 then click at the upper right corner “+”, then input
    the related information and click “next step”.
    13

    11 Add temporary code, click `once”, input code name, click “save offline code”, done.
    AC
    14

    12 Query unlock records
    AC

    13 Settings: access ways, alarm time, volume, language.
    AC

    Click hereto check the unlock records 15

    Cov ntaub ntawv / Cov ntaub ntawv

    eSSL JS-36E Security Standalone Access Control [ua pdf] Tus neeg siv phau ntawv
    JS-36E Security Standalone Access Control, JS-36E, Security Standalone Access Control, Standalone Access Control, Access Control

    Cov ntaub ntawv

    Cia ib saib

    Koj email chaw nyob yuav tsis raug luam tawm. Cov teb uas yuav tsum tau muaj yog cim *