JS-36E Security Standalone Access Control
“
Specificazioni
Voltage: DC12-24V
Corrente di funziunamentu: 100 mA
Umidità operativa: 0% - 95%
Standby Current: 60 mA
Température de fonctionnement : -40-60 ° C
Access Ways: Fingerprint, card, code, multiple
combination methods, mobile phone App (Optional)
Istruzzioni per l'usu di u produttu
Installazione
- Remove the back cover form the keypad using the supplied
special screw drive. - Drill 2 holes on the wall for the self-tapping screw and 1 hole
per u cavu. - Put the supplied rubber bungs into the two holes.
- Fix the back cover firmly on the wall with 2 self-tapping
viti. - Passa u cable à traversu u foru di u cable.
- Attach the keypad to the back cover. (Refer to figure for
guidance)
Wiring
Marchi di culore | Descrizzione |
---|---|
Pink Bell-A | Door bell button on one end |
Configurazione di u Sistema
- Master code #: Enter the programming mode,
default factory master code is 999999. - Configurazione di u Sistema:
- Change Master code: Enter 6 to 8 digits new code, repeat new
codice.
Spaziu di almacenamiento
- Aggiungi utilizatori:
- Add card user: Input ID number, read card or input Card
INNÒ.
Domande Frequenti (FAQ)
Q: Cumu resettate u dispusitivu à i paràmetri predeterminati di fabbrica?
A: To reset to factory default, enter the programming mode and
use the specified code for resetting.
Q: Chì ghjè a gamma di temperatura di u funziunamentu di u dispusitivu?
A: U dispusitivu pò funziunà in una gamma di temperature da -40 ° C à
60 ° C.
"'
JS-36E User Manual
Leghjite attentamente u manuale prima di utilizà sta unità.
1. Introduzione
This series’s product is a new generation on multifunctional standalone access control.It adopts new ARM core 32-bit microprocessor design, which is powerful, stable and reliable . It contains reader mode and standalone access control mode etc.. It’s widely applied to different occasions, such as office, residential communities, villa, bank and prison etc..
2. Features
Tipu di carta
Keypad Characteristic Output Way
Access Way Admin Card User Capacity Unlock Signal Alarm Output
Read 125KHz Card and HID Card(Optional) Read 13.56MHz Mifare card and CPU card(Optional) Capacitive touch keypad Contain reader mode, the transmission format could be adjusted by user Fingerprint , card,code or multiple combination methods, mobile phone App (Optional Support admin add card and admin delete card 10000 NO, NC, COM output using relay Use MOS tube output to directly drive the alarm (optional)
3. Specificazioni Tecniche
Voltage: DC12-24V Operating Current100mA
Umidità operativa: 0% -95%
Corrente di standby 60mA
Operating Temperature:-40-60
Access waysFingerprint, card, code, multiple combination methods, mobile phone App (Optional
01
4. Installazione
Eliminate a copertina posteriore da u teclatu utilizendu l'unità di vite speciale furnita
Drill 2 holes on the wall for the self-tapping screw and 1 hole for the cable Put the supplied rubber bungs to into the two holes Fix the back cover firmly on the wall with 2 self tapping screws Thread the cable through the cable hole Attached the keypad to the back cover.(See the figure right)
5. Cablu
Marchi di culore
Descrizzione
Pink Bell-A
Pulsante di campanella di porta à a fine
Pink Bell-B
Pulsante di a campana di a porta à l'altra estremità
Green D0 White D1
Wiegand input (Wiegand output as reader mode) Wiegabd inputWiegand output as reader mode
Grey Alarm
Segnale d'allarme MOS di tubu di drenu di uscita fine
Yellow Open(BEEP) Exit button input end(Beeper input as reader mode)
Brown DIN(LED)
Fine di l'ingressu di l'interruttore di u sensoru di a porta (input di cuntrollu LED in modalità lettore di carte)
Rossu
+ 12 V
Alimentazione pusitiva
GND neru
Alimentazione negativa
Blu NO
Relay NO fine
Purple COM
Finu COM Relay
Orange NC
Relè NC fine
02
6. Diagramma
1. Special power supply diagram
Electric Rim Lock
Electritc mortise lock Magnetic lock
GND PUSH GND +12V NO NC
AC 220V
U buttone Esci
Red Black Purple Blue Yelow
03
6.2 Modu Reader
Rossu Negru Verde Bianco
04
7.Setting System
Master code # Enter the programming mode,default factory master code is 999999.
0.Setting System
0.Change Master code
Enter 6 to 8 digits new code # Repeat New code #
1.Register Add Admin 2.Register Delete Admin
Read card /input a fingerprint Read card /input a fingerprint
3.Working Mode 4.Data Backup 5.WiFi matching
0 #Reader mode) 1# (Standalone access control mode) 2# (Relay toggle mode)
0 #Data backup output) 1# (Data backup input)
# ……
(The Green wire and white wire of machine connects correspondingly)
7.Reset to Factory Default #
8.Storage Space
1.Add Users
1.Add card user
Input ID number read card or Input Card NO. #
2.Add PIN code user
Input ID number setting 4-6 digital door open code #
3.Add Fingerprint user
Input ID number press a fingerprint twice
4.Add Fingerprint +Card user Read user card press fingerprint twice (Note: unregistered new fingerprint)
5.Add conductive number Card Input ID number read card or input card number # input user quantity # 05
2.Delete Users
0.Delete all user
# (Notice: admin code won’t be deleted. )
1.Delete user ID number
Input ID number
#
(Notice : Delete pointed card , fingerprint or PIN code users by user ID number. )
2.Delete Card user
Read card or Input Card number #
3.Delete fingerprint user Press Fingerprint
4.Delete temporary code # (Notice : Delete the temporary code issued by the mobile phone App.)
3.Door Open Mode
1.Door Open Way
1. Forbidden (can’t open door) #
2.Entry by code only # 3.Entry by card only # 4.Entry by card(fingerprint )+code only #
5. Entry by card,code or fingerprint #
6.Entry by fingerprint only #
7. Entry by card+fingerprint #
8.Entry by multiple users #
2.Entry by multiple users Unlock by 1-10 users #
06
4.Setting Time
1.Unlock time
Input 0-300
# (Time range 0~300S, Factory default: 5S)
2.Alarm output time Input 0-99 # (Time range 0~99S, Factory default: 0S)
3.Date & time setting Input date # Input time #
5.Card Reader Model setting
1.Device ID
0-255 Device ID #
2.Wiegand output
WG26-58 #
3.Keyboard format 0 #4 bit wg output) 1# (8 bit inverse code) 2# (virtual card number)
6.Basic Settings
1.Alarm model
0# (Forbidden) 1# (Alarm) 2# (Locked)
2.Keypad LED light 0~99 # Can set 0-99sFactory default 10S)
3.Volume
0# (close) 1# (low) 2# (High)
4.language
0# (Chinese) 1# (English)
07
8.Reset à Factory Default
When forget the administrator password,reset it to the factory default setting,The default administrator password is “999999” Method 1: Power off, power on, screen lights on,press the # key,The display will shows default settings is successful. Method 2: Power off,press the exit button continously,power on, The display will shows default settings is successful.
Method 3: 0.system setting 7.Reset factory default setting #
9. Reader mode switch to standalone access control mode When the device is under card reader mode, long press * to switch to standalone access control mode
10. Cancel alarm
Read admin card or read valid user card or valid fingerprint or admin password # Note: When alarm occurs, the buzzer will sound “woo, woo,…” and the alarm can be canceled by reading the valid card or inputting admin password.
11.Packing list
Item Device User Manual Self-tapping screwdriver Rubber plug Star screwdriver Star screws
Specificazione
4mm×25 mm 6mm×28 mm 20mm×60mm 3mm×5mm
Qty
Rimarca
1
1
2
Per a stallazione è fissazione
2
Per a stallazione è a fissazione
1
scopu particulare
1
For fixing the front cover and
a copertina posteriore
Note: *Please do not repair the machine without permission. If there is any problem, please return it to the manufacturer for repair. *Before installation, if you want to drill holes, please carefully check the hidden wires or conduits to prevent unnecessary trouble caused by drilling the hidden wires when drilling. Use safety glasses when drilling or fixing wire clips. *If the product is upgraded, the instructions may be different without prior notice.
08
12. Funzione WIFI
facultativu
1 Scan the QR code by your mobile phone to download the Tuya Smart APP or search the Tuya Smart APP to download APP by mobile phone application market (Figure 1)
2 Open the APP, click the “+”at the upper right corner, Add Device (Figure 2) (Note: When searching for devices, turn on the
Bluetooth and location services functions firstly)
Nota:
At the same time, turn on the “wireless function on the access control.Press
pairing” Admin
codice
# 0. System settings
# 5. WIFI pairing #
3 Enter the WIFI password, then click Next. (Figure 3)
Scansà u codice QR
TuyaSmart Search”TuyaSmart
scaricate
TuyaSmart Search”TuyaSmart”
scaricate
Search TuyaSmart to download APP Figure 1
Figura 2
Figura 3
09
4 Wait for successful connection,click Done
AC
AC
5 Set remote unlock,click setting,open remote unlock setting
AC
10
6 Press to unlock
AC
7 Member management Administrator Add fingerprint start adding input fingerprint twice add successfully,input name,click Done.
********
********
11
8
Add code user by clicking add temporary code periodically, and input 6 digits code or click randomly generated, then
input code name, and click save.
9
Add card by clicking start add, swiping one card within 60 seconds, add card successfully, then
fill card name and click “done”.
12
Add ordinary user by clicking ordinary member, 10 then click at the upper right corner “+”, then input
the related information and click “next step”.
13
11 Add temporary code, click `once”, input code name, click “save offline code”, done.
AC
14
12 Query unlock records
AC
13 Settings: access ways, alarm time, volume, language.
AC
Click hereto check the unlock records 15
Documenti / Risorse
![]() |
eSSL JS-36E Security Standalone Access Control [pdfManuale d'usu JS-36E Security Standalone Access Control, JS-36E, Security Standalone Access Control, Standalone Access Control, Access Control |