eSSL JS-36E Feiligens Standalone Tagongskontrôle Brûkershânlieding

JS-36E Feiligens Standalone Tagongskontrôle

Spesifikaasjes

Operaasje Voltage: DC12-24V

Bedriuwsstroom: 100mA

Operaasje Feuchte: 0% -95%

Standby Strom: 60mA

Bedriuwstemperatuer: -40-60°C

Access Ways: Fingerprint, card, code, multiple
combination methods, mobile phone App (Optional)

Produkt Usage Ynstruksjes

Ynstallaasje

  1. Remove the back cover form the keypad using the supplied
    special screw drive.
  2. Drill 2 holes on the wall for the self-tapping screw and 1 hole
    foar de kabel.
  3. Put the supplied rubber bungs into the two holes.
  4. Fix the back cover firmly on the wall with 2 self-tapping
    skroeven.
  5. Fier de kabel troch it kabelgat.
  6. Attach the keypad to the back cover. (Refer to figure for
    guidance)

Wiring

Kleur Marks Beskriuwing
Pink Bell-A Door bell button on one end

Systeem ynstelling

  1. Master code #: Enter the programming mode,
    default factory master code is 999999.
  2. Systeemynstelling:
  • Change Master code: Enter 6 to 8 digits new code, repeat new
    koade.
  • Reset to Factory Default #:
  • Opslachromte

    1. Brûkers tafoegje:
      1. Add card user: Input ID number, read card or input Card
        NEE.

    Faak stelde fragen (FAQ)

    F: Hoe kinne jo it apparaat weromsette nei fabrieksynstellingen?

    A: To reset to factory default, enter the programming mode and
    use the specified code for resetting.

    F: Wat is it wurktemperatuerberik fan it apparaat?

    A: It apparaat kin wurkje binnen in temperatuer berik fan -40 ° C oant
    60°C.


    "`

    JS-36E User Manual
    Lês asjebleaft de hantlieding foarsichtich foardat jo dizze ienheid brûke.

    1. Ynlieding
    This series’s product is a new generation on multifunctional standalone access control.It adopts new ARM core 32-bit microprocessor design, which is powerful, stable and reliable . It contains reader mode and standalone access control mode etc.. It’s widely applied to different occasions, such as office, residential communities, villa, bank and prison etc..

    2. Features
    Card Type
    Keypad Characteristic Output Way
    Access Way Admin Card User Capacity Unlock Signal Alarm Output

    Read 125KHz Card and HID Card(Optional) Read 13.56MHz Mifare card and CPU card(Optional) Capacitive touch keypad Contain reader mode, the transmission format could be adjusted by user Fingerprint , card,code or multiple combination methods, mobile phone App (Optional Support admin add card and admin delete card 10000 NO, NC, COM output using relay Use MOS tube output to directly drive the alarm (optional)

    3. Technyske spesifikaasjes

    Operaasje Voltage: DC12-24V Operating Current100mA
    Bedriuwsfochtichheid: 0% -95%

    Standby Strom 60mA
    Operating Temperature:-40-60
    Access waysFingerprint, card, code, multiple combination methods, mobile phone App (Optional

    01

    4. Ynstallaasje
    Fuortsmite de efterkant fan it toetseboerd mei help fan de levere spesjale screw drive
    Drill 2 holes on the wall for the self-tapping screw and 1 hole for the cable Put the supplied rubber bungs to into the two holes Fix the back cover firmly on the wall with 2 self tapping screws Thread the cable through the cable hole Attached the keypad to the back cover.(See the figure right)

    5. Bedrading

    Kleur Marks

    Beskriuwing

    Pink Bell-A

    Doarbelknop op ein

    Pink Bell-B

    Doarbel knop oan 'e oare ein

    Green D0 White D1

    Wiegand input (Wiegand output as reader mode) Wiegabd inputWiegand output as reader mode

    Grey Alarm

    Alarm sinjaal MOS tube drain útfier ein

    Yellow Open(BEEP) Exit button input end(Beeper input as reader mode)

    Brown DIN(LED)

    Doarsensor switch ynfier ein (kaartlêzer modus LED control input)

    Read

    +12V

    Posityf macht oanbod

    Swarte GND

    Negatyf macht oanbod

    Blau NO

    Relais NO ein

    Purple COM

    Relay COM ein

    Orange NC

    Relay NC ein

    02

    6. Diagram
    1. Special power supply diagram

    Electric Rim Lock

    Electritc mortise lock Magnetic lock
    GND PUSH GND +12V NO NC

    AC 220V

    Útgong knop

    Red Black Purple Blue Yelow

    03

    6.2 Reader Mode

    Rood Swart Grien Wyt
    04

    7.Systeemynstelling

    Master code # Enter the programming mode,default factory master code is 999999.

    0.Systeemynstelling

    0.Change Master code

    Enter 6 to 8 digits new code # Repeat New code #

    1.Register Add Admin 2.Register Delete Admin

    Read card /input a fingerprint Read card /input a fingerprint

    3.Working Mode 4.Data Backup 5.WiFi matching

    0 #Reader mode) 1# (Standalone access control mode) 2# (Relay toggle mode)

    0 #Data backup output) 1# (Data backup input)

    # ……

    (The Green wire and white wire of machine connects correspondingly)

    7.Reset to Factory Default #

    8.Storage Space

    1.Add Users

    1.Add card user

    Input ID number read card or Input Card NO. #

    2.Add PIN code user

    Input ID number setting 4-6 digital door open code #

    3.Add Fingerprint user

    Input ID number press a fingerprint twice

    4.Add Fingerprint +Card user Read user card press fingerprint twice (Note: unregistered new fingerprint)

    5.Add conductive number Card Input ID number read card or input card number # input user quantity # 05

    2.Delete Users

    0.Delete all user

    # (Notice: admin code won’t be deleted. )

    1.Delete user ID number

    Input ID number

    #

    (Notice : Delete pointed card , fingerprint or PIN code users by user ID number. )

    2.Delete Card user

    Read card or Input Card number #

    3.Delete fingerprint user Press Fingerprint

    4.Delete temporary code # (Notice : Delete the temporary code issued by the mobile phone App.)

    3.Door Open Mode

    1.Door Open Way

    1. Forbidden (can’t open door) #
    2.Entry by code only # 3.Entry by card only # 4.Entry by card(fingerprint )+code only #
    5. Entry by card,code or fingerprint #
    6.Entry by fingerprint only #
    7. Entry by card+fingerprint #
    8.Entry by multiple users #

    2.Entry by multiple users Unlock by 1-10 users #

    06

    4.Tiid ynstelling

    1.Unlock time

    Ynfier 0-300

    # (Time range 0~300S, Factory default: 5S)

    2.Alarm output time Input 0-99 # (Time range 0~99S, Factory default: 0S)

    3.Date & time setting Input date # Input time #

    5.Card Reader Model setting

    1.Device ID

    0-255 Device ID #

    2.Wiegand output

    WG26-58 #

    3.Keyboard format 0 #4 bit wg output) 1# (8 bit inverse code) 2# (virtual card number)

    6.Basic ynstellings

    1.Alarm model

    0# (Forbidden) 1# (Alarm) 2# (Locked)

    2.Keypad LED light 0~99 # Can set 0-99sFactory default 10S)

    3. Volume

    0# (close) 1# (low) 2# (High)

    4.language

    0# (Chinese) 1# (English)

    07

    8.Reset nei Factory Standert
    When forget the administrator password,reset it to the factory default setting,The default administrator password is “999999” Method 1: Power off, power on, screen lights on,press the # key,The display will shows default settings is successful. Method 2: Power off,press the exit button continously,power on, The display will shows default settings is successful.
    Method 3: 0.system setting 7.Reset factory default setting #
    9. Reader mode switch to standalone access control mode When the device is under card reader mode, long press * to switch to standalone access control mode
    10. Cancel alarm
    Read admin card or read valid user card or valid fingerprint or admin password # Note: When alarm occurs, the buzzer will sound “woo, woo,…” and the alarm can be canceled by reading the valid card or inputting admin password.

    11.Packing list

    Item Device User Manual Self-tapping screwdriver Rubber plug Star screwdriver Star screws

    Spesifikaasje
    4mm×25 mm 6mm×28 mm 20mm×60mm 3mm×5mm

    Oantal

    Opmerking

    1

    1

    2

    Foar montage en fixin

    2

    Foar mounting en fixing

    1

    spesjaal doel

    1

    For fixing the front cover and

    de efterkant

    Note: *Please do not repair the machine without permission. If there is any problem, please return it to the manufacturer for repair. *Before installation, if you want to drill holes, please carefully check the hidden wires or conduits to prevent unnecessary trouble caused by drilling the hidden wires when drilling. Use safety glasses when drilling or fixing wire clips. *If the product is upgraded, the instructions may be different without prior notice.

    08

    12. WIFI -funksje

    fakultatyf

    1 Scan the QR code by your mobile phone to download the Tuya Smart APP or search the Tuya Smart APP to download APP by mobile phone application market (Figure 1)

    2 Open the APP, click the “+”at the upper right corner, Add Device (Figure 2) (Note: When searching for devices, turn on the

    Bluetooth and location services functions firstly)

    Noat:

    At the same time, turn on the “wireless function on the access control.Press

    pairing” Admin

    wachtwurd

    # 0. System settings

    # 5. WIFI pairing #

    3 Enter the WIFI password, then click Next. (Figure 3)

    Scan QR-koade
    TuyaSmart Search”TuyaSmart
    download
    TuyaSmart Search”TuyaSmart”
    download
    Search TuyaSmart to download APP Figure 1

    figuer 2

    figuer 3

    09

    4 Wait for successful connection,click Done

    AC

    AC

    5 Set remote unlock,click setting,open remote unlock setting
    AC

    10

    6 Press to unlock
    AC

    7 Member management Administrator Add fingerprint start adding input fingerprint twice add successfully,input name,click Done.

    ********

    ********

    11

    8

    Add code user by clicking add temporary code periodically, and input 6 digits code or click randomly generated, then

    input code name, and click save.

    9

    Add card by clicking start add, swiping one card within 60 seconds, add card successfully, then

    fill card name and click “done”.

    12

    Add ordinary user by clicking ordinary member, 10 then click at the upper right corner “+”, then input
    the related information and click “next step”.
    13

    11 Add temporary code, click `once”, input code name, click “save offline code”, done.
    AC
    14

    12 Query unlock records
    AC

    13 Settings: access ways, alarm time, volume, language.
    AC

    Click hereto check the unlock records 15

    Dokuminten / Resources

    eSSL JS-36E Security Standalone Access Control [pdf] Brûkershânlieding
    JS-36E Security Standalone Access Control, JS-36E, Security Standalone Access Control, Standalone Access Control, Access Control

    Referinsjes

    Lit in reaksje efter

    Jo e-mailadres sil net publisearre wurde. Ferplichte fjilden binne markearre *