Alamar IntesisIntesis logo hms
Sabis na Modbus
Modbus RTU Master da Modbus TCP bawa
MANHAJAR MAI AMFANI
Ranar fitowar: 02/2020 r1.2 HAUSA
Intesis TM Modbus TCP - Modbus RTU
Sabis na Modbus na Intesis -

Mahimmin Bayanin Mai amfani

Disclaimer

Bayanin da ke cikin wannan takaddar don dalilai ne na bayani kawai. Da fatan za a sanar da Hanyoyin Sadarwar Masana'antu na HMS game da duk wani kuskure ko rashi da aka samu a cikin wannan takaddar. Hanyoyin Sadarwar Masana'antu na HMS sun watsar da duk wani nauyi ko alhaki na duk wani kuskure da zai iya bayyana a cikin wannan takaddar.
Hanyoyin Sadarwar Masana'antu na HMS suna da haƙƙin haɓaka samfuranta daidai da manufofinta na ci gaba da haɓaka samfura. Ba za a iya ɗaukar bayanin da ke cikin wannan takaddar azaman ƙaddamarwa a kan HMS Masana'antun Masana'antu ba kuma zai iya canzawa ba tare da sanarwa ba. Hanyoyin Sadarwar Masana'antu na HMS ba sa alƙawarin sabuntawa ko kiyaye bayanan a cikin wannan takaddar.
Bayanan, examples, da zane-zane da aka samo a cikin wannan takarda an haɗa su don dalilai na misali kuma an yi nufin su kawai don taimakawa haɓaka fahimtar ayyuka da sarrafa samfurin. A ciki view na nau'ikan yuwuwar aikace-aikacen samfurin, kuma saboda yawancin masu canji da buƙatun da ke da alaƙa da kowane takamaiman aiwatarwa, Cibiyar Sadarwar Masana'antu ta HMS ba za ta iya ɗaukar nauyi ko alhaki don ainihin amfani dangane da bayanan ba, misali.amples, ko zane -zane da aka haɗa a cikin wannan takaddar ko kuma ga kowane lahani da aka samu yayin shigar da samfurin. Waɗanda ke da alhakin amfani da samfurin dole ne su sami isasshen ilimin don tabbatar da cewa an yi amfani da samfurin daidai a cikin takamaiman aikace -aikacen su kuma cewa aikace -aikacen ya cika duk buƙatun aiki da aminci gami da duk wasu dokoki, ƙa'idodi, lambobin, da ƙa'idodi. Bugu da ƙari, Cibiyar Sadarwar Masana'antu ta HMS ba a kowane yanayi zata ɗauki alhaki ko alhakin duk wata matsala da ka iya tasowa sakamakon amfani da fasalullukan da ba su da takardu ko tasirin aikin da aka samu a wajen fakitin samfurin. Illolin da ke haifar da duk wani amfani kai tsaye ko a kaikaice na irin waɗannan fannonin samfurin ba a fayyace su ba kuma yana iya haɗawa da alamarin daidaituwa da matsalolin kwanciyar hankali.

Router don haɗin shigar Modbus RTU cikin Modbus TCP-kunna tsarin sa ido da sarrafawa.

TAKARDAR ODAR  CODE LEGACY ORDER 
Saukewa: INMBSRTR0320000 Saukewa: IBMBSRTR0320000

Bayani

Gabatarwa

Wannan takaddar tana bayanin yadda ake aika saƙon tsakanin Modbus RTU da Modbus TCP cibiyoyin sadarwa ta amfani da Intesis Modbus RTU zuwa Modbus TCP Router.
Manufar wannan haɗin kai shine yin bayanai masu sauƙi daga na'urori a cikin hanyar sadarwa ta Modbus RTU zuwa hanyar sadarwa ta Modbus TCP ta hanyar gaskiya.
Ana aiwatar da daidaitawa ta amfani da software na sanyi IntesisTM MAPS.
Wannan takaddar tana ɗaukar cewa mai amfani ya saba da fasahar Modbus da sharuddan fasaharsu.

Sabis na Modbus na Intesis -Sanarwa

Routing tsakanin Modbus RTU da Modbus TCP

Ayyuka

Bayan aiwatar da farawa, Intesis yana taimakawa hanyar sadarwa na Modbus daga Modbus TCP zuwa hanyoyin sadarwa na Modbus RTU, yana ba da damar na'urorin Modbus TCP don sadarwa tare da na'urorin Modbus RTU da ke cikin wata hanyar sadarwa.
Ba lallai ba ne a yi kowane taswira kamar yadda aka nuna bayanan daga gefe ɗaya a gefe ɗaya ta hanyar gaskiya.
Hakanan na'urar na'ura mai ba da hanya tsakanin hanyoyin sadarwa tana da siginar bincike da ake samu ta tashar TCP 503 don duba cewa duk sadarwa daga kowane bangare tana aiki yadda yakamata.

Ikon na'ura mai ba da hanya tsakanin hanyoyin sadarwa

An jera ƙarfin intesis a ƙasa:

Abun ciki  32 na'urori  Bayanan kula 
Nau'in Modbus
na'urorin bawa
Modbus RTU (EIA485)
ModCP TCP
Wadanda ke tallafawa Modbus
yarjejeniya. Sadarwa ta ƙare
TCP/IP da RTU
Yawan Modbus
na'urorin bawa
Har zuwa 32 kayan aikin RTU masu cikakken nauyi Yawan bawan Modbus
na'urorin da na'urar ke tallafawa

Haɗin kai

Nemo bayanan da ke ƙasa game da haɗin Intesis da ke akwai.

Tushen wutan lantarki
Dole ne yayi amfani da NEC Class 2 ko Ƙarfin Wutar Lantarki (LPS) da ƙimar wutar lantarki ta SELV. Ana girmama polarity na tashoshi (+) da (-). Tabbatar cewa voltage aikace -aikacen yana cikin kewayon da aka yarda (duba teburin da ke ƙasa). Ana iya haɗa ƙarfin wutan lantarki da ƙasa amma ta hanyar mummunan tashar, ba ta hanyar madaidaicin tashar ba.

Ethernet
Haɗa kebul ɗin da ke fitowa daga cibiyar sadarwar IP zuwa mai haɗa ETH na ƙofar. Yi amfani da kebul na CAT5 na Ethernet. Idan sadarwa ta hanyar LAN na ginin, tuntuɓi mai kula da cibiyar sadarwar kuma tabbatar an ba da izinin zirga-zirga a tashar da aka yi amfani da ita ta duk hanyar LAN (bincika littafin mai amfani da ƙofar don ƙarin bayani). Tare da saitunan ma'aikata, bayan kunna ƙofa, DHCP za a kunna na dakika 30. Bayan wannan lokacin, idan ba a samar da IP ta hanyar sabar DHCP ba, za a saita tsoho IP 192.168.100.246.

Port Modbus RTU
Haɗa motar EIA485 zuwa masu haɗawa A3 (B+), A2 (A-), da A1 (SNGD) na Ƙofar Ƙofar. Girmama polarity.

Lura don tashar jiragen ruwa ta EIA485; Ka tuna halayen daidaitaccen bas na EIA485: mafi girman nisan mita 1200, matsakaicin na'urori 32 da aka haɗa da motar, kuma a kowane ƙarshen bas ɗin dole ne ya zama mai tsayayyar ƙarewar 120 Ω.

Intesis Modbus Server -Haɗin

Tabbatar sararin da ya dace ga duk masu haɗin kai lokacin da aka ɗora su (duba sashe na 5).

Ƙarfafa na'urar

Wutar lantarki tana aiki tare da kowane voltagAna buƙatar iyakar iyaka (duba sashe na 4). Da zarar an haɗa RUN jagoranci (Hoto a sama) zai kunna.
GARGADI! Don guje wa madaukai na ƙasa waɗanda zasu iya lalata ƙofar da/ko duk wani kayan aikin da ke da alaƙa da shi, muna ba da shawarar sosai:

  • Amfani da wutan lantarki na DC, yana iyo ko tare da mummunan tashar da aka haɗa da ƙasa. Kada kayi amfani da wutar lantarki ta DC tare da madaidaicin tashar da aka haɗa da duniya.
Haɗa zuwa Modbus

ModCP TCP

Haɗa kebul na sadarwar da ke zuwa daga cibiyar sadarwa ko canzawa zuwa tashar ETH na Intesis. Kebul da za a yi amfani da shi zai zama madaidaiciyar Ethernet UTP/FTP CAT5 kebul.

 Modbus RTU

Haɗa kebul na sadarwa da ke zuwa daga hanyar sadarwa ta Modbus zuwa tashar jiragen ruwa mai alamar Modbus na Intesis. Haɗa motar EIA485 zuwa masu haɗa A3 (B+), A2 (A-), da A1 (SGND). Girmama polarity.
Ka tuna halayen daidaitaccen bas na EIA485: mafi girman nisan mita 1200, matsakaicin na'urori 32 da aka haɗa da motar, kuma a kowane ƙarshen bas ɗin dole ne ya zama mai tsayayyar ƙarewar 120 Ω.

Haɗa zuwa kayan aikin sanyi

Wannan aikin yana bawa mai amfani damar samun damar daidaitawa da saka idanu na na'urar (ana iya samun ƙarin bayani a cikin kayan aikin mai amfani da kayan aikin sanyi). Ana iya amfani da hanya ɗaya don haɗawa da PC:

  • Ethernet: Amfani da tashar Ethernet na Intesis.

Tsarin saiti da gyara matsala

Abubuwan da ake bukata

Ya zama dole a sami aikin Modbus TCP mai aiki da kayan aiki kuma an haɗa shi sosai da tashar Modbus ta Intesis da bawan Modbus RTU da aka haɗa da tashar da ta dace.
Masu haɗawa, igiyoyi masu haɗi, PC don amfani da kayan aikin daidaitawa, da sauran kayan taimako, idan an buƙata, ba HMS Masana'antar Sadarwar Masana'antu ta SLU ke ba su don wannan daidaitaccen haɗin kai.
Abubuwan da aka samar da HMS Networks don wannan haɗakar sune:

  •  Esisofar Intesis.
  •  Haɗa don sauke kayan aikin sanyi.
  • Takaddun samfur.
Farashin MAPS. Kanfigareshi & saka idanu kayan aikin Intesis Modbus jerin

Gabatarwa

Intesis MAPS software ce mai jituwa ta Windows® wacce aka haɓaka musamman don saka idanu da daidaita jerin Intbus Modbus.
Anyi bayanin tsarin shigarwa da manyan ayyuka a cikin Jagorar Mai Amfani na Intesis MAPS. Ana iya saukar da wannan takaddar daga hanyar haɗin da aka nuna a cikin takardar shigarwa da aka kawo tare da na'urar Intesis ko akan samfurin websaiti a www.intesis.com
A cikin wannan sashin, takamaiman yanayin tsarin Modbus Router kawai za a rufe.
Da fatan za a duba littafin mai amfani na Intesis MAPS don takamaiman bayani game da sigogi daban -daban da yadda ake saita su.

Haɗin kai

Don saita sigogin haɗin Intesis danna maɓallin Haɗin kai button a cikin menu.Sabis na Modbus na Intesis -3.1 Shafin daidaitawa

Zaɓi Saitin Kanfigareshan don saita sigogin haɗin. Ana nuna rabe -raben bayanai guda uku a cikin wannan taga: Gabaɗaya (sigogin janar na Gateway), bawan Modbus (Tsarin keɓancewar bautar Modbus TCP), da Modbus Router (Modbus TCP & RTU interfaces interfaces).
Sabis na Modbus na Intesis -3.2Sigina

Duk siginar da ke akwai, rajistan Modbus ɗin su, da sauran mahimman sigogi an jera su a shafin sigina. Ana iya samun ƙarin bayani akan kowane sigogi da yadda ake saita shi a cikin littafin mai amfani na Intesis MAPS.

Sabis na Modbus na Intesis -3.3

Aika saitin zuwa Intesis

Lokacin da sanyi ya gama, bi matakai na gaba.

  1. - Danna maɓallin Ajiye don adana aikin zuwa babban fayil ɗin aikin akan diski ɗinku (ƙarin bayani a cikin Jagorar Mai amfani na Intesis MAPS).
  2. - Za a sa ku don ƙirƙirar sanyi file da za a aika zuwa ƙofar.
    a.- Idan Ee aka zaɓi, da file wanda ke ɗauke da tsari don ƙofar za a samar da adana shi kuma a cikin babban fayil ɗin aikin.
    b.- Idan NO aka zaɓi, tuna cewa binary file tare da aikin yana buƙatar ƙirƙirar kafin Intesis ya fara aiki kamar yadda aka zata.
  3. - Danna Aika File button don aika binary file zuwa na'urar Intesis. Tsarin file Ana iya sa ido kan watsawa a cikin taga Console Communication. Intesis zai sake farawa ta atomatik da zarar an ɗora sabon saitin.

Sabis na Modbus na Intesis -3.4

Bayan kowane canje -canjen sanyi, kar a manta a aika saitin file zuwa Intesis ta amfani da maɓallin Aika File.

Bincike

Don taimakawa masu haɗin kai a cikin ayyukan ƙaddamarwa da gyara matsala, Kayan Kanfigareshan yana ba da takamaiman kayan aikin da viewers.
Don fara amfani da kayan aikin bincike, ana buƙatar haɗi tare da Ƙofar.
Sashin Bincike ya ƙunshi manyan sassa biyu: Kayan aiki da Viewers.

  •  Kayan aiki
    Yi amfani da sashin kayan aikin don bincika matsayin kayan aikin yanzu na akwati, shigar da hanyoyin sadarwa cikin matsa fileda za a aika zuwa tallafi, canza bangarorin bincike ' view ko aika umarni zuwa ƙofar.
  •  Viewers
    Don bincika halin yanzu, viewers don ladabi na ciki da waje suna samuwa. Hakanan ana samun shi Console na asali viewer don cikakkun bayanai game da sadarwa da matsayin ƙofar kuma a ƙarshe sigina Viewer don yin kwaikwayon halayyar BMS ko don bincika ƙimar yanzu a cikin tsarin.Sabis na Modbus na Intesis -3.5

Ana iya samun ƙarin bayani game da sashen Bincike a cikin littafin Kayan aikin Kanfigareshan.

Tsarin saiti
  1. Shigar da Taswirar Intesis akan kwamfutar tafi-da-gidanka, yi amfani da tsarin saitin da aka bayar don wannan kuma bi umarnin da wizard wizard ya bayar.
  2.  Sanya Intesis a cikin shafin shigarwa da ake so. Shigarwa na iya kasancewa a kan dogo na DIN ko a barga ba farfajiyar faɗakarwa ba (DIN da aka ɗora a cikin ƙaramin ma'aikatar masana'antar ƙarfe da aka haɗa da ƙasa ana ba da shawarar.)
  3.  Haɗa kebul na sadarwa da ke zuwa daga Modbus TCP cibiyar sadarwa zuwa tashar jiragen ruwa da aka yiwa alama azaman Ethernet akan Intesis (ƙarin cikakkun bayanai a sashe na 2).
  4.  Haɗa kebul na sadarwa da ke fitowa daga tashar EIA485 na Modbus RTU shigarwa zuwa tashar da aka yiwa lakabi da Modbus RTU na Intesis (ƙarin cikakkun bayanai a sashe na 2).
  5.  Ƙarfafa Intesis. The wadata voltage na iya zama 9 zuwa 30 Vdc. Kula da polarity na wadata voltage nema.
    GARGADI! Don gujewa madaukai na ƙasa waɗanda zasu iya lalata Intesis da / ko duk wani kayan aikin da aka haɗa da shi, muna bada shawara mai ƙarfi:
    • Amfani da wutar lantarki na DC, yana iyo ko tare da mummunan tashar da aka haɗa da ƙasa. Kada kayi amfani da a Wutar lantarki ta DC tare da madaidaicin tashar da aka haɗa da ƙasa.
  6.  Idan kuna son haɗawa ta amfani da IP, haɗa kebul na Ethernet daga kwamfutar tafi -da -gidanka zuwa tashar jiragen ruwa da aka yiwa alama azaman ETH na Intesis (ƙarin cikakkun bayanai a sashe na 2).
  7.  Buɗe Intesis MAPS, ƙirƙirar sabon aikin zaɓi kwafin wanda ake kira INMBSRTR0320000.
  8.  Gyara saitin yadda ake so, adana shi kuma zazzage saitin file zuwa Intesis kamar yadda aka bayyana a cikin littafin mai amfani na Intesis MAPS.
  9.  Ziyarci sashin bincike kuma duba cewa akwai ayyukan sadarwa, wasu firam ɗin TX, da wasu firam ɗin RX. Wannan yana nufin cewa sadarwa tare da Modib TCP Client device/s da Modbus RTU na’urorin bayi suna da kyau. Idan babu aikin sadarwa tsakanin Intesis da na'urorin Modbus, duba cewa waɗancan masu aiki ne: duba ƙimar baud, kebul ɗin sadarwa da aka yi amfani da shi don haɗa dukkan na'urori, da kowane siginar sadarwa.

Lantarki & Injin Fasaha

Sabis ɗin Modbus na Intesis -Fasahar Inganci & Injiniya

Yadi Roba, rubuta PC (UL 94 V-0)
Matsakaicin ma'auni (dxwxh): 93x53x58 mm
Shawara sarari don shigarwa (dxwxh): 100x60x70mm
Launi: Grey mai haske. Farashin 7035
Yin hawa Bango.
DIN dogo EN60715 TH35.
Iringarfin Waya
(don samar da wutar lantarki da
low-voltage sigina)
Per terminal: daskararrun wayoyi ko igiyoyin igiya (karkatattu ko tare da ferrule)
1 core: 0.5mm 2… 2.5mm2
2 tsakiya: 0.5mm 2… 1.5mm2
3 tsakiya: ba a yarda ba
Ƙarfi 1 x Toshe maƙallan toshe (sanduna 3)
Tabbatacce, Korau, Duniya
9-36 VDC / 24 VAC / 50-60 Hz / 0.140 A / 1.7 W.
Ethernet 1 x Ethernet 10/100Mbps RJ45
2 x Ethernet LED: haɗin tashar jiragen ruwa da aiki
Port 1 x Serial EIA485 (Toshe-a dunƙule m toshe sanda 3)
A, B, SGND (Shafin ƙasa ko garkuwa)
Raba 1500VDC daga wasu tashoshin jiragen ruwa
Aiki
Zazzabi
 0°C zuwa +60°C
Aiki
Danshi
5 zuwa 95%, babu sandaro
Kariya IP20 (IEC60529)

Girma

Intesis Modbus Server - Girman girma
Nagartaccen sarari don girka shi a cikin kabad (bango ko hawa dogo), tare da isasshen sarari don haɗin waje

Sabis na Modbus na Intesis -Dimensions2

Alamar IntesisURL https://www.intesis.com
HMS Industrial Networks SLU - An adana duk haƙƙoƙi
Wannan bayanin yana iya canzawa ba tare da sanarwa ba

Takardu / Albarkatu

Intesis Modbus Server [pdf] Manual mai amfani
Modbus Server, Modbus RTU Master, Modbus TCP bawa, Intesis, INMBSRTR0320000

Magana

Bar sharhi

Ba za a buga adireshin imel ɗin ku ba. Ana yiwa filayen da ake buƙata alama *