VLT® Sensọ Input MCB 114 le ṣee lo ni awọn iṣẹlẹ wọnyi:

  • Iṣagbewọle sensọ fun awọn atagba iwọn otutu PT100 ati PT1000 fun abojuto awọn iwọn otutu ti nso.
  • Gẹgẹbi itẹsiwaju gbogbogbo ti awọn igbewọle afọwọṣe pẹlu 1 afikun titẹ sii (0/4-20 mA) fun iṣakoso agbegbe pupọ tabi awọn wiwọn titẹ iyatọ.
  • Ṣe atilẹyin awọn olutona PID ti o gbooro pẹlu I/Os fun ibi ipilẹ, atagba/awọn igbewọle sensọ.
FC jara Software version
VLT® HVAC wakọ FC 102 1.00 ati nigbamii
VLT® AQUA wakọ FC 202 1.41 ati nigbamii
VLT® Automation wakọ FC 301/FC 302 6.02 ati nigbamii

Tabili 1.1 Awọn ẹya sọfitiwia Ṣe atilẹyin VLT® Sensọ Input MCB 114

Awọn nkan Pese

Awọn ohun elo ti a pese dale lori nọmba koodu ti o paṣẹ ati iru apade oluyipada igbohunsafẹfẹ.

Nọmba koodu Awọn nkan ti a pese
130B1172 Ẹya ti a ko bo
130B1272 Ẹya ti a bo

Danfoss-130B1272-Igbewọle-MCB-114-VLT-Sensor-ọpọtọ (1)

Alaye Aabo

IKILO

ÀKỌ́ ÌDÁJỌ́

Oluyipada igbohunsafẹfẹ ni awọn kapasito ọna asopọ DC, eyiti o le wa ni idiyele paapaa nigbati oluyipada igbohunsafẹfẹ ko ni agbara. Iwọn gigatage le wa paapaa nigbati awọn ina Atọka LED ikilọ jẹ o. Ikuna lati duro akoko ti a ti sọtọ lẹhin ti a ti yọ agbara kuro ṣaaju ṣiṣe iṣẹ tabi iṣẹ atunṣe le ja si iku tabi ipalara nla.

  • Duro motor.
  • Ge asopọ awọn mains AC ati awọn ipese agbara ọna asopọ DC latọna jijin, pẹlu awọn afẹyinti batiri, UPS, ati awọn asopọ DC-ọna asopọ si awọn oluyipada igbohunsafẹfẹ miiran.
  • Ge asopọ tabi titiipa PM motor.
  • Duro fun awọn capacitors lati tu silẹ ni kikun. Iye akoko ti o kere julọ ti akoko idaduro ni pato ni Awọn tabili 1.2 si Tabili 1.4.
  • Ṣaaju ṣiṣe eyikeyi iṣẹ tabi iṣẹ atunṣe, lo voltage ẹrọ wiwọn lati rii daju wipe awọn capacitors ti wa ni kikun gba agbara.

sipesifikesonu

Voltage [V] Akoko idaduro to kere julọ (iṣẹju)
4 7 15 20 30 40
200–240 1.1-3.7 kW

(1.50–5 hp)

5.5-45 kW

(7.5–60 hp)

380–480 1.1-7.5 kW

(1.50–10 hp)

11-90 kW

(15–121 hp)

315-1000 kW

(450–1350 hp)

400 90-315 kW

(121–450 hp)

500 110-355 kW

(150–500 hp)

525 75-315 kW

(100–450 hp)

525–600 1.1-7.5 kW

(1.50–10 hp)

11-90 kW

(15–121 hp)

690 90-315 kW

(100–350 hp)

525–690 1.1-7.5 kW

(1.50–10 hp)

11-90 kW

(15–121 hp)

400-1400 kW

(500–1550 hp)

450-1400 kW

(600–1550 hp)

Tabili 1.2 Akoko Sisọ, VLT® HVAC Drive FC 102

Voltage [V] Akoko idaduro to kere julọ (iṣẹju)
4 7 15 20 30 40
200–240 0.25-3.7 kW

(0.34–5 hp)

5.5-45 kW

(7.5–60 hp)

380–480 0.37-7.5 kW

(0.5–10 hp)

11-90 kW

(15–121 hp)

110-315 kW

(150–450 hp)

315-1000 kW

(450–1350 hp)

355-560 kW

(500–750 hp)

525–600 0.75-7.5 kW

(1–10 hp)

11-90 kW

(15–121 hp)

400-1400 kW

(400–1550 hp)

525–690 1.1-7.5 kW

(1.5–10 hp)

11-90 kW

(10–100 hp)

75-400 kW

(75–400 hp)

450-800 kW

(450–950 hp)

Tabili 1.3 Akoko Sisọ, VLT® AQUA wakọ FC 202

Voltage [V] Akoko idaduro to kere julọ (iṣẹju)
  4 7 15 20 30 40
200–240 0.25-3.7 kW

(0.34–5 hp)

5.5-37 kW

(7.5–50 hp)

     
380–500 0.25-7.5 kW

(0.34–10 hp)

11-75 kW

(15–100 hp)

90-200 kW

(150–350 hp)

250-500 kW

(450–750 hp)

250-800 kW

(450–1350 hp)

315–500

(500–750 hp)

400 90-315 kW

(125–450 hp)

500 110-355 kW

(150–450 hp)

525 55-315 kW

(75–400 hp)

525–600 0.75-7.5 kW

(1–10 hp)

11-75 kW

(15–100 hp)

525–690 1.5-7.5 kW

(2–10 hp)

11-75 kW

(15–100 hp)

37-315 kW

(50–450 hp)

355-1200 kW

(450–1550 hp)

355-2000 kW

(450–2050 hp)

355-710 kW

(400–950 hp)

690 55-315 kW

(75–400 hp)

  • Tabili 1.4 Akoko Sisọ, VLT® Automation Drive FC 301/FC 302

Iṣagbesori

Ilana fifi sori ẹrọ da lori iwọn apade ti oluyipada igbohunsafẹfẹ.

Awọn iwọn apade A2, A3, ati B3

  1. Yọ LCP kuro (igbimọ iṣakoso agbegbe), ideri ebute, ati fireemu LCP lati oluyipada igbohunsafẹfẹ.
  2. Darapọ aṣayan sinu Iho B.
  3. So awọn kebulu iṣakoso pọ ki o tu okun naa kuro. Wo Apejuwe 1.4 ati Apejuwe 1.5 fun awọn alaye nipa onirin.
  4. Yọ ikọlu kuro ninu fireemu LCP ti o gbooro (ti a pese).
  5. Fi fireemu LCP ti o gbooro sii ati ideri ebute lori oluyipada igbohunsafẹfẹ.
  6. Darapọ mọ LCP tabi ideri afọju ninu fireemu LCP ti o gbooro.
  7. So agbara pọ mọ oluyipada igbohunsafẹfẹ.
  8. Ṣeto awọn iṣẹ titẹ sii/jade ni awọn aye ti o baamu.

Fifi sori ẹrọ

Àpèjúwe 1.2 Fifi sori ni Awọn iwọn Apoti A2, A3, ati B3

Danfoss-130B1272-Igbewọle-MCB-114-VLT-Sensor-ọpọtọ (2)

1 LCP
2 Ideri ebute
3 Iho B
4 Aṣayan
5 LCP fireemu

Awọn iwọn apade A5, B1, B2, B4, C1, C2, C3, C4, D, E, ati F

  1. Yọ LCP (igbimọ iṣakoso agbegbe) ati ijoko LCP kuro.
  2. Fi kaadi aṣayan sinu Iho B.
  3. So awọn kebulu iṣakoso pọ ki o tu okun naa kuro. Wo Apejuwe 1.4 ati Apejuwe 1.5 fun awọn alaye nipa onirin.
  4. Mu jojolo lori oluyipada igbohunsafẹfẹ.
  5. Darapọ mọ LCP ninu ijoko.

Danfoss-130B1272-Igbewọle-MCB-114-VLT-Sensor-ọpọtọ (3)

1 LCP
2 LCP jojolo
3 Aṣayan
4 Iho B

Apejuwe 1.3 fifi sori ẹrọ ni Awọn iwọn Awọn Apoti miiran (Eksample)

Idabobo Galvanic

Galvanically sọtọ awọn sensosi lati awọn mains voltage ipele. Awọn ibeere aabo: IEC 61800-5-1 ati UL 508C.

Asopọmọra

Wiwa ti VLT® Sensọ Input MCB 114.Danfoss-130B1272-Igbewọle-MCB-114-VLT-Sensor-ọpọtọ (4) Danfoss-130B1272-Igbewọle-MCB-114-VLT-Sensor-ọpọtọ (5)

Ebute Oruko Išẹ
1 VDD 24 V DC lati pese sensọ 0/4-20 mA
2 Mo wọle 0/4-20 mA igbewọle
3 GND Afọwọṣe igbewọle GND
4, 7, 10 Iwọn otutu 1, 2, 3 Iṣagbewọle iwọn otutu
5, 8, 11 Okun 1, 2, 3 Iṣagbewọle waya 3rd ti awọn sensọ waya 3 ba lo
6, 9, 12 GND Iṣagbewọle iwọn otutu GND

Cabling

O pọju ipari okun ifihan agbara jẹ 500 m (1640 ft).

Itanna ati Mechanical pato

Aṣayan naa ni anfani lati pese sensọ afọwọṣe pẹlu 24 V DC (ebute 1).

Nọmba awọn igbewọle afọwọṣe 1
Ọna kika 0-20 mA tabi 4-20 mA
Awọn onirin 2 onirin
Input Impedance <200 Ω
Sample oṣuwọn 1 kHz
Àlẹmọ ibere 3 100 Hz ni 3 dB

Tabili 1.6 Afọwọṣe Analog

Nọmba awọn igbewọle afọwọṣe ti n ṣe atilẹyin

PT100/1000

3
Iru ifihan agbara PT100/PT1000
Asopọmọra PT100 2 tabi 3 waya

PT1000 2 tabi 3 waya

Igbohunsafẹfẹ PT100 ati PT1000 input 1 Hz fun ikanni kọọkan
Ipinnu 10 die-die
Iwọn iwọn otutu -50 si +204 °C

-58 si +399 ° F

Tabili 1.7 Input Sensọ otutu

Iṣeto ni

  • Awọn igbewọle sensọ 3 ṣe atilẹyin awọn sensọ okun waya 2 ati 3 ati wiwa adaṣe ti iru sensọ, PT100 tabi PT1000 gba awọn aaye ni agbara-soke.
  • Iṣagbewọle afọwọṣe ni agbara lati mu 0/4–20 mA mu.

Fun siseto awọn paramita, wo itọsọna siseto ọja-kan pato, ẹgbẹ paramita 35-** Aṣayan Input Sensọ ati ẹgbẹ paramita 18-3* Awọn kika Analog pẹlu awọn kika data ni paramita 18-36 Input Analog X48/2 [mA] si
paramita 18-39 Temp. Agbewọle X48/10.

ALAYE SIWAJU

Danfoss ko le gba ojuse fun awọn aṣiṣe ti o ṣee ṣe ninu awọn iwe katalogi, awọn iwe pẹlẹbẹ ati awọn ohun elo titẹjade miiran. Danfoss ni ẹtọ lati paarọ awọn ọja rẹ laisi akiyesi. Eyi tun kan awọn ọja tẹlẹ lori aṣẹ ti o pese pe iru awọn iyipada le ṣee ṣe laisi awọn ayipada atẹle jẹ pataki ni awọn pato ti gba tẹlẹ. Gbogbo awọn aami-išowo ti o wa ninu ohun elo yii jẹ ohun-ini ti awọn ile-iṣẹ oniwun. Danfoss ati Danfoss logotype jẹ aami-iṣowo ti Danfoss A/S. Gbogbo awọn ẹtọ wa ni ipamọ.

FAQs

  • Q: Kini MO yẹ ṣe ti awọn ina Atọka LED ti ikilọ wa ni pipa ṣugbọn volol giga tun le watage wa?
    •  A: Nigbagbogbo duro fun akoko idaduro ti o kere ju lẹhin yiyọ agbara kuro ṣaaju ṣiṣe eyikeyi iṣẹ tabi iṣẹ atunṣe. Lo ohun yẹ voltage ẹrọ wiwọn lati rii daju pe awọn capacitors ti gba agbara ni kikun.