Danfoss 130B1272 Lowetsani MCB 114 VLT Sensor
ZAMBIRI ZA PRODUCT
The VLT® Sensor Input MCB 114 can be used in the following cases:
- Kuyika kwa sensor kwa ma transmitters a kutentha PT100 ndi PT1000 powunikira kutentha.
- As general extension of analog inputs with 1 extra input (0/4–20 mA) for multi-zone control or differential pressure measurements.
- Support extended PID controllers with I/Os for setpoint, transmitter/sensor inputs.
FC series | Mtundu wa mapulogalamu |
VLT® HVAC Drive FC 102 | 1.00 ndi pambuyo pake |
VLT® AQUA Drive FC 202 | 1.41 ndi pambuyo pake |
VLT® Automation Drive FC 301/FC 302 | 6.02 ndi pambuyo pake |
Table 1.1 Software Versions Supporting the VLT® Sensor Input MCB 114
Zinthu Zaperekedwa
Zinthu zomwe zimaperekedwa zimatengera nambala ya code yoyitanitsa komanso mtundu wachitetezo cha ma frequency converter.
Nambala ya kodi | Zinthu zaperekedwa |
Mtengo wa 130B1172 | Uncoated version |
Mtengo wa 130B1272 | Coated version |
Zambiri Zachitetezo
CHENJEZO
NTHAWI YOCHITA
Ma frequency converter ali ndi ma capacitor a DC-link, omwe amatha kukhalabe ndi mlandu ngakhale wosinthira pafupipafupi alibe mphamvu. Mphamvu yapamwambatage akhoza kukhalapo ngakhale pamene chenjezo LED chizindikiro nyali ndi o. Kulephera kuyembekezera nthawi yotchulidwa mphamvu itachotsedwa musanayambe ntchito kapena kukonza ntchito kungayambitse imfa kapena kuvulala koopsa.
- Imitsa galimoto.
- Chotsani ma mains a AC ndi magetsi akutali a DC-link, kuphatikiza ma batire, UPS, ndi maulumikizidwe a DC ndi ma frequency ena.
- Chotsani kapena kutseka PM motor.
- Wait for the capacitors to discharge fully. The minimum duration of waiting time is specified in Tables 1.2 to Table 1.4.
- Musanagwire ntchito iliyonse kapena kukonza, gwiritsani ntchito voliyumu yoyeneratagchipangizo choyezera kuti muwonetsetse kuti ma capacitor atulutsidwa kwathunthu.
kufotokoza
Voltagndi [V] | Kudikirira nthawi yochepa (mphindi) | |||||
4 | 7 | 15 | 20 | 30 | 40 | |
200-240 | 1.1-3.7 kW
(1.50–5 hp) |
– | 5.5-45 kW
(7.5–60 hp) |
– | – | – |
380-480 | 1.1-7.5 kW
(1.50–10 hp) |
– | 11-90 kW
(15–121 hp) |
– | – | 315-1000 kW
(450–1350 hp) |
400 | – | – | – | 90-315 kW
(121–450 hp) |
– | – |
500 | – | – | – | 110-355 kW
(150–500 hp) |
– | – |
525 | – | – | – | 75-315 kW
(100–450 hp) |
– | – |
525-600 | 1.1-7.5 kW
(1.50–10 hp) |
– | 11-90 kW
(15–121 hp) |
– | – | – |
690 | – | – | – | 90-315 kW
(100-350 hp) |
– | – |
525-690 | – | 1.1-7.5 kW
(1.50–10 hp) |
11-90 kW
(15–121 hp) |
– | 400-1400 kW
(500–1550 hp) 450-1400 kW (600–1550 hp) |
– |
Table 1.2 Discharge Time, VLT® HVAC Drive FC 102
Voltagndi [V] | Kudikirira nthawi yochepa (mphindi) | |||||
4 | 7 | 15 | 20 | 30 | 40 | |
200-240 | 0.25-3.7 kW
(0.34–5 hp) |
– | 5.5-45 kW
(7.5–60 hp) |
– | – | – |
380-480 | 0.37-7.5 kW
(0.5–10 hp) |
– | 11-90 kW
(15–121 hp) |
110-315 kW
(150–450 hp) |
– | 315-1000 kW
(450–1350 hp) 355-560 kW (500–750 hp) |
525-600 | 0.75-7.5 kW
(1–10 hp) |
– | 11-90 kW
(15–121 hp) |
– | 400-1400 kW
(400–1550 hp) |
– |
525-690 | – | 1.1-7.5 kW
(1.5–10 hp) |
11-90 kW
(10–100 hp) |
75-400 kW
(75–400 hp) |
– | 450-800 kW
(450–950 hp) |
Table 1.3 Discharge Time, VLT® AQUA Drive FC 202
Voltagndi [V] | Kudikirira nthawi yochepa (mphindi) | |||||
4 | 7 | 15 | 20 | 30 | 40 | |
200-240 | 0.25-3.7 kW
(0.34–5 hp) |
– | 5.5-37 kW
(7.5–50 hp) |
|||
380-500 | 0.25-7.5 kW
(0.34–10 hp) |
– | 11-75 kW
(15–100 hp) |
90-200 kW
(150–350 hp) |
250-500 kW
(450–750 hp) |
250-800 kW
(450–1350 hp) 315-500 (500–750 hp) |
400 | – | – | – | 90-315 kW
(125–450 hp) |
– | – |
500 | – | – | – | 110-355 kW
(150–450 hp) |
– | – |
525 | – | – | – | 55-315 kW
(75–400 hp) |
– | – |
525-600 | 0.75-7.5 kW
(1–10 hp) |
– | 11-75 kW
(15–100 hp) |
– | – | – |
525-690 | – | 1.5-7.5 kW
(2–10 hp) |
11-75 kW
(15–100 hp) |
37-315 kW
(50–450 hp) |
355-1200 kW
(450–1550 hp) |
355-2000 kW
(450–2050 hp) 355-710 kW (400–950 hp) |
690 | – | – | – | 55-315 kW
(75–400 hp) |
– | – |
- Table 1.4 Kutulutsa Nthawi, VLT® Automation Drive FC 301/FC 302
Kukwera
Ndondomeko yoyika zimadalira kukula kwa mpanda wa otembenuza pafupipafupi.
Enclosure sizes A2, A3, and B3
- Remove the LCP (local control panel), the terminal cover, and the LCP frame from the frequency converter.
- Gwirizanitsani mwayiwo mu slot B.
- Connect the control cables and relieve the cable. See Illustration 1.4 and Illustration 1.5 for details about wiring.
- Remove the knockout in the extended LCP frame (supplied).
- Fit the extended LCP frame and terminal cover on the frequency converter.
- Ikani LCP kapena chivundikiro chakhungu mu chimango chowonjezera cha LCP.
- Lumikizani mphamvu ku frequency converter.
- Khazikitsani ntchito zolowetsa / zotulutsa muzofananira.
KUYANG'ANIRA
Chithunzi 1.2 Installation in Enclosure Sizes A2, A3, and B3
1 | Zithunzi za LCP |
2 | Chophimba cha terminal |
3 | Malo B |
4 | Njira |
5 | Chithunzi cha LCP |
Enclosure sizes A5, B1, B2, B4, C1, C2, C3, C4, D, E, and F
- Remove the LCP (local control panel) and the LCP cradle.
- Gwirizanitsani khadilo mu slot B.
- Connect the control cables and relieve the cable. See Illustration 1.4 and Illustration 1.5 for details about wiring.
- Fit the cradle on the frequency converter.
- Gwirizanitsani LCP mu chikwama.
1 | Zithunzi za LCP |
2 | Chithunzi cha LCP |
3 | Njira |
4 | Malo B |
Chithunzi 1.3 Kuyika mu Makulidwe Ena Otsekera (Eksample)
Galvanic Insulation
Galvanically alekanitsa masensa kuchokera mains voltagndi level. Zofunikira pachitetezo: IEC 61800-5-1 ndi UL 508C.
Wiring
Ma waya a VLT® Sensor Input MCB 114.
Pokwerera | Dzina | Ntchito |
1 | VDD | 24 V DC to supply 0/4–20 mA sensor |
2 | Ine mu | 0/4–20 mA input |
3 | GND | Analog input GND |
4, 7, 10 | Temp 1, 2, 3 | Kuyika kwa kutentha |
5, 8, 11 | Wire 1, 2, 3 | 3rd wire input if 3 wire sensors are used |
6, 9, 12 | GND | Temperature input GND |
Kukambirana
Kutalika kwakukulu kwa chingwe ndi 500 m (1640 ft).
Zamagetsi ndi Makina
Njirayi imatha kupereka sensor ya analogi ndi 24 V DC (terminal 1).
Chiwerengero cha zolowetsa za analogi | 1 |
Mtundu | 0-20 mA kapena 4-20 mA |
Mawaya | 2 mawaya |
Kulowetsa Impedans | <200 Ω |
Sample rate | 1 kHz |
3rd order filter | 100 Hz at 3 dB |
Table 1.6 Kulowetsa Analog
Number of analog inputs supporting
Mtengo wa PT100/1000 |
3 |
Mtundu wa siginecha | PT100/PT1000 |
Kulumikizana | PT100 2 or 3 wire
PT1000 2 or 3 wire |
Frequency PT100 and PT1000 input | 1 Hz for each channel |
Kusamvana | 10 pang'ono |
Kutentha kosiyanasiyana | -50 mpaka +204 °C
-58 mpaka +399 ° F |
Table 1.7 Kulowetsa kwa Sensor Kutentha
Kusintha
- The 3 sensor inputs support 2 and 3 wire sensors and an auto detection of sensor type, PT100 or PT1000 takes places at power-up.
- The analog input is capable of handling 0/4–20 mA.
For programming of the parameters, see the product-specific programming guide, parameter group 35-** Sensor Input Option and parameter group 18-3* Analog Readouts with data readouts in parameter 18-36 Analog Input X48/2 [mA] to
parameter 18-39 Temp. Input X48/10.
ZAMBIRI ZAMBIRI
Danfoss sangavomereze chifukwa cha zolakwika zomwe zingatheke m'mabuku, timabuku ndi zinthu zina zosindikizidwa. Danfoss ali ndi ufulu wosintha zinthu zake popanda kuzindikira. Izi zikugwiranso ntchito kuzinthu zomwe zakhazikitsidwa kale malinga ngati zosinthazo zitha kupangidwa popanda kusintha kotsatira komwe kuli kofunikira pazogwirizana kale. Zizindikiro zonse zomwe zili m'nkhaniyi ndi zamakampani omwe akukhudzidwa. Danfoss ndi Danfoss logotype ndi zilembo za Danfoss A/S. Maumwini onse ndi otetezedwa.
- Malingaliro a kampani Danfoss A/S
- Zotsatira 1
- DK-6300 Graasten
- vlt-drives.danfoss.com
FAQs
- Q: Nditani ngati nyali zochenjeza za LED zazimitsidwa koma pakhoza kukhala mphamvu yayikulutagndi pano?
- A: Always wait for the specified minimum waiting time after removing power before performing any service or repair work. Use an appropriate voltage measuring device to ensure capacitors are fully discharged.
Zolemba / Zothandizira
![]() |
Danfoss 130B1272 Lowetsani MCB 114 VLT Sensor [pdf] Kukhazikitsa Guide MI38T202, 130B1272 Input MCB 114 VLT Sensor, 130B1272, Input MCB 114 VLT Sensor, MCB 114 VLT Sensor, 114 VLT Sensor, VLT Sensor, Sensor |